Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Soils Sediments ; 21(4): 1875-1889, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34720744

RESUMEN

PURPOSE: Intensive livestock grazing has been associated with an increased risk of soil erosion and concomitant negative impacts on the ecological status of watercourses. Whilst various mitigation options are promoted for reducing livestock impacts, there is a paucity of data on the relationship between stocking rates and quantified sediment losses. This evidence gap means there is uncertainty regarding the cost-benefit of policy preferred best management. METHODS: Sediment yields from 15 hydrologically isolated field scale catchments on a heavily instrumented ruminant livestock farm in the south west UK were investigated over ~ 26 months spread across 6 years. Sediment yields were compared to cattle and sheep stocking rates on long-term, winter (November-April), and monthly timescales. The impacts of livestock on soil vegetation cover and bulk density were also examined. Cattle were tracked using GPS collars to determine how grazing related to soil damage. RESULTS: No observable impact of livestock stocking rates of 0.15-1.00 UK livestock units (LU) ha-1 for sheep, and 0-0.77 LU ha-1 for cattle on sediment yields was observed at any of the three timescales. Cattle preferentially spent time close to specific fences where soils were visually damaged. However, there was no indication that livestock have a significant effect on soil bulk density on a field scale. Livestock were housed indoors during winters when most rainfall occurs, and best management practices were used which when combined with low erodibility clayey soils likely limited sediment losses. CONCLUSION: A combination of clayey soils and soil trampling in only a small proportion of the field areas lead to little impact from grazing livestock. Within similar landscapes with best practice livestock grazing management, additional targeted measures to reduce erosion are unlikely to yield a significant cost-benefit. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11368-021-02909-y.

2.
Water Sci Technol ; 75(3-4): 518-529, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28192346

RESUMEN

Given the shift in perception of wastewater treatment plants as water resource recovery facilities, conventional mathematical models need to be updated. The resource recovery perspective should be applied to new processes, technologies and plant layouts. The number and level of models proposed to date give an overview of the complexity of the new plant configurations and provides a wide range of possibilities and process combinations in order to construct plant layouts. This diversity makes the development of standard, modular and flexible tools and model libraries that allow the incorporation of new processes and components in a straightforward way a necessity. In this regard, the plant-wide modelling (PWM) library is a complete model library that includes conventional and advanced technologies and that allows economic and energetic analyses to be carried out in a holistic way. This paper shows the fundamentals of this PWM library that is built upon the above-mentioned premises and the application of the PWM library in three different full-scale case studies.


Asunto(s)
Modelos Teóricos , Aguas del Alcantarillado/química , Aguas Residuales/química , Purificación del Agua/métodos , España , Purificación del Agua/economía
3.
Water Sci Technol ; 69(7): 1552-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24718350

RESUMEN

The paper presents a systematic study of simulations, using a previously calibrated Colloid model, from which it was found that: (i) for pure moving-bed biofilm reactor (MBBR) processes with tertiary nitrification conditions (no influent chemical oxygen demand (COD)), dissolved oxygen = 5 mg/L and residual NH4-N > 4 mgN/L, a nitrification rate of 1.2 gN/(m(2)d) was obtained at 10 °C. This rate decreases sharply when residual NH4-N is lower than 2 mgN/L, (ii) for MBBR systems with predenitrification-nitrification zones and COD in the influent (soluble and particulate), the nitrification rate (0.6 gN/(m(2)d)) is half of that in tertiary nitrification due to the effect of influent colloidal XS (particulate slowly biodegradable COD) and (iii) for integrated fixed-film activated sludge (IFAS) processes the nitrification rate in the biofilm (0.72 gN/(m(2)d)) is 20% higher than for the pure MBBR due to the lower effect of influent XS since it is adsorbed onto flocs. However, it is still 40% lower than the tertiary nitrification rate. In the IFAS, the fraction of the nitrification rate in suspension ranges from 10 to 70% when the aerobic solids retention time varies from 1.4 to 6 days.


Asunto(s)
Reactores Biológicos , Modelos Biológicos , Nitrificación , Administración de Residuos , Aerobiosis , Biopelículas , Coloides , Simulación por Computador
4.
J Psychiatr Res ; 177: 31-38, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38971054

RESUMEN

Comorbid anxiety and depression predict a poorer prognosis than either disorder occurring alone. It is unclear whether self-reported anxiety symptom scores identify patients with depression in need of more intensive mental health services. This study evaluated how anxiety symptoms predicted treatment receipt and outcomes among patients with new depression diagnoses in the Veterans Health Administration (VHA). Electronic medical record data from 128,917 VHA patients (71.6% assessed for anxiety, n = 92,237) with new diagnoses of depression were analyzed to examine how Generalized Anxiety Disorder-7 (GAD-7) scores predicted psychotropic medication prescriptions, psychotherapy receipt, acute care service utilization, and follow-up depression symptoms. Patients who reported severe symptoms of anxiety were significantly more likely to receive adequate acute phase and continuation phase antidepressant treatment, daytime anxiolytics/sedatives, nighttime sedative/hypnotics, and endorse more severe depression symptoms and suicidal ideation at follow-up. Patients who reported severe symptoms of anxiety at baseline were less likely to initiate psychotherapy. The GAD-7 may help identify depressed patients who have more severe disease burden and require additional mental health services.

5.
Water Sci Technol ; 68(2): 296-302, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23863420

RESUMEN

This paper summarizes part of the research work carried out in the Add Control project, which proposes an extension of the wastewater treatment plant (WWTP) models and modelling architectures used in traditional WWTP simulation tools, addressing, in addition to the classical mass transformations (transport, physico-chemical phenomena, biological reactions), all the instrumentation, actuation and automation & control components (sensors, actuators, controllers), considering their real behaviour (signal delays, noise, failures and power consumption of actuators). Its ultimate objective is to allow a rapid transition from the simulation of the control strategy to its implementation at full-scale plants. Thus, this paper presents the application of the Add Control simulation platform for the design and implementation of new control strategies at the WWTP of Mekolalde.


Asunto(s)
Modelos Teóricos , Eliminación de Residuos Líquidos/métodos , Simulación por Computador , Europa (Continente) , Cooperación Internacional , Nitrógeno/análisis , Contaminantes Químicos del Agua/análisis
6.
Water Sci Technol ; 65(11): 1929-38, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22592461

RESUMEN

The increasing costs associated with water supply and the disposal of wastewater has stimulated industries to seek more efficient water management systems. Mathematical modelling and simulation can be a very valuable tool for the study of the multiple alternatives available whilst assessing optimum solutions for water management in industry. This study introduces a new steady state model library able to reproduce industrial water circuits. It has been implemented in a novel software framework for the representation, simulation and optimization of industrial water networks. A water circuit representing a paper mill has been modelled and simulated showing the capability to reproduce real case studies. Alternative scenarios for the water network have also been tested to assess the capability of the models to optimize water circuits minimizing total cost.


Asunto(s)
Residuos Industriales/análisis , Modelos Teóricos , Papel , Eliminación de Residuos Líquidos/economía , Eliminación de Residuos Líquidos/métodos , Contaminantes Químicos del Agua/química , Purificación del Agua
7.
Water Sci Technol ; 64(3): 557-67, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22097032

RESUMEN

This paper presents the characterisation procedure of different types of sludge generated in a wastewater treatment plant to be reproduced in a mathematical model of the sludge digestion process. The automatic calibration method used is based on an optimisation problem and uses a set of mathematical equations related to the a priori knowledge of the sludge composition, the experimental measurements applied to the real sludge, and the definition of the model components. In this work, the potential of the characterisation methodology is shown by means of a real example, taking into account that sludge is a very complex matter to characterise and that the models for digestion also have a considerable number of model components. The results obtained suit both the previously reported characteristics of the primary, secondary and mixed sludge, and the experimental measurements specially done for this work. These three types of sludge have been successfully characterised to be used in complex mathematical models.


Asunto(s)
Automatización , Modelos Teóricos , Aguas del Alcantarillado , Anaerobiosis , Biodegradación Ambiental
8.
Water Res ; 200: 117242, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34052476

RESUMEN

The effect of mixing in the modelling of processes based on mass transfer phenomena is commonly ignored in wastewater treatment industry. In this contribution, the effect of the average shear rate in the nucleation and growth rates of struvite is analyzed by combining experimental data with simulation results obtained with a previously presented mass-based discretized population balance model. According to the obtained results, the effect of the average shear rate is identifiable for the selected data and mechanisms. Therefore, it should be considered when a detailed modelling of the process is needed. Consequently, in this contribution, the average shear rate has been decoupled from the kinetic constants. In addition, kinetic rates where it is explicitly included as a power law function have been proposed. The exponents in these power law functions for the primary homogeneous nucleation and growth are 1.3 and 0.3, respectively. Considering shear rate effects allowed to see in the simulation outputs experimentally observed effects: a faster pH decay and smaller particle distribution for increasing mixing intensities.


Asunto(s)
Compuestos de Magnesio , Fosfatos , Precipitación Química , Cinética , Estruvita
9.
Water Res ; 206: 117779, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34717244

RESUMEN

Ammonia ion removal and recovery via an ion-exchange process using zeolites is a promising alternative to traditional biological treatments. The analysis of its efficiency is not straightforward as it depends on various factors, such as the cation exchange capacity of the zeolite, amount of zeolite available, initial ammonia concentration, contact time, ammonia speciation depending on pH or the presence of competing ions. Mathematical modelling and simulation tools are very useful to analyse the effect of different operational conditions on the efficiency and optimal operation of the process. This paper experimentally analyses the effect that the presence of competing ions has on the efficiency of ammonia removal. This experimental work has shown a reduction of around 21% of ammonia removal efficiency in the presence of competing ions. The main contribution of this paper is the development new mathematical model able to describe the ion-exchange process in the presence of competing ions. The mathematical model developed is able to analyse the performance of the IEX process under different empty bed contact times, influent loads, pH and concentrations of competing ions. The capability of the model to reproduce real data has been proven comparing the experimental and simulation results. Finally, an exploration by simulation has been undertaken to show the potential of the mathematical model developed.


Asunto(s)
Amoníaco , Zeolitas , Adsorción , Calibración , Intercambio Iónico , Iones , Modelos Teóricos
10.
Rev Esp Enferm Dig ; 102(10): 587-90, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21039067

RESUMEN

The standard treatment of chronic hepatitis C, pegylated interferon and ribavirin (pegI/R), has many limitations in both effectiveness and secondary effects, which makes it unsuitable or even contraindicated for some patients. In hepatitis C virus-infected cystic fibrosis patients this treatment could increase respiratory infections with subsequent pulmonary function deterioration. On the contrary, hepatitis C virus (HCV) infection may make lung transplant (LT) unfeasible. We present the case of a cystic fibrosis-young man diagnosed with HCV infection during LT assessment who was treated with pegI/R. In spite of the lung function worsening and respiratory infections, he managed to complete treatment and even sustained virological response (SVR). At present he is on LT waiting list.


Asunto(s)
Fibrosis Quística/complicaciones , Fibrosis Quística/cirugía , Hepatitis C Crónica/tratamiento farmacológico , Trasplante de Pulmón/fisiología , Adulto , Antivirales/uso terapéutico , Quimioterapia Combinada , Hepatitis C Crónica/complicaciones , Humanos , Interferones/uso terapéutico , Hígado/patología , Masculino , Sistema Porta/patología , Ribavirina/uso terapéutico
11.
Water Sci Technol ; 59(1): 141-7, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19151496

RESUMEN

In this paper a comparative analysis of the most important approaches for integrated WWTP modelling is presented. After an introductory presentation of the most important drawbacks and challenges for plant wide modelling, the fundamentals of three different approaches to construct integrated models are presented: "Interfaces" "Standard Supermodel" and "Tailored Supermodel". Afterwards, a comparative analysis of these approaches from different points of view (difficulties for the model end user, characterization of the process in the plant, flexibility or adaptability for each case of study, simulation platform requirements and computational costs) is carried out. From this comparison, some important conclusions about the suitability of each alternative depending on the simulation case study are extracted.


Asunto(s)
Modelos Teóricos , Aguas del Alcantarillado , Eliminación de Residuos Líquidos , Simulación por Computador , Oxígeno/química , Oxígeno/metabolismo
12.
Water Res ; 153: 39-52, 2019 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-30690217

RESUMEN

Phosphorus has been considered as a pollutant to be removed from the wastewater. In the last years, however, it has been considered a valuable asset that needs to be recovered due to its shortage in nature. The study of optimum phosphorus management in wastewater treatment plants is not straightforward, due to the complexity of technologies and configurations that may be applied for phosphorus removal and recovery. In this context, plant-wide mathematical modelling and simulation tools are very useful for carrying out these studies. This paper introduces a study carried out at the Sur WWTP (Madrid) to assess optimum phosphorus management strategies based on the PWM. The mathematical model made it possible to describe the phosphorus flux and its characterization throughout the plant. Finally, an exploration by simulation with WEST™ was carried out to analyse different plant configurations and different operational strategies to optimize phosphorus management strategies in the Sur WWTP.


Asunto(s)
Fósforo , Eliminación de Residuos Líquidos , Modelos Teóricos , Aguas del Alcantarillado , Aguas Residuales
13.
Water Res ; 155: 26-41, 2019 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-30831422

RESUMEN

Mathematical models describing precipitation processes in one step need to be upgraded. Particle size distribution is a crucial variable and its inclusion in the modelling libraries is necessary if the technology wants to be optimized through simulation. With this objective, a mass based population balance model is presented in this contribution. The model has been constructed using a stoichiometric matrix and a kinetic vector and using mass as the internal coordinate, as it is usually done in wastewater treatment modelling. Identifiability of the parameters of the model was evaluated using a sensitivity and a collinearity analysis for six simulation case studies of struvite precipitation. In addition, parameters in the model were calibrated to represent data from two batch tests in the laboratory. The results of the analysis showed that the identifiability of the parameters depends on the available experimental data and explored scenarios. Identifiability of the parameters could be the reason behind the shifting parameter values describing mechanisms of precipitation in the literature. This contribution helps to understand the possibilities and limitations that the population balance model approach offer.


Asunto(s)
Modelos Teóricos , Aguas Residuales , Precipitación Química , Cinética , Fosfatos , Estruvita
14.
Water Res ; 129: 305-318, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29156395

RESUMEN

This paper introduces a new mathematical model built under the PC-PWM methodology to describe the aeration process in a full-scale WWTP. This methodology enables a systematic and rigorous incorporation of chemical and physico-chemical transformations into biochemical process models, particularly for the description of liquid-gas transfer to describe the aeration process. The mathematical model constructed is able to reproduce biological COD and nitrogen removal, liquid-gas transfer and chemical reactions. The capability of the model to describe the liquid-gas mass transfer has been tested by comparing simulated and experimental results in a full-scale WWTP. Finally, an exploration by simulation has been undertaken to show the potential of the mathematical model.


Asunto(s)
Modelos Teóricos , Transición de Fase , Purificación del Agua , Nitrógeno , Aguas del Alcantarillado
15.
Water Res ; 41(19): 4357-72, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17640702

RESUMEN

This paper presents a new plant-wide modelling methodology for describing the dynamic behaviour of water and sludge lines in WWTPs. The methodology is based on selecting the set of process transformations needed for each specific WWTP to model all unit-process elements in the entire plant. This "transformation-based" approach, in comparison with the conventional "process-based" approach, does not require the development of specific transformers to interface the resulting unit-process models, facilitates the mass and charge continuity throughout the whole plant and is flexible enough to construct models tailored for each plant under study. As an illustrative example, a plant-wide model for a WWTP that includes carbon removal and anaerobic digestion has been constructed, and the main advantages of the proposed methodology for integrated modelling have been demonstrated. As a final consequence, this paper proposes a rewriting of the existing unit-process models according to the new standard transformation-based approach for integrated modelling purposes.


Asunto(s)
Restauración y Remediación Ambiental/métodos , Modelos Teóricos , Aguas del Alcantarillado
16.
Water Sci Technol ; 56(8): 57-65, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17978433

RESUMEN

In this paper, a new methodology for integrated modelling of the WWTP has been used for the construction of the Benchmark Simulation Model N degrees 2 (BSM2). The transformations-approach proposed in this methodology does not require the development of specific transformers to interface unit process models and allows the construction of tailored models for a particular WWTP guaranteeing the mass and charge continuity for the whole model. The BSM2 PWM constructed as case study, is evaluated by means of simulations under different scenarios and its validity in reproducing water and sludge lines in WWTP is demonstrated. Furthermore the advantages that this methodology presents compared to other approaches for integrated modelling are verified in terms of flexibility and coherence.


Asunto(s)
Modelos Teóricos , Eliminación de Residuos Líquidos , Benchmarking , Simulación por Computador , Reproducibilidad de los Resultados , Aguas del Alcantarillado , Factores de Tiempo , Movimientos del Agua , Contaminantes del Agua
17.
Water Sci Technol ; 56(8): 95-106, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17978437

RESUMEN

This paper proposes a new methodology for the automatic characterization of the influent wastewater in WWTP. With this methodology, model components are automatically estimated by means of optimization algorithms combining a-priori knowledge of the expected wastewater composition with experimental information from the available measurement data. The characterization is carried out based on an extended model components list in which components are described by means their elemental mass fractions. This allows an easy establishment of relationships between model components with experimental data and also, to obtain a general methodology applicable to any model used for wastewater biological treatments. The characterization of the wastewater influent of Galindo-Bilbao according this methodology has demonstrated its validity and the easy application to the ASM1 model influent characterization.


Asunto(s)
Modelos Teóricos , Eliminación de Residuos Líquidos , Algoritmos , Automatización , Reactores Biológicos , Calibración , Agua/química , Abastecimiento de Agua
18.
Water Res ; 118: 272-288, 2017 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-28456110

RESUMEN

The growing development of technologies and processes for resource treatment and recovery is offering endless possibilities for creating new plant-wide configurations or modifying existing ones. However, the configurations' complexity, the interrelation between technologies and the influent characteristics turn decision-making into a complex or unobvious process. In this frame, the Plant-Wide Modelling (PWM) library presented in this paper allows a thorough, comprehensive and refined analysis of different plant configurations that are basic aspects in decision-making from an energy and resource recovery perspective. In order to demonstrate the potential of the library and the need to run simulation analyses, this paper carries out a comparative analysis of WWTPs, from a techno-economic point of view. The selected layouts were (1) a conventional WWTP based on a modified version of the Benchmark Simulation Model No. 2, (2) an upgraded or retrofitted WWTP, and (3) a new Wastewater Resource Recovery Facilities (WRRF) concept denominated as C/N/P decoupling WWTP. The study was based on a preliminary analysis of the organic matter and nutrient energy use and recovery options, a comprehensive mass and energy flux distribution analysis in each configuration in order to compare and identify areas for improvement, and a cost analysis of each plant for different influent COD/TN/TP ratios. Analysing the plants from a standpoint of resources and energy utilization, a low utilization of the energy content of the components could be observed in all configurations. In the conventional plant, the COD used to produce biogas was around 29%, the upgraded plant was around 36%, and 34% in the C/N/P decoupling WWTP. With regard to the self-sufficiency of plants, achieving self-sufficiency was not possible in the conventional plant, in the upgraded plant it depended on the influent C/N ratio, and in the C/N/P decoupling WWTP layout self-sufficiency was feasible for almost all influents, especially at high COD concentrations. The plant layouts proposed in this paper are just a sample of the possibilities offered by current technologies. Even so, the library presented here is generic and can be used to construct any other plant layout, provided that a model is available.


Asunto(s)
Aguas Residuales , Purificación del Agua/instrumentación , Aguas del Alcantarillado , Eliminación de Residuos Líquidos
19.
Water Sci Technol ; 53(4-5): 193-201, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16722070

RESUMEN

This paper presents the theoretical basis and the main results obtained during the development and full-scale experimental validation of the new supervisory control strategy designed for the Galindo-Bilbao wastewater treatment plant (WWTP). The different phases of the project have been carried out over the last 8 years, combining model simulations, pilot-plant experimentation and full-scale validation. The final control strategy combines three complementary control loops to optimise the nitrogen removal in pre-denitrifying activated sludge plants. The first controller was designed to maintain the average concentration of the ammonia in the effluent via the automatic selection of the most appropriate DO set point in the aerobic reactors. The second control loop optimises the use of the denitrification potential and finally, the third control loop maintains the selected amount of biomass in the biological reactors by automatic manipulation of the wastage rate. Mobile-averaged windows have been implemented to incorporate commonly used averaged values in the control objectives. The performance of the controllers has been successfully assessed through the full-scale experimental validation in one of the lines of the WWTP.


Asunto(s)
Eliminación de Residuos Líquidos/métodos , Movimientos del Aire , Amoníaco/análisis , Automatización , Reactores Biológicos , Retroalimentación , Nitratos/análisis , Oxígeno/análisis , Aguas del Alcantarillado , España
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA