Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Endovasc Ther ; 30(4): 615-627, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35466777

RESUMEN

PURPOSE: Contemporary diagnostic modalities, including contrast-enhanced computed tomography (CTA) and duplex ultrasound, have been insufficiently able to predict endograft thrombosis. This study introduces an implementation of image-based computational fluid dynamics (CFD), by exemplification with 4 patients treated with an endograft for occlusive disease of the superficial femoral artery (SFA). The potential of personalized CFD for predicting endograft thrombosis is investigated. MATERIALS AND METHODS: Four patients treated with endografts for an occluded SFA were retrospectively included. CFD simulations, based on CTA and duplex ultrasound, were compared for patients with and without endograft thrombosis to investigate potential flow-related causes of endograft thrombosis. Time-averaged wall shear stress (TAWSS) was computed, which highlights areas of prolonged residence times of coagulation factors in the graft. RESULTS: CFD simulations demonstrated normal TAWSS (>0.4 Pa) in the SFA for cases 1 and 2, but low levels of TAWSS (<0.4 Pa) in cases 3 and 4, respectively. Primary patency was achieved in cases 1 and 2 for over 2 year follow-up. Cases 3 and 4 were complicated by recurrent endograft thrombosis. CONCLUSION: The presence of a low TAWSS was associated with recurrent endograft thrombosis in subjects with otherwise normal anatomic and ultrasound assessment and a good distal run-off.


Asunto(s)
Implantación de Prótesis Vascular , Trombosis , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Hidrodinámica , Estudios Retrospectivos , Resultado del Tratamiento , Trombosis/diagnóstico por imagen , Trombosis/etiología , Hemodinámica , Modelos Cardiovasculares
2.
J Endovasc Ther ; 30(1): 8-17, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35114834

RESUMEN

OBJECTIVE: To identify and analyze the published in vitro benchtop experiments for the assessment of endovascular techniques used for the treatment of juxtarenal abdominal aortic aneurysms (jAAAs). DATA SOURCES: Scopus, PubMed, and Web of Science. REVIEW METHODS: A systematic literature search was carried out throughout March 2021 following PRISMA guidelines. Two investigators independently performed title and abstract screening to reveal all benchtop testing evaluating the endovascular treatment of jAAA. RESULTS: A total of 19 studies were included, 8 evaluating fenestrated (FEVAR) and 11 parallel grafts (PGs). FEVAR studies used different custom testing apparatus (n=7) or 3D-printed models (n=1) to analyze dislodgement and migration resistance, misalignment consequences and causation, and bridging stents' radial force, flareability, fatigue, and fracture resistance. All PG studies used silicone-based models to analyze optimal oversizing, sealing length, gutter behavior, and possible reduction. Test evaluation in FEVAR in vitro testing was based on pullout force analysis (N=5), photo evaluation (n=1), fluoroscopy (n=1), X-rays (n=4), CT analysis (n=3), macro- and microscopic evaluation (n=4), water permeability (n=1), and fatigue simulator testing (n=1), while it was based on CT analysis in all PG studies adding ECG-gate in one study. The most frequently tested devices were Zenit (Cook) (n=7), Endurant (Medtronic) (n=5), and Excluder (Gore) (n=5) as main grafts, and Advanta V12 (n=14) as the bridging device. CONCLUSIONS: This systematic review presents a broad analysis of the current in vitro methods evaluating the endovascular treatment of jAAA. Fundamental issues have been benchtop tested in both FEVAR and PGs. The analysis of the included studies allowed to recommend an optimal testing design. In vitro testing is a potential tool to further elucidate points of attention hard to investigate in vivo to finally enhance the endovascular treatment outcomes. Future in vitro studies are needed to evaluate the in vitro performance of all indistinctively used devices in the clinical practice.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Stents , Procedimientos Endovasculares/efectos adversos , Diseño de Prótesis , Estudios Retrospectivos
3.
J Endovasc Ther ; : 15266028231209929, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37933525

RESUMEN

OBJECTIVE: The performance of fenestrated endovascular aortic aneurysm repair (FEVAR) may be compromised by complications related to the dynamic vascular environment. The aim of this study was to analyze the behavior of FEVAR bridging stent configurations during the cardiac cycle and during follow-up to improve our understanding on treatment durability. DESIGN: Twenty-one patients presenting with complex abdominal aortic aneurysms (AAAs; 9 juxtarenal/6 pararenal/3 paravisceral/1 thoracoabdominal aortic aneurysm type IV), treated with a fenestrated Anaconda (Terumo Aortic, Inchinnan, Scotland, UK) with Advanta V12 bridging stents (Getinge, Merrimack, NH, USA), were prospectively enrolled in a multicenter observational cohort study and underwent electrocardiogram (ECG)-gated computed tomographic angiography (CTA) preoperatively, at discharge, 7-week, and 12-month follow-ups. METHODS: Fenestrated endovascular aortic aneurysm repair stability was assessed considering the following variables: branch angle as the angle between the aorta and the target artery, end-stent angle as the angle between the end of the bridging stent and the native artery downstream from it, curvature and tortuosity index (TI) to describe the bending of the target artery. Body-bridging stent stability was assessed considering bridging stent flare lengths, the distances between the proximal sealing stent-ring and fenestrations and the distance between the fenestration and first apposition in the target artery. RESULTS: Renal branch angles significantly increased after FEVAR toward a perpendicular position (right renal artery from median 60.9°, inter quartile range [IQR]=44.2-84.9° preoperatively to 94.4°, IQR=72.6-99.8°, p=0.001 at 12-month follow-up; left renal artery [LRA], from 63.7°, IQR=55.0-73.0° to 94.3°, IQR=68.2-105.6°, p<0.001), while visceral branch angles did not. The mean dynamic curvature only decreased for the LRA from preoperative (3.0, IQR=2.2-3.8 m-1) to 12-month follow-up (1.9, IQR=1.4-2.6 m-1, p=0.027). The remaining investigated variables did not seem to show any changes over time in this cohort. CONCLUSIONS: Fenestrated endovascular aortic aneurysm repair for complex AAAs using the Anaconda fenestrated stent-graft and balloon-expandable Advanta V12 bridging stents demonstrated stable configurations up to 12-month follow-up, except for increasing renal branch angles toward perpendicular orientation to the aorta, yet without apparent clinical consequences in this cohort. CLINICAL IMPACT: This study provides detailed information on the cardiac-pulsatility-induced (dynamic) and longitudinal geometry deformations of the target arteries and bridging stents after fenestrated endovascular aortic aneurysm repair (FEVAR) up to 12-month follow-up. The configuration demonstrated limited dynamic and longitudinal deformations in terms of branch angle, end-stent angle, curvature, and tortuosity index (TI), except for the increasing renal branch angles that go toward a perpendicular orientation to the aorta. Overall, the results suggest that the investigated FEVAR configurations are stable and durable, though careful consideration of increasing renal branch angles and significant geometry alterations is advised.

4.
J Endovasc Ther ; : 15266028231219988, 2023 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-38149463

RESUMEN

PURPOSE: To identify potential hemodynamic predictors for limb thrombosis (LT) following endovascular aneurysm repair with the Anaconda endograft in a patient-specific phantom. MATERIALS AND METHODS: A thin-walled flow phantom, based on a patient's aortic anatomy and treated with an Anaconda endograft, that presented with a left-sided LT was fabricated. Contrast-enhanced ultrasound particle image velocimetry was performed to quantify time-resolved velocity fields. Measurements were performed in the same phantom with and without the Anaconda endograft, to investigate the impact of the endograft on the local flow fields. Hemodynamic parameters, namely vector complexity (VC) and residence time (RT), were calculated for both iliac arteries. RESULTS: In both limbs, the vector fields were mostly unidirectional during the peak systolic and end-systolic velocity phases before and after endograft placement. Local vortical structures and complex flow fields were observed at the diastolic and transitional flow phases. The average VC was higher (0.11) in the phantom with endograft, compared to the phantom without endograft (0.05). Notably, in both left and right iliac arteries, the anterior wall regions corresponded to a 2- and 4-fold increase in VC in the phantom with endograft, respectively. RT simulations showed values of 1.3 to 6 seconds in the phantom without endograft. A higher RT (up to 25 seconds) was observed in the phantom with endograft, in which the left iliac artery, with LT in follow-up, showed 2 fluid stasis regions. CONCLUSION: This in vitro study shows that unfavorable hemodynamics were present mostly in the limb that thrombosed during follow-up, with the highest VC and longest RT. These parameters might be valuable in predicting the occurrence of LT in the future. CLINICAL IMPACT: This in-vitro study aimed to identify potential hemodynamic predictors for limb thrombosis following EVAR using ultrasound particle image velocimetry (echoPIV) technique. It was shown that unfavorable hemodynamic norms were present mostly in the thrombosed limb. Owing to the in-vivo feasibility of the echoPIV, future efforts should focus on the evaluation of these hemodynamic norms in clinical trials. Thereafter, using echoPIV as a bedside technique in hospitals becomes more promising. Performing echoPIV in pre-op phase may provide valuable insights for surgeons to enhance treatment planning. EchoPIV is also applicable for follow-up sessions to evaluate treatment progress and avoid/predict complications.

5.
Catheter Cardiovasc Interv ; 99(5): 1714-1722, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35253348

RESUMEN

OBJECTIVES: The aim of the study was to analyze available data on patients treated for chronic limb-threatening ischemia (CLTI) with the heparin-bonded Viabahn endoprosthesis. BACKGROUND: The patency of self-expanding covered stents in patients with complex femoropopliteal lesions is encouraging. However, data were mostly derived in patients with intermittent claudication. Patients with CLTI often have more advanced disease and worse outcome. METHODS: After the abstract screening, full-text papers were checked. Authors were approached to consider joining the consortium. Data were sent anonymously, databases were merged and an individual patient data meta-analysis was performed. Kaplan-Meier curves were used to calculate the freedom from amputations, the amputation-free survival, and patency rates. RESULTS: Seven studies were enrolled, representing 161 limbs that were treated for CLTI. Median lesion length was 28.0 cm (interquartile range 25.0-33.0 cm) and 82.7% were chronic total occlusions. The technical success rate was 98.1% and the 30-day mortality 1.9%. Through 2-year follow-up, the freedom-from-major-amputations was 99.3%, with an amputation-free survival of 78.8%. The freedom-from-loss-of primary, primary-assisted, and secondary patency was 70.4%, 71.8%, and 88.2%, respectively, at 1-year and 59.5%, 62.7%, and 86.1% at 2-year follow-up, respectively. The reintervention-free survival was 62.2% at a 2-year follow-up. CONCLUSIONS: Treatment of femoropopliteal disease in CLTI patients with the use of the heparin-bonded Viabahn is safe and effective with favorable clinical outcomes and low amputation rates. Reinterventions are needed in a subset of the population to maintain endoprosthesis patency. Close follow-up using duplex is recommended to detect potential edge stenosis, allowing treatment before device occlusion.


Asunto(s)
Implantación de Prótesis Vascular , Enfermedad Arterial Periférica , Amputación Quirúrgica , Prótesis Vascular , Isquemia Crónica que Amenaza las Extremidades , Arteria Femoral , Heparina/efectos adversos , Humanos , Isquemia/diagnóstico por imagen , Isquemia/etiología , Isquemia/terapia , Recuperación del Miembro , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Diseño de Prótesis , Resultado del Tratamiento , Grado de Desobstrucción Vascular
6.
Radiology ; 301(2): 332-338, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34427462

RESUMEN

Background The accurate quantification of blood flow in aortoiliac arteries is challenging but clinically relevant because local flow patterns can influence atherosclerotic disease. Purpose To investigate the feasibility and clinical application of two-dimensional blood flow quantification using high-frame-rate contrast-enhanced US (HFR-CEUS) and particle image velocimetry (PIV), or US velocimetry, in participants with aortoiliac stenosis. Materials and Methods In this prospective study, participants with a recently diagnosed aortoiliac stenosis underwent HFR-CEUS measurements of the pre- and poststenotic vessel segments (August 2018 to July 2019). Two-dimensional quantification of blood flow was achieved by performing PIV analysis, which was based on pairwise cross-correlation of the HFR-CEUS images. Visual inspection of the entire data set was performed by five observers to evaluate the ability of the technique to enable adequate visualization of blood flow. The contrast-to-background ratio and average vector correlation were calculated. In two participants who showed flow disturbances, the flow complexity and vorticity were calculated. Results Thirty-five participants (median age, 67 years; age range, 56-84 years; 22 men) were included. Visual scoring showed that flow quantification was achieved in 41 of 42 locations. In 25 locations, one or multiple issues occurred that limited optimal flow quantification, including loss of correlation during systole (n = 12), shadow regions (n = 8), a short vessel segment in the image plane (n = 7), and loss of contrast during diastole (n = 5). In the remaining 16 locations, optimal quantification was achieved. The contrast-to-background ratio was higher during systole than during diastole (11.0 ± 2.9 vs 6.9 ± 3.4, respectively; P < .001), whereas the vector correlation was lower (0.58 ± 0.21 vs 0.47 ± 0.13; P < .001). The flow complexity and vorticity were high in regions with disturbed flow. Conclusion Blood flow quantification with US velocimetry is feasible in patients with an aortoiliac stenosis, but several challenges must be overcome before implementation into clinical practice. Clinical trial registration no. NTR6980 © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Reología/métodos , Ultrasonografía/métodos , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Medios de Contraste , Estudios de Factibilidad , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
7.
J Endovasc Ther ; 28(4): 623-635, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34076554

RESUMEN

PURPOSE: To compare the flow patterns and hemodynamics of the AFX stent-graft and the covered endovascular reconstruction of aortic bifurcation (CERAB) configuration using laser particle image velocimetry (PIV) experiments. MATERIALS AND METHODS: Two anatomically realistic aortoiliac phantoms were constructed using polydimethylsiloxane polymer. An AFX stent-graft with a transparent cover made with a new method was inserted into one phantom. A CERAB configuration using Atrium's Avanta V12 with transparent covers made with a previously established method was inserted into the other phantom, both modified stent-grafts were suitable for laser PIV, enabling visualization of the flow fields and quantification of time average wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). RESULTS: Disturbed flow was observed at the bifurcation region of the AFX, especially at the end systolic velocity (ESV) time-point where recirculation was noticeable due to vortical flow. In contrast, predominantly unidirectional flow was observed at the CERAB bifurcation. These observations were confirmed by the quantified hemodynamic results from PIV analysis where mean TAWSS of 0.078 Pa (range: 0.009-0.242 Pa) was significantly lower in AFX as compared with 0.229 Pa (range: 0.013-0.906 Pa) for CERAB (p<0.001). Mean OSI of 0.318 (range: 0.123-0.496) in AFX was significantly higher than 0.252 (range: 0.055-0.472) in CERAB (p<0.001). Likewise, mean RRT of 180 Pa-1 (range: 9-3603 Pa-1) in AFX was also significantly higher than 88 Pa-1 (range: 2-840 Pa-1) in CERAB (p=0.0086). CONCLUSION: In this in vitro study, the flow pattern of a modified AFX stent-graft was found to be more disturbed especially at the end systolic phase, its hemodynamic outcomes less desirable than CERAB configuration. CLINICAL RELEVANCE: While the AFX stent-graft has an advantage over the CERAB configuration in eliminating radial mismatch, and maintaining the anatomical bifurcation for future endovascular intervention, this in vitro study revealed that the associated lower TAWSS, higher OSI and RRT may predispose to thrombosis and are, thus, less desirable as compared to a CERAB configuration. Further investigation is warranted to confirm whether these findings translate into the clinical setting.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Hemodinámica , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Diseño de Prótesis , Stents , Resultado del Tratamiento
8.
Vascular ; 29(3): 380-386, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32951560

RESUMEN

OBJECTIVE: Endovascular surgery is an important treatment modality in peripheral arterial disease. Digital subtraction angiography is the standard post revascularisation diagnostic tool to locate lesions and to evaluate the effect of an intervention. However, interpretation of digital subtraction angiography images is subjective and it is difficult to determine whether revascularisation has been sufficient for clinical improvement. A new technique is 2D perfusion angiography, which creates a 2D colour map and time density curve from the digital subtraction angiography scan for an objective evaluation of the results. However, its clinical relevance is unknown. The aim is to evaluate the association between 2D perfusion angiography parameters and clinical outcome after peripheral arterial interventions. METHODS: In this retrospective study, post revascularisation angiographic data and clinical data were reviewed of patients who underwent treatment of femoral-popliteal or femoral-tibial arteries. The outcome was assessed at three time points using three classification systems for peripheral arterial disease: Fontaine classification, American Medical Association whole person impairment classification (AMA) and average wound, ischemia, foot infection score. Post revascularisation angiographic data consisted of time density curves of the foot and lower leg which were extracted from the Syngo iFlow system (Siemens Healthineers). For each time density curve, five descriptive parameters were calculated: time of arrival, time to peak, mean transit time, wash-in rate and area under the curve. The association between the time density curve parameters and peripheral arterial disease classification systems was assessed using a regression analysis. RESULTS: Between July 2016 and December 2018, 103 patients underwent peripheral endovascular interventions in the hybrid operating room; 39 patients were suitable for analysis, of which 28 patients underwent digital subtraction angiography of the lower leg, 3 patients underwent digital subtraction angiography of the foot and 8 patients underwent digital subtraction angiography of both regions. Limited significant relations were found for time of arrival with Fontainde classification (B = 0.806, p = 0.043) and area under the curve with AMA classification (B = -0.027, p = 0.047). CONCLUSION: In this retrospective study, time density curve parameters (time of arrival and area under the curve), measured in the lower leg, showed a limited significant association with two classification systems for peripheral arterial disease. Future prospective studies to determine the clinical relevance of this 2D perfusion angiography method should focus on standardisation of angiography protocols and comparison of pre- and post-intervention parameters.


Asunto(s)
Angiografía de Substracción Digital , Procedimientos Endovasculares , Extremidad Inferior/irrigación sanguínea , Imagen de Perfusión , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Anciano , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
9.
J Endovasc Ther ; 27(3): 509-515, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32295455

RESUMEN

Purpose: To investigate the physiological uptake of hybrid fluorine-18-fluorodeoxyglucose (FDG)-positron emission tomography/computed tomography (PET/CT) before and after an uncomplicated endovascular aneurysm sealing (EVAS) procedure as a possible tool to diagnose EVAS graft infection and differentiate from postimplantation syndrome. Materials and Methods: Eight consecutive male patients (median age 78 years) scheduled for elective EVAS were included in the prospective study (ClinicalTrials.gov identifier NCT02349100). FDG-PET/CT scans were performed in all patients before the procedure and 6 weeks after EVAS. The abdominal aorta was analyzed in 4 regions: suprarenal, infrarenal neck, aneurysm sac, and iliac. The following parameters were obtained for each region: standard uptake value (SUV), tissue to background ratio (TBR), and visual examination of FDG uptake to ascertain its distribution. Demographic data were obtained from medical files and scored based on reporting standards. Results: Visual examination showed no difference between pre- and postprocedure FDG uptake, which was homogenous. In the suprarenal region no significant pre- and postprocedure differences were observed for the SUV and TBR parameters. The infrarenal neck region showed a significant decrease in the SUV and no significant decrease in the TBR. The aneurysm sac and iliac regions both showed a significant decrease in SUV and TBR between the pre- and postprocedure scans. Conclusion: Physiological FDG uptake after EVAS was stable or decreased with regard to the preprocedure measurements. Future research is needed to assess the applicability and cutoff values of FDG-PET/CT scanning to detect endograft infection after EVAS.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Fluorodesoxiglucosa F18/administración & dosificación , Tomografía Computarizada por Tomografía de Emisión de Positrones , Complicaciones Posoperatorias/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Radiofármacos/administración & dosificación , Anciano , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Diagnóstico Diferencial , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/microbiología , Reproducibilidad de los Resultados , Resultado del Tratamiento
10.
Artif Organs ; 44(8): 818-826, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32065666

RESUMEN

Having physiological correct flow waveforms is a key feature for experimental studies of blood flow, especially in the process of developing and testing a new medical device such as stent, mechanical heart valve, or any implantable medical device that involves circulation of blood through the device. It is also a critical part of a perfusion system for cardiopulmonary bypass and extracorporeal membrane oxygenation procedures. This study investigated the feasibility of a novel roller pump for use in experimental flow phantoms. Flow rates of carotid flow profile measured directly with the ultrasonic flow meter matched well with the reference flow rates programmed into the machine with similarity index of 0.97 and measured versus programmed flow rates at specific time-points of peak systolic velocity (PSV): 0.894 vs 0.880, end systolic velocity (ESV): 0.333 vs 0.319, and peak diastolic velocity (PDV): 0.514 vs 0.520 L/min. Flow rates derived from video analysis of the pump motion for carotid, suprarenal, and infrarenal flows also matched well with references with similarity indices of 0.99, 0.99, and 0.96, respectively. Measured flow rates (mean/standard deviation) at PSV, ESV, and PDV time-points for carotid: 0.883/0.016 vs 0.880, 0.342/0.007 vs 0.319, and 0.485/0.009 vs 0.520; suprarenal: 3.497/0.014 vs 3.500, 0.004/0.003 vs 0, and 1.656/0.073 vs 1.453; infrarenal: 4.179/0.024 vs 4.250, -1.147/0.015 vs -1.213, and 0.339/0.017 vs 0.391 L/min, respectively. The novel roller pump is suitable for benchtop testing of physiological flow.


Asunto(s)
Circulación Sanguínea/fisiología , Corazón Auxiliar , Arterias Carótidas/fisiología , Humanos , Modelos Biológicos , Diseño de Prótesis , Arteria Renal/fisiología
11.
J Endovasc Ther ; 26(1): 31-40, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30499352

RESUMEN

PURPOSE: To evaluate short- and long-term technical and clinical outcomes after kissing stent treatment of aortoiliac occlusive disease (AIOD) based on an individual participant data (IPD) meta-analysis. MATERIALS AND METHODS: A search of the Scopus database identified 156 articles on KS treatment of AIOD; of these 22 met the inclusion criteria. Authors of 19 articles with contact information were approached to join an IPD consortium. Eight author groups responded and 5 provided anonymized data for merging into an IPD database. The number of included procedures was equal before and after 2005. The primary study outcome was the cumulative patency at 24 months. Secondary outcomes were patency at up to 60 months, complications, and changes in Rutherford category and ankle-brachial index. The predictive value of stent protrusion length, pre-/postdilation, stent type, and patient demographics on primary patency were examined with Cox proportional hazard modeling; outcomes are reported as the hazard ratio (HR). The Kaplan-Meier method was employed to estimate patency rates. RESULTS: In total, 605 (40.9%) of 1480 patients presented in the literature were included in the IPD analysis. The indication for intervention was intermittent claudication in 84.2% and critical limb ischemia in 15.8%. Lesions were classified as TransAtlantic Inter-Society Consensus (TASC) A or B in 52.8% and TASC C and D in 47.2%. The overall primary patency estimate was 81% at 24 months. Primary patency significantly increased after 2005 (p=0.005). Cox regression analysis revealed only age as a significant predictor of sustained primary patency (HR 0.60, p<0.005). Any previous endovascular intervention (HR 2.52, p=0.02) was the main predictor for loss of secondary patency; history of cardiovascular disease (HR 0.27, p=0.04) was the main predictor of sustained secondary patency. CONCLUSION: The kissing stent technique has a good safety profile and acceptable patency rates up to 2 years, even in TASC C and D lesions, supporting an endovascular-first approach for AIOD.


Asunto(s)
Enfermedades de la Aorta/terapia , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca , Claudicación Intermitente/terapia , Isquemia/terapia , Enfermedad Arterial Periférica/terapia , Stents , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Constricción Patológica , Enfermedad Crítica , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Claudicación Intermitente/diagnóstico por imagen , Claudicación Intermitente/fisiopatología , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Diseño de Prótesis , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
12.
Eur J Vasc Endovasc Surg ; 57(5): 709-718, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31000458

RESUMEN

OBJECTIVE: Customised aortic repair (CAR) is a new and minimally invasive technique for the endovascular treatment of abdominal aortic aneurysms (AAAs). The aneurysm is completely sealed with a non-contained, non-cross linked polymer, while a new flow lumen is created with balloons. For CAR, the haemodynamically most favourable balloon and flow lumen configuration has not been established before; therefore, four flow parameters were assessed in an in vitro model. METHODS: Three in vitro balloon configurations were implanted in an in vitro AAA model; a configuration with crossing balloons (CC) and two parallel configurations (PC1 and PC2). These three models were consecutively placed in a flow system that mimics physiological flow conditions. Laser particle imaging velocimetry (PIV) was used to resolve spatial and temporal flow patterns during the cardiac cycle. In house built algorithms were used to analyse the PIV data for the computing of (i) flow velocity; (ii) vorticity; (iii) wall shear stress (WSS); and (iv) time averaged wall shear stress (TAWSS). RESULTS: Suprarenal flow patterns were similar in all models. The CC showed a higher infrarenal velocity than PC1 and PC2 (38 cm/s vs. 23 cm/s vs. 23 cm/s), and a higher vorticity at the crossing of the lumens (CC: 337/s; PC1 127/s; PC2: 112/s). The lowest vorticity was observed in PC2, especially in the infrarenal neck (CC: 200/s; PC1 164/s; PC2: 98/s). Although WSS and TAWSS varied between configurations, values were in the within non-pathological range. CONCLUSION: The flow lumens created by three balloon configurations used in an in vitro model of CAR have been studied, and resulted in different haemodynamics. The differences in velocity and lower vorticity, especially at the crossing section of the two balloons, showed that PC2 has favourable haemodynamics compared with the CC and PC1. Future research will be focused on the clinical applicability of CAR based on the PC2 design.


Asunto(s)
Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Algoritmos , Velocidad del Flujo Sanguíneo , Implantación de Prótesis Vascular/instrumentación , Hemodinámica , Humanos , Modelos Cardiovasculares , Diseño de Prótesis , Flujo Sanguíneo Regional , Stents , Estrés Mecánico
13.
Radiology ; 289(1): 119-125, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30015586

RESUMEN

Purpose To study the feasibility of high-frame-rate (HFR) contrast material-enhanced (CE) ultrasound particle image velocimetry (PIV), or echo PIV, in the abdominal aorta. Materials and Methods Fifteen healthy participants (six men; median age, 23 years [age range, 18-34 years]; median body mass index, 20.3 kg/m2 [range, 17.3-24.9 kg/m2]) underwent HFR CE US. US microbubbles were injected at incremental doses (0.25, 0.5, 0.75, and 1.5 mL), with each dose followed by US measurement to determine the optimal dosage. Different US mechanical index values were evaluated (0.09, 0.06, 0.03, and 0.01) in a diverging wave acquisition scheme. PIV analysis was performed via pairwise cross-correlation of all captured images. Participants also underwent phase-contrast MRI. The echo PIV and phase-contrast MRI velocity profiles were compared via calculation of similarity index and relative difference in peak velocity. Results Visualization of the aortic bifurcation with HFR CE US was successful in all participants. Optimal echo PIV results were achieved with the lowest contrast agent dose of 0.25 mL in combination with the lowest mechanical indexes (0.01 or 0.03). Substantial bubble destruction occurred at higher mechanical indexes (≥0.06). Flow patterns were qualitatively similar in the echo PIV and MR images. The echo PIV and MRI velocity profiles showed good agreement (similarity index, 0.98 and 0.99; difference in peak velocity, 8.5% and 17.0% in temporal and spatial profiles, respectively). Conclusion Quantification of blood flow in the human abdominal aorta with US particle image velocimetry (echo PIV) is feasible. Use of echo PIV has potential in the clinical evaluation of aortic disease. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Reología/métodos , Ultrasonografía/métodos , Adolescente , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Adulto Joven
14.
J Vasc Surg ; 67(5): 1438-1447, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29169878

RESUMEN

OBJECTIVE: The objective of this study was to demonstrate the 3-year outcome of the covered endovascular reconstruction of the aortic bifurcation (CERAB) technique for the treatment of extensive aortoiliac occlusive disease (AIOD). METHODS: Between February 2009 and July 2016, all patients treated with the CERAB technique for AIOD were identified in the local databases of two centers and analyzed. Demographics and lesion characteristics were scored. Follow-up consisted of clinical assessment, duplex ultrasound, and ankle-brachial indices. Patency rates and clinically driven target lesion revascularization were calculated by Kaplan-Meier analysis. RESULTS: Of 130 patients (69 male and 61 female) treated, 68% were diagnosed with intermittent claudication and 32% suffered from critical limb ischemia. The majority (89%) were TransAtlantic Inter-Society Consensus II D lesions, and the remaining were B and C lesions (both 5%). Median follow-up was 24 months (range, 0-67 months). The technical success rate was 97%, and 67% of cases were performed completely percutaneously. The ankle-brachial index improved significantly from 0.65 ± 0.22 preoperatively to 0.88 ± 0.15 after the procedure. The 30-day minor and major complication rate was 33% and 7%. The median hospital stay was 2 days (range, 1-76 days). At 1 year and 3 years of follow-up, 94% and 96% of the patients clinically improved at least one Rutherford category (2% and 0% unchanged, 4% and 4% worsened). Limb salvage rate was 98% at 1 year and 97% at 3 years of follow-up. Primary, primary assisted, and secondary patency was 86%, 91%, and 97% at 1 year; 84%, 89%, and 97% at 2 years; and 82%, 87%, and 97% at 3 years. Freedom from clinically driven target lesion revascularization was 87% at 1-year follow-up and 86% at both 2-year and 3-year follow-up. CONCLUSIONS: The CERAB technique is a safe and feasible technique for the treatment of extensive AIOD with good 3-year results regarding patency and clinical improvement.


Asunto(s)
Enfermedades de la Aorta/cirugía , Arteriopatías Oclusivas/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Stents , Adulto , Anciano , Anciano de 80 o más Años , Índice Tobillo Braquial , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Aortografía/métodos , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Bélgica , Implantación de Prótesis Vascular/efectos adversos , Distribución de Chi-Cuadrado , Procedimientos Endovasculares/efectos adversos , Femenino , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Estimación de Kaplan-Meier , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Países Bajos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
15.
J Vasc Surg ; 67(5): 1585-1594, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28893490

RESUMEN

OBJECTIVE: To achieve an optimal sealing zone during endovascular aneurysm repair, the intended positioning of the proximal end of the endograft fabric should be as close as possible to the most caudal edge of the renal arteries. Some endografts exhibit a small offset between the radiopaque markers and the proximal fabric edge. Unintended partial renal artery coverage may thus occur. This study investigated the consequences of partial coverage on renal flow patterns and wall shear stress (WSS). METHODS: In vitro models of an abdominal aortic aneurysm were used to visualize pulsatile flow using two-dimensional particle image velocimetry under physiologic resting conditions. One model served as control and two models were stented with an Endurant endograft (Medtronic Inc, Minneapolis, Minn), one without and one with partial renal artery coverage with 1.3 mm of stent fabric extending beyond the marker (16% area coverage). The magnitude and oscillation of WSS, relative residence time, and backflow in the renal artery were analyzed. RESULTS: In both stented models, a region along the caudal renal artery wall presented with low and oscillating WSS, not present in the control model. A region with very low WSS (<0.1 Pa) was present in the model with partial coverage over a length of 7 mm compared with a length of 2 mm in the model without renal coverage. Average renal backflow area percentage in the renal artery incrementally increased from control (0.9%) to the stented model without (6.4%) and with renal coverage (18.8%). CONCLUSIONS: In this flow model, partial renal coverage after endovascular aneurysm repair causes low and marked oscillations in WSS, potentially promoting atherosclerosis and subsequent renal artery stenosis. Awareness of the device-dependent offset between the fabric edge and the radiopaque markers is therefore important in endovascular practice.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Modelos Anatómicos , Modelos Cardiovasculares , Arteria Renal/cirugía , Circulación Renal , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Velocidad del Flujo Sanguíneo , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Humanos , Diseño de Prótesis , Arteria Renal/diagnóstico por imagen , Arteria Renal/fisiopatología , Obstrucción de la Arteria Renal/etiología , Obstrucción de la Arteria Renal/fisiopatología , Factores de Riesgo , Stents , Estrés Mecánico , Factores de Tiempo
16.
J Endovasc Ther ; 25(3): 387-394, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29544371

RESUMEN

PURPOSE: To assess the dynamic behavior of chimney grafts during the cardiac cycle. METHODS: Three chimney endovascular aneurysm repair (EVAR) stent-graft configurations (Endurant and Advanta V12, Endurant and Viabahn, and Endurant and BeGraft) were placed in silicone aneurysm models and subjected to physiologic flow. Electrocardiography (ECG)-gated contrast-enhanced computed tomography was used to visualize geometric changes during the cardiac cycle. Endograft and chimney graft surface, gutter volume, chimney graft angulation over the center lumen line, and the D-ratio (the ratio between the lengths of the major and minor axes) were independently assessed by 2 observers at 10 time points in the cardiac cycle. RESULTS: Both gutter volumes and chimney graft geometry changed significantly during the cardiac cycle in all 3 configurations (p<0.001). Gutters and endoleaks were observed in all configurations. The largest gutter volume (232.8 mm3) and change in volume (20.7 mm3) between systole and diastole were observed in the Endurant-Advanta configuration. These values were 2.7- and 3.0-fold higher, respectively, compared to the Endurant-Viabahn configuration and 1.7- and 1.6-fold higher as observed in the Endurant-BeGraft configuration. The Endurant-Viabahn configuration had the highest D-ratio (right, 1.26-1.35; left, 1.33-1.48), while the Endurant-BeGraft configuration had the lowest (right, 1.11-1.17; left, 1.08-1.15). Assessment of the interobserver variability showed a high correlation (intraclass correlation >0.935) between measurements. CONCLUSION: Gutter volumes and stent compression are dynamic phenomena that reshape during the cardiac cycle. Compelling differences were observed during the cardiac cycle in all configurations, with the self-expanding (Endurant-Viabahn) chimney EVAR configurations having smaller gutters and less variation in gutter volume during the cardiac cycle yet more stent compression without affecting the chimney graft surface.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Técnicas de Imagen Sincronizada Cardíacas , Electrocardiografía , Procedimientos Endovasculares/instrumentación , Tomografía Computarizada Multidetector , Stents , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Presión Arterial , Ensayo de Materiales , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis , Flujo Pulsátil
17.
Vascular ; 26(2): 198-202, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28820356

RESUMEN

Objectives Correct sizing of endoprostheses used for the treatment of abdominal aortic aneurysms is important to prevent endoleaks and migration. Sizing requires several steps and each step introduces a possible sizing error. The goal of this study was to investigate the magnitude of these errors compared to the golden standard: a vessel phantom. This study focuses on the errors in sizing with three different brands of computed tomography angiography scanners in combination with three reconstruction software packages. Methods Three phantoms with a different diameter, altitude and azimuth were scanned with three computed tomography scanners: Toshiba Aquilion 64-slice, Philips Brilliance iCT 256-slice and Siemens Somatom Sensation 64-slice. The phantom diameters were determined in the stretched view after central lumen line reconstruction by three observers using Simbionix PROcedure Rehearsal Studio, 3mensio and TeraRecon planning software. The observers, all novices in sizing endoprostheses using planning software, measured 108 slices each. Two senior vascular surgeons set the tolerated error margin of sizing on ±1.0 mm. Results In total, 11.3% of the measurements (73/648) were outside the set margins of ±1.0 mm from the phantom diameter, with significant differences between the scanner types (14.8%, 12.1%, 6.9% for the Siemens scanner, Philips scanner and Toshiba scanner, respectively, p-value = 0.032), but not between the software packages (8.3%, 11.1%, 14.4%, p-value = 0.141) or the observers (10.6%, 9.7%, 13.4%, p-value = 0.448). Conclusions It can be concluded that the errors in sizing were independent of the used software packages, but the phantoms scanned with Siemens scanner were significantly more measured incorrectly than the phantoms scanned with the Toshiba scanner. Consequently, awareness on the type of computed tomography scanner and computed tomography scanner setting is necessary, especially in complex abdominal aortic aneurysms sizing for fenestrated or branched endovascular aneurysm repair if appropriate the sizing is of upmost importance.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/instrumentación , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada/instrumentación , Procedimientos Endovasculares , Tomografía Computarizada Multidetector/instrumentación , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Tomógrafos Computarizados por Rayos X , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Toma de Decisiones Clínicas , Procedimientos Endovasculares/instrumentación , Diseño de Equipo , Humanos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Stents
18.
J Vasc Surg ; 66(1): 251-260.e1, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-27743806

RESUMEN

BACKGROUND: Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry seems to affect patency. These variations may affect local flow patterns, resulting in different wall shear stress (WSS) and oscillating shear index (OSI). The aim of this study was to compare the effect of different stent configurations on flow perturbations (recirculation and fluid stasis), WSS, and OSI in an in vitro setup. METHODS: Three different stent configurations were deployed in transparent silicone models: bare-metal kissing (BMK) stents, covered kissing (CK) stents, and the covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration. Transparent covered stents were created with polyurethane to enable visualization. Models were placed in a circulation setup under physiologic flow conditions. Time-resolved laser particle image velocimetry techniques were used to quantify the flow, and WSS and OSI were calculated. RESULTS: The BMK configuration did not show flow disturbances at the inflow section, and WSS values were similar to the control. An area of persistent low flow was observed throughout the cardiac cycle in the area between the anatomic bifurcation and neobifurcation. The CK model showed recirculation zones near the inflow area of the stents with a resulting low average WSS value and high OSI. The proximal inflow of the CERAB configuration did not show flow disturbances, and WSS values were comparable to control. Near the inflow of the limbs, a minor zone of recirculation was observed without changes in WSS values. Flow, WSS, and OSI on the lateral wall of the proximal iliac artery were undisturbed in all models. CONCLUSIONS: The studied aortoiliac stent configurations have distinct locations where flow disturbances occur, and these are related to the radial mismatch. The CERAB configuration is the most unimpaired physiologic reconstruction, whereas BMK and CK stents have their typical zones of flow recirculation.


Asunto(s)
Angioplastia de Balón/instrumentación , Enfermedades de la Aorta/terapia , Arteriopatías Oclusivas/terapia , Hemodinámica , Arteria Ilíaca/fisiopatología , Stents , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/fisiopatología , Velocidad del Flujo Sanguíneo , Constricción Patológica , Humanos , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis , Flujo Sanguíneo Regional , Factores de Tiempo
19.
J Vasc Surg ; 66(2): 594-599, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27743807

RESUMEN

OBJECTIVE: Gutters can be described as the loss of continuous apposition between the main body of the endograft, the chimney stent graft, and the aortic wall. Gutters have been associated with increased risk of type IA endoleaks and are considered to be the Achilles' heel of chimney endovascular aneurysm repair (ch-EVAR). However, there is no classification yet to classify and quantify gutter types after ch-EVAR. METHODS: Different gutter types can be distinguished by their morphologic appearance in two- and three-dimensional views and reconstructed slices perpendicular to the center lumen line. RESULTS: Three main categories are defined by (1) the most proximal beginning of the gutter, (2) the length of gutter alongside the endograft, and (3) its distal end. Type A gutters originate at the proximal fabric of an endograft, type B gutters originate as loss of apposition of the chimney stent graft in the branch vessel, and type C gutters start below the fabric of the endograft. To determine eventual changes of gutter size during follow-up computed tomography angiograms (CTAs), measurements may be performed with dedicated software on the follow-up CTA scan to assess the extent of gutters over the aortic circumference, ranging from 0° to 360° of freedom, together with the maximum gap between the endograft material and the aortic wall as it appears on reconstructed axial CTA scan slices. CONCLUSIONS: The proposed gutter classification enables a uniform nomenclature in the current ch-EVAR literature and a more accurate risk assessment of gutter-associated endoleaks. Moreover, it allows monitoring of eventual progression of gutter size during follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Falla de Prótesis , Stents , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Humanos , Imagenología Tridimensional , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Terminología como Asunto , Resultado del Tratamiento
20.
J Vasc Surg ; 66(5): 1565-1573.e1, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-27988156

RESUMEN

BACKGROUND: The chimney technique has been successfully used to treat juxtarenal aortic aneurysms. The two main issues with this technique are gutter formation and chimney graft (CG) compression, which induce a risk for type Ia endoleaks and stent thrombosis, respectively. In this benchtop study, the geometry and renal artery flow of chimney endovascular aneurysm repair configurations were compared with chimney configurations with endovascular aneurysm sealing (ch-EVAS). METHODS: Seven flow phantoms were constructed, including one control and six chimney endovascular aneurysm repairs (Endurant [Medtronic Inc, Minneapolis, Minn] and AFX [Endologix Inc, Irvine, Calif]) or ch-EVAS (Nellix, Endologix) configurations, combined with either balloon-expandable or self-expanding CGs with an intended higher positioning of the right CG in comparison to the left CG. Geometric analysis was based on measurements at three-dimensional computed tomography angiography and included gutter volume and CG compression, quantified by the ratio between maximal and minimal diameter (D-ratio). In addition, renal artery flow was studied in a physiologic flow model and compared with the control. RESULTS: The average gutter volume was 343.5 ± 142.0 mm3, with the lowest gutter volume in the EVAS-Viabahn (W. L. Gore & Associates, Flagstaff, Ariz) combination (102.6 mm3) and the largest in the AFX-Advanta V12 (Atrium Medical Corporation, Hudson, NH) configuration (559.6 mm3). The maximum D-ratio was larger in self-expanding CGs than in balloon-expandable CGs in all configurations (2.02 ± 0.34 vs 1.39 ± 0.13). The CG compression had minimal influence on renal volumetric flow (right, 390.7 ± 29.4 mL/min vs 455.1 mL/min; left, 423.9 ± 28.3 mL/min vs 410.0 mL/min in the control). CONCLUSIONS: This study showed that gutter volume was lowest in ch-EVAS in combination with a Viabahn CG. CG compression was lower in configurations with the Advanta V12 than with Viabahn. Renal flow is unrestricted by CG compression.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Modelos Cardiovasculares , Arteria Renal/fisiopatología , Circulación Renal , Stents , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Endofuga/etiología , Endofuga/fisiopatología , Procedimientos Endovasculares/efectos adversos , Humanos , Ensayo de Materiales , Modelos Anatómicos , Diseño de Prótesis , Arteria Renal/diagnóstico por imagen , Factores de Riesgo , Trombosis/etiología , Trombosis/fisiopatología , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA