1.
J Radiol Prot ; 36(1): 104-16, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26807676

RESUMEN

Seven different types of radon detectors (Atmos 12 dpx, RAD7, RStone, Sun Nuclear 1028, Ramon 2.2, Canary and CR-39) were compared for exposure periods of 1, 2, 3 and 4 weeks. The comparison was conducted under two conditions: (a) in a purpose-built radon chamber with an average radon concentration of 2560 Bq m(-3) (b) in a home environment with a radon concentration of 57 Bq m(-3), in both cases measured by the reference detector (Atmos 12 dpx) with a ±10% uncertainty range. In (a) 5 out of 8 detectors recorded radon concentrations within the Atmos uncertainty range and all detectors recorded within ±15%; in (b) 3 out of 9 detectors recorded within the Atmos uncertainty range and 6 out of 9 measured within ±20%, for a 4 week measurement. The results from this study show that radon surveys can be conducted for shorter periods than the recommended 3 months where a rapid indication is needed of whether the radon concentration is above the reference level, such as when assessing the concentration during and after remediation work.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Monitoreo de Radiación/instrumentación , Radón/análisis
2.
J Radiol Prot ; 34(2): 457-67, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24894188

RESUMEN

Long term outdoor radon measurements were recorded in Ireland using CR-39 track etch detectors. A measurement protocol was designed for this study, which was optimized for the relatively low radon concentrations expected outdoors. This protocol included pre-etching the detectors before exposure to allow radon tracks to be more easily distinguished from background. The average outdoor radon concentration for the Republic of Ireland was found to be 5.6 ± 0.7 Bq m(-3). A statistically significant difference between inland and coastal radon concentrations was evident but no difference between mean radon concentrations on the east coast and those on the west coast was observed.


Asunto(s)
Algoritmos , Radiación de Fondo , Dispositivos Ópticos , Monitoreo de Radiación/instrumentación , Radón/análisis , Diseño de Equipo , Análisis de Falla de Equipo , Irlanda , Reproducibilidad de los Resultados , Sensibilidad y Especificidad