Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Ophthalmol ; 24(1): 217, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773506

RESUMEN

BACKGROUND: Only seven cases of ocular Spiroplasma infection have been reported to date, all presenting as congenital cataracts with concomitant intraocular inflammation. We describe the first case of Spiroplasma infection initially presenting as a corneal infiltrate. CASE PRESENTATION: A 1-month-old girl was referred for a corneal infiltrate in the left eye. She presented in our hospital with unilateral keratouveitis. Examination showed a stromal corneal infiltrate and dense white keratic precipitates in the left eye. Herpetic keratouveitis was suspected and intravenous acyclovir therapy was initiated. Two weeks later, the inflammation in the left eye persisted and was also noticed in the right eye. Acute angle-closure glaucoma and a cataract with dilated iris vessels extending onto the anterior lens capsule developed in the left eye. The inflammation resolved after treatment with azithromycin. Iridectomy, synechiolysis and lensectomy were performed. Bacterial metagenomic sequencing (16 S rRNA) and transmission electron microscopy revealed Spiroplasma ixodetis species in lens aspirates and biopsy. Consequently, a diagnosis of bilateral Spiroplasma uveitis was made. CONCLUSIONS: In cases of congenital cataract with concomitant intraocular inflammation, Spiroplasma infection should be considered. The purpose of this case report is to raise awareness of congenital Spiroplasma infection as a cause of severe keratouveitis, cataract and angle-closure glaucoma in newborns. Performing molecular testing on lens aspirates is essential to confirm diagnosis. Systemic macrolides are suggested as the mainstay of treatment.


Asunto(s)
Catarata , Infecciones Bacterianas del Ojo , Spiroplasma , Uveítis , Humanos , Femenino , Infecciones Bacterianas del Ojo/diagnóstico , Infecciones Bacterianas del Ojo/microbiología , Infecciones Bacterianas del Ojo/complicaciones , Catarata/congénito , Catarata/diagnóstico , Catarata/complicaciones , Uveítis/diagnóstico , Uveítis/microbiología , Uveítis/complicaciones , Spiroplasma/aislamiento & purificación , Queratitis/diagnóstico , Queratitis/microbiología , Recién Nacido , Antibacterianos/uso terapéutico , Lactante
2.
Microbiol Spectr ; 12(8): e0033224, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-38916332

RESUMEN

Clinically validated human papillomavirus (HPV) assays are crucial in cervical cancer screening. In this study, we evaluated the Allplex HPV HR Detection assay (Seegene, SouthKorea) for its clinical accuracy and reproducibility according to the international criteria, using the RealTime High Risk HPV m2000 assay (Abbott, USA) as standard comparator. The Allplex HPV HR assay exhibits significant non-inferior sensitivity to detect cervical intraepithelial neoplasia grade (CIN) 2 or worse (CIN2+) with a ratio of 1.00 (95% CI: 0.97-1.03, P = 0.006), insignificant non-inferior sensitivity to detect CIN3+ with a ratio of 1.00 (95% CI: 0.88-1.13, P = 0.098), and non-inferior specificity to exclude CIN2+ with a ratio of 0.99 (95% CI: 0.99-1.00, P < 0.001) compared to the standard comparator. In addition, the assay shows an excellent reproducibility within the same laboratory [96.5% (95% CI: 94.6-97.9) with a kappa value of 0.91 (95% CI: 0.87-0.95)] and between laboratories [96.7% (95% CI: 94.8-98.0) with a kappa value of 0.91 (95% CI: 0.87-0.95)] for overall high-risk HPV positivity as well as for each individual HPV type. Pooling our study data with those of another independent study supports the consistency of our findings. We conclude that both the clinical accuracy to detect cervical precancer and the reproducibility of Allplex HPV HR Detection assay fulfill the international validation criteria of use in cervical cancer screening.IMPORTANCEThe clinical validation of human papillomavirus (HPV) assays in accordance with well-established international guidelines is crucial to ensure that only validated assays are used in the context of screening (Meijer et al., Int J Cancer, 2009). The guidelines, developed by an international consortium, require that a novel HPV assay has non-inferior accuracy against a standard comparator test for the detection of cervical intraepithelial neoplasia grade (CIN) 2 or worse (CIN2+). Additionally, a new HPV assay should meet specific criteria for both intra- and inter-laboratory reproducibility to ensure the assay consistently exhibits technical precision and robust performance. Pooling our study data with those of another independent study supports the consistency of our findings. In conclusion, both the clinical accuracy to detect cervical precancer and the reproducibility of Allplex HPV HR Detection assay fulfill the international validation criteria of use in cervical cancer screening.


Asunto(s)
Detección Precoz del Cáncer , Papillomaviridae , Infecciones por Papillomavirus , Sensibilidad y Especificidad , Displasia del Cuello del Útero , Neoplasias del Cuello Uterino , Humanos , Femenino , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/virología , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/normas , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , Papillomaviridae/aislamiento & purificación , Papillomaviridae/genética , Reproducibilidad de los Resultados , Adulto , Displasia del Cuello del Útero/diagnóstico , Displasia del Cuello del Útero/virología , Persona de Mediana Edad , Adhesión a Directriz/estadística & datos numéricos , Anciano
3.
Acta Clin Belg ; : 1-7, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39101268

RESUMEN

OBJECTIVES: This study aimed to evaluate an expanded matrix-assisted laser desorption-ionization-time of flight mass spectrometry (MALDI-TOF MS) database for the identification of Haemophilus species other than H. influenzae (Hi). METHODS: A total of 144 Haemophilus species, cultured from respiratory samples from people (living) with cystic fibrosis, were identified with MALDI-TOF MS and 16S rRNA sequencing. Of these, 99 Haemophilus strains showed >99% similarity with the best matching strain in the National Center for Biotechnology Information (NCBI) database and were assigned to a single Haemophilus subspecies using both MALDI-TOF MS and 16S rRNA sequencing. The MS profiles of a subset of strains (n = 58/99) were added to the Bruker MALDI-TOF MS database. Subsequently, 270 different strains that were analyzed previously in a routine setting were re-analyzed. RESULTS: 16S rRNA sequencing reliably identified 99/144 Haemophilus strains (>99% similarity). H. haemolyticus 16S rRNA identification was suboptimal since only 3/21 H. haemolyticus strains attained a similarity of >99% with H. haemolyticus 16S rRNA sequence in the NCBI database. Expansion of the MALDI-TOF MS database improved the number of reliable identifications only moderately for H. haemolyticus, H. influenzae and H. paraphrohaemolyticus (<10%). By contrast, improved identification was more outspoken for H. parahaemolyticus, H. parainfluenzae, H. sputorum and H. pittmaniae (>85%). CONCLUSION: 16S rRNA sequencing is a valuable method for the identification of Haemophilus sp. other than Hi. Expansion of the MALDI-TOF MS database, based on 16S rRNA sequencing results, increased the proportion of reliable identifications and in this study resulted in an increase of 10% of Haemophilus sp. other than Hi strain identifications.

4.
EClinicalMedicine ; 71: 102563, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38686220

RESUMEN

Background: Dysregulation of the gut microbiome has been implicated in Parkinson's disease (PD). This study aimed to evaluate the clinical effects and safety of a single faecal microbiota transplantation (FMT) in patients with early-stage PD. Methods: The GUT-PARFECT trial, a single-centre randomised, double-blind, placebo-controlled trial was conducted at Ghent University Hospital between December 01, 2020 and December 12, 2022. Participants (aged 50-65 years, Hoehn and Yahr stage 2) were randomly assigned to receive nasojejunal FMT with either healthy donor stool or their own stool. Computer-generated randomisation was done in a 1:1 ratio through permutated-block scheduling. Treatment allocation was concealed for participants and investigators. The primary outcome measure at 12 months was the change in the Movement Disorders Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) motor score obtained during off-medication evaluations. Intention-to-treat analysis was performed using a mixed model for repeated measures analysis. This completed trial is registered on ClinicalTrials.gov (NCT03808389). Findings: Between December 2020 and December 2021, FMT procedures were conducted on 46 patients with PD: 22 in the healthy donor group and 24 in the placebo group. Clinical evaluations were performed at baseline, 3, 6, and 12 months post-FMT. Full data analysis was possible for 21 participants in the healthy donor group and 22 in the placebo group. After 12 months, the MDS-UPDRS motor score significantly improved by a mean of 5.8 points (95% CI -11.4 to -0.2) in the healthy donor group and by 2.7 points (-8.3 to 2.9) in the placebo group (p = 0.0235). Adverse events were limited to temporary abdominal discomfort. Interpretation: Our findings suggested a single FMT induced mild, but long-lasting beneficial effects on motor symptoms in patients with early-stage PD. These findings highlight the potential of modulating the gut microbiome as a therapeutic approach and warrant a further exploration of FMT in larger cohorts of patients with PD in various disease stages. Funding: Flemish PD patient organizations (VPL and Parkili), Research Foundation Flanders (FWO), Biocodex Microbiota Foundation.

5.
Antimicrob Resist Infect Control ; 12(1): 58, 2023 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-37337245

RESUMEN

BACKGROUND: Accumulating evidence shows a role of the hospital wastewater system in the spread of multidrug-resistant organisms, such as carbapenemase producing Enterobacterales (CPE). Several sequential outbreaks of CPE on the geriatric ward of the Ghent University hospital have led to an outbreak investigation. Focusing on OXA-48 producing Citrobacter freundii, the most prevalent species, we aimed to track clonal relatedness using whole genome sequencing (WGS). By exploring transmission routes we wanted to improve understanding and (re)introduce targeted preventive measures. METHODS: Environmental screening (toilet water, sink and shower drains) was performed between 2017 and 2021. A retrospective selection was made of 53 Citrobacter freundii screening isolates (30 patients and 23 environmental samples). DNA from frozen bacterial isolates was extracted and prepped for shotgun WGS. Core genome multilocus sequence typing was performed with an in-house developed scheme using 3,004 loci. RESULTS: The CPE positivity rate of environmental screening samples was 19.0% (73/385). Highest percentages were found in the shower drain samples (38.2%) and the toilet water samples (25.0%). Sink drain samples showed least CPE positivity (3.3%). The WGS data revealed long-term co-existence of three patient sample derived C. freundii clusters. The biggest cluster (ST22) connects 12 patients and 8 environmental isolates taken between 2018 and 2021 spread across the ward. In an overlapping period, another cluster (ST170) links eight patients and four toilet water isolates connected to the same room. The third C. freundii cluster (ST421) connects two patients hospitalised in the same room but over a period of one and a half year. Additional sampling in 2022 revealed clonal isolates linked to the two largest clusters (ST22, ST170) in the wastewater collection pipes connecting the rooms. CONCLUSIONS: Our findings suggest long-term circulation and transmission of carbapenemase producing C. freundii clones in hospital sanitary installations despite surveillance, daily cleaning and intermittent disinfection protocols. We propose a role for the wastewater drainage system in the spread within and between rooms and for the sanitary installations in the indirect transmission via bioaerosol plumes. To tackle this problem, a multidisciplinary approach is necessary including careful design and maintenance of the plumbing system.


Asunto(s)
Citrobacter freundii , Aguas Residuales , Humanos , Anciano , Citrobacter freundii/genética , Ingeniería Sanitaria , Estudios Retrospectivos , Hospitales , Células Clonales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA