Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1280-1283, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34891519

RESUMEN

'We present the development of a soft robotic-inspired device for lower limb compression therapy with application in the treatment of lymphedema. This device integrates the control capabilities of pneumatic devices with the wearability and low cost of compression garments. The design consists of a three-layered soft robotic sleeve that ensures safe skin contact, controls compression, and secures the device to the patient limb. The expandable component is made of interconnected pockets of various heights, which passively create a graduated compression profile along the lower limb. The system is inflated by a pump and a microcontroller-actuated valve, with force sensors embedded in the sleeve that monitor the pressure applied to the limb. Testing on healthy individualsq demonstrated the ability to reach clinically relevant target pressures (30, 40, 50 mmHg) and establish a distal-to-proximal descending pressure gradient of approximately 40 mmHg. Device function was shown to be robust against variations in subject anatomy.Clinical Relevance- This system provides controllable, graduated, compression therapy to lymphedema patients in an economical, portable, and customizable package.


Asunto(s)
Linfedema , Robótica , Humanos , Aparatos de Compresión Neumática Intermitente , Extremidad Inferior , Linfedema/terapia , Presión
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 6841-6844, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892678

RESUMEN

For hospitalized patients with pulmonary conditions, the onset of respiratory decline can occur unnoticed, due to the absence of a way to continuously and noninvasively monitor lung condition. Based on the relationship between lung volume and pleural pressure, we hypothesized that the time delay (∆t) between the start of a respiratory cycle and the occurrence of lung sounds associated with inspiration would correlate with lung volume. Additionally, we developed a re-search tool, consisting of a respiration belt, digital stethoscope, data collection system and MATLAB algorithm, to measure this delay. We conducted a feasibility study with three healthy individuals that involved safely manipulating lung volume, through subject position and activity, and plotting ∆t against volume measurements obtained via spirometry. The results indicated that ∆t was measurable and changed with lung volume and, therefore, has the potential to serve as a lung condition monitoring tool.


Asunto(s)
Frecuencia Respiratoria , Estetoscopios , Humanos , Pulmón , Ruidos Respiratorios , Espirometría
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4998-5004, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892330

RESUMEN

MIT's Emergency-Vent Project was launched in March 2020 to develop safe guidance and a reference design for a bridge ventilator that could be rapidly produced in a distributed manner worldwide. The system uses a novel servo-based robotic gripper to automate the squeezing of a manual resuscitator bag evenly from both sides to provide ventilation according to clinically specified parameters. In just one month, the team designed and built prototype ventilators, tested them in a series of porcine trials, and collaborated with industry partners to enable mass production. We released the design, including mechanical drawings, design spreadsheets, circuit diagrams, and control code into an open source format and assisted production efforts worldwide.Clinical relevance- This work demonstrated the viability of automating the compression of a manual resuscitator bag, with pressure feedback, to provide bridge ventilation support.


Asunto(s)
COVID-19 , Animales , Humanos , Respiración , Resucitación , SARS-CoV-2 , Porcinos , Ventiladores Mecánicos
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4016-4019, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-33018880

RESUMEN

Intravenous needle insertion is typically conducted manually, with needles guided into vessels by feel while looking for a brief flash of blood. This process is imprecise and leads to mispositioned needles, multiple reinsertion attempts, increased procedure time and higher costs for the hospital. We present a method for indicating that the needle has reached the vein by measuring the change in mechanical impedance of the needle as it passes through different tissue layers. Testing in a phantom indicated that this has the potential to identify transitions through tissue boundaries.


Asunto(s)
Agujas , Venas , Impedancia Eléctrica , Inyecciones Intravenosas , Fantasmas de Imagen
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4539-4542, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-33019003

RESUMEN

The mental and physiological stress experienced by surgeons during operations has been identified as an important human factor that impacts surgical performance and patient safety. It is crucial to objectively measure and quantify surgeons' stress via physiological signals in order to enhance the understanding of how stress contributes to surgical outcomes. Current clinical and consumer devices for monitoring bio signals are not well adapted for use in the operating room; therefore, we designed an unobtrusive system, that measures select signals that correlate with stress and stores the data for integration into a data processing pipeline. Herein, we present a proof-of-concept device that captures data from ECG, EMG, EDA, and IMU sensors and initial testing results.


Asunto(s)
Cirujanos , Dispositivos Electrónicos Vestibles , Humanos , Monitoreo Fisiológico , Quirófanos , Estrés Fisiológico
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 5771-5774, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30441647

RESUMEN

Driver fatigue is a cause of serious accidents for heavy machinery operators. Monitoring operator position, as indicated by their Center of Gravity (CoG), may be a means to non-invasively detect driver fatigue. We prototyped a research tool that tracks CoG from four sensors located within the legs of a seat, and validated its accuracy and precision. Our primary contributions are the development of a low-cost integrated CoG detector for seated drivers and the design of a flexure structure to protect load cells from shocks, tensile and shear forces. This system will enable research into CoG as an indicator of fatigue.


Asunto(s)
Prevención de Accidentes/instrumentación , Accidentes de Trabajo/prevención & control , Fatiga , Gravitación , Monitoreo Fisiológico , Humanos
7.
IEEE J Transl Eng Health Med ; 6: 2800406, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30042904

RESUMEN

Liquid medication overdose in pediatric patients results in over 70000 visits to the emergency room yearly in the USA. Various studies have demonstrated that the root cause of this high incidence is due to user and device error in dose measurement. The standard measuring cup and syringe suffer from the challenge of accurately measuring and dispensing viscous liquids, which comprise the majority of children's medication formulations. Here, we describe the development of a precision medication dispenser that overcomes challenges associated with viscous fluid flow at low volumes and flow rates, while incorporating various ergonomic and user-friendly features. The device performs with >95% accuracy and 94% precision across the 1-5-mL range of volume, a significant improvement when compared to current commercially available dispensers.

8.
IEEE Pulse ; 8(5): 31-35, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28961094

RESUMEN

A student squinting to see the board or holding a textbook inches from his or her nose often provides the first indication of a visual impairment. For most, the cause is a refractive error, readily correctible with eyeglasses. However, for an estimated 40-65 million people globally with functional low vision, the fuzzy words pose a lifelong challenge.


Asunto(s)
Anteojos , Dispositivos de Autoayuda , Agudeza Visual , Humanos , Errores de Refracción , Trastornos de la Visión
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 521-524, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29059924

RESUMEN

Magnetoencephalography (MEG) neuroimaging has been used to study subjects' responses when listening to music, but research into the effects of playing music has been limited by the lack of MEG compatible instruments that can operate in a magnetically shielded environment without creating electromagnetic interference. This paper describes the design and preliminary testing of an MEG compatible piano keyboard with 25 full size keys that employs a novel 3-state optical encoder design and electronics to provide realistic velocity-controlled volume modulation. This instrument will allow researchers to study musical performance on a finer timescale than fMRI and enable a range of MEG studies.


Asunto(s)
Música , Percepción Auditiva , Encéfalo , Magnetoencefalografía , Neuroimagen
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 2083-2086, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28268741

RESUMEN

People with low vision have limited residual vision that can be greatly enhanced through high levels of magnification. Current assistive technologies are tailored for far field or near field magnification but not both. In collaboration with L.V. Prasad Eye Institute (LVPEI), a wearable, optical-digital assistive device was developed to meet the near and far field magnification needs of students. The critical requirements, system architecture and design decisions for each module were analyzed and quantified. A proof-of-concept prototype was fabricated that can achieve magnification up to 8x and a battery life of up to 8 hours. Potential user evaluation with a Snellen chart showed identification of characters not previously discernible. Further feedback suggested that the system could be used as a general accessibility aid.


Asunto(s)
Dispositivos Ópticos , Dispositivos de Autoayuda , Baja Visión , Humanos , Estudiantes , Agudeza Visual
11.
Int J Med Robot ; 11(4): 458-75, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25475147

RESUMEN

BACKGROUND: Minimally invasive biopsies, drainages and therapies in the soft tissue organs of the thorax and abdomen are typically performed through a needle, which is inserted percutaneously to reach the target area. The conventional workflow for needle placement employs an iterative freehand technique. This article provides an overview of needle-placement systems developed to improve this method. METHODS: An overview of systems for needle placement was assembled, including those found in scientific publications and patents, as well as those that are commercially available. The systems are categorized by function and tabulated. RESULTS: Over 40 systems were identified, ranging from simple passive aids to fully actuated robots. CONCLUSIONS: The overview shows a wide variety of developed systems with growing complexity. However, given that only a few systems have reached commercial availability, it is clear that the technical community is struggling to develop solutions that are adopted clinically. Copyright © 2014 John Wiley & Sons, Ltd.


Asunto(s)
Biopsia Guiada por Imagen/instrumentación , Imagen por Resonancia Magnética Intervencional/instrumentación , Punciones/instrumentación , Radiografía Abdominal/instrumentación , Radiografía Intervencional/instrumentación , Radiografía Torácica/instrumentación , Diseño de Equipo , Humanos , Biopsia Guiada por Imagen/métodos , Agujas , Punciones/métodos , Tomografía Computarizada por Rayos X/instrumentación
12.
Artículo en Inglés | MEDLINE | ID: mdl-26737417

RESUMEN

People suffering from low vision, a condition caused by a variety of eye-related diseases and/or disorders, find their ability to read greatly improved when text is magnified between 2 and 6 times. Assistive devices currently on the market are either geared towards reading text far away (~20 ft.) or very near (~2 ft.). This is a problem especially for students suffering from low vision, as they struggle to flip their focus between the chalkboard (far-field) and their notes (near- field). A solution to this problem is of high interest to eye care facilities in the developing world - no devices currently exist that have the aforementioned capabilities at an accessible price point. Through consultation with specialists at L.V. Prasad Eye Institute in India, the authors propose, design and demonstrate a device that fills this need, directed primarily at the Indian market. The device utilizes available hardware technologies to electronically capture video ahead of the user and zoom and display the image in real-time on LCD screens mounted in front of the user's eyes. This design is integrated as a wearable system in a glasses form-factor.


Asunto(s)
Auxiliares Sensoriales , Baja Visión/fisiopatología , Anteojos , Humanos , Dispositivos de Autoayuda
13.
IEEE J Transl Eng Health Med ; 1: 4700107, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-27170859

RESUMEN

Innovation in patient care requires both clinical and technical skills, and this paper presents the methods and outcomes of a nine-year, clinical-academic collaboration to develop and evaluate new medical device technologies, while teaching mechanical engineering. Together, over the course of a single semester, seniors, graduate students, and clinicians conceive, design, build, and test proof-of-concept prototypes. Projects initiated in the course have generated intellectual property and peer-reviewed publications, stimulated further research, furthered student and clinician careers, and resulted in technology licenses and start-up ventures.

14.
J Thorac Imaging ; 26(3): 196-203, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21263356

RESUMEN

PURPOSE: To determine factors influencing the number of acquired scan series and subsequently the radiation dose and time during computed tomography (CT)-guided lung biopsies. MATERIALS AND METHODS: This Health Insurance Portability and Accountability Act-compliant, institutional review board-approved, retrospective study reviewed 50 consecutive procedures. Each procedure was separated into the following steps: trajectory planning, needle placement, needle insertion (extrapulmonary and intrapulmonary), and sampling and follow-up. The number of scan series, time, and radiation dose were calculated for each procedure and its steps. The effects of patient characteristics (age, sex, history of surgery that violated the pleura), procedure characteristics (needle-pleural angle, patient position), and lesion characteristics (size, depth, lobar location) on the number of scan series for the procedure and each step were evaluated using stepwise linear regression. The overall diagnostic accuracy, pneumothorax rate, and chest tube insertion rate were also calculated. RESULTS: The mean number of total CT scans was 21, the mean effective dose was 14 mSv, and the mean entrance skin dose was 249 mGy. On average, trajectory planning and needle insertion contributed most to the number of scan series (18.5% and 52.9%, respectively). For trajectory planning, a smaller lesion size and shallower needle-pleural angle were associated with an increased number of scans (R(2)=0.200, P=0.005). During needle insertion, smaller lesions were associated with increased scanning (R(2)=0.296, P<0.001), with both smaller and deeper lesions associated with an increased number of scans during the intrapulmonary component (R(2)=0.372, P<0.001). For the entire procedure, smaller lesions were associated with an increased number of scans (R(2)=0.12, P=0.01). CONCLUSION: Lesions that are smaller or deeper in the lung result in a higher number of CT scans, resulting in increased radiation dose and procedure time, with most of these performed during the needle insertion step.


Asunto(s)
Biopsia con Aguja/métodos , Neoplasias Pulmonares/diagnóstico , Dosis de Radiación , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
Artículo en Inglés | MEDLINE | ID: mdl-18002191

RESUMEN

This paper details the design and interface development of Robopsy, an economical, tele-operated, patient mounted, disposable needle guidance and insertion system to assist radiologists in performing minimally invasive percutaneous biopsies remotely under CT guidance. Testing with a phantom in a realistic surgical setting was conducted to ensure that the interface was intuitive and facilitated smooth integration of the device into current procedure. Ease of learning and operation is critical in order to encourage rapid adoption of this new medical robotics model.


Asunto(s)
Biopsia/instrumentación , Ergonomía/instrumentación , Sistemas Hombre-Máquina , Robótica/instrumentación , Cirugía Asistida por Computador/instrumentación , Telemedicina/instrumentación , Interfaz Usuario-Computador , Biopsia/economía , Diseño de Equipo , Análisis de Falla de Equipo , Ergonomía/economía , Ergonomía/métodos , Robótica/economía , Cirugía Asistida por Computador/economía , Telemedicina/economía , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA