Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Appl Opt ; 50(15): 2263-73, 2011 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-21614121

RESUMEN

We investigated the fundamental limits to the performance of a laser vibrometer that is mounted on a moving ground vehicle. The noise floor of a moving laser vibrometer consists of speckle noise, shot noise, and platform vibrations. We showed that speckle noise can be reduced by increasing the laser spot size and that the noise floor is dominated by shot noise at high frequencies (typically greater than a few kilohertz for our system). We built a five-channel, vehicle-mounted, 1.55 µm wavelength laser vibrometer to measure its noise floor at 10 m horizontal range while driving on dirt roads. The measured noise floor agreed with our theoretical estimates. We showed that, by subtracting the response of an accelerometer and an optical reference channel, we could reduce the excess noise (in units of micrometers per second per Hz(1/2)) from vehicle vibrations by a factor of up to 33, to obtain nearly speckle-and-shot-noise-limited performance from 0.3 to 47 kHz.

2.
Light Sci Appl ; 8: 119, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31885865

RESUMEN

Full noncontact laser ultrasound (LUS) imaging has several distinct advantages over current medical ultrasound (US) technologies: elimination of the coupling mediums (gel/water), operator-independent image quality, improved repeatability, and volumetric imaging. Current light-based ultrasound utilizing tissue-penetrating photoacoustics (PA) generally uses traditional piezoelectric transducers in contact with the imaged tissue or carries an optical fiber detector close to the imaging site. Unlike PA, the LUS design presented here minimizes the optical penetration and specifically restricts optical-to-acoustic energy transduction at the tissue surface, maximizing the generated acoustic source amplitude. With an appropriate optical design and interferometry, any exposed tissue surfaces can become viable acoustic sources and detectors. LUS operates analogously to conventional ultrasound but uses light instead of piezoelectric elements. Here, we present full noncontact LUS results, imaging targets at ~5 cm depths and at a meter-scale standoff from the target surface. Experimental results demonstrating volumetric imaging and the first LUS images on humans are presented, all at eye- and skin-safe optical exposure levels. The progression of LUS imaging from tissue-mimicking phantoms, to excised animal tissue, to humans in vivo is shown, with validation from conventional ultrasound images. The LUS system design insights and results presented here inspire further LUS development and are a significant step toward the clinical implementation of LUS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA