Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38970460

RESUMEN

PURPOSE: T2-weighted DANTE-SPACE (Delay Alternating with Nutation for Tailored Excitation - Sampling Perfection with Application optimized Contrasts using different flip angle Evolution) sequences facilitate non-invasive intracranial vessel wall imaging at 7T through simultaneous suppression of blood and CSF. However, the achieved vessel wall delineation depends closely on the selected sequence parameters, and little information is available about the performance of the sequence using more widely available 3T MRI. Therefore, in this paper a comprehensive DANTE-SPACE simulation framework is used for the optimization and quantitative comparison of T2-weighted DANTE-SPACE at both 7T and 3T. METHODS: Simulations are used to propose optimized sequence parameters at both 3T and 7T. At 7T, an additional protocol which uses a parallel transmission (pTx) shim during the DANTE preparation for improved suppression of inflowing blood is also proposed. Data at both field strengths using optimized and literature protocols are acquired and quantitatively compared in six healthy volunteers. RESULTS: At 7T, more vessel wall signal can be retained while still achieving sufficient CSF suppression by using fewer DANTE pulses than described in previous implementations. The use of a pTx shim during DANTE at 7T provides a modest further improvement to the inner vessel wall delineation. At 3T, aggressive DANTE preparation is required to achieve CSF suppression, resulting in reduced vessel wall signal. As a result, the achievable vessel wall definition at 3T is around half that of 7T. CONCLUSION: Simulation-based optimization of DANTE parameters facilitates improved T2-weighted DANTE-SPACE contrasts at 7T. The improved vessel definition of T2-weighted DANTE-SPACE at 7T makes DANTE preparation more suitable for T2-weighted VWI at 7T than at 3T.

2.
Magn Reson Med ; 92(1): 332-345, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38469983

RESUMEN

PURPOSE: The delay alternating with nutation for tailored excitation (DANTE)-sampling perfection with application-optimized contrasts (SPACE) sequence facilitates 3D intracranial vessel wall imaging with simultaneous suppression of blood and CSF. However, the achieved image contrast depends closely on the selected sequence parameters, and the clinical use of the sequence is limited in vivo by observed signal variations in the vessel wall, CSF, and blood. This paper introduces a comprehensive DANTE-SPACE simulation framework, with the aim of providing a better understanding of the underlying contrast mechanisms and facilitating improved parameter selection and contrast optimization. METHODS: An extended phase graph formalism was developed for efficient spin ensemble simulation of the DANTE-SPACE sequence. Physiological processes such as pulsatile flow velocity variation, varying flow directions, intravoxel velocity variation, diffusion, and B 1 + $$ {\mathrm{B}}_1^{+} $$ effects were included in the framework to represent the mechanisms behind the achieved signal levels accurately. RESULTS: Intravoxel velocity variation improved temporal stability and robustness against small velocity changes. Time-varying pulsatile velocity variation affected CSF simulations, introducing periods of near-zero velocity and partial rephasing. Inclusion of diffusion effects was found to substantially reduce the CSF signal. Blood flow trajectory variations had minor effects, but B 1 + $$ {\mathrm{B}}_1^{+} $$ differences along the trajectory reduced DANTE efficiency in low- B 1 + $$ {\mathrm{B}}_1^{+} $$ areas. Introducing low-velocity pulsatility of both CSF and vessel wall helped explain the in vivo observed signal heterogeneity in both tissue types. CONCLUSION: The presented simulation framework facilitates a more comprehensive optimization of DANTE-SPACE sequence parameters. Furthermore, the simulation framework helps to explain observed contrasts in acquired data.


Asunto(s)
Algoritmos , Encéfalo , Simulación por Computador , Imagenología Tridimensional , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Imagenología Tridimensional/métodos , Velocidad del Flujo Sanguíneo/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Flujo Pulsátil/fisiología , Circulación Cerebrovascular/fisiología , Imagen por Resonancia Magnética/métodos
3.
Magn Reson Med ; 91(1): 190-204, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37794847

RESUMEN

PURPOSE: Neurovascular MRI suffers from a rapid drop in B1 + into the neck when using transmit head coils at 7 T. One solution to improving B1 + magnitude in the major feeding arteries in the neck is to use custom RF shims on parallel-transmit head coils. However, calculating such shims requires robust multichannel B1 + maps in both the head and the neck, which is challenging due to low RF penetration into the neck, limited dynamic range of multichannel B1 + mapping techniques, and B0 sensitivity. We therefore sought a robust, large-dynamic-range, parallel-transmit field mapping protocol and tested whether RF shimming can improve carotid artery B1 + magnitude in practice. METHODS: A pipeline is presented that combines B1 + mapping data acquired using circularly polarized (CP) and CP2-mode RF shims at multiple voltages. The pipeline was evaluated by comparing the predicted and measured B1 + for multiple random transmit shims, and by assessing the ability of RF shimming to increase B1 + in the carotid arteries. RESULTS: The proposed method achieved good agreement between predicted and measured B1 + in both the head and the neck. The B1 + magnitude in the carotid arteries can be increased by 43% using tailored RF shims or by 37% using universal RF shims, while also improving the RF homogeneity compared with CP mode. CONCLUSION: B1 + in the neck can be increased using RF shims calculated from multichannel B1 + maps in both the head and the neck. This can be achieved using universal phase-only RF shims, facilitating easy implementation in existing sequences.


Asunto(s)
Cabeza , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Cabeza/diagnóstico por imagen , Cuello/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Ondas de Radio , Fantasmas de Imagen
4.
Magn Reson Med ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38934380

RESUMEN

PURPOSE: To acquire accurate volumetric multi-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit (pTx) applications at 7 T. THEORY AND METHODS: We evaluate the combination of three recently proposed techniques. The acquisition of multi-channel transmit array B 1 + $$ {\mathrm{B}}_1^{+} $$ maps is accelerated using transmit low rank (TxLR) with absolute B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping (Sandwich) acquired in a B 1 + $$ {\mathrm{B}}_1^{+} $$ time-interleaved acquisition of modes (B1TIAMO) fashion. Simulations using synthetic body images derived from Sim4Life were used to test the achievable acceleration for small scan matrices of 24 × 24. Next, we evaluated the method by retrospectively undersampling a fully sampled B 1 + $$ {\mathrm{B}}_1^{+} $$ library of nine subjects in the brain. Finally, Cartesian undersampled phantom and in vivo images were acquired in both the brain of three subjects (8Tx/32 receive [Rx]) and the heart of another three subjects (8Tx/8Rx) at 7 T. RESULTS: Simulation and in vivo results show that volumetric multi-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps can be acquired using acceleration factors of 4 in the body, reducing the acquisition time to within 23 heartbeats, which was previously not possible. In silico heart simulations demonstrated a RMS error to the fully sampled native resolution ground truth of 4.2° when combined in first-order circularly polarized mode (mean flip angle 66°) at an acceleration factor of 4. The 14 s 3D B 1 + $$ {\mathrm{B}}_1^{+} $$ maps acquired in the brain have a RMS error of 1.9° to the fully sampled (mean flip angle 86°). CONCLUSION: The proposed method is demonstrated as a fast pTx calibration technique in the brain and a promising method for pTx calibration in the body.

5.
Transfusion ; 64(3): 449-453, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38299721

RESUMEN

BACKGROUND: Administering platelets through a rapid infuser is proven to be safe. However, the clinical significance of infusing ABO-incompatible platelets with red blood cells (RBCs) in a rapid infuser remains unclear. There is a theoretical risk that isoagglutinin in the plasma of a platelet unit can interact with RBCs and induce hemolysis. MATERIALS AND METHODS: Seven in vitro studies were performed including five cases (type A RBCs and type O platelets) and two controls (type A RBCs and platelets). Anti-A titers were measured in platelet units. An RBC unit and a platelet unit were mixed in the rapid infuser reservoir and incubated for 30 min. The primary outcome was the presence of hemolysis based on the following parameters: free hemoglobin concentration, hemolysis check, direct antiglobulin test (DAT), and direct agglutination. RESULTS: The post-mix DAT was positive for IgG in all test samples (5/5), and weakly positive for complement in 3/5. The changes in free Hb in test cases between measured and calculated post-mix spanned -2.2 to +3.4 mg/dL. Post-mix hemolysis check was negative in 3/5 and slightly positive in 2/5 cases, with no significant differences compared to the control case. Anti-A titers ranged from 16 to 512 and were not associated with hemolysis. All samples were negative for direct agglutination. CONCLUSION: Our study suggested that mixing ABO-incompatible platelets with RBCs in a rapid infuser does not induce in vitro hemolysis. These findings support the use of rapid infusers regardless of platelet compatibility in support of hemostatic resuscitation.


Asunto(s)
Sistema del Grupo Sanguíneo ABO , Hemólisis , Humanos , Transfusión de Plaquetas/efectos adversos , Incompatibilidad de Grupos Sanguíneos , Plaquetas , Anticuerpos
6.
Magn Reson Med ; 89(6): 2376-2390, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36656151

RESUMEN

PURPOSE: To assess the accuracy of morphing an established reference electromagnetic head model to a subject-specific morphometry for the estimation of specific absorption rate (SAR) in 7T parallel-transmit (pTx) MRI. METHODS: Synthetic T1 -weighted MR images were created from three high-resolution open-source electromagnetic head voxel models. The accuracy of morphing a "reference" (multimodal image-based detailed anatomical [MIDA]) electromagnetic model into a different subject's native space (Duke and Ella) was compared. Both linear and nonlinear registration methods were evaluated. Maximum 10-g averaged SAR was estimated for circularly polarized mode and for 5000 random RF shim sets in an eight-channel transmit head coil, and comparison made between the morphed MIDA electromagnetic models and the native Duke and Ella electromagnetic models, respectively. RESULTS: The averaged error in maximum 10-g averaged SAR estimation across pTx MRI shim sets between the MIDA and the Duke target model was reduced from 17.5% with only rigid-body registration, to 11.8% when affine linear registration was used, and further reduced to 10.7% when nonlinear registration was used. The corresponding figures for the Ella model were 16.7%, 11.2%, and 10.1%. CONCLUSION: We found that morphometry accounts for up to half of the subject-specific differences in pTx SAR. Both linear and nonlinear morphing of an electromagnetic model into a target subject improved SAR agreement by better matching head size, morphometry, and position. However, differences remained, likely arising from details in tissue composition estimation. Thus, the uncertainty of the head morphometry and tissue composition may need to be considered separately to achieve personalized SAR estimation.


Asunto(s)
Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
7.
Magn Reson Med ; 89(3): 964-976, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36336893

RESUMEN

PURPOSE: To shorten the acquisition time of magnetization-prepared absolute transmit field (B1 + ) mapping known as presaturation TurboFLASH, or satTFL, to enable single breath-hold whole-heart 3D B1 + mapping. METHODS: SatTFL is modified to remove the delay between the reference and prepared images (typically 5 T1 ), with matching transmit configurations for excitation and preparation RF pulses. The new method, called Sandwich, is evaluated as a 3D sequence, measuring whole-brain and gated whole-heart B1 + maps in a single breath-hold. We evaluate the sensitivity to B1 + and T1 using numerical Bloch, extended phase graph, and Monte Carlo simulations. Phantom and in vivo images were acquired in both the brain and heart using an 8-channel transmit 7 Tesla MRI system to support the simulations. A segmented satTFL with a short readout train was used as a reference. RESULTS: The method significantly reduces acquisition times of 3D measurements from 360 s to 20 s, in the brain, while simultaneously reducing bias in the measured B1 + due to T1 and magnetization history. The mean coefficient of variation was reduced by 81% for T1 s of 0.5-3 s compared to conventional satTFL. In vivo, the reproducibility coefficient for flip angles in the range 0-130° was 4.5° for satTFL and 4.7° for our scheme, significantly smaller than for a short TR satTFL sequence, which was 12°. The 3D sequence measured B1 + maps of the whole thorax in 26 heartbeats. CONCLUSION: Our adaptations enable faster B1 + mapping, with minimal T1 sensitivity and lower sensitivity to magnetization history, enabling single breath-hold whole-heart absolute B1 + mapping.


Asunto(s)
Encéfalo , Corazón , Reproducibilidad de los Resultados , Corazón/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Tórax , Mapeo Encefálico/métodos
8.
Magn Reson Med ; 90(6): 2643-2652, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37529979

RESUMEN

PURPOSE: To develop a temperature-controlled cooling system to facilitate accurate quantitative post-mortem MRI and enable scanning of unfixed tissue. METHODS: A water cooling system was built and integrated with a 7T scanner to minimize temperature drift during MRI scans. The system was optimized for operational convenience and rapid deployment to ensure efficient workflow, which is critical for scanning unfixed post-mortem samples. The performance of the system was evaluated using a 7-h diffusion MRI protocol at 7T with a porcine tissue sample. Quantitative T1 , T2 , and ADC maps were interspersed with the diffusion scans at seven different time points to investigate the temperature dependence of MRI tissue parameters. The impact of temperature changes on biophysical model fitting of diffusion MRI data was investigated using simulation. RESULTS: Tissue T1 , T2 , and ADC values remained stable throughout the diffusion MRI scan using the developed cooling system, but varied substantially using a conventional scan setup without temperature control. The cooling system enabled accurate estimation of biophysical model parameters by stabilizing the tissue temperature throughout the diffusion scan, while the conventional setup showed evidence of significantly biased estimation. CONCLUSION: A temperature-controlled cooling system was developed to tackle the challenge of heating in post-mortem imaging, which shows potential to improve the accuracy and reliability of quantitative post-mortem imaging and enables long scans of unfixed tissue.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Porcinos , Animales , Temperatura , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Autopsia
9.
BMC Cancer ; 23(1): 99, 2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36709278

RESUMEN

BACKGROUND: Both Red Blood Cell (RBC) transfusion and anemia are thought to negatively impact cancer survival. These effects have been reported with mixed findings in cancer of the esophagus. The potential impact of the application of restrictive transfusion strategies on this patient population has not been defined. MATERIALS AND METHODS: We conducted a retrospective study of esophagectomies and studied cases based on whether they were anemic or were transfused peri-operatively. Clinical characteristics and known clinicopathologic prognosticators were compared between these groups. Survival was compared by Cox proportional hazard modeling. Post-operative transfusions were assessed for compliance with restrictive transfusion thresholds. RESULTS: Three-hundred ninety-nine esophagectomy cases were reviewed and after exclusions 348 cases were analyzed. The median length of follow-up was 33 months (range 1-152 months). Sixty-four percent of patients were anemic pre-operatively and 22% were transfused. Transfusion and anemia were closely related to each other. Microcytic anemia was uncommon but was evaluated and treated in only 50% of cases. Most anemic patients had normocytic RBC parameters. Transfusion but not anemia was associated with a protracted/prolonged post-operative stay. Transfusion and anemia were both associated with reduced survival however only anemia was associated with decreased survival in multi-variable modeling. Sixty-eight percent of patients were transfused post-operatively and 11% were compliant with the restrictive threshold of 7 g/dL. CONCLUSIONS: Pre-operative anemia and transfusion are closely associated, however only anemia was found to compromise survival in our esophageal cancer cohort, supporting the need for more aggressive evaluation and treatment of anemia. Adherence to restrictive transfusion guidelines offers an opportunity to reduce transfusion rates which may also improve short-term outcomes.


Asunto(s)
Anemia , Neoplasias , Humanos , Estudios Retrospectivos , Anemia/etiología , Anemia/terapia , Transfusión Sanguínea , Neoplasias/complicaciones , Esófago
10.
J Magn Reson Imaging ; 57(3): 690-705, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36326548

RESUMEN

Complex engineered systems are often equipped with suites of sensors and ancillary devices that monitor their performance and maintenance needs. MRI scanners are no different in this regard. Some of the ancillary devices available to support MRI equipment, the ones of particular interest here, have the distinction of actually participating in the image acquisition process itself. Most commonly, such devices are used to monitor physiological motion or variations in the scanner's imaging fields, allowing the imaging and/or reconstruction process to adapt as imaging conditions change. "Classic" examples include electrocardiography (ECG) leads and respiratory bellows to monitor cardiac and respiratory motion, which have been standard equipment in scan rooms since the early days of MRI. Since then, many additional sensors and devices have been proposed to support MRI acquisitions. The main physical properties that they measure may be primarily "mechanical" (eg acceleration, speed, and torque), "acoustic" (sound and ultrasound), "optical" (light and infrared), or "electromagnetic" in nature. A review of these ancillary devices, as currently available in clinical and research settings, is presented here. In our opinion, these devices are not in competition with each other: as long as they provide useful and unique information, do not interfere with each other and are not prohibitively cumbersome to use, they might find their proper place in future suites of sensors. In time, MRI acquisitions will likely include a plurality of complementary signals. A little like the microbiome that provides genetic diversity to organisms, these devices can provide signal diversity to MRI acquisitions and enrich measurements. Machine-learning (ML) algorithms are well suited at combining diverse input signals toward coherent outputs, and they could make use of all such information toward improved MRI capabilities. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Corazón/fisiología , Electrocardiografía , Movimiento (Física) , Movimiento/fisiología
11.
Transfusion ; 63(10): 1833-1840, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37644845

RESUMEN

BACKGROUND: Large language models (LLMs) excel at answering knowledge-based questions. Many aspects of blood banking and transfusion medicine involve no direct patient care and require only knowledge and judgment. We hypothesized that public LLMs could perform such tasks with accuracy and precision. STUDY DESIGN AND METHODS: We presented three sets of tasks to three publicly-available LLMs (Bard, GPT-3.5, and GPT-4). The first was to review short case presentations and then decide if a red blood cell transfusion was indicated. The second task was to answer a set of consultation questions common in clinical transfusion practice. The third task was to take a multiple-choice test experimentally validated to assess internal medicine postgraduate knowledge of transfusion practice (the BEST-TEST). RESULTS: In the first task, the area under the receiver operating characteristic curve for correct transfusion decisions was 0.65, 0.90, and 0.92, respectively for Bard, GPT-3.5 and GPT-4. All three models had a modest rate of acceptable responses to the consultation questions. Average scores on the BEST-TEST were 55%, 40%, and 87%, respectively. CONCLUSION: When presented with transfusion medicine tasks in natural language, publicly available LLMs demonstrated a range of ability, but GPT-4 consistently scored very well in all tasks. Research is needed to assess the utility of LLMs in transfusion medicine practice. Transfusion Medicine physicians should consider their role alongside such technologies, and how they might be used for the benefit and safety of patients.


Asunto(s)
Médicos , Medicina Transfusional , Humanos , Inteligencia Artificial , Transfusión Sanguínea , Transfusión de Eritrocitos
12.
Transfusion ; 63(1): 83-91, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36377099

RESUMEN

BACKGROUND: The purpose of this study was to survey liver transplant centers in the United States to assess baseline practices in blood utilization and identify opportunities for standardization to optimize blood use in these complex cases. STUDY DESIGN AND METHODS: Two surveys, one for transfusion medicine physicians and the other for anesthesiologists, were distributed to high-volume liver transplant centers. RESULTS: The response rate was 52% for both surveys. The majority of respondents (90%) indicated they issue a standardized number of blood products to start surgeries. The most common number of products issued before the start of cases were 10 red blood cells (RBC) and 10 plasma units with no platelets or cryoprecipitate. On average, fewer RBC (7.5) and plasma (7) units were transfused than issued. Decisions to transfuse RhD+ RBCs to RhD- patients and use antigen untested units in alloimmunized patients were mainly handled on a case-by-case basis. Many centers reported utilizing viscoelastic testing (97%) and cell salvage (97%). Most centers reported standardized, laboratory-based intraoperative transfusion goals for RBCs (65%) and fibrinogen replacement (52%) but lacked a standardized approach for plasma (55%) and platelets (58%). DISCUSSION: More blood products are issued during surgery than are transfused. Responses from anesthesiology providers suggest a broad consensus on practice. Almost all respondents use viscoelastic testing in the management of intraoperative coagulopathy, either alone or in combination with classical coagulation tests. The majority of programs do not transfuse clotting factor concentrates, including fibrinogen concentrate, prothrombin complex concentrates, and recombinant activated FVII, and do not use antifibrinolytics prophylactically.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Trasplante de Hígado , Humanos , Transfusión Sanguínea , Fibrinógeno/uso terapéutico , Pruebas de Coagulación Sanguínea
13.
Transfusion ; 63(8): 1590-1600, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37403547

RESUMEN

BACKGROUND: The Association for the Advancement of Blood and Biotherapies Clinical Transfusion Medicine Committee (CTMC) composes a summary of new and important advances in transfusion medicine (TM) on an annual basis. Since 2018, this has been assembled into a manuscript and published in Transfusion. STUDY DESIGN AND METHODS: CTMC members selected original manuscripts relevant to TM that were published electronically and/or in print during calendar year 2022. Papers were selected based on perceived importance and/or originality. References for selected papers were made available to CTMC members to provide feedback. Members were also encouraged to identify papers that may have been omitted initially. They then worked in groups of two to three to write a summary for each new publication within their broader topic. Each topic summary was then reviewed and edited by two separate committee members. The final manuscript was assembled by the first and senior authors. While this review is extensive, it is not a systematic review and some publications considered important by readers may have been excluded. RESULTS: For calendar year 2022, summaries of key publications were assembled for the following broader topics within TM: blood component therapy; infectious diseases, blood donor testing, and collections; patient blood management; immunohematology and genomics; hemostasis; hemoglobinopathies; apheresis and cell therapy; pediatrics; and health care disparities, diversity, equity, and inclusion. DISCUSSION: This Committee Report reviews and summarizes important publications and advances in TM published during calendar year 2022, and maybe a useful educational tool.

14.
JAMA ; 330(19): 1892-1902, 2023 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-37824153

RESUMEN

Importance: Red blood cell transfusion is a common medical intervention with benefits and harms. Objective: To provide recommendations for use of red blood cell transfusion in adults and children. Evidence Review: Standards for trustworthy guidelines were followed, including using Grading of Recommendations Assessment, Development and Evaluation methods, managing conflicts of interest, and making values and preferences explicit. Evidence from systematic reviews of randomized controlled trials was reviewed. Findings: For adults, 45 randomized controlled trials with 20 599 participants compared restrictive hemoglobin-based transfusion thresholds, typically 7 to 8 g/dL, with liberal transfusion thresholds of 9 to 10 g/dL. For pediatric patients, 7 randomized controlled trials with 2730 participants compared a variety of restrictive and liberal transfusion thresholds. For most patient populations, results provided moderate quality evidence that restrictive transfusion thresholds did not adversely affect patient-important outcomes. Recommendation 1: for hospitalized adult patients who are hemodynamically stable, the international panel recommends a restrictive transfusion strategy considering transfusion when the hemoglobin concentration is less than 7 g/dL (strong recommendation, moderate certainty evidence). In accordance with the restrictive strategy threshold used in most trials, clinicians may choose a threshold of 7.5 g/dL for patients undergoing cardiac surgery and 8 g/dL for those undergoing orthopedic surgery or those with preexisting cardiovascular disease. Recommendation 2: for hospitalized adult patients with hematologic and oncologic disorders, the panel suggests a restrictive transfusion strategy considering transfusion when the hemoglobin concentration is less than 7 g/dL (conditional recommendations, low certainty evidence). Recommendation 3: for critically ill children and those at risk of critical illness who are hemodynamically stable and without a hemoglobinopathy, cyanotic cardiac condition, or severe hypoxemia, the international panel recommends a restrictive transfusion strategy considering transfusion when the hemoglobin concentration is less than 7 g/dL (strong recommendation, moderate certainty evidence). Recommendation 4: for hemodynamically stable children with congenital heart disease, the international panel suggests a transfusion threshold that is based on the cardiac abnormality and stage of surgical repair: 7 g/dL (biventricular repair), 9 g/dL (single-ventricle palliation), or 7 to 9 g/dL (uncorrected congenital heart disease) (conditional recommendation, low certainty evidence). Conclusions and Relevance: It is good practice to consider overall clinical context and alternative therapies to transfusion when making transfusion decisions about an individual patient.


Asunto(s)
Transfusión de Eritrocitos , Hemoglobinas , Adulto , Niño , Humanos , Enfermedades Cardiovasculares , Toma de Decisiones , Transfusión de Eritrocitos/normas , Cardiopatías Congénitas , Hemoglobinas/análisis , Ensayos Clínicos Controlados Aleatorios como Asunto
15.
Liver Transpl ; 28(10): 1651-1663, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35253365

RESUMEN

Patients with acute and chronic liver disease present with a wide range of disease states and severity that may require liver transplantation (LT). Physiologic alterations occur that are dynamic throughout all phases of perioperative care, creating complex management scenarios that necessitate multidisciplinary clinical care. Specifically, alterations in hemostasis in liver disease can be pronounced and evolve with disease progression over time. Recent studies and society guidance address this emerging paradigm and offer recommendations to assist with hemostatic management in patients with liver disease. However, patients undergoing LT are unique and diverse, often with unstable disease that requires specialized approaches. Our aim is to provide a focused review of hemostatic management of the LT patient, distinguish unique aspects of the three main phases of care (before LT, perioperative, and after LT), and identify knowledge gaps and critical areas of future research.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Hemostáticos , Hepatopatías , Trasplante de Hígado , Trastornos de la Coagulación Sanguínea/diagnóstico , Trastornos de la Coagulación Sanguínea/etiología , Trastornos de la Coagulación Sanguínea/terapia , Hemostasis/fisiología , Humanos , Hepatopatías/complicaciones , Hepatopatías/cirugía , Trasplante de Hígado/efectos adversos
16.
Magn Reson Med ; 88(2): 880-889, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35344622

RESUMEN

PURPOSE: 3D time-of-flight MRA can accurately visualize the intracranial vasculature but is limited by long acquisition times. Compressed sensing reconstruction can be used to substantially accelerate acquisitions. The quality of those reconstructions depends on the undersampling patterns used. In this work, we optimize sets of undersampling parameters for various acceleration factors of Cartesian 3D time-of-flight MRA. METHODS: Fully sampled datasets, acquired at 7 Tesla, were retrospectively undersampled using variable-density Poisson disk sampling with various autocalibration region sizes, polynomial orders, and acceleration factors. The accuracy of reconstructions from the different undersampled datasets was assessed using the vessel-masked structural similarity index. Identified optimal undersampling parameters were then evaluated in additional prospectively undersampled datasets. Compressed sensing reconstruction parameters were chosen based on a preliminary reconstruction parameter optimization. RESULTS: For all acceleration factors, using a fully sampled calibration area of 12 × 12 k-space lines and a polynomial order of 2 resulted in the highest image quality. The importance of parameter optimization of the sampling was found to increase for higher acceleration factors. The results were consistent across resolutions and regions of interest with vessels of varying sizes and tortuosity. The number of visible small vessels increased by 7.0% and 14.2% when compared to standard parameters for acceleration factors of 7.2 and 15, respectively. CONCLUSION: The image quality of compressed sensing time-of-flight MRA can be improved by appropriate choice of undersampling parameters. The optimized sets of parameters are independent of the acceleration factor and enable a larger number of vessels to be visualized.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Aceleración , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Estudios Retrospectivos
17.
Transfusion ; 62(7): 1435-1445, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35713186

RESUMEN

BACKGROUND: Each year the AABB Clinical Transfusion Medicine Committee (CTMC) procures a synopsis highlighting new, important, and clinically relevant studies in the field of transfusion medicine (TM). This has been made available as a publication in Transfusion since 2018. METHODS: CTMC members reviewed and identified original manuscripts covering TM-related topics published electronically (ahead-of-print) or in print from December 2020 to December 2021. Selection of publications was discussed at committee meetings and chosen based on perceived relevance and originality. Next, committee members worked in pairs to create a synopsis of each topic, which was then reviewed by additional committee members. The first and senior authors assembled the final manuscript. Although this synopsis is extensive, it is not exhaustive, and some articles may have been excluded or missed. RESULTS: The following topics are included: blood products; convalescent plasma; donor collections and testing; hemoglobinopathies; immunohematology and genomics; hemostasis; patient blood management; pediatrics; therapeutic apheresis; and cell therapy. CONCLUSIONS: This synopsis highlights and summarizes recent key developments in TM and may be useful for educational purposes.


Asunto(s)
Eliminación de Componentes Sanguíneos , Medicina Transfusional , Transfusión Sanguínea , Niño , Humanos
18.
Transfusion ; 62(8): 1559-1570, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35808950

RESUMEN

BACKGROUND: At the start of the coronavirus disease 2019 (COVID-19) pandemic, widespread blood shortages were anticipated. We sought to determine how hospital blood supply and blood utilization were affected by the first wave of COVID-19. STUDY DESIGN AND METHODS: Weekly red blood cell (RBC) and platelet (PLT) inventory, transfusion, and outdate data were collected from 13 institutions in the United States, Brazil, Canada, and Denmark from March 1st to December 31st of 2020 and 2019. Data from the sites were aligned based on each site's local first peak of COVID-19 cases, and data from 2020 (pandemic year) were compared with data from the corresponding period in 2019 (pre-pandemic baseline). RESULTS: RBC inventories were 3% lower in 2020 than in 2019 (680 vs. 704, p < .001) and 5% fewer RBCs were transfused per week compared to 2019 (477 vs. 501, p < .001). However, during the first COVID-19 peak, RBC and PLT inventories were higher than normal, as reflected by deviation from par, days on hand, and percent outdated. At this time, 16% fewer inpatient beds were occupied, and 43% fewer surgeries were performed compared to 2019 (p < .001). In contrast to 2019 when there was no correlation, there was, in 2020, significant negative correlations between RBC and PLT days on hand and both percentage occupancy of inpatient beds and percentage of surgeries performed. CONCLUSION: During the COVID-19 pandemic in 2020, RBC and PLT inventories remained adequate. During the first wave of cases, significant decreases in patient care activities were associated with excess RBC and PLT supplies and increased product outdating.


Asunto(s)
COVID-19 , Pandemias , COVID-19/epidemiología , Transfusión de Eritrocitos , Eritrocitos , Hospitales , Humanos , Estados Unidos
19.
Medicina (Kaunas) ; 59(1)2022 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-36676669

RESUMEN

Cardiothoracic surgical critical care medicine (CT-CCM) is a medical discipline centered on the perioperative care of diverse groups of patients. With an aging demographic and an increase in burden of chronic diseases the utilization of cardiothoracic surgical critical care units is likely to escalate in the coming decades. Given these projections, it is important to assess the state of cardiothoracic surgical intensive care, to develop goals and objectives for the future, and to identify knowledge gaps in need of scientific inquiry. This two-part review concentrates on CT-CCM as its own subspeciality of critical care and cardiothoracic surgery and provides aspirational goals for its practitioners and scientists. In part one, a list of guiding principles and a call-to-action agenda geared towards growth and promotion of CT-CCM are offered. In part two, an evaluation of selected scientific data is performed, identifying gaps in CT-CCM knowledge, and recommending direction to future scientific endeavors.


Asunto(s)
Anestesiología , Procedimientos Quirúrgicos Cardíacos , Humanos , Cuidados Críticos , Unidades de Cuidados Intensivos , Atención Perioperativa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA