1.
Radiology ; 305(1): 107-115, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35670712

RESUMEN

Background Accurate CT attenuation and diagnostic quality of virtual noncontrast (VNC) images acquired with photon-counting detector (PCD) CT are needed to replace true noncontrast (TNC) scans. Purpose To assess the attenuation errors and image quality of VNC images from abdominal PCD CT compared with TNC images. Materials and Methods In this retrospective study, consecutive adult patients who underwent a triphasic examination with PCD CT from July 2021 to October 2021 were included. VNC images were reconstructed from arterial and portal venous phase CT. The absolute attenuation error of VNC compared with TNC images was measured in multiple structures by two readers. Then, two readers blinded to image reconstruction assessed the overall image quality, image noise, noise texture, and delineation of small structures using five-point discrete visual scales (5 = excellent, 1 = nondiagnostic). Overall image quality greater than or equal to 3 was deemed diagnostic. In a phantom, noise texture, spatial resolution, and detectability index were assessed. A detectability index greater than or equal to 5 indicated high diagnostic accuracy. Interreader agreement was evaluated using the Krippendorff α coefficient. The paired t test and Friedman test were applied to compare objective and subjective results. Results Overall, 100 patients (mean age, 72 years ± 10 [SD]; 81 men) were included. In patients, VNC image attenuation values were consistent between readers (α = .60), with errors less than 5 HU in 76% and less than 10 HU in 95% of measurements. There was no evidence of a difference in error of VNC images from arterial or portal venous phase CT (3.3 HU vs 3.5 HU, P = .16). Subjective image quality was rated lower in VNC images for all categories (all, P < .001). Diagnostic quality of VNC images was reached in 99% and 100% of patients for readers 1 and 2, respectively. In the phantom, VNC images exhibited 33% higher noise, blotchier noise texture, similar spatial resolution, and inferior but overall good image quality (detectability index >20) compared with TNC images. Conclusion Abdominal virtual noncontrast images from the arterial and portal venous phase of photon-counting detector CT yielded accurate CT attenuation and good image quality compared with true noncontrast images. © RSNA, 2022 Online supplemental material is available for this article See also the editorial by Sosna in this issue.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Abdomen/diagnóstico por imagen , Adulto , Anciano , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
2.
Radiology ; 303(2): 339-348, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35103540

RESUMEN

Background An iterative reconstruction (IR) algorithm was introduced for clinical photon-counting detector (PCD) CT. Purpose To investigate the image quality and the optimal strength level of a quantum IR algorithm (QIR; Siemens Healthcare) for virtual monoenergetic images and polychromatic images (T3D) in a phantom and in patients undergoing portal venous abdominal PCD CT. Materials and Methods In this retrospective study, noise power spectrum (NPS) was measured in a water-filled phantom. Consecutive oncologic patients who underwent portal venous abdominal PCD CT between March and April 2021 were included. Virtual monoenergetic images at 60 keV and T3D were reconstructed without QIR (QIR-off; reference standard) and with QIR at four levels (QIR 1-4; index tests). Global noise index, contrast-to-noise ratio (CNR), and voxel-wise CT attenuation differences were measured. Noise and texture, artifacts, diagnostic confidence, and overall quality were assessed qualitatively. Conspicuity of hypodense liver lesions was rated by four readers. Parametric (analyses of variance, paired t tests) and nonparametric tests (Friedman, post hoc Wilcoxon signed-rank tests) were used to compare quantitative and qualitative image quality among reconstructions. Results In the phantom, NPS showed unchanged noise texture across reconstructions with maximum spatial frequency differences of 0.01 per millimeter. Fifty patients (mean age, 59 years ± 16 [standard deviation]; 31 women) were included. Global noise index was reduced from QIR-off to QIR-4 by 45% for 60 keV and by 44% for T3D (both, P < .001). CNR of the liver improved from QIR-off to QIR-4 by 74% for 60 keV and by 69% for T3D (both, P < .001). No evidence of difference was found in mean attenuation of fat and liver (P = .79-.84) and on a voxel-wise basis among reconstructions. Qualitatively, QIR-4 outperformed all reconstructions in every category for 60 keV and T3D (P value range, <.001 to .01). All four readers rated QIR-4 superior to other strengths for lesion conspicuity (P value range, <.001 to .04). Conclusion In portal venous abdominal photon-counting detector CT, an iterative reconstruction algorithm (QIR; Siemens Healthcare) at high strength levels improved image quality by reducing noise and improving contrast-to-noise ratio and lesion conspicuity without compromising image texture or CT attenuation values. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sinitsyn in this issue.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos
3.
Eur Radiol ; 32(6): 3903-3911, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35020010

RESUMEN

OBJECTIVES: To compare the accuracy of lesion detection of trauma-related injuries using combined "all-in-one" fused (AIO) and conventionally reconstructed images (CR) in acute trauma CT. METHODS: In this retrospective study, trauma CT of 66 patients (median age 47 years, range 18-96 years; 20 female (30.3%)) were read using AIO and CR. Images were independently reviewed by 4 blinded radiologists (two residents and two consultants) for trauma-related injuries in 22 regions. Sub-analyses were performed to analyze the influence of experience (residents vs. consultants) and body region (chest, abdomen, skeletal structures) on lesion detection. Paired t-test was used to compare the accuracy of lesion detection. The effect size was calculated (Cohen's d). Linear mixed-effects model with patients as the fixed effect and random forest models were used to investigate the effect of experience, reconstruction/image processing, and body region on lesion detection. RESULTS: Reading time of residents was significantly faster using AIO (AIO: 266 ± 72 s, CR: 318 ± 113 s; p < 0.001; d = 0.46) while no significant difference was observed in the accuracy of lesion detection (AIO: 93.5 ± 6.0%, CR: 94.6 ± 6.0% p = 0.092; d = - 0.21). Reading time of consultants showed no significant difference (AIO: 283 ± 82 s, CR: 274 ± 95 s; p = 0.067; d = 0.16). Accuracy was significantly higher using CR; however, the difference and effect size were very small (AIO 95.1 ± 4.9%, CR: 97.3 ± 3.7%, p = 0.002; d = - 0.39). The linear mixed-effects model showed only minor effect of image processing/reconstruction for lesion detection. CONCLUSIONS: Residents at the emergency department might benefit from faster reading time without sacrificing lesion detection rate using AIO for trauma CT. KEY POINTS: • Image fusion techniques decrease the reading time of acute trauma CT without sacrificing diagnostic accuracy.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X , Abdomen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Tórax , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
4.
AJR Am J Roentgenol ; 218(5): 822-829, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34877869

RESUMEN

BACKGROUND. Epicardial adipose tissue (EAT) attenuation is a vascular inflammation marker predictive of adverse cardiac events. The fat attenuation index (FAI) assesses fat attenuation for predefined coronary segments. Photon-counting detector (PCD) CT uses routine virtual monoenergetic image (VMI) reconstructions. VMI energy level may affect EAT attenuation and FAI measurements. OBJECTIVE. The purpose of this article was to assess EAT attenuation and FAI measurements at different monoenergetic energy levels in patients undergoing coronary CTA using a first-generation whole-body dual-source PCD CT scanner. METHODS. An anthropomorphic phantom at two sizes with a fat insert was imaged on a first-generation dual-source PCD CT scanner and, as a reference, on a conventional energy-integrating detector (EID) CT scanner at 120 kV. Thirty patients (11 women, 19 men; mean age, 48 ± 10 years; Agatston score < 60) who underwent an ECG-gated unenhanced calcium-scoring scan and contrast-enhanced coronary CTA by PCD CT were retrospectively evaluated. VMIs from 55 to 80 keV at 5-keV increments were reconstructed. EAT attenuation was manually measured on unenhanced and contrast-enhanced images. FAI was calculated using semiautomated software. RESULTS. The attenuation of the phantom fat insert was -69 HU for the reference EID CT; the closest attenuation for PCD CT was observed at 70 keV for the small (-69 HU) and large (-70 HU) phantoms. In patients, EAT attenuation increased for unenhanced acquisition from -111 ± 11 HU at 55 keV to -82 ± 9 HU at 80 keV and for contrast-enhanced acquisition from -104 ± 11 HU at 55 keV to -81 ± 9 HU at 80 keV. The mean attenuation difference between unenhanced and contrast-enhanced scans decreased with increasing energy level (from 7 ± 12 HU to 1 ± 10 HU). The FAI increased from -89 ± 8 HU at 55 keV to -77 ± 12 HU at 80 keV for the right coronary artery, -95 ± 11 HU at 55 keV to -85 ± 11 HU at 80 keV for the left anterior descending artery, and -87 ± 10 HU at 55 keV to -80 ± 12 HU at 80 keV for the circumflex artery. CONCLUSION. EAT attenuation and FAI measurements using PCD CT are impacted by VMI energy level and contrast enhancement. Use of VMI reconstruction at 70 keV provides fat attenuation approximating conventional polychromatic measurements. CLINICAL IMPACT. The findings may help standardize evaluation of pericoronary inflammation by PCD CT as a measure of patients' cardiac risk.


Asunto(s)
Tejido Adiposo , Tomografía Computarizada por Rayos X , Tejido Adiposo/diagnóstico por imagen , Adulto , Femenino , Humanos , Inflamación , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
5.
Skeletal Radiol ; 51(12): 2307-2315, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35773420

RESUMEN

OBJECTIVES: To compare the value of zero echo time (ZTE) and gradient echo "black bone" (BB) MRI sequences for bone assessment of the sacroiliac joint (SI) using computed tomography (CT) as the reference standard. MATERIALS AND METHODS: Between May 2019 and January 2021, 79 patients prospectively underwent clinically indicated 3-T MRI including ZTE and BB imaging. Additionally, all patients underwent a CT scan covering the SI joints within 12 months of the MRI examination. Two blinded readers performed bone assessment by grading each side of each SI joint qualitatively in terms of seven features (osteophytes, subchondral sclerosis, erosions, ankylosis, joint irregularity, joint widening, and gas in the SI joint) using a 4-point Likert scale (0 = no changes-3 = marked changes). Scores were compared between all three imaging modalities. RESULTS: Interreader agreement was largely good (k values: 0.5-0.83). Except for the feature "gas in SI joint" where ZTE exhibited significantly lower scores than CT (p < 0.001), ZTE and BB showed similar performance relative to CT for all other features (p > 0.52) with inter-modality agreement being substantial to almost perfect (Krippendorff's alpha coefficients: 0.724-0.983). When combining the data from all features except for gas in the SI joint and when binarizing grading scores, combined sensitivity/specificity was 76.7%/98.6% for ZTE and 80.8%/99.1% for BB, respectively, compared to CT. CONCLUSIONS: The performance of ZTE and BB sequences was comparable to CT for bone assessment of the SI joint. These sequences may potentially serve as an alternative to CT yet without involving exposure to ionizing radiation.


Asunto(s)
Imagen por Resonancia Magnética , Articulación Sacroiliaca , Huesos , Humanos , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Articulación Sacroiliaca/diagnóstico por imagen , Articulación Sacroiliaca/patología , Tomografía Computarizada por Rayos X/métodos
6.
Skeletal Radiol ; 51(3): 637-647, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34309690

RESUMEN

PURPOSE: To evaluate the MRI anatomy of the scapho-trapezial-trapezoidal (STT) ligament complex in asymptomatic and symptomatic individuals. MATERIAL AND METHODS: In this retrospective study, STT ligament complex of 42 (male 69%, median age 37.5 years) asymptomatic (n = 25) and symptomatic (n = 17) (defined as pain described over the STT joint) individuals was examined using a high-resolution 3D proton density-weighted isovoxel sequence (MR arthrogram) with multiplanar reconstructions. Two musculoskeletal radiologists independently assessed visibility, signal intensity (SI), morphology, and thickness of the radiopalmar scapho-trapezial ligament (rpSTL), palmar scapho-capitate capsular ligament (pSCL), palmar STT capsule (pSTTC), and dorsal STT capsule (dSTTC). RESULTS: Interreader agreement ranged from fair to good and intraclass correlations were good. The rpSTL was almost always visible (85.7%/80.1%; reader 1/reader 2). The pSCL and dSTTC were visible in all cases. The pSTTC was visible in only 52.4%/42.9%. Mean thickness of the rpSTL, pSCL, pSTTC, and dSTTC was 1.4 ± 0.5 mm/1.3 ± 0.5 mm, 2.8 ± 0.7 mm/2.7 ± 0.6 mm, 0.5 ± 0.5 mm/0.4 ± 0.4 mm, and 0.5 ± 0.3 mm/0.3 ± 0.3 mm. Both readers rated SI of the rpSTL significantly more often as increased in the symptomatic group (increased SI in asymptomatic group: 20%/15%; symptomatic group: 56%/50%) (p-values < 0.005). For all other ligaments, no significant difference was observed for SI between symptomatic and asymptomatic group (p-values ranging between 0.188 and 0.890). For all other ligaments, no significant differences were observed regarding ligament visibility, morphology, and thickness (p-values ranging between 0.274 and 1.000). CONCLUSION: The anatomy of the STT ligament complex can consistently be visualized on high-resolution 3D MRI. Increased signal intensity of rpSTL is significantly more frequent in patients with radial-sided wrist pain.


Asunto(s)
Articulaciones del Carpo , Articulación de la Muñeca , Adulto , Humanos , Ligamentos/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Estudios Retrospectivos
7.
Skeletal Radiol ; 50(2): 311-320, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32699954

RESUMEN

OBJECTIVE: To develop a new magnetic resonance imaging(MRI) scoring system for evaluation of active Charcot foot and to correlate the score with a duration of off-loading treatment ≥ 90 days. METHODS: An outpatient clinic database was searched retrospectively for MRIs of patients with active Charcot foot who completed off-loading treatment. Images were assessed by two radiologists (readers 1 and 2) and an orthopedic surgeon (reader 3). Sanders/Frykberg regions I-V were evaluated for soft tissue edema, bone marrow edema, erosions, subchondral cysts, joint destruction, fractures, and overall regional manifestation using a score according to degree of severity (0-3 points). Intraclass correlations (ICC) for interreader agreement and receiver operating characteristic analysis between MR findings and duration of off-loading-treatment were calculated. RESULTS: Sixty-five feet in 56 patients (34 men) with a mean age of 62.4 years (range: 44.5-85.5) were included. Region III (reader 1/reader 2: 93.6/90.8%) and region II (92.3/90.8%) were most affected. The most common findings in all regions were soft tissue edema and bone marrow edema. Mean time between MRI and cessation of off-loading-treatment was 150 days (range: 21-405). The Balgrist Score was defined in regions II and III using soft tissue edema, bone marrow edema, joint destruction, and fracture. Interreader agreement for Balgrist Score was excellent: readers 1/2: ICC 0.968 (95% CI: 0.948, 0.980); readers 1/2/3: ICC 0.856 (0.742, 0.917). A cutoff of ≥ 9.0 points in Balgrist Score (specificity 72%, sensitivity 66%) indicated a duration of off-loading treatment ≥ 90 days. CONCLUSION: The Balgrist Score is a new MR scoring system for assessment of active Charcot foot with excellent interreader agreement. The Balgrist Score can help to identify patients with off-loading treatment ≥ 90 days.


Asunto(s)
Enfermedades de la Médula Ósea , Pie Diabético , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Médula Ósea/diagnóstico por imagen , Edema , Pie , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
8.
Acta Radiol ; 59(11): 1309-1315, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29486599

RESUMEN

Background Computed tomography (CT) for excluding acute aortic syndrome (AAS) and pulmonary embolism (PE) simultaneously in patients with chest pain could be used to exclude coronary artery disease (CAD). Purpose To evaluate the frequency of further testing for CAD in patients receiving a CT in the emergency department (ED) for simultaneous evaluation for AAS and PE. Material and Methods This retrospective study was conducted over a three-year period including all patients with acute chest pain visiting our ED. All patients were included that received an electrocardiography (ECG)-gated CT of the entire chest enquiring simultaneously for AAS and PE. Those patients were followed up for 30 days after their initial ED visit whether they received further testing for CAD. Results Within the study period, a total of 157 patients with acute chest pain received a chest pain CT for simultaneous evaluation of both AAS and PE. Image quality was deemed sufficient to evaluate the coronary arteries in 80% of the patients. Thirty-seven patients (24%) underwent additional testing for CAD within 30 days of their ED visit, including catheter coronary angiography (n = 25), cardiac-stress single-photon emission-CT (n = 6), and cardiac magnetic resonance imaging (MRI) (n = 6). Conclusion Of patients presenting to the ED with acute chest pain who received a chest pain CT for simultaneous evaluation of AAS and PE, 24% had further imaging for CAD within 30 days of the initial ED visit. Immediate evaluation of the coronary arteries as part of a chest pain CT should be considered here for not delaying diagnosis.


Asunto(s)
Dolor en el Pecho/etiología , Dolor en el Pecho/fisiopatología , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Servicio de Urgencia en Hospital , Adulto , Anciano , Anciano de 80 o más Años , Dolor en el Pecho/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
9.
Pediatr Radiol ; 48(2): 165-175, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29143200

RESUMEN

BACKGROUND: Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. OBJECTIVE: To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. MATERIALS AND METHODS: We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. RESULTS: Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). CONCLUSION: Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation.


Asunto(s)
Fibrosis Quística/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Niño , Preescolar , Medios de Contraste , Fibrosis Quística/patología , Femenino , Humanos , Lactante , Pulmón/patología , Masculino , Meglumina , Compuestos Organometálicos , Técnicas de Imagen Sincronizada Respiratorias , Estudios Retrospectivos , Adulto Joven
11.
AJR Am J Roentgenol ; 208(1): 159-164, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27762599

RESUMEN

OBJECTIVE: The purpose of this study was to quantitatively and qualitatively determine the impact of radiation dose reduction on the image noise and quality of tomosynthesis studies of the wrist. MATERIALS AND METHODS: Imaging of six cadaver wrists was performed with tomosynthesis in anteroposterior position at a tube voltage of 60 kV and tube current of 80 mA and subsequently at 60 or 50 kV with different tube currents of 80, 40, or 32 mA. Dose-area products (DAP) were obtained from the electronically logged protocol. Image noise was measured with an ROI. Two independent and blinded readers evaluated all images. Interreader agreement was measured with a Cohen kappa. Readers assessed overall quality and delineation of soft tissue, cortical bone, and trabecular bone on a 4-point Likert scale. RESULTS: The highest DAP (3.892 ± 0.432 Gy · cm2) was recorded for images obtained with 60 kV and 80 mA; the lowest (0.857 ± 0.178 Gy · cm2) was recorded for images obtained with 50 kV and 32 mA. Noise was highest when a combination of 50 kV and 32 mA (389 ± 26.6) was used and lowest when a combination of 60 kV and 80 mA (218 ± 12.3) was used. The amount of noise on images acquired using 60 kV and 80 mA was statistically significantly different from the amount measured on all other images (p < 0.0001). Interreader agreement was excellent (κ = 0.93). Delineation of anatomy and overall quality were scored best on images obtained with 60 kV and 80 mA and worst on images obtained with 50 kV and 32 mA. The difference in delineation and quality on images obtained using 50 kV and 40 mA was not statistically significantly different compared with images obtained using 60 kV and 80 mA. CONCLUSION: Significant dose reduction for tomosynthesis of the wrist is possible while image quality and delineation of anatomic structures remain preserved.


Asunto(s)
Dosis de Radiación , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Protección Radiológica/métodos , Tomografía Computarizada por Rayos X/métodos , Articulación de la Muñeca/diagnóstico por imagen , Muñeca/diagnóstico por imagen , Anciano , Cadáver , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego
12.
Radiology ; 280(3): 960-8, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26937711

RESUMEN

Purpose To prospectively develop individualized low-volume contrast media (CM) protocols adapted to tube voltage in patients undergoing computed tomographic (CT) angiography of the aorta. Materials and Methods The study was approved by the institutional review board and local ethics committee. All patients provided written informed consent. CT angiography was performed by using automated attenuation-based tube voltage selection (ATVS) (range, 70-150 kVp; 10-kVp increments). Iodine attenuation curves from an ex vivo experiment in a phantom were used to design CM protocols for CT angiography of the thoracoabdominal aorta in 129 consecutive patients (hereafter, cohort A). Further modified CM protocols based on results in cohort A were designed with the aim of homogeneous vascular attenuation of 300-350 HU across tube voltages and were applied to another 61 consecutive patients (cohort B). Three independent blinded radiologists assessed subjective image quality, and one reader determined objective image quality. The Kruskal-Wallis test was performed to test for differences in subjective image quality, and linear regression was performed to test for differences in objective image quality between the automatically selected tube voltages. Results Experiments revealed tube voltage-dependent iodine attenuation curves, which were used to determine the CM protocols in cohort A; these ranged from 68 mL at 110 kVp to 45 mL at 80 kVp. In both cohorts, ATVS selected 80 kVp in 62 patients, 90 kVp in 84, 100 kVp in 33, and 110 kVp in 11. In cohort A, image quality that was satisfactory or better was attained in 126 (98%) of 129 patients who had no significant differences in subjective image quality between tube voltages (P = .106) but who did have significant differences in attenuation and contrast-to-noise ratio (CNR) (P < .001 for both). In cohort B, the further-modified CM protocol (from 33 mL at 80 kVp to 68 mL at 110 kVp) yielded image quality that was satisfactory or better in all 61 (100%) patients, without significant differences in subjective image quality (P = .178), and without significant differences between tube voltage and attenuation (P = .108), noise (P = .250), or CNR (P = .698). Conclusion Individualized low-volume CM protocols based on automatically selected tube voltages are feasible and yield diagnostic image quality for CT angiography of the aorta. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Medios de Contraste/administración & dosificación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador
13.
Eur Radiol ; 26(11): 3989-3999, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26847043

RESUMEN

OBJECTIVES: To determine the diagnostic and therapeutic impact of dual-energy computed tomography (DECT) in gout. METHODS: Forty-three patients with (n = 20) and without a history of gout (n = 23) showing non-specific soft tissue deposits underwent DECT after unrewarding arthrocentesis. Two blinded, independent readers evaluated DECT for the presence of urate crystals. Clinical diagnosis, clinically suspected urate crystal locations, diagnostic thinking and therapeutic decisions were noted before and after DECT. Clinical 1-month follow-up was obtained. RESULTS: DECT showed urate in 26/43 patients (60 %). After DECT, clinical diagnosis of gout was withdrawn in 17/43 (40 %) and was maintained in 16/43 patients (37 %). In 10/43 patients (23 %) the diagnosis was maintained, but DECT revealed urate in clinically unsuspected locations. In 23/43 patients (53 %), a treatment-change based on DECT occurred. Changes in diagnostic thinking occurred more frequently in patients without a history of gout (p < 0.001), changes in therapeutic decisions more frequently in patients with a history of gout (p = 0.014). Clinical follow-up indicated beneficial effects of DECT-based diagnoses in 83 % of patients. CONCLUSIONS: In patients with or without a history of gout and a recent suspicion for gouty arthritis with an unrewarding arthrocentesis, DECT has a marked diagnostic and therapeutic impact when hyperdense soft-tissue deposits are present. KEY POINTS: • This study evaluates the concept of evidence-based radiology • In patients with suspected gout, DECT can help clinicians make the diagnosis • DECT has a marked impact on therapy • Clinical follow-up after 1 month indicated reliable results of DECT.


Asunto(s)
Artritis Gotosa/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Ácido Úrico
14.
Acad Radiol ; 31(1): 212-220, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37532596

RESUMEN

RATIONALE AND OBJECTIVES: To determine the optimal virtual monoenergetic image (VMI) energy level and the potential of contrast-media (CM) reduction for coronary computed tomography angiography (CCTA) with photon-counting detector CT (PCD-CT). MATERIALS AND METHODS: In this institutional review board-approved study, patients who underwent CCTA with dual-source PCD-CT with an identical scan protocol and radiation dose were included. In group 1, CCTA was performed with our standard CM protocol (volume: 72-85.2 mL, 370 mg iodine/mL). VMIs were reconstructed from 40 to 60 keV at 5 keV increments. Objective image quality (IQ) (vascular attenuation, image noise, and contrast-to-noise ratio [CNR]) was measured. Two blinded, independent readers rated subjective IQ (overall IQ, subjective image contrast, and subjective noise using a five-point discrete visual scale). Results of group 1 served to determine the best VMI level for CCTA. In group 2, CM volume was reduced by 20%, and in group 3 by another 20%. RESULTS: A total of 100 patients were enrolled (45 females, mean age 54 ± 13 years). Inter-reader agreement was good-to-excellent for all comparisons (κ > 0.6). In group 1, the best VMI level regarding objective and subjective IQ was 45 keV, which was selected as the reference for groups 2 and 3. For group 2, mean vascular attenuation was 890 Hounsfield units (HU) and mean CNR was 26, with no differences compared to group 1, 45 keV for both objective and subjective IQ. For group 3, mean vascular attenuation was 676 HU and mean CNR was 21, and all patients were rated as diagnostic except one (severe motion artifacts). CONCLUSION: Increased IQ of PCD-CT can be used for considerable CM volume reduction while still maintaining a diagnostic IQ of CCTA.


Asunto(s)
Angiografía por Tomografía Computarizada , Imagen Radiográfica por Emisión de Doble Fotón , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Relación Señal-Ruido , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos
15.
Am J Sports Med ; 51(1): 160-168, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36412545

RESUMEN

BACKGROUND: The best treatment of degenerative hip abductor tendon lesions remains largely unknown, as the natural course of the disease has not yet been reported. The aim of the present study was to investigate the natural history of symptomatic degenerative hip abductor lesions. HYPOTHESIS: Nonoperatively treated hip abductor lesions progress over time, resulting in refractory hip pain and low functional outcomes. STUDY DESIGN: Case series (prognosis); Level of evidence, 4. METHODS: Consecutive patients with greater trochanteric pain syndrome and degenerative changes on magnetic resonance imaging (MRI) of the symptomatic hip were included. Bilateral hip MRI scans and a clinical examination were performed at a minimum follow-up of 36 months to study the type and location of hip abductor lesion. Progression of a lesion was defined as a more severe lesion as compared with the initial MRI results or if the lesion extended to another, initially not involved, trochanteric facet. The muscle's fatty infiltration (FI) was also described. RESULTS: From 106 patients identified, 58 patients (64 hips) aged 66 ± 14 years (mean ± SD) agreed to return to the clinic for follow-up MRI and met the inclusion criteria. At a mean 71-month follow-up, an overall 34% (22/64) of lesions had progressed over time: from trochanteric bursitis to tendinopathy (9/64, 14%) or partial tear (5/64, 8%), from tendinopathy to partial tear (4/64, 6%), from a partial to complete tear (3/64, 4.5%), and with 1 complete tear (1/64, 1.5%) extending to another trochanteric facet. Interestingly, 90% of partial tears remained stable or transformed into a scar. Although patients with a progressive lesion experienced more trochanteric pain (visual analog scale, 4.6 vs 2.8; P = .001), the functional outcomes were comparable with patients with a stable lesion. The majority of hips with a partial tear (64%) demonstrated a progression of gluteus minimus FI from a median grade of 1 to 2, whereas only 1 hip (3%) progressed from grade 2 to 3. Only 3 hips (9%) with a partial tear had a progression of gluteus medius FI, which did not differ significantly from the contralateral unaffected side. CONCLUSION: Nonoperative treatment might be a valid long-term option for degenerative hip abductor lesions, especially for partial tears, which demonstrated a low risk of clinically relevant progression or muscle FI and similar clinical outcomes to those reported in the literature for operatively treated hip abductor tendon lesions.


Asunto(s)
Bursitis , Tendinopatía , Humanos , Tendones/cirugía , Músculo Esquelético/cirugía , Tendinopatía/diagnóstico por imagen , Tendinopatía/terapia , Tendinopatía/patología , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Articulación de la Cadera/patología , Imagen por Resonancia Magnética/métodos , Artralgia
16.
Invest Radiol ; 58(11): 767-774, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37222522

RESUMEN

PURPOSE: The aim of this study was to assess the effect of temporal resolution on subjective and objective image quality of coronary computed tomography angiography (CCTA) in the ultra-high-resolution (UHR) mode with dual-source photon-counting detector (PCD) CT. MATERIALS AND METHODS: This retrospective, institutional review board-approved study evaluated 30 patients (9 women; mean age, 80 ± 10 years) undergoing UHR CCTA with a clinical dual-source PCD-CT scanner. Images were acquired with a tube voltage of 120 kV and using a collimation of 120 × 0.2 mm. Gantry rotation time was 0.25 seconds. Each scan was reconstructed using both single-source and dual-source data resulting in an image temporal resolution of 125 milliseconds and 66 milliseconds, respectively. The average heart rate and the heart rate variability were recorded. Images were reconstructed with a slice thickness of 0.2 mm, quantum iterative reconstruction strength level 4, and using the Bv64 and Bv72 kernel for patients without and with coronary stents, respectively. For subjective image quality, 2 experienced readers rated motion artifacts and vessel delineation, or in-stent lumen visualization using 5-point discrete visual scales. For objective image quality, signal-to-noise ratio, contrast-to-noise ratio, stent blooming artifacts, and vessel and stent sharpness were quantified. RESULTS: Fifteen patients had coronary stents, and 15 patients had no coronary stents. The mean heart rate and heart rate variability during data acquisition were 72 ± 10 beats per minute and 5 ± 6 beats per minute, respectively. Subjective image quality in the right coronary artery, left anterior descending, and circumflex artery was significantly superior in 66 milliseconds reconstructions compared with 125 milliseconds reconstructions for both readers (all P 's < 0.01; interreader agreement, Krippendorff α = 0.84-1.00). Subjective image quality deteriorated significantly at higher heart rates for 125 milliseconds (ρ = 0.21, P < 0.05) but not for 66 milliseconds reconstructions (ρ = 0.11, P = 0.22). No association was found between heart rate variability and image quality for both 125 milliseconds (ρ = 0.09, P = 0.33) and 66 milliseconds reconstructions (ρ = 0.13, P = 0.17), respectively. Signal-to-noise ratio and contrast-to-noise ratio were similar between 66 milliseconds and 125 milliseconds reconstructions (both P 's > 0.05), respectively. Stent blooming artifacts were significantly lower on 66 milliseconds than on 125 milliseconds reconstructions (46.7% ± 10% vs 52.9% ± 8.9%, P < 0.001). Higher sharpness was found in 66 milliseconds than in 125 milliseconds reconstructions both in native coronary arteries (left anterior descending artery: 1031 ± 265 ∆HU/mm vs 819 ± 253 ∆HU/mm, P < 0.01; right coronary artery: 884 ± 352 ∆HU/mm vs 654 ± 377 ∆HU/mm, P < 0.001) and stents (5318 ± 3874 ∆HU/mm vs 4267 ± 3521 ∆HU/mm, P < 0.001). CONCLUSIONS: Coronary angiography with PCD-CT in the UHR mode profits considerably from a high temporal resolution, resulting in less motion artifacts, superior vessel delineation and in-stent lumen visualization, less stent blooming artifacts, and superior vessel and stent sharpness.


Asunto(s)
Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Angiografía Coronaria/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Angiografía por Tomografía Computarizada/métodos , Stents , Fantasmas de Imagen
17.
Radiol Cardiothorac Imaging ; 5(1): e220140, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36860835

RESUMEN

Purpose: To develop and evaluate a low-volume contrast media protocol for thoracoabdominal CT angiography (CTA) with photon-counting detector (PCD) CT. Materials and Methods: This prospective study included consecutive participants (April-September 2021) who underwent CTA with PCD CT of the thoracoabdominal aorta and previous CTA with energy-integrating detector (EID) CT at equal radiation doses. In PCD CT, virtual monoenergetic images (VMI) were reconstructed in 5-keV intervals from 40 to 60 keV. Attenuation of the aorta, image noise, and contrast-to-noise ratio (CNR) were measured, and subjective image quality was rated by two independent readers. In the first group of participants, the same contrast media protocol was used for both scans. CNR gain in PCD CT compared with EID CT served as the reference for contrast media volume reduction in the second group. Noninferiority analysis was used to test noninferior image quality of the low-volume contrast media protocol with PCD CT. Results: The study included 100 participants (mean age, 75 years ± 8 [SD]; 83 men). In the first group (n = 40), VMI at 50 keV provided the best trade-off between objective and subjective image quality, achieving 25% higher CNR compared with EID CT. Contrast media volume in the second group (n = 60) was reduced by 25% (52.5 mL). Mean differences in CNR and subjective image quality between EID CT and PCD CT at 50 keV were above the predefined boundaries of noninferiority (-0.54 [95% CI: -1.71, 0.62] and -0.36 [95% CI: -0.41, -0.31], respectively). Conclusion: CTA of the aorta with PCD CT was associated with higher CNR, which was translated into a low-volume contrast media protocol demonstrating noninferior image quality compared with EID CT at the same radiation dose.Keywords: CT Angiography, CT-Spectral, Vascular, Aorta, Contrast Agents-Intravenous, Technology Assessment© RSNA, 2023See also the commentary by Dundas and Leipsic in this issue.

20.
Invest Radiol ; 57(7): 488-493, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35136003

RESUMEN

OBJECTIVES: The aim of this study was to assess the accuracy of virtual noncontrast (VNC) images of the liver in a phantom and patients using dual-source photon-counting detector computed tomography (PCD-CT). MATERIALS AND METHODS: An anthropomorphic abdominal phantom with a liver insert containing liver parenchyma (1.4 mgI/mL) and 19 liver lesions (iodine content 0-5 mgI/mL) was imaged on a clinical dual-source PCD-CT (tube voltage 120 kV) and in the dual-energy mode on a dual-source energy-integrating detector (EID) CT (tube voltage combinations, 80/Sn150 kV, 90/Sn150 kV, and 100/Sn150 kV). Rings of fat-equivalent material were added to the phantom to emulate 3 sizes (small, medium, large). Each setup was imaged at 3 different radiation doses (volume CT dose index: 5, 10, and 15 mGy). Virtual noncontrast images were reconstructed and CT attenuation was measured in each lesion and liver parenchyma. The absolute error of CT attenuation (VNCerror) was calculated using the phantom specifications as reference. In addition, 15 patients with hypodense liver lesions who were clinically scanned on PCD-CT were retrospectively included. Attenuation values in lesions and liver parenchyma in VNC images reconstructed from portal venous phase CT were compared with true noncontrast images. Statistical analysis included analysis of variance with post hoc t tests and generalized linear models to assess the impact of various variables (dose, patient size, base material, iodine content, and scanner/scan mode) on quantification accuracy. RESULTS: In the phantom, the overall mean VNCerror for PCD-CT was 4.1 ± 3.9 HU. The overall mean VNCerror for EID-CT was 7.5 ± 5, 6.3 ± 4.7, and 6.7 ± 4.8 HU for 80/Sn150 kV, 90/Sn150 kV, and 100/Sn150 kV, respectively, with the VNCerror of EID-CT being significantly higher at all tube voltage settings (P < 0.001), even after adjusting for dose, size, iodine content of the lesion, and attenuation of base material. For PCD-CT, a smaller phantom size was associated with higher quantification accuracy (P = 0.007-0.046), whereas radiation dose did not impact accuracy (P > 0.126). For EID-CT, but not for PCD-CT, VNCerror increased with lesion iodine content (P < 0.001). In patients, there was no difference in attenuation measured on true noncontrast and VNC images (P = 0.093), with a mean VNCerror of 3.7 ± 2.2 HU. CONCLUSIONS: Photon-counting detector CT allows for the reconstruction of VNC images of the liver both in a phantom and in patients with accurate attenuation values, being independent of dose, attenuation of base material, and liver iodine content.


Asunto(s)
Yodo , Neoplasias Hepáticas , Humanos , Fantasmas de Imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos