Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Clin Immunol ; 41(2): 458-469, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33409867

RESUMEN

PURPOSE: To evaluate the safety and tolerability of subcutaneous IgPro20 (Hizentra®, CSL Behring, King of Prussia, PA, USA) administered at high infusion parameters (> 25 mL and > 25 mL/h per injection site) in patients with primary immunodeficiency. METHODS: The Hizentra® Label Optimization (HILO) study was an open-label, parallel-arm, non-randomized study (NCT03033745) of IgPro20 using a forced upward titration design for infusion parameters. Patients experienced with pump-assisted IgPro20 infusions received weekly IgPro20 infusions at a stable dose in the Pump-Assisted Volume Cohort (N = 15; 25-50 mL per injection site) and in the Pump-Assisted Flow Rate Cohort (N = 18; 25-100 mL/h per injection site). Responder rates (percentage of patients who successfully completed ≥ 75% of planned infusions), safety outcomes, and serum immunoglobulin G (IgG) trough levels were evaluated. RESULTS: Responder rates were 86.7% (13/15, 25 mL) and 73.3% (11/15, 40 and 50 mL) in the Volume Cohort, and 77.8% (14/18, 25 and 50 mL/h), 66.7% (12/18, 75 mL/h), and 61.1% (11/18, 100 mL/h) in the Flow Rate Cohort. Infusion compliance was ≥ 90% in all patients in the Volume Cohort and in 83.3% of patients in the Flow Rate Cohort. The number of injection sites (Volume Cohort) and the infusion duration (Flow Rate Cohort) decreased with increasing infusion parameters. The rate of treatment-emergent adverse events per infusion was low (0.138 [Volume Cohort] and 0.216 [Flow Rate Cohort]). Serum IgG levels remained stable during the study. CONCLUSION: Pump-assisted IgPro20 infusions are feasible at 50 mL and 100 mL/h per injection site in treatment-experienced patients, which may result in fewer injection sites and shorter infusion times. TRIAL REGISTRATION: NCT03033745 ; registered January 27, 2017.


Asunto(s)
Inmunoglobulina G/administración & dosificación , Inmunoglobulina G/efectos adversos , Síndromes de Inmunodeficiencia/inmunología , Síndromes de Inmunodeficiencia/terapia , Enfermedades de Inmunodeficiencia Primaria/inmunología , Enfermedades de Inmunodeficiencia Primaria/terapia , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Inmunoglobulina G/inmunología , Inmunoglobulinas Intravenosas/efectos adversos , Bombas de Infusión/efectos adversos , Infusiones Subcutáneas/efectos adversos , Masculino , Persona de Mediana Edad , Adulto Joven
2.
J Clin Immunol ; 41(1): 66-75, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33025378

RESUMEN

PURPOSE: To evaluate the safety and tolerability of IgPro20 manual push (also known as rapid push) infusions at flow rates of 0.5-2.0 mL/min. METHODS: Patients with primary immunodeficiency (PID) with previous experience administering IgPro20 (Hizentra®, CSL Behring, King of Prussia, PA, USA) were enrolled in the Hizentra® Label Optimization (HILO) study (NCT03033745) and assigned to Pump-assisted Volume Cohort, Pump-assisted Flow Rate Cohort, or Manual Push Flow Rate Cohort; this report describes the latter. Patients administered IgPro20 via manual push at 0.5, 1.0, and 2.0 mL/min/site for 4 weeks each. Responder rates (percentage of patients who completed a predefined minimum number of infusions), safety outcomes, and serum immunoglobulin G (IgG) trough levels were evaluated. RESULTS: Sixteen patients were treated; 2 patients (12.5%) discontinued at the 1.0-mL/min level (unrelated to treatment). Responder rates were 100%, 100%, and 87.5% at 0.5-, 1.0-, and 2.0-mL/min flow rates, respectively. Mean weekly infusion duration decreased from 103-108 to 23-28 min at the 0.5- and 2.0-mL/min flow rates, respectively. Rates of treatment-related treatment-emergent adverse events (TEAEs) per infusion were 0.023, 0.082, and 0.025 for the 0.5-, 1.0-, and 2.0-mL/min flow rates, respectively. Most TEAEs were mild local reactions and tolerability (infusions without severe local reactions/total infusions) was 100% across flow rate levels. Serum IgG levels (mean [SD]) were similar at study start (9.36 [2.53] g/L) and end (9.58 [2.12] g/L). CONCLUSIONS: Subcutaneous IgPro20 manual push infusions at flow rates up to 2.0 mL/min were well tolerated and reduced infusion time in treatment-experienced patients with PID. TRIAL REGISTRATION: NCT03033745.


Asunto(s)
Inmunoglobulina G/administración & dosificación , Enfermedades de Inmunodeficiencia Primaria/tratamiento farmacológico , Adolescente , Adulto , Anciano , Manejo de la Enfermedad , Monitoreo de Drogas , Femenino , Humanos , Inmunoglobulina G/efectos adversos , Bombas de Infusión , Infusiones Subcutáneas , Inyecciones Subcutáneas , Masculino , Persona de Mediana Edad , Cooperación del Paciente , Enfermedades de Inmunodeficiencia Primaria/diagnóstico , Enfermedades de Inmunodeficiencia Primaria/etiología , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA