Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int Orthop ; 46(10): 2257-2264, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35844015

RESUMEN

PURPOSE: The proximal chevron osteotomy and the modified Lapidus arthrodesis are both procedures utilized for deformity correction in patients with severe symptomatic hallux valgus. The aim of the current study was to compare their biomechanical stability when using locking plate fixation. METHODS: Twelve matched pairs of human anatomical lower leg specimens underwent on one side a proximal chevron osteotomy with a medial locking plate and on the other side a modified Lapidus arthrodesis with a plantar locking plate utilizing an interfragmentary compression screw. All specimens underwent bone mineral density (BMD) assessment and were tested in a servohydraulic load frame which applied a load on the centre of the metatarsal head over 1000 loading cycles with subsequently ultimate load testing. Displacement of the proximal and distal bone segment, ultimate load, and bending stiffness were analyzed. RESULTS: Mean displacement of both procedures showed no statistically significant difference throughout all the loading cycles (0.213 ≤ p ≤ 0.834). The mean ultimate load of the proximal chevron osteotomy was 227.9 N (± 232.4) and of the modified Lapidus arthrodesis 162.9 N (± 74.6) (p = 0.754). The proximal chevron osteotomy (38.2 N/mm (± 24.9)) had a significantly higher bending stiffness compared to the modified Lapidus arthrodesis (17.3 N/mm (± 9.9)) (p = 0.009). There was no correlation between BMD and displacement in all loading cycles, ultimate load, and bending stiffness of either procedure (p > 0.05). CONCLUSION: Although the bending stiffness of the chevron osteotomy was higher, there was no statistically significant difference between the surgical techniques in mean displacement and ultimate load. The BMD did not influence the overall stability of either reconstruction. Locking plate fixation increases the clinical value of the modified Lapidus arthrodesis by outweighing most of the biomechanical disadvantages in comparison to the proximal chevron osteotomy.


Asunto(s)
Hallux Valgus , Huesos Metatarsianos , Artrodesis/efectos adversos , Artrodesis/métodos , Placas Óseas , Hallux Valgus/cirugía , Humanos , Huesos Metatarsianos/cirugía , Osteotomía/efectos adversos , Osteotomía/métodos
2.
Int Orthop ; 45(4): 837-846, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33247312

RESUMEN

PURPOSE: Besides other diagnostic test methods, established serum inflammatory markers such as serum C-reactive protein or leukocyte count are widely used preoperatively to aid in diagnosing periprosthetic joint infections (PJI). Although low accuracies were reported, these parameters are easily accessible and routinely available. Novel biomarkers with promising results in diagnosing PJI (platelet count to mean platelet volume ratio) or other infectious conditions (percentage of neutrophils, neutrophils to lymphocytes ratio) were described. The purpose of this study was to investigate the diagnostic value of established and novel serum inflammatory biomarkers for the diagnosis of PJI so as to compare the results to find the serum inflammatory marker with the best performance. METHODS: In 177 patients with a previous total hip (n = 91) or knee (n = 86) arthroplasty and indicated revision surgery, the diagnostic value of the routinely available serum inflammatory markers C-reactive protein (CRP), white blood cell count (WBC), percentage of neutrophils (%N), neutrophils to lymphocytes ratio (NLR), fibrinogen and platelet count to mean platelet volume ratio (PC/mPV) were examined retrospectively via receiver operating characteristic curve analysis (AUC). The curves were compared using the z-test. RESULTS: Sensitivities of serum CRP, WBC, %N, NLR, fibrinogen and PC/mPV were calculated with 68%, 36%, 66%, 63%, 69% and 43%, respectively. Specificities were 87%, 89%, 67%, 73%, 89% and 81%, respectively. Serum CRP (0.78) and fibrinogen (0.79) showed significantly better AUCs compared with serum WBC (0.63), %N (0.67), NLR (0.68) and PC/mPV (0.62) (p < 0.0001). Patients with PJI caused by a low-virulent microorganism (median CRP: 17.6 mg/L) obtained lower CRP levels compared with infections caused by high-virulent microorganisms (median CRP: 49.2 mg/L; p = 0.044). The combination of CRP and fibrinogen showed a better sensitivity (77%) with similar specificity (83%) than one method alone but not at a significant level (CRP (p = 0.200); fibrinogen (p = 0.437)). CONCLUSION: Serum CRP and fibrinogen showed the best accuracies among these widely available serum inflammatory parameters. However, due to the insufficient performance, these biomarkers can only be recommended as suggestive criteria in diagnosing PJI. The preoperative workup should always be complemented by more specific tests such as synovial fluid analysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Artroplastia de Reemplazo de Cadera/efectos adversos , Biomarcadores , Sedimentación Sanguínea , Proteína C-Reactiva/análisis , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Sensibilidad y Especificidad , Líquido Sinovial/química
3.
Lab Invest ; 99(5): 648-658, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30679758

RESUMEN

Fibroblast-like synoviocytes (FLS) are major contributors to joint inflammation in rheumatoid arthritis (RA). Forkhead box O 3 (FOXO3) perturbations in immune cells are increasingly linked to RA pathogenesis. Here, we show that FOXO3 is distinctly inactivated/phosphorylated in the FLS of rheumatoid synovitis. In vitro, stimulation of FLS with tumor necrosis factor-alpha α (TNFα) induced a rapid and sustained inactivation of FOXO3. mRNA profiling revealed that the inactivation of FOXO3 is important for the sustained pro-inflammatory interferon response to TNFα (CXCL9, CXCL10, CXCL11, and TNFSF18). Mechanistically, our studies demonstrate that the inactivation of FOXO3 results from TNF-induced downregulation of phosphoinositide-3-kinase-interacting protein 1 (PIK3IP1). Thus, we identified FOXO3 and its modulator PIK3IP1 as a critical regulatory circuit for the inflammatory response of the resident mesenchymal cells to TNFα and contribute insight into how the synovial tissue brings about chronic inflammation that is driven by TNFα.


Asunto(s)
Fibroblastos/efectos de los fármacos , Proteína Forkhead Box O3/genética , Inflamación/genética , Sinoviocitos/efectos de los fármacos , Factor de Necrosis Tumoral alfa/farmacología , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/genética , Artritis Reumatoide/metabolismo , Artritis Reumatoide/patología , Células Cultivadas , Femenino , Fibroblastos/citología , Fibroblastos/metabolismo , Proteína Forkhead Box O3/metabolismo , Regulación de la Expresión Génica/efectos de los fármacos , Humanos , Inflamación/metabolismo , Péptidos y Proteínas de Señalización Intracelular/genética , Péptidos y Proteínas de Señalización Intracelular/metabolismo , Masculino , Proteínas de la Membrana/genética , Proteínas de la Membrana/metabolismo , Persona de Mediana Edad , Sinoviocitos/citología , Sinoviocitos/metabolismo
4.
Clin Orthop Relat Res ; 477(2): 461-466, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30418277

RESUMEN

BACKGROUND: One of the most commonly identified pathogens responsible for orthopaedic implant infection is Staphylococcus epidermidis, which can form biofilms on surfaces. Currently, orthopaedic implants made of various surface materials are available, each with features influencing osseointegration, biocompatibility, and adherence of bacteria to the surface, which is the first step in biofilm formation. The aim of this experimental study was to investigate the effect of a high tribologic-resistant 2.5-µm zirconium nitride top coat on an antiallergic multilayer ceramic-covered cobalt-chromium-molybdenum surface on the formation of S. epidermidis biofilm compared with other commonly used smooth and rough orthopaedic implant surface materials. QUESTIONS/PURPOSES: (1) When evaluating the surfaces of a cobalt-chromium-molybdenum (CoCrMo) alloy with a zirconium (Zr) nitride coating, a CoCrMo alloy without a coating, titanium alloy, a titanium alloy with a corundum-blasted rough surface, and stainless steel with a corundum-blasted rough surface, does a Zr coating reduce the number of colony-forming units of S. epidermidis in an in vitro setting? (2) Is there quantitatively less biofilm surface area on Zr-coated surfaces than on the other surfaces tested in this in vitro model? METHODS: To determine bacterial adhesion, five different experimental implant surface discs were incubated separately with one of 31 different S. epidermidis strains each and subsequently sonicated. Twenty test strains were obtained from orthopaedic patients undergoing emergency hip prosthesis surgeries or revision of implant infection and 10 further strains were obtained from the skin of healthy individuals. Additionally, one reference strain, S. epidermidis DSM 3269, was tested. After serial dilutions, the number of bacteria was counted and expressed as colony-forming units (CFUs)/mL. For biofilm detection, discs were stained with 0.1% Safranin-O for 15 minutes, photographed, and analyzed with computer imaging software. RESULTS: The lowest bacterial count was found in the CoCrMo + Zr surface disc (6.6 x 10 CFU/mL ± 4.6 x 10 SD) followed by the CoCrMo surface (1.1 x 10 CFU/mL ± 1.9 x 10 SD), the titanium surface (1.36 x 10 CFU/mL ± 1.8 x 10 SD), the rough stainless steel surface (2.65 x 10 CFU/mL ± 3.8 x 10 SD), and the rough titanium surface (2.1 x 10 CFU/mL ± 3.0 x 10 SD). The mean CFU count was lower for CoCrMo + Zr discs compared with the rough stainless steel surface (mean difference: 2.0 x 10, p = 0.021), the rough titanium alloy surface (mean difference: 1.4 x 10, p = 0.002), and the smooth titanium surface (mean difference: 7.0 x 10, p = 0.016). The results of biofilm formation quantification show that the mean covered area of the surface of the CoCrMo + Zr discs was 19% (± 16 SD), which was lower than CoCrMo surfaces (35% ± 23 SD), titanium alloy surface (46% ± 20 SD), rough titanium alloy surface (66% ± 23 SD), and rough stainless steel surface (58% ± 18 SD). CONCLUSIONS: These results demonstrate that a multilayer, ceramic-covered, CoCrMo surface with a 2.5-µm zirconium nitride top coat showed less S. epidermidis biofilm formation compared with other surface materials used for orthopaedic implants. CLINICAL RELEVANCE: CoCrMo with a 2.5-µm zirconium nitride top coat seems to be a promising surface modification technology able to reduce bacterial attachment on the surface of an implant and, hence, may further prevent implant infection with S. epidermidis biofilm formation.


Asunto(s)
Antibacterianos/farmacología , Biopelículas/efectos de los fármacos , Materiales Biocompatibles Revestidos/efectos adversos , Prótesis Articulares/efectos adversos , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones Estafilocócicas/prevención & control , Staphylococcus epidermidis/efectos de los fármacos , Circonio/farmacología , Adhesión Bacteriana/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Prótesis Articulares/microbiología , Ensayo de Materiales , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Estafilocócicas/microbiología , Staphylococcus epidermidis/crecimiento & desarrollo , Propiedades de Superficie
5.
BMC Musculoskelet Disord ; 20(1): 47, 2019 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-30704448

RESUMEN

BACKGROUND: Substantial bone loss following failed total knee arthroplasty (TKA) represents a major challenge in revision arthroplasty, that can require distal femoral reconstruction (DFR). In this study, we aimed to assess the clinical outcome and the complication frequencies of individuals who underwent DFR with modular megaprostheses. Additionally, we aimed to compare functional outcome measures after DFR in these sophisticated cases to an age-matched control group of total knee prostheses to quantify the potential loss of function. METHODS: A retrospective chart review of 30 consecutive patients after DFR from 1997 to 2017 with a mean age of 74.38 years (± 10.1) was performed. Complications were classified according to the Henderson classification. Knee Society Score (KSS) was calculated and range of motion (ROM) was assessed. RESULTS: Thirteen (43.3%) patients had at least one complication requiring revision surgery. Revision-free survival was 74.8% at one year, 62.5% at three and 40.9% at 10 years post-op. Soft-tissue failure complications were found in three (10.0%) patients, aseptic loosening in four (13.3%) patients, structural failure in one (3.3%) patient and infection in eight (26.6%) patients. Of those with infection, five (16.6%) experienced ongoing prosthetic joint infection and three (10.0%) developed new infection after distal femur reconstruction. Patients with DFR achieved 69.3% of KSS pain score, 23.1% KSS function score and 76.2% of ROM compared to patients with primary TKA. CONCLUSIONS: DFR after failed TKA represents a treatment procedure with high risk for complication in this particular group. Despite the prospect of rapid postoperative mobilization, reduced functionality, range of motion and mobilization have to be considered when choosing this treatment option.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla/efectos adversos , Complicaciones Posoperatorias/epidemiología , Falla de Prótesis , Reoperación/efectos adversos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Masculino , Complicaciones Posoperatorias/etiología , Rango del Movimiento Articular , Reoperación/instrumentación , Estudios Retrospectivos , Resultado del Tratamiento
6.
Int Orthop ; 43(8): 1891-1898, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30191275

RESUMEN

PURPOSE: The aim of this study was to evaluate the pre-operative performance of an automated multiplex PCR (mPCR) system in patients with suspected periprosthetic joint infection (PJI). METHODS: Under sterile conditions, synovial fluid samples from patients with a suspected PJI were collected pre-operatively. One hundred eighty microliter of the aspirate was used for analysis in the mPCR. The remaining joint fluid was sent for microbiological analysis. PJI was diagnosed by using the Musculoskeletal Infection Society (MSIS) criteria. Total percentage agreement and Cohen's kappa coefficient were calculated to measure overall agreement. RESULTS: Overall, 90 patients with a suspected PJI were included. Using MSIS criteria, 38 (42%) patients were classified as septic. Total percent agreement between mPCR and synovial fluid culture was 86% with a Cohen's kappa of 0.68. The mPCR and synovial fluid culture showed sensitivities of 71% and 84%, respectively. Combined evaluation provided an even higher sensitivity of 92%. While Cutibacterium spp. were detected five times by mPCR, it could only be cultured once. A higher detection rate of CoNS by mPCR (n = 7) compared to conventional culture (n = 5) was also demonstrated. In comparison to synovial fluid culture, the mPCR missed Staphylococcus aureus five times. CONCLUSION: With a moderate agreement between synovial fluid mPCR and culture, the mPCR system could be a useful adjunct in diagnosing a PJI pre-operatively. Due to faster availability of results and a higher detection rate of low-virulent microorganisms, it can complement conventional culture.


Asunto(s)
Reacción en Cadena de la Polimerasa Multiplex/métodos , Infecciones Relacionadas con Prótesis/microbiología , Líquido Sinovial/microbiología , Adulto , Anciano , Anciano de 80 o más Años , Técnicas Bacteriológicas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Infecciones Relacionadas con Prótesis/diagnóstico , Sensibilidad y Especificidad
7.
Acta Orthop ; 90(2): 105-110, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30669912

RESUMEN

Background and purpose - For decision-making (aseptic vs. septic), surgeons rely on intraoperatively available tests when a periprosthetic joint infection (PJI) cannot be confirmed or excluded preoperatively. We compared and evaluated the intraoperative performances of the frozen section and the alpha defensin lateral flow test in the diagnosis of PJI. Patients and methods - In this prospective study, consecutive patients with indicated revision surgery after arthroplasty were included. Patients were classified as having PJI using the MusculoSkeletal Infection criteria. The presence of alpha defensin was determined using the lateral flow test intraoperatively. During revision surgery, tissue samples were harvested for frozen and permanent section. Analysis of diagnostic accuracy was based on receiver-operating characteristics. Results - 101 patients (53 hips, 48 knees) were eligible for inclusion. Postoperatively, 29/101 patients were diagnosed with PJI, of which 8/29 cases were definitely classified as septic preoperatively. Of the remainder 21 septic cases, the intraoperative alpha defensin test and frozen section were positive in 13 and 17 patients, respectively. Sensitivities of the alpha defensin test and frozen section were 69% and 86%, respectively. The area under the curves of both tests showed a statistically significant difference (p = 0.006). Interpretation - The frozen section showed a significantly higher performance compared with the alpha defensin test and a near perfect concordance with the definitive histology, and therefore remains an appropriate intraoperative screening test in diagnosing PJI. Although the sensitivity of the alpha defensin test was lower compared with that of frozen section, this test is highly specific for confirming the diagnosis of PJI.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Secciones por Congelación/métodos , Cuidados Intraoperatorios/métodos , Infecciones Relacionadas con Prótesis/diagnóstico , Reoperación/métodos , alfa-Defensinas/análisis , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Prótesis de Cadera/efectos adversos , Prótesis de Cadera/microbiología , Humanos , Prótesis de la Rodilla/efectos adversos , Prótesis de la Rodilla/microbiología , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/cirugía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Rheumatology (Oxford) ; 57(3): 572-577, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29228301

RESUMEN

Objectives: The aim was to explore the function of the T-cell cytokine IFNγ for mesenchymal tissue remodelling in RA and to determine whether IFNγ signalling controls the invasive potential of fibroblast-like synoviocytes (FLS). Methods: To assess architectural responses, FLS were cultured in three-dimensional micromasses. FLS motility was analysed in migration and invasion assays. Signalling events relevant to cellular motility were defined by western blots. Baricitinib and small interfering RNA pools were used to suppress Janus kinase (JAK) functions. Results: Histological analyses of micromasses revealed unique effects of IFNγ on FLS shape and tissue organization. This was consistent with accelerated migration upon IFNγ stimulation. Given that cell shape and cell motility are under the control of the focal adhesion kinase (FAK), we next analysed its activity. Indeed, IFNγ stimulation induced the phosphorylation of FAK-Y925, a phosphosite implicated in FAK-mediated cell migration. Small interfering RNA knockdown of JAK2, but not JAK1, substantially abrogated FAK activation by IFNγ. Correspondingly, IFNγ-induced FAK activation and invasion of FLS was abrogated by the JAK inhibitor, baricitinib. Conclusion: Our study contributes insight into the synovial response to IFNγ and reveals JAK2 as a potential therapeutic target for FLS-mediated joint destruction in arthritis, especially in RA.


Asunto(s)
Artritis Reumatoide/metabolismo , Fibroblastos/metabolismo , Interferón gamma/fisiología , Janus Quinasa 2/antagonistas & inhibidores , Sinoviocitos/metabolismo , Adulto , Artritis Reumatoide/tratamiento farmacológico , Azetidinas/farmacología , Técnicas de Cultivo de Célula , Movimiento Celular/fisiología , Células Cultivadas , Femenino , Quinasa 1 de Adhesión Focal/fisiología , Humanos , Inhibidores de las Cinasas Janus/farmacología , Masculino , Persona de Mediana Edad , Purinas , Pirazoles , ARN Interferente Pequeño/farmacología , Sulfonamidas/farmacología
9.
Knee Surg Sports Traumatol Arthrosc ; 26(7): 2103-2109, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28508294

RESUMEN

PURPOSE: The aim of this study was to determine the reliability and validity of preoperative magnetic resonance imaging (MRI) scans for the detection of additional pathologies in patients with chronic ankle instability (CAI) compared to arthroscopic findings. METHODS: Preoperative MRI images of 30 patients were evaluated regarding articular and periarticular comorbidities and compared to intraoperative findings. The reliability of MRI was determined by calculating specificity, sensitivity, as well as positive and negative predictive values. The accuracy of the classification of cartilage lesions by Outerbridge and Berndt and Harty rating scales was determined by calculating the area under the receiver operating curve (AUC). RESULTS: In total, 72 additional pathologies were found arthroscopically compared to 73 lesions gathered from MRI images. Sensitivity ranged from 89% for peroneal tendinopathy to 28% for additional ligamentous lesions. Specificity ranged from 100% for anterolateral impingement, loose bodies and peroneal tendinopathy to 38% for additional ligamentous lesions. For cartilage lesions, sensitivity was at 91% and specificity was at 55% for the Outerbridge grading scale. For the Berndt and Harty classification system, sensitivity was at 91% and specificity was at 28%. Correlation of additional pathologies ranged from weak (r s = 0.48; p = 0.02) to moderate results (r s = 0.67; p < 0.001). CONCLUSION: CAI is associated with a high incidence of additional pathologies. In some cases, MRI delivers insufficient results, which may lead to misinterpretation of present comorbidities. MRI is a helpful tool for preoperative evaluation, but arthroscopy remains gold standard in the diagnosis of associated lesions in patients with CAI. LEVEL OF EVIDENCE: III.


Asunto(s)
Articulación del Tobillo/diagnóstico por imagen , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/cirugía , Imagen por Resonancia Magnética , Adolescente , Adulto , Anciano , Articulación del Tobillo/cirugía , Artroscopía , Enfermedad Crónica , Comorbilidad , Femenino , Humanos , Inestabilidad de la Articulación/complicaciones , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Reproducibilidad de los Resultados , Adulto Joven
10.
J Arthroplasty ; 33(1): 195-199, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28870745

RESUMEN

BACKGROUND: Information about the outcome after failed 2-stage exchange is scarce. The aim of this study is to determine possible influencing factors leading to multiple revisions, resulting in a failed endoprosthetic joint reconstruction. METHODS: Medical records of patients (15 hip and 29 knee joints) who had undergone additional revision surgeries due to a failed 2-stage exchange were reviewed concerning infection parameters, number and type of procedure(s), current state of the revised joint, and whether failure of endoprosthetic reconstruction had occurred. RESULTS: Endoprosthetic reconstruction was achieved in 52.3% (n = 23) of the patients. About 36.4% (n = 16) of patients successfully reached the second stage of the initial 2-stage exchange. Half of the patients (n = 22) had to undergo spacer exchange in the initial interstage period. Five or more revision surgeries significantly increased the odds of failure of endoprosthetic reconstruction compared to patients with <5 revision surgeries (odds ratio 4.98, 95% confidence interval 1.34-18.4, P = .016). Patients with initial culture-negative revision surgery showed no significant differences in the odds of failure of endoprosthetic reconstruction (odds ratio 0.69, 95% confidence interval 0.20-2.43, P = .567). CONCLUSION: Patients undergoing re-revision surgery due to a failed 2-stage exchange are very likely to ultimately experience a failed endoprosthetic reconstruction. The identification of the underlying pathogen does not influence the likelihood of a better outcome in terms of a successful endoprosthetic reconstruction.


Asunto(s)
Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Infecciones Relacionadas con Prótesis/microbiología , Reoperación/métodos , Estudios Retrospectivos , Insuficiencia del Tratamiento
11.
Infection ; 45(6): 885-891, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29067626

RESUMEN

PURPOSE: The aim of this study was the evaluation of possible outcome differences of patients undergoing two-stage hip exchange with antibiotic-loaded spacers, compared to patients without an interim spacer implantation. METHODS: We evaluated 46 patients undergoing two-stage hip revision surgery. Twenty-five patients received an interim ALS. Additional to a Kaplan-Meier survival analysis, a competing risk analysis was performed to estimate the cumulative incidence function for re-revisions due to infection accounting for death as a competing event. RESULTS: Nine patients (seven non-ALS vs. two ALS) had to undergo re-revision surgery due to reinfection of the hip joint. The non-ALS group showed a risk of re-revision of 19% (95% CI 5-38%) at 12 and 24 months and 30% (95% CI 12-51%) at 36 months. The group with ALS implantation displayed a 0% risk of re-revision surgery in the first 36 months. The Gray test revealed a significant difference in the cumulative incidence between both observed groups (p = 0.026). CONCLUSION: Our findings suggest that ALS implantation significantly reduces the risk of reinfection after two-stage hip revision surgery.


Asunto(s)
Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos , Gentamicinas/uso terapéutico , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Vancomicina/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos/química , Estudios de Cohortes , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Riesgo , Resultado del Tratamiento , Adulto Joven
12.
J Shoulder Elbow Surg ; 26(11): 1915-1921, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28601485

RESUMEN

BACKGROUND: Management of bacterial shoulder infections includes antibiotic therapy and surgical joint decompression. Arthroscopy and open arthrotomy are recommended treatment options. Whether 1 of the 2 surgical options is superior remains unclear. The present study aimed (1) to compare the reinfection rates after arthroscopy and open arthrotomy and (2) to identify risk factors of reinfection after surgical intervention. MATERIALS AND METHODS: The data of 59 consecutive patients were available for final analysis. All patients received arthroscopy or open arthrotomy at our institution between 2001 and 2015. The reinfection rates between the 2 distinct interventions were compared. We also evaluated the influence of potential confounders, such as age, sex, comorbidities, microbiological findings, duration of symptoms, osteoarthritis, Gächter score, and preoperative inflammatory parameters, on the recurrence of infections and compared the functional outcome between the 2 surgery groups. RESULTS: From 59 included patients, 38 (64.4%) underwent open arthrotomy, and 21 (35.6%) were treated arthroscopically. Reinfection was documented in 18 patients (30.5%). The reinfection rate was significantly higher in arthroscopically treated patients (11 [52.4%]) than in patients who underwent open arthrotomy (7 [18.4%]; P = .007). An infection with Staphylococcus aureus negatively influenced the treatment success (P = .034). CONCLUSION: According to our data, open arthrotomy is the more effective treatment method in septic arthritis of the shoulder, with lower reinfection rates and a comparable functional outcome. Furthermore, we could identify Staphylococcus aureus as an independent risk factor for the recurrence of infections.


Asunto(s)
Artritis Infecciosa/cirugía , Artroscopía , Articulación del Hombro/cirugía , Infecciones Estafilocócicas/cirugía , Anciano , Anciano de 80 o más Años , Artritis Infecciosa/microbiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Staphylococcus aureus , Resultado del Tratamiento
13.
J Arthroplasty ; 32(4): 1266-1271, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28027814

RESUMEN

BACKGROUND: Although diagnostic modalities for the detection of periprosthetic joint infection have improved, some infectious revision cases may still be diagnosed as aseptic complications. We raised the question whether patients with positive Musculoskeletal Infection Society minor infection criteria differ in their outcome parameters (revision-free survival, revision rate) when compared to patients with "true" aseptic complications. Additionally, we asked whether the indication for revision surgery (eg, loosening) might have an influence on possible outcome discrepancies. METHODS: A retrospective matched-pair analysis was performed with 98 patients who had undergone revision surgery after total joint arthroplasty. Forty-nine patients showed less than 3 positive minor criteria (PMC), whereas 49 patients without any PMC were compared regarding re-revision rate and revision-free survival. Reasons for revisions were categorized according to loosening, liner wear, implant failure, and soft-tissue complication. RESULTS: In the group of patients with PMC, 30.6% (n = 15) had to undergo re-revision compared to 6.12% (n = 3) in the true aseptic complication control group. The long-term implant survival in the PMC group was 69.4% (95% confidence interval [CI], 47-69 months) and in the aseptic control group was 93.9% (95% CI, 82-94 months; P = .001). In patients with PMC and loosening of the implant, the long-term survival was 55.2% (95% CI survival time, 28.9-53.2 months) whereas in patients without PMC and loosening, the overall survival was 96.2% (95% CI survival time, 83.5-96 months; P = .001). CONCLUSION: Our findings suggest that in the presence of prosthetic loosening, even a single positive minor criterion may have a negative impact on the outcome after total hip arthroplasty and total knee arthroplasty revision surgeries.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Falla de Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/microbiología , Estudios Retrospectivos , Resultado del Tratamiento
14.
Eur J Immunol ; 45(5): 1500-11, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25678110

RESUMEN

Secretion of type I interferon (IFN) is the first cellular reaction to invading pathogens. Despite the protective function of these cytokines, an excessive response to their action can contribute to serious pathologies, such as autoimmune diseases. Transcripts of most cytokines contain adenylate-uridylate (A/U)-rich elements (AREs) that make them highly unstable. RNA-binding proteins (RBPs) are mediators of the regulatory mechanisms that determine the fate of mRNAs containing AREs. Here, we applied an affinity proteomic approach and identified lethal, abnormal vision, drosophila-like 1 (ELAVL1)/Hu antigen R (HuR) as the predominant RBP of the IFN-ß mRNA ARE. Reduced expression or chemical inhibition of HuR severely hampered the type I IFN response in various cell lines and fibroblast-like synoviocytes isolated from joints of rheumatoid arthritis patients. These results define a role for HuR as a potent modulator of the type I IFN response. Taken together, HuR could be used as therapeutic target for diseases where type I IFN production is exaggerated.


Asunto(s)
Proteínas ELAV/inmunología , Interferón Tipo I/biosíntesis , Interferón beta/genética , Elementos Ricos en Adenilato y Uridilato , Artritis Reumatoide/genética , Artritis Reumatoide/inmunología , Secuencia de Bases , Proteínas ELAV/antagonistas & inhibidores , Proteínas ELAV/genética , Proteína 1 Similar a ELAV , Células HeLa , Humanos , Inductores de Interferón/farmacología , Datos de Secuencia Molecular , Poli I-C/farmacología , Multimerización de Proteína , Procesamiento Postranscripcional del ARN/efectos de los fármacos , Estabilidad del ARN/efectos de los fármacos , ARN Mensajero/genética , ARN Mensajero/metabolismo , ARN Interferente Pequeño/genética , Membrana Sinovial/inmunología
15.
Knee Surg Sports Traumatol Arthrosc ; 24(10): 3147-3154, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26017744

RESUMEN

PURPOSE: The aim of this study was to compare the efficacy of arthroscopy and arthrotomy in patients with septic monarthritis of the knee. METHODS: Seventy consecutive patients who underwent surgery because of a bacterial monarthritis were evaluated. Patients were either treated with arthroscopy or with arthrotomy. Our primary outcome was the early recurrence of infection (>3 months after surgery), which made a second surgical procedure necessary. Furthermore, the influence of potential confounders on treatment outcome was analysed. RESULTS: Of the 70 patients, 41 were treated arthroscopically and 29 with arthrotomy. Eight patients (11.4 %) had to undergo a second surgical procedure because of early re-infection. The rate was significantly higher in patients treated with arthrotomy (n = 6; 20.7 %) compared with those treated by arthroscopy (n = 2) (p = 0.041). Range of motion was significantly better in patients who underwent arthroscopy (p < 0.001). Male sex had negative influence on the treatment success (p = 0.03). CONCLUSIONS: Patients with bacterial monarthritis of the knee who were treated with arthroscopy had a significantly lower re-infection rate and a better functional outcome than those treated with arthrotomy. As arthroscopy is the less invasive method, it should be considered the routine treatment, according to our data. LEVEL OF EVIDENCE: Therapeutic study, Level III.


Asunto(s)
Artritis Infecciosa/terapia , Artroscopía , Articulación de la Rodilla/cirugía , Adulto , Anciano , Antibacterianos/uso terapéutico , Artritis Infecciosa/microbiología , Femenino , Humanos , Articulación de la Rodilla/microbiología , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Recurrencia , Reoperación , Estudios Retrospectivos , Factores Sexuales
16.
Int Orthop ; 39(3): 467-76, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25431215

RESUMEN

PURPOSE: First tarsometatarsal joint (TMTJ) arthrodesis is known as a powerful operative procedure to correct moderate to severe hallux valgus deformity. However, there is little evidence about actual complication rates and angular correctional power. The aims of the present study were to evaluate the (1) angular correction power and (2) complication rates of pooled data for this procedure and to perform subgroup analysis of different methods of fixation. METHODS: A systematic search for the MeSH terms "(hallux OR bunion) AND (lapidus OR TMT OR tarsometatarsal OR metatarsocuneiform) AND (fusion OR arthrodesis)" with use of the online databases MEDLINE, Embase, CINAHL, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews was conducted. RESULTS: Twenty-nine studies with a total amount of 1,470 operated feet in 1,268 patients with a mean age of 46.9 years (range, 16.5-61.9) and a mean follow-up period of 28.5 months (range, 6.0-75.6) were included. The correction of IMA averaged 9.12 degrees for screw fixation, 9.75° for staple fixation, 12.41° for combined locking plate with screw fixation, 14.36° for screw with K-wire fixation, 8.50° for pin fixation and 8.60° for external fixation (p = .0251). The overall complication rate reached 16.05 % with a nonunion rate of 4.01 %. CONCLUSION: Based on meta-analysis data, first TMTJ arthrodesis reveals higher corrective power compared to meta-analysis data on proximal, diaphyseal and distal metatarsal osteotomies.


Asunto(s)
Artrodesis/métodos , Hallux Valgus/cirugía , Articulación Metatarsofalángica/cirugía , Adolescente , Adulto , Artrodesis/efectos adversos , Placas Óseas , Tornillos Óseos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Adulto Joven
17.
Int Orthop ; 38(8): 1597-602, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24817024

RESUMEN

PURPOSE: The purpose of our study was to evaluate and quantify the bacterial adherence to the different components of total hip prosthesis. METHODS: The bacterial load of 80 retrieved hip components from 24 patients was evaluated by counting of colony-forming units (CFU) dislodged from component surfaces using the sonication culture method. RESULTS: Micro-organisms were detected in 68 of 80 explanted components. The highest bacterial load was detected on the polyethylene liners, showing a significant difference in distribution of CFU between the liner and metal components (stem and cup). Staphylococcus epidermidis was identified as the pathogen causing the highest CFU count, especially from the polyethylene liner. CONCLUSIONS: Results of our study confirm that sonicate culture of the retrieved liners and heads, which revealed the highest bacterial loads, are reliable and sufficient for pathogen detection in the clinical diagnostic routine.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Adhesión Bacteriana , Prótesis de Cadera/microbiología , Infecciones Relacionadas con Prótesis/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Técnicas de Cultivo de Célula/métodos , Recuento de Colonia Microbiana , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sonicación/métodos , Staphylococcus epidermidis/aislamiento & purificación
18.
Int Orthop ; 38(5): 983-9, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24492997

RESUMEN

PURPOSE: The proximal chevron osteotomy provides high correctional power. However, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure. This leads to insufficient weight bearing of the first ray and therefore to metatarsalgia. Recent biomechanical and clinical studies pointed out the importance of rigid fixation of proximal metatarsal osteotomies. Therefore, the aim of the present study was to compare biomechanical properties of fixation of proximal chevron osteotomies with variable locking plate and cancellous screw respectively. METHODS: Ten matched pairs of human fresh frozen cadaveric first metatarsals underwent proximal chevron osteotomy with either variable locking plate or cancellous screw fixation after obtaining bone mineral density. Biomechanical testing included repetitive plantar to dorsal loading from 0 to 31 N with the 858 Mini Bionix(®) (MTS(®) Systems Corporation, Eden Prairie, MN, USA). Dorsal angulation of the distal fragment was recorded. RESULTS: The variable locking plate construct reveals statistically superior results in terms of bending stiffness and dorsal angulation compared to the cancellous screw construct. There was a statistically significant correlation between bone mineral density and maximum tolerated load until construct failure occurred for the screw construct (r = 0.640, p = 0.406). CONCLUSION: The results of the present study indicate that variable locking plate fixation shows superior biomechanical results to cancellous screw fixation for proximal chevron osteotomy. Additionally, screw construct failure was related to levels of low bone mineral density. Based on the results of the present study we recommend variable locking plate fixation for proximal chevron osteotomy, especially in osteoporotic bone.


Asunto(s)
Placas Óseas , Tornillos Óseos , Hallux Valgus/cirugía , Huesos Metatarsianos/cirugía , Osteotomía/métodos , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Diseño de Equipo , Humanos , Persona de Mediana Edad , Osteotomía/instrumentación
19.
Pharmacol Rep ; 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758471

RESUMEN

BACKGROUND: Currently, povidone-iodine (PVP-I) and hydrogen peroxide (H2O2) are frequently used antiseptics in joint infections, but the cytotoxic effects of these solutions are already reported. N-chlorotaurine (NCT) shows a broad-spectrum bactericidal activity and is well tolerated in various tissues, but its effect on human chondrocytes is unknown. The purpose of this study was to assess the cytotoxic effect of NCT, PVP-I, and H2O2 on human chondrocytes compared to a control group in an in vitro setting to get first indications if NCT might be a promising antiseptic in the treatment of septic joint infections for the future. MATERIAL AND METHODS: Chondrocytes extracted from human cartilage were incubated with various concentrations of NCT, PVP-I, and H2O2 for 5 and 30 min respectively. EZ4U cell viability kit was used according to the manufacturer's recommendations determining cell viability. To assess cell viability based on their nuclear morphology, cells were stained with acridine-orange and identified under the fluorescence microscope. RESULTS: EZ4U kit showed after 5 and 30 min of incubation a significant decrease in cell viability at NCT 1%, NCT 0.1%, PVP-I, and H2O2, but not for NCT 0.001% and NCT 0.01%. Acridine-orange staining likewise presented a significant decrease in vital cells for all tested solutions except NCT 0.001% and NCT 0.01% after 5 and 30 min of incubation. CONCLUSION: Our results demonstrate that NCT is well tolerated by chondrocytes in vitro at the tested lower NCT concentrations 0.01% and 0.001% in contrast to the higher NCT concentrations 1% and 0.1%, PVP-I (1.1%), and H2O2 (3%), for which a significant decrease in cell viability was detected. Considering that the in vivo tolerability is usually significantly higher, our findings could be an indication that cartilage tissue in vivo would tolerate the already clinically used 1% NCT solution. In combination with the broad-spectrum bactericidal activity, NCT may be a promising antiseptic for the treatment of septic joint infections.

20.
Knee Surg Sports Traumatol Arthrosc ; 21(12): 2730-6, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22744436

RESUMEN

PURPOSE: The purpose of this study was to determine whether the floating platforms (FP) were superior to rotating platforms (RP) in computer-navigated total knee arthroplasty (TKA) comparing the range of motion (ROM) as well as clinical and subjective function of the knee. METHODS: This retrospective non-randomized single-centre cohort study includes 255 patients with a primary implanted computer-navigated e.motion™ (Aesculap B. Braun) TKA system, implanted because of clinical and radiological verified gonarthrosis. In 129 patients, the FP platform was implanted, and in 126 patients, the RP platform. As statistical procedures for differences between inlay type RP/FP in ROM and Knee Society Score (KSS) after 3- and 24-month follow-up, an analysis of covariance (with risk factors gender, age, BMI, preoperative ROM and preoperative KSS) was performed. RESULTS: Although preoperative ROM and knee society function score (KSS part II) were significantly higher in the FP group before surgery, there was no significant difference between RP and FP in ROM and KSS at 3- and 24-month follow-up. CONCLUSION: The FP platform design did not have an advantage in ROM as well as in clinical and subjective knee function compared with the RP platform in computer-navigated TKA neither in early follow-up examinations at 3 months postoperatively nor at long-time follow-up at 24 months postoperatively.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Rango del Movimiento Articular/fisiología , Cirugía Asistida por Computador , Anciano , Femenino , Humanos , Masculino , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA