1.
Comput Biol Med ; 51: 35-43, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24879392

RESUMEN

The work presented here describes the development and use of a three-dimensional thermo-dynamic model of the human eye for the prediction of temperatures and damage thresholds under irradiation. This model takes into account the blood flow by the implementation of a vectorial blood stream in the choroid and also uses the actual physiological extensions and tissue parameters of the eye. Furthermore it considers evaporation, radiation and convection at the cornea as well as the eye lid. The predicted temperatures were successfully validated against existing eye models in terms of corneal and global thermal behaviour. The model׳s predictions were additionally checked for consistency with in-vivo temperature measurements of the cornea, the irradiated retina and its damage thresholds. These thresholds were calculated from the retinal temperatures using the Arrhenius integral. Hence the model can be used to predict the temperature increase and irradiation hazard within the human eye as long as the absorption values and the Arrhenius coefficients are known and the damage mechanism is in the thermal regime.


Asunto(s)
Córnea/irrigación sanguínea , Queratomileusis por Láser In Situ , Modelos Biológicos , Retina , Termodinámica , Velocidad del Flujo Sanguíneo , Córnea/cirugía , Humanos
SELECCIÓN DE REFERENCIAS