Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Chem Pharm Bull (Tokyo) ; 65(7): 674-677, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28674341

RESUMEN

The suitability of apparatuses for the quality control of indomethacin (IND, 50 mg) compounded suppositories was evaluated and the effects of the type of suppository base on release profiles was investigated. The release characteristics of hydrophilic and lipophilic suppositories containing IND were compared using four types of dissolution methods: basket (RB), paddle (PD), dialysis tubing (DT) and flow-through cell (FTC). The release process was evaluated using the following model independent parameters: the mean dissolution time (MDT), cumulative percent of drug released (Q) at the end of the sampling time, and dissolution efficiency (DE). The fastest and most reproducible release profiles were observed for a hydrophilic base (macrogols), which resulted in more than 90% of the drug being released in 30 min using PD, RB and FTC. After 90 min, 90% of the total amount of the drug was released from a mixture of hydrophilic bases with a lipophilic base (macrogols and hard fat) in compendial dissolution methods and the mixture base was the second fastest only to the hydrophilic base. The slowest release profiles in each method were observed for the lipophilic base (hard fat). Poor drug release from any type of suppository base was noted using DT. Based on the results of the present study, FTC may be regarded as an adequate technique allowing sufficient discriminating power for the quality control of IND compounded suppositories.


Asunto(s)
Antiinflamatorios/química , Liberación de Fármacos , Indometacina/química , Supositorios , Interacciones Hidrofóbicas e Hidrofílicas , Técnicas In Vitro , Solubilidad
2.
Pharm Dev Technol ; 22(1): 130-135, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27574857

RESUMEN

The release characteristics of lipophilic suppositories containing acetaminophen (AAP) were examined using four types of dissolution methods: the basket, paddle, dialysis tubing (DT) and flow-through cell (FTC) methods. The suitability of each apparatus for quality control in AAP compounded suppositories was evaluated using statistical procedures. More than 80% of the drug was released over 60 min in all the release methods studied, with the exception of the basket method. Reproducible and faster release was achieved using the paddle method at 100 and 200 rpm, whereas poor release occurred with the basket method. The mean dissolution time (MDT), maximum dissolved quantity of AAP at the end of the sampling time (Q) and dissolution efficiency (DE) were calculated by model-independent methods. The FTC method with a single chamber used in this study was also appreciable for AAP suppositories (Q of 100%, MDT of 71-91 min and DE of 75-80%). The DT apparatus is considered similar to the FTC apparatus from a quality control perspective for judging the release properties of lipophilic base suppositories containing AAP. However, even the single chamber FTC used in this study has potential as an in vitro drug release test for suppositories. The comparative dissolution method is expected to become one of the valuable tools for selecting an adequate dissolution test.


Asunto(s)
Acetaminofén/administración & dosificación , Analgésicos no Narcóticos/administración & dosificación , Tecnología Farmacéutica/métodos , Acetaminofén/química , Analgésicos no Narcóticos/química , Liberación de Fármacos , Solubilidad , Supositorios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA