RESUMEN
BACKGROUND: This study aimed to compare outcomes of revision total knee arthroplasty (rTKA) with liner exchange (LE) versus component revision (CRev) for stiffness post-TKA. METHODS: We retrospectively identified all rTKA performed for stiffness after primary TKA using our institutional database (2003 to 2021). Cases with infection, loosening, or < two years follow-up were excluded. There were 129 rTKA included, 91 in the LE, and 38 in the CRev cohorts. The mean follow-up was 8.5 years (range, two to 21). The LE and CRev cohorts had similar baseline demographics (P > 0.05), previous manipulation (P = 0.45), time from primary TKA (P = 0.14), and pre-rTKA arc of motion (AOM) (P = 0.08). The primary outcomes were the achievement of a successful range of movement (ROM), defined as flexion ≥ 90° with an extension deficit of ≤ 10°, and AOM improvement. Kaplan-Meier analysis was used to compare survival free from re-revision between cohorts. RESULTS: For the entire cohort, 69% achieved a successful ROM, and the mean AOM improved (P < 0.001). Achievement of successful ROM was comparable between LE (72%) and CRev (62%) cohorts (P = 0.29). The mean gain in AOM was similar between LE (24.9°) and CRev (25.4°) cohorts (P = 0.45). Preoperative extension deficit was associated with poorer outcomes (P = 0.006). The 10-year re-revision-free survival was similar between the LE (86.2%) and CRev (81.1%) cohorts (P = 0.55). Survival from re-revision for stiffness at 10-years was also similar (P = 0.6). The CRev group had increased surgical times (P < 0.0001), blood loss (P < 0.0001), and length of stay (P = 0.01). CONCLUSIONS: LE resulted in similar achievement of a successful ROM and re-revision-free survival compared with CRev. In properly selected patients, LE is a reasonable option for the treatment of stiffness after TKA.
RESUMEN
BACKGROUND: There is a paucity of literature regarding the mid-term (greater than 2 years) outcomes of revision for adverse local tissue reaction to metal debris due to corrosion at the head-neck junction (trunnionosis) in metal-on-polyethylene total hip arthroplasty (THA), and risk factors for re-revision remain largely unknown. We aimed to report the re-revision-free survival and functional outcomes for this patient population and to identify risk factors for re-revision. METHODS: A total of 80 hips (79 patients) with a metal-on-polyethylene THA who had undergone revision for trunnionosis at our institution were included. The mean study follow-up from index trunnionosis revision was 4.6 years (range, 2.0 to 9.4). Kaplan-Meier survival analysis was performed with all-cause re-revision as the end point, and multivariate logistic regression was used to identify risk factors for re-revision. RESULTS: We saw that twenty-one hips (26%) underwent re-revision at a mean of 8.0 months (range, 0.03 to 36.3) after the index trunnionosis revision, most commonly for instability and infection. The two- and five-year all-cause re-revision-free survival rates were 75.0 and 73.2%, respectively. The mean Oxford Hip Score was 33.7 (range, 11 to 48); 76% were satisfied, and 24% were dissatisfied with their hip. Multivariate analysis identified not undergoing a cup revision (odds ratio: 4.5; 95% confidence interval: 1.03 to 19.7) and time from primary THA to the index trunnionosis revision (odds ratio: 0.77; 95% confidence interval: 0.62 to 0.97) as risk factors for undergoing re-revision. CONCLUSIONS: The risk of early re-revision for these patients is high (26%), mostly due to infection and instability, and functional outcomes are fair. Not performing a cup revision appears to be a risk factor for re-revision, as is the shorter time from primary THA to trunnionosis revision. LEVEL OF EVIDENCE: III.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Polietileno , Falla de Prótesis , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/efectos adversos , Reoperación/estadística & datos numéricos , Femenino , Masculino , Persona de Mediana Edad , Factores de Riesgo , Anciano , Prótesis de Cadera/efectos adversos , Corrosión , Resultado del Tratamiento , Adulto , Anciano de 80 o más Años , Estudios Retrospectivos , Diseño de Prótesis , Metales , Estudios de Seguimiento , Estimación de Kaplan-MeierRESUMEN
BACKGROUND: Porous tantalum metaphyseal cones may facilitate reconstructions of severe bone defects during revision total knee arthroplasty (TKA), but there remains a paucity of data on their outcomes at mean 5 years of follow-up. This study reports the component survivorship, patient satisfaction, functional outcomes, radiographic osseointegration, and complications of revision TKA with porous tantalum metaphyseal cones at mid-term (mean 5-year) follow-up. METHODS: This study included 152 patients who had a mean age of 66 years (range, 33 to 86 years) undergoing revision TKA with porous tantalum metaphyseal cones. Indications for surgery included aseptic loosening (n = 87, 57.3%), second-stage reimplantation for infection (n = 42, 27.6%), osteolysis with well-fixed components (n = 20, 13.2%), and periprosthetic fracture (n = 3, 2.0%). Component survivorship, clinical outcomes, radiographic outcomes, and any complications were recorded. The mean follow-up time was 5.6 years (range, 2.2 to 13.7). RESULTS: Survivorship was 100% when the end point was revision of the metaphyseal cone (no cones were revised) and 83.8% (95% confidence interval: 77.9 to 90.2%) when the end point was reoperation for any reason at 5-year follow-up. Reoperations were performed for infection (n = 10), instability (n = 4), periprosthetic fracture (n = 2), and quadriceps rupture/dehiscence (n = 3). The mean patient satisfaction score was 78.8 ± 11.3 and the mean Forgotten Joint Score was 62.2 ± 16.7 at the final follow-up. The preoperative median University of California at Los Angeles score improved from 2 (interquartile range 2 to 3) to 6 points (interquartile range 5 to 6) (P < .001), and the preoperative Oxford knee score improved from 15.2 ± 3.8 to 39.4 ± 5.1 points (P < .001) at the final follow-up. All metaphyseal cones showed radiographic evidence of osteointegration without any subsidence or loosening. CONCLUSIONS: Porous tantalum metaphyseal cones enabled robust reconstructions of severe femoral and tibial bone defects during revision TKA. These reconstructions were associated with excellent survivorship, improvements in functional outcomes, and reproducible radiographic osseointegration at mean 5-year follow-up. The most common reasons for reoperation were infection and instability.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fémur , Prótesis de la Rodilla , Oseointegración , Reoperación , Tantalio , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Anciano , Persona de Mediana Edad , Masculino , Femenino , Anciano de 80 o más Años , Estudios de Seguimiento , Fémur/cirugía , Fémur/diagnóstico por imagen , Adulto , Tibia/cirugía , Diseño de Prótesis , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Falla de Prótesis , Resultado del Tratamiento , Satisfacción del Paciente , Estudios RetrospectivosRESUMEN
BACKGROUND: Genetics play an important role in several medical domains; however, the influence of human leukocyte antigen (HLA) genotype on the development of periprosthetic joint infection (PJI) in total hip arthroplasty (THA) remains unknown. The primary aim of this study was to determine if HLA genotype is associated with the development of bacterial PJI in THA. Secondarily, we evaluated the association between HLA genotype and PJI treatment success. METHODS: A retrospective, matched, case-control study was performed using prospectively collected data from a single institution. A total of 49 patients who underwent primary THA were included, with a mean follow-up of 8.5 years (range, 4.2 to 12.9). The 23 cases (PJI) and 26 controls (no PJI) were matched for age, sex, follow-up, body mass index, primary diagnosis, and comorbidities (P > .05). High-resolution genetic analysis targeting 11 separate HLA loci was performed in all patients using serum samples. The HLA gene frequencies and carriage rates were determined and compared between cohorts. A subgroup analysis of PJI treatment success (18) and failure (5) was performed. Statistical significance was set at P = .10 for genetic analysis and at 0.05 for all other analyses. RESULTS: There were 4 HLA alleles that were significantly associated with the development of PJI. The 3 at-risk alleles included HLA-C∗06:02 (odds ratio 5.25, 95% CI [confidence interval] 0.96 to 28.6, P = .064), HLA-DQA1∗04:01 (P = .096), and HLA-DQB1∗04:02 (P = .096). The single protective allele was HLA-C∗03:04 (odds ratio 0.12, 95% CI 0.01 to 1.10, P = .052). There were no specific HLA alleles that were associated with treatment success or failure. CONCLUSIONS: This study suggests that there are at-risk and protective HLA alleles associated with the development of PJI in THA. To our knowledge, this is the first study to demonstrate an association between patient HLA genotype and the development of PJI. A larger study of the subject matter is necessary and warranted.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Genotipo , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Masculino , Femenino , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Estudios de Casos y Controles , Antígenos HLA/genética , Antígenos HLA/inmunología , Distinciones y Premios , Anciano de 80 o más Años , Adulto , Resultado del TratamientoRESUMEN
BACKGROUND: Aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) are typically described in the context of metal-on-metal (MoM) hip bearings. This study explores the diagnostic utility of preoperative serum cobalt and chromium ion levels in determining the histological grade of ALVAL in revision hip and knee arthroplasty. METHODS: This was a multicenter retrospective review of 26 hips and 13 knees assessing the correlation between preoperative ion levels (mg/L (ppb)) and the histological grade of ALVAL from intraoperative specimens. The diagnostic ability of preoperative serum cobalt and chromium levels to determine high-grade ALVAL was assessed using a receiver operating characteristic (ROC) curve. RESULTS: In the knee cohort, there was a higher serum cobalt level in high-grade ALVAL cases (10.2 mg/L (ppb) versus 3.1 mg/L (ppb)) (P = .0002). The Area Under the Curve (AUC) was 1.00 (95% confidence interval (CI) 1.00 to 1.00). There was a higher serum chromium level in high-grade ALVAL cases (12.25 mg/L (ppb) versus 7.77 mg/L (ppb)) (P = .0002). The AUC was 0.806 (95% CI 0.555 to 1.00). In the hip cohort, there was a higher serum cobalt level in high-grade ALVAL cases (333.5 mg/L (ppb) versus 119.9 mg/L (ppb)) (P = .0831). The AUC was 0.619 (95% CI 0.388 to 0.849). There was a higher serum chromium level in high-grade ALVAL cases (186.4 mg/L (ppb) versus 79.3 mg/L (ppb)) (P = .183). The AUC was 0.595 (95% CI 0.365 to 0.824). CONCLUSIONS: Histologically, high-grade ALVAL has significantly higher preoperative serum cobalt and chromium ion levels in revision TKA. Preoperative serum ion levels have excellent diagnostic utility in revision TKA. Cobalt levels in revision THA have a fair diagnostic ability and chromium levels had a poor diagnostic ability.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Vasculitis , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Metales , Cobalto , Cromo , Linfocitos , Biomarcadores , Vasculitis/diagnóstico , Vasculitis/patología , Diseño de Prótesis , Prótesis Articulares de Metal sobre Metal/efectos adversos , Falla de PrótesisRESUMEN
BACKGROUND: The purpose of this study is to assess the short-term survivorship of a new cementless total knee arthroplasty (TKA) design in comparison to its cemented predecessor design in a young patient cohort less than 65 years of age. METHODS: We performed a retrospective cohort study of all primary TKAs (cemented and cementless) in patients under the age of 65 at the time of the index procedure, in a single institution between May 2018 and May 2019. Primary outcome variables included aseptic revision and all-cause revision. Operative time was a secondary variable. Independent variables considered included age, sex, body mass index (BMI), American Society of Anesthesiologists (ASA) grade, implant type (cruciate-retaining (CR) or posterior-stabilised (PS)) and the use of cemented or cementless implants. RESULTS: There were 106 cemented TKAs and 152 cementless TKAs (Triathlon, Stryker Inc, Mahwah, NJ ) implanted. The minimum follow-up for all cases was 2 years (mean cementless 32.5 months, mean cemented 34.9 months). Of the entire 258 implants only 2 were revised. Both revisions occurred in the cemented cohort for prosthetic joint infection (PJI). The all-cause revision rate in the cementless cohort was 0% compared to 1.8% in the cemented cohort (p = 0.168). Operative times were significantly reduced from 62 min in the cemented cohort to 52.2 min in the cementless cohort (p < 0.001). CONCLUSION: In a young patient cohort, the cementless Triathlon TKA demonstrates excellent survivorship at short-term follow-up with significant reductions in operative times when compared to the cemented Triathlon TKA.
RESUMEN
BACKGROUND: Manipulation under anesthesia (MUA) is a well-established treatment for stiffness after total knee arthroplasty (TKA). Risk factors for failure of MUA remain largely unknown. The primary aim of this study was to identify risk factors for failure of MUA after TKA. METHODS: We performed a retrospective cohort study including 470 patients who underwent MUA after primary TKA with minimum 2 year follow-up. Patients were grouped into success (n = 412) or failure (n = 58) cohorts; failure was defined as flexion < 90° at most recent follow-up or revision for stiffness. The increase in flexion post-MUA for the cohort was calculated. Several clinical, patient, and surgical factors were analyzed using univariate, followed by multivariable logistic regression models to identify independent risk factors associated with failure. RESULTS: The mean increase in flexion was 42° (range 0-115). BMI 30-35 (p = 0.01, odds ratio (OR) 2.42; 95% CI 1.25-4.68) and poorer pre-MUA flexion (p < 0.01, OR 1.43; 95% CI 1.23-1.67) were risk factors for failure. When considering revision for stiffness only, BMI 30-35 (p = 0.01, OR 3.27; 95% CI 1.41-7.61), lower pre-MUA flexion (p < 0.01, OR 1.43; 95% CI 1.18-1.75), and history of prior knee surgery (p = 0.04, OR 2.31; 95% CI 1.06-5.04) were predictors of failure. Time to MUA (p = 0.48), thromboprophylaxis (p = 0.44), pre-operative opioid use (p = 0.34), depression/anxiety (p = 1.0), and several other factors analyzed were not associated with failure. CONCLUSION: In this large cohort, elevated BMI and lower pre-MUA flexion were risk factors for failure of MUA. History of prior knee surgery was an additional predictor of requiring revision for stiffness.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Insuficiencia del Tratamiento , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Factores de Riesgo , Masculino , Femenino , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Índice de Masa Corporal , Rango del Movimiento Articular , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Reoperación/estadística & datos numéricos , Complicaciones Posoperatorias/etiología , Anciano de 80 o más Años , Manipulación Ortopédica/métodosRESUMEN
BACKGROUND: Revisions of total knee arthroplasties (TKAs) may require revision of one or both tibial and femoral components. Our purpose was to examine the clinical and functional outcomes in 1- versus 2-component TKA revisions. METHODS: We identified 92 1-component (tibial or femoral) revisions at a single center. Our inclusion criteria were isolated revision of the tibial or femoral components with a minimum 2-year follow-up. The included cases were matched 1:2 with a control group of 2-component revisions (tibial and femoral) by age, body mass index, American Society of Anesthesiologists score, and indication for revision. We collected demographics, complications, operative times, any subsequent rerevisions, and functional outcome scores. RESULTS: The median follow-up time for the 1- and 2-component revision groups were 10 years (range, 3 to 17) and 8 years (range, 2 to 18), respectively. The most common complication after rerevision in both groups was stiffness at 9 of 92 (9.8%) and 9 of 170 (5.3%) in the 1- and 2-component groups, respectively (P = .20). The overall complication prevalence in the 1- and 2- component revision groups was similar 20 of 92 (22%) and 35 of 170 (21%), respectively (P = .87). Subsequent rerevisions for any indication were encountered in 12 of 92 (13.0%) of the 1-component and 18 of 170 (11%) in the 2-component groups (P = .69). There was no statistical difference in survivorship or functional outcomes scores between the groups. CONCLUSION: Our results showed that isolated revision of a single TKA component is an acceptable option, with comparable functional outcomes, complications, and survivorships when compared with both-component revision. As such, a 1-component revision should be considered where appropriate.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Falla de Prótesis , Reoperación/efectos adversos , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Modular dual mobility (MDM) acetabular components have become increasingly more popular in total hip arthroplasty (THA). Uncertainty remains regarding liner malseating and its consequences after 5 to 10 years, especially in patients who undergo revision THA. The objective of this study was to analyze the prevalence of malseating and implant survivorship of patients who underwent revision THA using an MDM liner. METHODS: We retrospectively identified patients who had a minimum 2-year follow-up and underwent revision THA using an MDM liner. Patient demographics, implant details, mortality, and all-cause revisions were recorded. Patients who had radiographic follow-up were assessed for malseating. Kaplan-Meier survival was used to determine implant survivorship. We included 143 hips in 141 patients. Mean age was 70 years (35-93 years), and 86 patients (60.1%) were female. RESULTS: Overall implant survival was 89.3% (95% confidence interval (CI) 0.843-0.946) at a mean follow-up of 6 years (ranging from 2 to 10 years). There were eight patients excluded from malseating assessment. Upon radiological review, 15 liners (11.1%) were malseated. Survival for all-cause revision for patients with malseated liners was 80.0% (12/15, 95% CI 0.62 - 0.99, P = .15) versus 91.5% in patients who had nonmalseated liners (110/120, 95% CI 0.86-0.96). There were no intraprosthetic dislocations and 3.5% of the patients were revised due to instability. No liners were revised due to malseating, and no patients who had malseated liners were revised due to instability. CONCLUSIONS: Using MDM components in our cohort comprised of revision THA was associated with a high prevalence of malseating and an overall survival of 89.3% at a mean follow-up of 6 years. Malseating does not appear to impact implant survival at a mean follow-up of 6 years.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Femenino , Anciano , Masculino , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Prevalencia , Factores de Riesgo , Diseño de Prótesis , Reoperación , Falla de PrótesisRESUMEN
BACKGROUND: The relationship between patient expectations and patient-reported outcome measures (PROMs) after total knee arthroplasty (TKA) is not well understood. The purpose of the study was to test the influence of desired knee function on postoperative perceived knee function 1 year after TKA. METHODS: A total of 102 patients undergoing primary TKA were available for data analyses. Preoperatively, patients completed the Oxford Knee Score (OKS) twice, one representing preoperative function (preoperative OKS); the second representing desired function after TKA (desired OKS). Western Ontario and McMaster Universities Arthritis Index (WOMAC), University of California, Los Angeles (UCLA) Activity score, Hospital for Special Surgery Knee Replacement Expectations Survey (HSS-KRES), Patient Health Questionnaire-9, and EuroQol-visual analogue scales were obtained preoperatively. One year after surgery, all surveys besides the UCLA activity score and HSS-KRES were repeated. The associations between postoperative OKS and WOMAC versus desired OKS and HSS-KRES were assessed using multivariable linear regression models, wherein linear regression coefficients represent the additive effect on the mean postoperative PROM. RESULTS: The desired OKS was independently associated with the postoperative OKS (linear regression coefficient = 0.43; P = .011), that is, each point increase in desired OKS yielded a 0.43 increase in postoperative OKS. The preoperative OKS showed no association with postoperative PROMs. Desired OKS was correlated with postoperative WOMAC (coefficient = -0.67; P = .014). The HSS-KRES was not associated with the postoperative OKS (coefficient = -0.005; P = .965) or WOMAC (coefficient = 0.18; P = .288). CONCLUSION: In TKA patients, higher preoperative desired function predict greater postoperative PROMs. Effects of preoperative expectations on outcomes are independent of patient demographics or preoperative function.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Estudios Prospectivos , Articulación de la Rodilla/cirugía , Periodo Posoperatorio , Encuestas y Cuestionarios , Osteoartritis de la Rodilla/cirugía , Resultado del Tratamiento , Medición de Resultados Informados por el PacienteRESUMEN
BACKGROUND: Concerns remain that thinner highly crosslinked polyethylene (HXLPE) liners in modern total hip arthroplasty (THA) may lead to premature liner-related failures or revision. The aim of this study was to evaluate the effect of liner thickness on survival and revision rates of HXLPE in primary THA after more than 10 years. METHODS: We retrospectively identified 2,565 primary THAs using HXLPE with a mean follow-up of 13 years (range, 11 to 19). Patients were grouped for each mm of polyethylene thickness. Liner thickness varied from 4.9 to 12.7 mm, with one third measuring less than 6 mm. Primary outcomes were reoperation, all-cause revision, and liner-related revision. RESULTS: The reoperation rate was 7.3%, the all-cause revision rate was 5.6%, and the liner-related revision rate was 0.04%. There was no significant difference in all-cause revision when stratified by liner thickness (P = .286) and liner thickness was not associated with liner-related revision (n = 1). There was a statistically, but not clinically significant difference in mean liner thickness for the cohort that underwent reoperation (7.09 versus 6.89 mm, P = .01) and all-cause revision (7.16 versus 6.89 mm, P = .031). CONCLUSION: In our cohort, liner thickness was not associated with all-cause revision-free survival, and there was no clinically significant difference in liner thickness between those patients who did require a reoperation or all-cause revision, and those who did not. There was only 1 liner-related failure in the entire cohort. Our results indicate that using thinner HXLPE liners to maximize femoral head size in THA is a safe practice that does not lead to increased revision rates or liner failure at a mean 13-year follow-up.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Polietileno , Estudios de Seguimiento , Estudios Retrospectivos , Falla de Prótesis , Diseño de Prótesis , ReoperaciónRESUMEN
INTRODUCTION: International joint registries provide high volumes of information in relation to the performance of total knee arthroplasty on a global scale. Distillation of this data can be challenging, particularly with the establishment of more arthroplasty registries on a yearly basis. We therefore aim to present key information from these registries in relation to primary total knee arthroplasty. The specific questions of interest include: Which fixation type is superior in TKA? Does the level of constraint impact on clinical performance? How do partial knee replacements perform in the registries? Does patellar resurfacing lead to superior results? Are there any specific implants which perform particularly well or poorly? METHODS: A comprehensive review of the major English-speaking knee arthroplasty registries across the globe was performed. Given the expanding large number of registries worldwide, it was not possible to perform a comprehensive review of all registries and so, a detailed review of the major English-speaking knee arthroplasty registries was included. Key trends and developments in implant performance were identified and presented in the current article. RESULTS: Total knee replacements have lower revision rates than both unicompartmental and patellofemoral joint replacement procedures. Patellofemoral joint replacements have the highest failure rate of all knee replacement procedures. Cruciate-Retaining (CR) TKR designs have superior outcomes to Posterior-Stabilized (PS) designs across all registries. Patellar resurfacing appears to confer an advantage over non-resurfaced patellas in primary TKR. CONCLUSION: We present current global trends in the utility and performance of TKA based on data from English-speaking arthroplasty registries.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Rótula/cirugía , Reoperación , Sistema de Registros , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugíaRESUMEN
BACKGROUND: To date, the literature has not yet revealed superiority of Minimally Invasive (MI) approaches over conventional techniques. We performed a systematic review to determine whether minimally invasive approaches are superior to conventional approaches in total hip arthroplasty for clinical and functional outcomes. We performed a meta-analysis of level 1 evidence to determine whether minimally invasive approaches are superior to conventional approaches for clinical outcomes. METHODS: All studies comparing MI approaches to conventional approaches were eligible for analysis. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were adhered to throughout this study. Registries were searched using the following MeSH terms: 'minimally invasive', 'muscle-sparing', 'THA', 'THR', 'hip arthroplasty' and 'hip replacement'. Locations searched included PubMed, the Cochrane Library, ClinicalTrials.gov, the European Union (EU) clinical trials register and the International Clinical Trials Registry Platform (World Health Organisation). RESULTS: Twenty studies were identified. There were 1,282 MI total hip arthroplasty (THAs) and 1,351 conventional THAs performed. There was no difference between MI and conventional approaches for all clinical outcomes of relevance including all-cause revision (P = .959), aseptic revision (P = .894), instability (P = .894), infection (P = .669) and periprosthetic fracture (P = .940). There was also no difference in functional outcome at early or intermediate follow-up between the two groups (P = .38). In level I studies exclusively, random-effects meta-analysis demonstrated no difference in aseptic revision (P = .461) and all other outcomes between both groups. CONCLUSION: Intermuscular MI approaches are equivalent to conventional THA approaches when considering all-cause revision, aseptic revision, infection, dislocation, fracture rates and functional outcomes. Meta-analysis of level 1 evidence supports this claim.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Sistema de Registros , ReoperaciónRESUMEN
BACKGROUND: The ability of a group of high-volume arthroplasty surgeons to simultaneously change their preferred primary total knee arthroplasty (TKA) implant of choice to another, has not been explored in the literature to date. The main hypothesis was that such a change could be made with no significant impact on clinical outcomes. METHODS: This is a retrospective cohort study comparing the last 500 consecutive TKAs implanted of a routinely used TKA implant (NexGen; Zimmer, Warsaw, IN) with the first 500 consecutive TKAs implanted of a newly adopted TKA implant (Triathlon; Stryker, Mahwah, NJ) at an institutional level. Primary outcomes of importance included all complications that occurred either intraoperatively or early postoperatively, early all-cause revision rate, and early reintervention rate. RESULTS: There was a 1.2% (n = 6) complication rate in the NexGen cohort compared to 0.8% (n = 4) in the newly adopted Triathlon cohort (P = .75). The rate of intraoperative fracture was 1% in the NexGen cohort and 0.6% in the Triathlon cohort (P = .72). The early all-cause revision rate for the NexGen TKA was 1% (n = 5) compared to 0.8% (n = 4) in the Triathlon cohort (P = 1.0). The manipulation under anesthesia (MUA) rate in the NexGen cohort was 2.4% compared to 4.6% in the Triathlon cohort (P = .058). The only predictor variable associated with MUA rate was American Society of Anesthesiologists grade, where there was a significantly lower rate of MUA with a higher American Society of Anesthesiologists grade (P = .042). CONCLUSION: It is possible to implement the institution-wide adoption of an established, high-performing TKA implant without any negative implications in relation to early revision rates, perioperative complication rates, and reintervention rates. This study is the first of its kind to be reported in the literature.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
Patient and implant selection is essential to optimize outcome. Femoral bone loss classifications such as the American Academy of Orthopaedic Surgeons, Gross, and Paprosky classifications permit surgeons to systematically manage bone stock deficiencies and guide implant selection. Here we provide a comprehensive report on the pitfalls and management of this reconstructive challenge. Preoperative planning remains vital to the treatment of femoral bone loss in revision hip arthroplasty and the authors believe it is essential and should include the entire femur. This commonly includes imaging for bone loss such as Judet views or computed tomography scan and must include the entire femur though additional radiographs such as Judet views apply more for acetabular bone loss as opposed to femoral bone loss. All patients should have pre-operative work up to exclude infection. If any of these results area elevated, an aspirate and sampling is required to guide microbiological management. Classically with regards femoral revision surgery, uncemented fixation has proven to give the best outcomes but surgeons must remain flexible and use cemented fixation when necessary. Adequate proximal bone stock permits the use of implants used in primary joint surgery. Implants with proximal modularity can be used in cases where bone stock allows for superb proximal bone support. The vast majority of femoral revisions have inadequate proximal bone stock, thus distally fixed stems should be used and have been shown to provide both axial and rotational stability provided there is an intact isthmus. Taper fluted stems can provide good outcomes even in cases of major bone loss. However, with severe bony loss, impaction grating or the use of a megaprotsthesis is sometimes necessary and is down to surgeon choice and preference. This article has been written as a guide for management and summarises the best evidence available.
RESUMEN
Background: Recent evidence on the cost-effectiveness of technology in total knee arthroplasty (TKA) demonstrated that navigated computer-assisted methods (N-TKA) is likely to be most cost-effective in the clinical setting. The aim of the current meta-analysis is to compare radiographic, clinical and functional outcomes between conventional TKA (C-TKA) and N-TKA methods. Methods: All prospective randomized controlled trials (pRCTs) comparing primary TKA performed using C-TKA and N-TKA techniques were eligible for inclusion. Radiographic outcomes included postoperative coronal, sagittal and axial component alignment. Clinical outcomes included all-cause revision and aseptic revision. Functional outcomes were analyzed when reported. A random-effects meta-analysis of all available cases was performed. This allowed for all missing data. Results: Normal coronal mechanical alignment of the tibial (p < 0.001) and femoral (p = 0.001) components was achieved more frequently with N-TKA. Normal sagittal mechanical alignment of the tibial component was achieved significantly more with N-TKA (p < 0.010). There was no difference in short-term clinical survivorship (all-cause, p = 0.649; aseptic, p = 0.79) or in functional outcomes reported between groups. There was a clinically significant reduction in the mean C-TKA operative time (87 min, σ = 16.6, 95% CI 76.4-98.8) compared N-TKA (97.6 min, σ = 16.9, 95% CI 86.2-109.1) (p = 0.17). Conclusion: Navigated TKA achieves superior radiographic alignment for femoral and tibial components in both the coronal and sagittal plane. Operative times are 10 min longer in the N-TKA group. Functional outcomes are similar between navigated and conventional groups. Clinical outcomes reported in Level I studies are limited to short-term follow-up so future prospective studies are required.
RESUMEN
Although one-stage exchange arthroplasty is gaining popularity, two-stage exchange arthroplasty remains the gold standard for the treatment of periprosthetic joint infections. Use of an articulating spacer for this procedure offers an avenue for maintaining hip motion and controlled weight-bearing, allowing local antibiotic elution. However, there is no uniform consensus on the optimal surgical protocol for using articulating spacers. This review describes the surgical technique for undertaking a first-stage exchange arthroplasty using an articulating spacer and discusses the pertinent literature on key concepts relating to periprosthetic joint infections in total hip arthroplasty to guide effective surgical decision making in these patients.
Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Reoperación/métodos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Rodilla/métodos , Resultado del Tratamiento , Estudios RetrospectivosRESUMEN
¼ The demographic profile of candidates for total knee arthroplasty (TKA) is shifting toward younger and more active individuals.¼ While cemented fixation remains the gold standard in TKA, the interest is growing in exploring cementless fixation as a potentially more durable alternative.¼ Advances in manufacturing technologies are enhancing the prospects for superior long-term biological fixation.¼ Current research indicates that intermediate to long-term outcomes of modern cementless TKA designs are comparable with traditional cemented designs.¼ The selection of appropriate patients is critical to the success of cementless fixation techniques in TKA.¼ There is a need for high-quality research to better understand the potential differences and relative benefits of cemented vs. cementless TKA systems.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla , Cementos para Huesos , Diseño de PrótesisRESUMEN
BACKGROUND: The Wagner Cone Prosthesis was designed to address complex femoral deformities during total hip arthroplasty (THA), but its mid-term component survivorship and functional outcomes remain undetermined. The objectives of this study were to determine the implant survivorship, patient satisfaction, functional outcomes, osseointegration as seen radiographically, implant subsidence, and complications of THA using the Wagner Cone Prosthesis stem at intermediate-term follow-up. METHODS: This study involved 302 patients with proximal femoral deformities, including developmental hip dysplasia and Legg-Calvé-Perthes disease, who underwent a total of 320 primary THAs using the Wagner Cone Prosthesis. The average age at the time of surgery was 49.4 ± 14.5 years (range, 18.8 to 85.6 years). Patient satisfaction was recorded using a self-administered questionnaire assessing satisfaction in 4 domains. The University of California at Los Angeles (UCLA) activity score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Oxford Hip Score (OHS), the Forgotten Joint Score (FJS), radiographic outcomes, and complications were recorded. The mean follow-up time was 10.1 years (range, 5.2 to 15.5 years). RESULTS: Survivorship of the Wagner Cone Prosthesis was 98.7% (95% confidence interval [CI]: 97.2% to 100%) with stem revision as the end point and 95.8% (95% CI: 93.5% to 98.2%) with reoperation for any reason as the end point at 10 years postoperatively. In total, 3 stems were revised: 2 for infection and 1 for chronic hip dislocation. The median patient satisfaction score was 95 (interquartile range [IQR], 80 to 100), median UCLA score was 6 (IQR, 6 to 7), median WOMAC score was 18 (IQR, 16 to 22), median OHS was 40 (IQR, 36 to 47), and median FJS was 80 (IQR, 76 to 88) at the time of final follow-up. All Wagner Cone stems that were not revised showed radiographic evidence of osseointegration, with a mean stem subsidence of 0.9 ± 0.8 mm at the most recent follow-up. CONCLUSIONS: The use of the Wagner Cone Prosthesis stem in patients with complex femoral anatomy undergoing primary THA is associated with excellent component survivorship, high levels of patient satisfaction, good functional outcomes, and reliable osseointegration with minimal stem subsidence as seen on radiographs at intermediate-term follow-up. LEVEL OF EVIDENCE: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Satisfacción del Paciente , Diseño de Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Persona de Mediana Edad , Masculino , Femenino , Adulto , Anciano , Estudios de Seguimiento , Adolescente , Anciano de 80 o más Años , Adulto Joven , Fémur/cirugía , Resultado del TratamientoRESUMEN
Aims: There are limited long-term studies reporting on outcomes of the Zimmer Modular Revision (ZMR) stem, and concerns remain regarding failure. Our primary aim was to determine long-term survival free from all-cause revision and stem-related failure for this modular revision stem in revision total hip arthroplasty (THA). Secondary aims included evaluating radiological and functional outcomes. Methods: We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR system from January 2000 to December 2007. We included 106 patients (108 hips) with a mean follow-up of 14.5 years (2.3 to 22.3). Mean patient age was 69.2 years (37.0 to 89.4), and 51.9% were female (n = 55). Indications for index revision included aseptic loosening (73.1%), infection (16.7%), fracture (9.3%), and stem fracture (0.9%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. At most recent follow-up, Oxford Hip Scores (OHS) were collected, and radiological stem stability was determined using the Engh classification. Results: A total of 17 hips (15.7%) underwent re-revision of any component. Indications for re-revision were stem failure (35.3%; n = 6), infection (29.4%; n = 5), instability (29.4%; n = 5), and acetabular aseptic loosening (5.9%; n = 1). The five- and 15-year all-cause survival was 89.7% (95% confidence interval (CI) 86.7 to 92.7) and 83.3% (95% CI 79.6 to 87.0), respectively. There were six re-revisions (5.6%) for stem failure; five for stem fracture and one for aseptic loosening. The five- and 15-year survival free from stem-related failure was 97.2% (95% CI 95.6 to 98.8) and 94.0% (95% CI 91.6 to 96.4), respectively. At final follow-up, the mean OHS was 36.9 (8.0 to 48.0) and 95.7% (n = 66) of surviving modular revision stems were well-fixed in available radiographs. Conclusion: Femoral revision with the ZMR offers satisfactory long-term all-cause revision-free survival, good survival free of stem-related failure, and favourable clinical outcomes. Stem fracture was the most common reason for stem-related failure and occurred both early and late. This highlights the importance of both early and long-term surveillance for stem-related failure.