Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Can J Anaesth ; 69(12): 1507-1514, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36198992

RESUMEN

PURPOSE: Laryngeal and tracheal injuries are known complications of endotracheal intubation. Endotracheal tubes (ETTs) with subglottic suction devices (SSDs) are commonly used in the critical care setting. There is concern that herniation of tissue into the suction port of these devices may lead to tracheal injury resulting in serious clinical consequences such as tracheal stenosis. We aimed to describe the type and location of tracheal injuries seen in intubated critically ill patients and assess injuries at the suction port as well as in-hospital complications associated with those injuries. METHODS: We conducted a prospective observational study of 57 critically ill patients admitted to a level 3 intensive care unit who were endotracheally intubated and underwent percutaneous tracheostomy. Investigators performed bronchoscopy and photographic evaluation of the airway during the percutaneous tracheostomy procedure to evaluate tracheal and laryngeal injury. RESULTS: Forty-one (72%) patients intubated with ETT with SSD and sixteen (28%) patients with standard ETT were included in the study. Forty-seven (83%) patients had a documented airway injury ranging from hyperemia to deep ulceration of the mucosa. A common tracheal injury was at the site of the tracheal cuff. Injury at the site of the subglottic suction device was seen in 5/41 (12%) patients. There were no in-hospital complications. CONCLUSIONS: Airway injury was common in critically ill patients following endotracheal intubation, and tracheal injury commonly occurred at the site of the endotracheal cuff. Injury occurred at the site of the subglottic suction port in some patients although the clinical consequences of these injuries remain unclear.


RéSUMé: OBJECTIF: Les lésions laryngées et trachéales sont des complications connues de l'intubation endotrachéale. Les sondes endotrachéales (SET) avec dispositifs d'aspiration sous-glottiques (DASG) sont couramment utilisées aux soins intensifs. On craint qu'une hernie tissulaire dans l'orifice d'aspiration de ces dispositifs n'entraîne des lésions trachéales, résultant en de graves conséquences cliniques telles qu'une sténose trachéale. Nous avons cherché à décrire le type et l'emplacement des lésions trachéales observées chez les patients gravement malades intubés et à évaluer les lésions au port d'aspiration ainsi que les complications hospitalières associées à ces lésions. MéTHODE: Nous avons mené une étude observationnelle prospective auprès de 57 patients gravement malades admis dans une unité de soins intensifs de niveau 3 qui ont été intubés par voie endotrachéale et ont subi une trachéostomie percutanée. Les chercheurs ont réalisé une bronchoscopie et une évaluation photographique des voies aériennes au cours de la trachéostomie percutanée afin d'évaluer les lésions trachéales et laryngées. RéSULTATS: Quarante et un (72 %) intubés par SET avec DASG et seize (28 %) patients avec SET standard ont été inclus dans l'étude. Quarante-sept (83 %) patients ont présenté une lésion documentée des voies aériennes allant de l'hyperémie à l'ulcération profonde de la muqueuse. Une lésion trachéale commune était localisée sur le site du ballonnet trachéal. Une lésion au site du dispositif d'aspiration sous-glottique a été observée chez 5/41 (12 %) patients. Il n'y a pas eu de complications à l'hôpital. CONCLUSION: Les lésions des voies aériennes étaient fréquentes chez les patients gravement malades après une intubation endotrachéale, et les lésions trachéales se produisaient généralement au site du ballonnet endotrachéal. Des lésions se sont produites au site de l'orifice d'aspiration sous-glottique chez certains patients, bien que les conséquences cliniques de ces lésions restent incertaines.


Asunto(s)
Enfermedad Crítica , Enfermedades de la Tráquea , Humanos , Intubación Intratraqueal/efectos adversos , Traqueostomía/métodos , Tráquea/lesiones , Succión/efectos adversos
2.
Adv Health Sci Educ Theory Pract ; 22(4): 951-968, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27787677

RESUMEN

In general, researchers attempt to quantify cognitive load using physiologic and psychometric measures. Although the construct measured by both of these metrics is thought to represent overall cognitive load, there is a paucity of studies that compares these techniques to one another. The authors compared data obtained from one physiologic tool (pupillometry) to one psychometric tool (Paas scale) to explore whether they actually measured the construct of cognitive load as purported. Thirty-two participants with a range of resuscitation medicine experience and expertise completed resuscitation-medicine based multiple-choice-questions as well as arithmetic questions. Cognitive load, as measured by both tools, was found to be higher for the more difficult questions as well as for questions that were answered incorrectly (p < 0.001). The group with the least medical experience had higher cognitive load than both the intermediate and experienced groups when answering domain-specific questions (p = 0.023 and p = 0.003 respectively for the physiologic tool; p = 0.006 and p < 0.001 respectively for the psychometric tool). There was a strong positive correlation (Spearman's ρ = 0.827, p < 0.001 for arithmetic questions; Spearman's ρ = 0.606, p < 0.001 for medical questions) between the two cognitive load measurement tools. These findings support the validity argument that both physiologic and psychometric metrics measure the construct of cognitive load.


Asunto(s)
Cognición , Médicos/psicología , Resucitación/educación , Adulto , Medidas del Movimiento Ocular , Femenino , Humanos , Masculino , Teoría Psicológica , Psicometría , Reproducibilidad de los Resultados
3.
CJEM ; 9(6): 470-3, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18072996

RESUMEN

This report describes the occurrence of pneumonitis in a young male immediately after inhalation of aerosolized chemicals subsequent to motor vehicle airbag deployment. The clinical presentation was one of mild shortness of breath associated with bilateral alveolar infiltrates on chest radiology. Not previously described, this diagnosis should be considered in the differential of pulmonary infiltrates in motor vehicle crash patients.


Asunto(s)
Airbags/efectos adversos , Neumonía/inducido químicamente , Accidentes de Tránsito , Adolescente , Corticoesteroides/uso terapéutico , Disnea/etiología , Humanos , Pulmón/diagnóstico por imagen , Masculino , Neumonía/tratamiento farmacológico , Ruidos Respiratorios/etiología , Tomografía Computarizada por Rayos X
4.
CJEM ; 4(1): 49-52, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17637149

RESUMEN

Lateral canthotomy and cantholysis is a simple procedure that can be performed by emergency physicians. It has the potential to save vision, particularly in cases of blunt ocular trauma. The case of a 37-year-old man with blunt ocular trauma, a retrobulbar hemorrhage and rapidly increasing orbital pressure requiring an urgent lateral canthotomy and cantholysis is presented. Pathophysiology, indications, contraindications, procedure and follow-up care are described.

6.
Case Rep Crit Care ; 2011: 138341, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-24826316

RESUMEN

Objective. To present a case of a healthy 41-year-old female who developed fulminant hepatic failure leading to death. The cause of hepatic failure identified on postmortem exam was herpes simplex virus hepatitis. Design. Observation of a single patient. Setting. Intensive care unit of a tertiary care university teaching hospital in Canada. Patient. 41-year-old previously healthy female presenting with a nonspecific viral illness and systemic inflammatory response syndrome. Intervention. The patient was treated with intravenous fluids and broad-spectrum antibiotics. On the second day of admission, she was found to have elevated transaminases, and, over 48 hours, she progressed to fulminant liver failure with disseminated intravascular coagulopathy, refractory lactic acidosis, and shock. She progressed to respiratory failure requiring intubation and mechanical ventilation. She was started on N-acetylcysteine, a bicarbonate infusion, hemodialysis, and multiple vasopressors and inotropes. Measurements and Main Results. Despite treatment, the patient died roughly 70 hours after her initial presentation to hospital. Her postmortem liver biopsy revealed herpes simplex virus hepatitis as her cause of death. Conclusions. Herpes simplex virus must be considered in all patients presenting with liver failure of unknown cause. If suspected, prompt treatment with acyclovir should be initiated.

7.
Can J Anaesth ; 52(4): 428-32, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15814761

RESUMEN

PURPOSE: To determine the accuracy of colorimetric CO2 detection compared to the reference standard two-step radiological confirmation of feeding tube position. METHODS: A prospective study was conducted with patients presenting to a 21-bed medical-surgical intensive care unit. An adapter was developed using an endotracheal tube adapter to connect a colorimetric CO2 detector to a feeding tube in an airtight manner. In part I of the study a feeding tube connected to the colorimeter was inserted into the endotracheal tubes of ten ventilated patients to test the device's ability to detect tracheal placement. In part II patients undergoing feeding tube insertion had tube position confirmed with the colorimeter as well as the reference standard two-step x-ray. RESULTS: In phase I the colorimeter correctly identified tracheal placement in all ten patients. In phase II 93/100 procedures ultimately were eligible; the colorimeter had a sensitivity of 0.88 (95% confidence interval: 0.65-1.00) and specificity of 0.99 (0.97-1.00). The device missed one of the eight tracheal placements. Agreement between the colorimeter and two-step x-ray interpretations was excellent (Kappa 0.86; standard error 0.10). CONCLUSION: We describe a novel, convenient method to confirm esophageal feeding tube placement. The device is easily assembled and inexpensive, but should not be reused. Colorimetric determination of tracheal feeding tube placement with this device has excellent agreement with the reference standard two-step radiological technique.


Asunto(s)
Dióxido de Carbono/análisis , Esófago , Intubación Intratraqueal/efectos adversos , Intubación/efectos adversos , Colorimetría , Humanos , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA