Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Magn Reson Imaging ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38490816

RESUMEN

BACKGROUND: Portal vein thrombosis (PVT) is thought to arise from stagnant blood flow, yet conclusive evidence is lacking. Relative residence time (RRT) assessed using 4D Flow MRI may offer insight into portal flow stagnation. PURPOSE: To explore the relationship between RRT values and the presence of PVT in cirrhotic participants. STUDY TYPE: Prospective. POPULATION: Forty-eight participants with liver cirrhosis (27 males, median age 67 years [IQR: 57-73]) and 20 healthy control participants (12 males, median age 45 years [IQR: 40-54]). FIELD STRENGTH/SEQUENCE: 3 T/4D Flow MRI. ASSESSMENT: Laboratory (liver and kidney function test results and platelet count) and clinical data (presence of tumors and other imaging findings), and portal hemodynamics derived from 4D Flow MRI (spatiotemporally averaged RRT [RRT-mean], flow velocity, and flow rate) were analyzed. STATISTICAL TESTS: We used multivariable logistic regression, adjusted by selected covariates through the Lasso method, to explore whether RRT-mean is an independent risk factor for PVT. The area under the ROC curve (AUC) was also calculated to assess the model's discriminative ability. P < 0.05 indicated statistical significance. RESULTS: The liver cirrhosis group consisted of 16 participants with PVT and 32 without PVT. Higher RRT-mean values (odds ratio [OR] 11.4 [95% CI: 2.19, 118]) and lower platelet count (OR 0.98 per 1000 µL [95% CI: 0.96, 0.99]) were independent risk factors for PVT. The incorporation of RRT-mean (AUC, 0.77) alongside platelet count (AUC, 0.75) resulted in an AUC of 0.84. When including healthy control participants, RRT-mean had an adjusted OR of 12.4 and the AUC of the combined model (RRT-mean and platelet count) was 0.90. DATA CONCLUSION: Prolonged RRT values and low platelet count were significantly associated with the presence of PVT in cirrhotic participants. RRT values derived from 4D Flow MRI may have potential clinical relevance in the management of PVT. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.

2.
Radiology ; 308(3): e230709, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37750777

RESUMEN

Background Percutaneous transhepatic portal vein (PV) embolization (PVE) is a standard preoperative procedure for advanced biliary cancer when the future liver remnant (FLR) is insufficient, yet the effect of this procedure on portal hemodynamics is still unclear. Purpose To assess whether four-dimensional (4D) MRI flowmetry can be used to estimate FLR volume and to identify the optimal time for this measurement. Materials and Methods This prospective single-center study enrolled consecutive adult patients with biliary cancer who underwent percutaneous transhepatic PVE for the right liver between June 2020 and November 2022. Portal hemodynamics were assessed using 4D flow MRI before PVE and within 1 day (0-day group) or 3-4 days (3-day group) after PVE. FLR volume was measured using CT before PVE and after PVE but before surgery. Blood flow changes were analyzed with the Wilcoxon signed rank test, and correlations with Spearman rank correlation. Results The 0-day group included 24 participants (median age, 72 years [IQR, 69-77 years]; 17 male participants), and the 3-day group included 13 participants (median age, 71 years [IQR, 68-78 years]; eight male participants). Both groups showed increased left PV (LPV) flow rate after PVE (0-day group: from median 3.72 mL/sec [IQR, 2.83-4.55 mL/sec] to 9.48 mL/sec [IQR, 8.12-10.7 mL/sec], P < .001; 3-day group: from median 3.65 mL/sec [IQR, 2.14-3.79 mL/sec] to 8.16 mL/sec [IQR, 6.82-8.98 mL/sec], P < .001). LPV flow change correlated with FLR volume change relative to the number of days from PVE to presurgery CT only in the 3-day group (ρ = 0.62, P = .02; 0-day group, P = .11). The output of the regression equation for estimating presurgery FLR volume correlated with CT-measured volume (ρ = 0.78; P = .002). Conclusion Four-dimensional flow MRI demonstrated increased blood flow in residual portal branches 3-4 days after PVE, offering insights for estimating presurgery FLR volume. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Roldán-Alzate and Oechtering in this issue.


Asunto(s)
Neoplasias del Sistema Biliar , Embolización Terapéutica , Neoplasias Hepáticas , Adulto , Humanos , Masculino , Anciano , Vena Porta/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Embolización Terapéutica/métodos , Imagen por Resonancia Magnética , Hemodinámica , Hepatectomía/métodos , Resultado del Tratamiento
3.
NMR Biomed ; : e5030, 2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37675787

RESUMEN

In the current study, we assessed changes in interstitial fluid dynamics resulting after whole-brain radiotherapy using the diffusion-weighted image analysis along the perivascular space (DWI-ALPS) method, which is a simplified variation of the diffusion tensor image ALPS (DTI-ALPS) method using diffusion-weighted imaging (DWI) with orthogonal motion-probing gradients (MPGs). This retrospective study included 47 image sets from 22 patients who underwent whole-brain radiotherapy for brain tumors. The data for the normal control group comprised 105 image sets from 105 participants with no pathological changes. DWI was performed with the three MPGs applied in an orthogonal direction to the imaging plane, and apparent diffusion coefficient images for the x-, y-, and z-axes were retrospectively generated. The ALPS index was calculated to quantify interstitial fluid dynamics. The independent t-test was used to compare the ALPS index between normal controls and patients who underwent whole-brain radiotherapy. Patients were compared in all age groups and individual age groups (20-39, 40-59, and 60-84 years). We also examined the correlation between biologically equivalent doses (BEDs) and the ALPS index, as well as the correlation between white matter hyperintensity and the ALPS index. In the comparison of all age groups, the ALPS index was significantly lower (p < 0.001) in the postradiation group (1.32 ± 0.16) than in the control group (1.44 ± 0.17), suggesting that interstitial fluid dynamics were altered in patients following whole-brain radiotherapy. Significant age group differences were found (40-59 years: p < 0.01; 60-84 years: p < 0.001), along with a weak negative correlation between BEDs (r = -0.19) and significant correlations between white matter hyperintensity and the ALPS index (r = -0.46 for periventricular white matter, r = -0.38 for deep white matter). It was concluded that the ALPS method using DWI with orthogonal MPGs suggest alteration in interstitial fluid dynamics in patients after whole-brain radiotherapy. Further systematic prospective studies are required to investigate their association with cognitive symptoms.

4.
Hepatol Res ; 51(3): 343-349, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33434371

RESUMEN

Diagnosis and severity assessments of portosystemic shunts (PSSs) are important because the pathology sometimes results in severe hepatic encephalopathy, which can be treated almost completely by shunt embolization. At present, morphological assessment of PSS is performed mainly by computed tomography, and ultrasound is used for blood flow assessment. In two cases of PSS-related hepatic encephalopathy, we used time-resolved 3D cine phase-contrast (4D-flow) magnetic resonance imaging (MRI) to assess blood flow before and after shunt embolization. Before the intervention, blood flow in the main trunk of the superior mesenteric vein was mostly hepatofugal. However, post-interventional 4D-flow MRI revealed hepatopetal superior mesenteric vein flow with significantly increased portal vein blood flow. 4D-flow MRI is an ideal adjunct to Doppler ultrasonography, allowing for objective and visual assessment of morphology and blood flow of the portal venous system, including PSSs, and is useful in determining the indications for, and outcome of, PSS embolization.

5.
Magn Reson Med Sci ; 22(1): 1-6, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34880192

RESUMEN

A man in his 50s with Budd-Chiari syndrome diagnosed with the suprahepatic inferior vena cava (IVC) obstruction on CT was assessed using 4D Flow MRI before and after balloon angioplasty. 4D Flow MRI acquired in two respiratory phases, depicted complex hemodynamic and respiratory variability, and a jet stream at the narrowed channel of the membranous IVC. Post-interventional 4D Flow MRI showed that the IVC blood flow increased with corrected flow directions in the infrarenal IVC.


Asunto(s)
Síndrome de Budd-Chiari , Masculino , Humanos , Síndrome de Budd-Chiari/diagnóstico por imagen , Síndrome de Budd-Chiari/terapia , Síndrome de Budd-Chiari/complicaciones , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/patología , Imagen por Resonancia Magnética , Hemodinámica , Resultado del Tratamiento
6.
Respirol Case Rep ; 11(11): e01232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37840601

RESUMEN

We share our experiences of instructing three patients with severe upper limb dysfunction on how to self-adjust CPAP/NPPV masks. In Case 1, we simplified the procedure by suturing a part of the headband as the left forearm was amputated. In Case 2, the patient had congenitally short limbs with short stature; thus, we provided an additional belt to the headband to maintain the headband's configuration while wearing the mask. In Case 3, the patient had left hemiplegia due to stroke and, repetitive coaching was conducted during the recovery phase rehabilitation program. Difficulties with self-adjusting NPPV/CPAP masks can occur whenever there is limited hand mobility above the head, including upper limb dysfunction. Simplifying procedures and providing sufficient time for instruction could help achieve independence. There have been no previous reports describing similar training details. We believe that sharing this knowledge will be helpful to both patients and healthcare professionals.

7.
Jpn J Radiol ; 40(9): 970-978, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35523921

RESUMEN

PURPOSE: The purpose of this study was to investigate whether the changes in apparent diffusion coefficients (ADCs) due to differences in diffusion time reflect tissue properties in actual measurements of phantoms. MATERIALS AND METHODS: Various n-alkane phantoms and sucrose/collagen phantoms with various collagen densities were set up with and without polyvinyl alcohol (PVA) foam with an average pore diameter of 300 µm. Thus, n-alkanes or sucrose/collagen represented substrate viscosity and the presence of PVA foam represented tissue structure with septum. Diffusion-weighted images with various diffusion times (7.71-60 ms) were acquired using pulsed-gradient spin-echo (PGSE) and oscillating-gradient spin-echo (OGSE) sequences. The ADCs of the phantoms with and without PVA foam were calculated. RESULTS: The ADCs of some of the phantoms without PVA decreased with diffusion times decreased. In the n-alkane phantoms, only C8H18 showed significantly different ADCs depending on the use of PVA foam in the OGSE sequence. On the other hand, sucrose/collagen phantoms showed significant differences according to diffusion time. The ADCs of the phantoms decreased as the molecular size of the n-alkanes or collagen density of the sucrose/collagen phantom increased. Compared to phantoms without PVA foam, the ADC of the phantoms with PVA foam decreased as the diffusion time increased. CONCLUSION: Changes in ADCs due to differences in diffusion time reflect tissue properties in actual measurements of phantoms. These changes in ADCs can be used for tissue characterization in vivo.


Asunto(s)
Alcanos , Imagen de Difusión por Resonancia Magnética , Difusión , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Fantasmas de Imagen , Sacarosa
8.
Jpn J Radiol ; 40(9): 894-902, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35474438

RESUMEN

PURPOSE: The purpose of this study was to evaluate the interstitial fluid status in a wide range of age groups using diffusion-weighted image analysis along the perivascular space (DWI-ALPS) method, which is a simplified variation of diffusion tensor image analysis along the perivascular space (DTI-ALPS). MATERIALS AND METHODS: This retrospective study included data from 128 patients who underwent clinical magnetic resonance imaging (MRI) studies, including DWI, and were found to have no abnormal findings in the brain on MRI. Three motion-probing gradients of the DWI were applied in an orthogonal direction to the imaging plane. Apparent diffusion coefficient images in the x-, y-, and z-axes were retrospectively generated, and composite color images were created to locate the projection and association fiber area on the slice including the body of the lateral ventricle. ALPS indices were calculated, and correlations with age were evaluated using linear and second-degree regression analysis. Linear regression analysis was also performed for a subgroup of patients older than 40 years. In addition, an analysis of variance (ANOVA) test among the generations was performed. RESULTS: The linear regression analysis between age and the ALPS index showed a correlation coefficient of -0.20 for all age group and -0.51 for the subgroup older than 40 years. The second-degree regression analysis showed a correlation coefficient of 0.39. ANOVA showed that the 40's generation showed a statistically significant higher value of ALPS index compared to all other generations except for the 30's generation. While, the 70's generation showed a statistically significant lower value of the ALPS index compared to all other generations. CONCLUSIONS: The analysis of the DWI-APLS method showed a correlation between age and the ALPS index in second-degree distribution which peaked in the 40's generation. This finding in normal subjects may be fundamental in the analysis of disease cases. We tried to evaluate the glymphatic system status in a wide range of age groups using diffusion-weighted image analysis along the perivascular space (DWI-ALPS) method, and the results showed a correlation between age and the ALPS index in second-degree distribution which peaked in the 40's generation.


Asunto(s)
Sistema Glinfático , Adulto , Imagen de Difusión por Resonancia Magnética/métodos , Líquido Extracelular/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Estudios Retrospectivos
9.
Magn Reson Med Sci ; 21(3): 401-405, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-33896892

RESUMEN

In this study, we present images acquired by a fast-imaging method for the evaluation of endolymphatic hydrops after intravenous administration of a single dose of gadolinium-based contrast agent. We utilized the hybrid of reversed image of MR cisternography and a positive perilymph signal by heavily T2- weighted 3D-fluid attenuated inversion recovery-multiplied by T2 (HYDROPS2-Mi2) method combined with deep learning reconstruction denoising. The scan time for the fast protocol was approximately 5 mins, which is far shorter than previously reported scan times. The fast acquisition provides similar image quality and less motion artifacts compared to the longer method.


Asunto(s)
Hidropesía Endolinfática , Administración Intravenosa , Medios de Contraste , Hidropesía Endolinfática/diagnóstico por imagen , Hidropesía Endolinfática/patología , Gadolinio DTPA , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Perilinfa
10.
Front Neurol ; 13: 1016577, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36408495

RESUMEN

We evaluated the inner ear distribution of 17O-labeled saline administered to the human tympanic cavity. Magnetic resonance imaging was performed after intratympanic administration in five healthy volunteers and one patient with cochlear endolymphatic hydrops. In all volunteers, 17O-labeled water permeated the cochlear basal turn and vestibule at 30 min and disappeared gradually within 2-4 h. All participants experienced positional vertigo lasting a few hours to a few days. Visualization of 17O-labeled water distribution in the endolymphatic space of the posterior ampulla showed indistinct separation of endolymph and perilymph in the cochlea and most of the vestibule in all participants. Intralabyrinthine distribution of 17O-labeled water differed from that in previous reports of intratympanically administered gadolinium-based contrast agent. 17O-labeled water in the endolymphatic space may cause heavier endolymph and positional vertigo. These results of this study may add new insights for investigating the distribution and the effects of molecules in the inner ear after the intratympanic administration in living humans.

11.
Jpn J Radiol ; 40(2): 147-158, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34390452

RESUMEN

PURPOSE: The diffusion tensor image analysis along the perivascular space (DTI-ALPS) method was developed to evaluate the brain's glymphatic function or interstitial fluid dynamics. This study aimed to evaluate the reproducibility of the DTI-ALPS method and the effect of modifications in the imaging method and data evaluation. MATERIALS AND METHODS: Seven healthy volunteers were enrolled in this study. Image acquisition was performed for this test-retest study using a fixed imaging sequence and modified imaging methods which included the placement of region of interest (ROI), imaging plane, head position, averaging, number of motion-proving gradients, echo time (TE), and a different scanner. The ALPS-index values were evaluated for the change of conditions listed above. RESULTS: This test-retest study by a fixed imaging sequence showed very high reproducibility (intraclass coefficient = 0.828) for the ALPS-index value. The bilateral ROI placement showed higher reproducibility. The number of averaging and the difference of the scanner did not influence the ALPS-index values. However, modification of the imaging plane and head position impaired reproducibility, and the number of motion-proving gradients affected the ALPS-index value. The ALPS-index values from 12-axis DTI and 3-axis diffusion-weighted image (DWI) showed good correlation (r = 0.86). Also, a shorter TE resulted in a larger value of the ALPS-index. CONCLUSION: ALPS index was robust under the fixed imaging method even when different scanners were used. ALPS index was influenced by the imaging plane, the number of motion-proving gradient axes, and TE in the imaging sequence. These factors should be uniformed in the planning ALPS method studies. The possibility to develop a 3-axis DWI-ALPS method using three axes of the motion-proving gradient was also suggested.


Asunto(s)
Imagen de Difusión Tensora , Líquido Extracelular , Imagen de Difusión por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados
12.
Magn Reson Med Sci ; 20(3): 272-279, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32830173

RESUMEN

PURPOSE: MRI of endolymphatic hydrops (EH) 4 h after intravenous administration of a single dose of gadolinium-based contrast agent is used for clinical examination in some institutions; however, further improvement in image quality would be valuable for wider clinical utility. Denoising using deep learning reconstruction (Advanced Intelligent Clear-IQ Engine [AiCE]) has been reported for CT and MR. The purpose of this study was to compare the contrast-to-noise ratio of endolymph to perilymph (CNREP) between the improved hybrid of reversed image of the positive endolymph signal and the native image of the perilymph signal multiplied with the heavily T2-weighted MR cisternography (iHYDROPS-Mi2) images, which used AiCE for the three source images (i.e. positive endolymph image [PEI], positive perilymph image [PPI], MR cisternography [MRC]) to those that did not use AiCE. We also examined if there was a difference between iHYDROPS-Mi2 images with and without AiCE for degree of visual grading of EH and in endolymphatic area [EL] ratios. METHODS: Nine patients with suspicion of EH were imaged on a 3T MR scanner. iHYDROPS images were generated by subtraction of PEI images from PPI images. iHYDROPS-Mi2 images were then generated by multiplying MRC with iHYDROPS images. The CNREP and EL ratio were measured on the iHYDROPS-Mi2 images. Degree of radiologist visual grading for EH was evaluated. RESULTS: Mean CNREP ± standard deviation was 1681.8 ± 845.2 without AiCE and 7738.6 ± 5149.2 with AiCE (P = 0.00002). There was no significant difference in EL ratio for images with and without AiCE. Radiologist grading for EH agreed completely between the 2 image types in both the cochlea and vestibule. CONCLUSION: The CNREP of iHYDROPS-Mi2 images with AiCE had more than a fourfold increase compared with that without AiCE. Use of AiCE did not adversely affect radiologist grading of EH.


Asunto(s)
Aprendizaje Profundo , Hidropesía Endolinfática , Medios de Contraste , Endolinfa , Hidropesía Endolinfática/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
13.
Magn Reson Med Sci ; 20(3): 231-235, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32788504

RESUMEN

We present a case of a patient who underwent portal vein (PV) stenting for PV stenosis after a living-donor liver transplantation. A pretreatment 3D cine phase-contrast (4D-flow) MRI showed decreased, though hepatopetal, blood flow in the PV. After stenting, 4D-flow MRI confirmed an improvement in PV flow, with a more homogeneous flow distribution to each hepatic segment. 4D-flow MRI are valuable for understanding the hemodynamics of this area, planning for treatments, and evaluating the outcome of the interventions.


Asunto(s)
Trasplante de Hígado , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/etiología , Constricción Patológica/cirugía , Humanos , Trasplante de Hígado/efectos adversos , Donadores Vivos , Imagen por Resonancia Magnética , Vena Porta/diagnóstico por imagen
14.
Magn Reson Med Sci ; 19(3): 168-175, 2020 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-31217366

RESUMEN

PURPOSE: This study aimed to evaluate comprehensively; accuracy, repeatability and reproducibility of T1 and T2 relaxation times measured by magnetic resonance fingerprinting using B1+-corrected fast imaging with steady-state precession (FISP-MRF). METHODS: The International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) phantom was scanned for 100 days, and six healthy volunteers for 5 days using a FISP-MRF prototype sequence. Accuracy was evaluated on the phantom by comparing relaxation times measured by FISP-MRF with the reference values provided by the phantom manufacturer. Daily repeatability was characterized as the coefficient of variation (CV) of the measurements over 100 days for the phantom and over 5 days for volunteers. In addition, the cross-scanner reproducibility was evaluated in volunteers. RESULTS: In the phantom study, T1 and T2 values from FISP-MRF showed a strong linear correlation with the reference values of the phantom (R2 = 0.9963 for T1; R2 = 0.9966 for T2). CVs were <1.0% for T1 values larger than 300 ms, and <3.0% for T2 values across a wide range. In the volunteer study, CVs for both T1 and T2 values were <5.0%, except for one subject. In addition, all T2 values estimated by FISP-MRF in vivo were lower than those measured with conventional mapping sequences reported in previous studies. The cross-scanner variation of T1 and T2 showed good agreement between two different scanners in the volunteers. CONCLUSION: B1+-corrected FISP-MRF showed an acceptable accuracy, repeatability and reproducibility in the phantom and volunteer studies.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Fantasmas de Imagen , Valores de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA