1.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-37952132

RESUMEN

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Asunto(s)
Anticoagulantes , Aspirina , Fibrilación Atrial , Embolia , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Aspirina/efectos adversos , Aspirina/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Canadá , Embolia/etiología , Embolia/prevención & control , Hemorragia/inducido químicamente , Piridonas/efectos adversos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Método Doble Ciego
2.
Pacing Clin Electrophysiol ; 46(8): 827-832, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37382396

RESUMEN

INTRODUCTION: Leadless pacemaker (LP) is a novel pacemaker that has been proven to be effective and safe; however, the majority of LPs in previous reports were the Medtronic Micra™ VR LP. We aim to evaluate the implant efficiency and clinical performance of the Aveir™ VR LP compared to the Micra™ VR LP. METHOD: We performed a retrospective analysis in two healthcare systems (Sparrow Hospital and Ascension Health System, Michigan) in patients implanted with LPs between January 1, 2018, and April 1, 2022. The parameters were collected at implantation, 3 months and 6 months. RESULTS: A total of 67 patients were included in the study. The Micra™ VR group had shorter time in the electrophysiology lab (41 ± 12 vs. 55 ± 11.5 min, p = .008) and shorter fluoroscopic time (6.5 ± 2.2 vs. 11.5 ± 4.5 min, p < .001) compared to the Aveir™ VR group. The Aveir™ VR group had a significantly higher implant pacing threshold compared to the Micra™ VR group (0.74 ± 0.34 mA vs. 0.5 ± 0.18 mA at pulse width 0.4 ms, p < .001), but no difference was found at 3 months and 6 months. There was no significant difference in the R-wave sensing and impedance and pacing percentage at implantation, 3 months, and 6 months. Complications of the procedure were rare. The mean projected longevity of the Aveir™ VR group was longer than the Micra™ VR group (18.8 ± 4.3 vs. 7.7 ± 0.75 years, p < .001). CONCLUSION: Implantation of the Aveir™ VR required longer laboratory and fluoroscopic time, but showed longer longevity at 6 months follow-up, compare to the Micra™ VR. Complications and lead dislodgement are rare.


Asunto(s)
Marcapaso Artificial , Realidad Virtual , Humanos , Estudios Retrospectivos , Lipopolisacáridos , Diseño de Equipo , Estimulación Cardíaca Artificial/métodos
3.
J Cardiovasc Electrophysiol ; 33(4): 741-750, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35118767

RESUMEN

BACKGROUND: Insertable cardiac monitors (ICMs) are essential for ambulatory arrhythmia diagnosis. However, definitive diagnoses still require time-consuming, manual adjudication of electrograms (EGMs). OBJECTIVE: To evaluate the clinical impact of selecting only key EGMs for review. METHODS: Retrospective analyses of randomly selected Abbott Confirm Rx™ devices with ≥90 days of remote transmission history were performed, with each EGM adjudicated as true or false positive (TP, FP). For each device, up to 3 "key EGMs" per arrhythmia type per day were prioritized for review based on ventricular rate and episode duration. The reduction in EGMs and TP days (patient-days with at least one TP EGM), and any diagnostic delay (from the first TP), were calculated versus reviewing all EGMs. RESULTS: In 1000 ICMs over a median duration of 8.1 months, at least one atrial fibrillation (AF), tachycardia, bradycardia, or pause EGM was transmitted by 424, 343, 190, and 325 devices, respectively, with a total of 95 716 EGMs. Approximately 90% of episodes were contributed by 25% of patients. Key EGM selection reduced EGM review burden by 43%, 66%, 77%, and 50% (55% overall), while reducing TP days by 0.8%, 2.1%, 0.2%, and 0.0%, respectively. Despite reviewing fewer EGMs, 99% of devices with a TP EGM were ultimately diagnosed on the same day versus reviewing all EGMs. CONCLUSION: Key EGM selection reduced the EGM review substantially with no delay-to-diagnosis in 99% of patients exhibiting true arrhythmias. Implementing these rules in the Abbott patient care network may accelerate clinical workflow without compromising diagnostic timelines.


Asunto(s)
Fibrilación Atrial , Diagnóstico Tardío , Fibrilación Atrial/diagnóstico , Bradicardia/diagnóstico , Humanos , Estudios Retrospectivos , Taquicardia/diagnóstico
4.
Heart Lung Circ ; 30(8): 1151-1156, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33781697

RESUMEN

PURPOSE: Certain patient demographics and biomarkers have been suggested to predict survival in patients infected with COVID-19. However, predictors of outcome in patients who are critically ill are unclear. MATERIALS AND METHODS: We performed a multicentre analysis of 171 consecutive patients with confirmed COVID-19 who were admitted to the intensive care unit (ICU) between 1 March 2020 and 30 April 2020 and were followed until 23 May 2020. Demographic data, past medical history, laboratory values, echocardiographic and telemetry data were analysed. Patient status was classified as either alive or deceased at hospital discharge or the end of follow-up period. RESULTS: Mean patient age was 66±13 and 57% were male. Mortality rate of this ICU cohort at the end of follow-up was 46.2%. A multivariable logistic regression analysis identified the presence or history of atrial fibrillation (Odds Ratio 4.8, p=0.004) as a significant cardiovascular attribute that contributed to increased mortality. CONCLUSION: Mortality of critically ill COVID-19 patients is high. This study suggests a relationship between atrial fibrillation and increased mortality from COVID-19. Early aggressive treatment patients with high risk characteristics, such as atrial fibrillation could improve clinical outcome.


Asunto(s)
Fibrilación Atrial/epidemiología , COVID-19/mortalidad , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad Crítica , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , SARS-CoV-2 , Tasa de Supervivencia
5.
Pacing Clin Electrophysiol ; 43(11): 1344-1350, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32969518

RESUMEN

BACKGROUND: Implantable cardiac monitors (ICMs) are increasingly used to detect arrhythmias in various clinical situations. However, the data transmission time and accuracy of detecting cardiac arrhythmias are unclear. OBJECTIVE: The objective of this study was to compare the efficiency of data transmission and arrhythmia detection accuracy of the Reveal LINQ with TruRhythm Detection with the Confirm Rx with SharpSense Technology. METHODS: In this prospective study, 142 patients were randomized 1:1 to receive Reveal LINQ or Confirm Rx ICM system. Arrhythmic events include atrial fibrillation (AF), pauses, and bradycardia. Data transmission time is defined as the time from event occurrence to physician notification. All the arrhythmic events are adjudicated for accuracy. RESULTS: A total of 3510 events were transmitted in 61 patients over 7.1 ± 3.5 months. The transmission time both for all events (448 ± 271 vs 610 ± 515 minutes, P = .02) and for patient activated triggers (24 ± 103 vs 475 ± 426 minutes, P < .0001) was significantly shorter in the Confirm Rx group. The total number of events was also higher in the Confirm Rx group (25.5 ± 45.6 vs 0.9 ± 1.1 events per patient-month, P < .01), which is likely due to event transmission setting differences between the two groups. Kaplan-Meier analysis showed that the Confirm Rx group detected true arrhythmic episodes sooner with higher percentage of diagnosed patients during 6-month follow-up (P = .006). Patient-averaged true positive detection rates were not statistically significant in the two groups (Reveal LINQ vs Confirm Rx, AF: 52% vs 38%; bradycardia: 67% vs 59%; pause: 24% vs 20%; tachycardia: 81% vs 94%). CONCLUSION: Compared to the Reveal LINQ, Confirm Rx has shorter event transmission time, more frequent event detections, shorter duration to diagnose true arrhythmic events, and higher percentage of diagnosed patients. The accuracy of arrhythmia detection in both ICMs remains suboptimal.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Prótesis e Implantes , Telemetría
6.
N Engl J Med ; 373(12): 1125-35, 2015 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-26321198

RESUMEN

BACKGROUND: Cardiac pacemakers are limited by device-related complications, notably infection and problems related to pacemaker leads. We studied a miniaturized, fully self-contained leadless pacemaker that is nonsurgically implanted in the right ventricle with the use of a catheter. METHODS: In this multicenter study, we implanted an active-fixation leadless cardiac pacemaker in patients who required permanent single-chamber ventricular pacing. The primary efficacy end point was both an acceptable pacing threshold (≤2.0 V at 0.4 msec) and an acceptable sensing amplitude (R wave ≥5.0 mV, or a value equal to or greater than the value at implantation) through 6 months. The primary safety end point was freedom from device-related serious adverse events through 6 months. In this ongoing study, the prespecified analysis of the primary end points was performed on data from the first 300 patients who completed 6 months of follow-up (primary cohort). The rates of the efficacy end point and safety end point were compared with performance goals (based on historical data) of 85% and 86%, respectively. Additional outcomes were assessed in all 526 patients who were enrolled as of June 2015 (the total cohort). RESULTS: The leadless pacemaker was successfully implanted in 504 of the 526 patients in the total cohort (95.8%). The intention-to-treat primary efficacy end point was met in 270 of the 300 patients in the primary cohort (90.0%; 95% confidence interval [CI], 86.0 to 93.2, P=0.007), and the primary safety end point was met in 280 of the 300 patients (93.3%; 95% CI, 89.9 to 95.9; P<0.001). At 6 months, device-related serious adverse events were observed in 6.7% of the patients; events included device dislodgement with percutaneous retrieval (in 1.7%), cardiac perforation (in 1.3%), and pacing-threshold elevation requiring percutaneous retrieval and device replacement (in 1.3%). CONCLUSIONS: The leadless cardiac pacemaker met prespecified pacing and sensing requirements in the large majority of patients. Device-related serious adverse events occurred in approximately 1 in 15 patients. (Funded by St. Jude Medical; LEADLESS II ClinicalTrials.gov number, NCT02030418.).


Asunto(s)
Arritmias Cardíacas/terapia , Marcapaso Artificial , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/mortalidad , Electrocardiografía Ambulatoria , Electrodos Implantados , Diseño de Equipo , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Estudios Prospectivos
7.
Eur Heart J ; 36(26): 1660-8, 2015 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-25908774

RESUMEN

AIMS: Atrial tachyarrhythmias (ATs) detected by implanted devices are often atrial fibrillation or flutter (AF) associated with stroke. We hypothesized that introduction and termination of anticoagulation based upon AT monitoring would reduce both stroke and bleeding. METHODS AND RESULTS: We randomized 2718 patients with dual-chamber and biventricular defibrillators to start and stop anticoagulation based on remote rhythm monitoring vs. usual office-based follow-up with anticoagulation determined by standard clinical criteria. The primary analysis compared the composite endpoint of stroke, systemic embolism, and major bleeding with the two strategies. The trial was stopped after 2 years median follow-up based on futility of finding a difference in primary endpoints between groups. A total of 945 patients (34.8%) developed AT, 264 meeting study anticoagulation criteria. Adjudicated atrial electrograms confirmed AF in 91%; median time to initiate anticoagulation was 3 vs. 54 days in the intervention and control groups, respectively (P < 0.001). Primary events (2.4 vs. 2.3 per 100 patient-years) did not differ between groups (HR 1.06; 95% CI 0.75-1.51; P = 0.732). Major bleeding occurred at 1.6 vs. 1.2 per 100 patient-years (HR 1.39; 95% CI 0.89-2.17; P = 0.145). In patients with AT, thromboembolism rates were 1.0 vs. 1.6 per 100 patient-years (relative risk -35.3%; 95% CI -70.8 to 35.3%; P = 0.251). Although AT burden was associated with thromboembolism, there was no temporal relationship between AT and stroke. CONCLUSION: In patients with implanted defibrillators, the strategy of early initiation and interruption of anticoagulation based on remotely detected AT did not prevent thromboembolism and bleeding. CLINICAL TRIAL REGISTRATION: IMPACT ClinicalTrials.gov identifier: NCT00559988 ( http://clinicaltrials.gov/ct2/show/NCT00559988?term=NCT00559988&rank=1 ).


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/métodos , Método Simple Ciego , Accidente Cerebrovascular/prevención & control , Telemedicina/métodos , Tromboembolia/prevención & control , Resultado del Tratamiento , Tecnología Inalámbrica
8.
Cureus ; 15(7): e41393, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37416086

RESUMEN

BACKGROUND:  Pacing-induced cardiomyopathy (PICM) is a clinical syndrome that is characterized by a drop in the left ventricular ejection fraction (LVEF) due to chronic high-burden right ventricular (RV) pacing. It has been postulated that leadless pacemakers (LPs) cause decreased risk of PICM compared to transvenous pacemakers (TVPs), but the exact risk reduction is unknown. METHODS: We performed a single-center retrospective analysis of adults who received an LP or TVP between January 1, 2014, and April 1, 2022, and had echocardiograms before and after the pacemaker implant. This study's outcomes were the RV pacing percentage, change in EF, the need for cardiac resynchronization therapy (CRT) upgrade, and follow-up duration. A Wilcoxon rank-sum test calculated the change in EF. RV time, defined as the duration from pacemaker placement to the follow-up echocardiogram in months multiplied by the RV pacing percentage, served as a surrogate for how long the RV was paced. RESULTS: A total of 614 patients were screened, and 198 patients were included in the study, where 72 received LP and 126 received TVP. The median follow-up was 480 days. The average of the reported RV percentage pacing was 63.43% for LP and 71.30% for TVP (p=0.14). The incidence of PICM and CRT upgrade was 44% and 9.7% in the LP group and 37% and 9.5% in the TVP group (p=0.3 and p>0.9), respectively. After accounting for age, sex, LP versus TVP, atrioventricular nodal ablation, RV pacing percentage, and follow-up duration, univariate analysis showed that RV time was significantly different between the two types of pacemakers (13.54 ± 14.21 months (LP) versus 9.26 ± 13.95 months (TVP), p=0.009). The difference in RV time between patients who underwent CRT upgrade and those who did not was statistically insignificant (12.11 ± 14.47 months (no CRT) versus 9.19 ± 12.00 months (CRT), p=0.5). CONCLUSIONS: This analysis demonstrated that the incidence of PICM was high in both groups (44% (LP) versus 37% (TVP)), despite significantly more RV time in patients with LP. There was no difference in CRT upgrade between LP and TVP.

9.
Europace ; 14(6): 804-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22291438

RESUMEN

AIMS: Vernakalant is a novel, relatively atrial-selective antiarrhythmic agent for conversion of atrial fibrillation (AF) to sinus rhythm. This study examined the safety and efficacy of vernakalant in converting atrial flutter (AFL) to sinus rhythm. METHODS AND RESULTS: This was a phase 2/3, randomized, double-blind, placebo-controlled trial. Adults with AFL received either a 10 min infusion of 3.0 mg/kg vernakalant (n = 39) or placebo (n = 15). If AFL or AF persisted at the end of a 15 min observation period, a second 10 min infusion of 2.0 mg/kg vernakalant or placebo was administered. The primary efficacy outcome was the proportion of patients who had treatment-induced conversion of AFL to sinus rhythm for a minimum duration of 1 min within 90 min after the start of the first infusion. No patient in the placebo group met the primary outcome. Only one patient receiving vernakalant (1 of 39, 3%) converted to sinus rhythm. A reduced mean absolute ventricular response rate occurred within 50 min in patients receiving vernakalant (mean change from baseline -8.2 b.p.m.) vs. patients receiving placebo (-0.2 b.p.m.) (P = 0.037). A post-hoc analysis revealed that vernakalant increased AFL cycle length by an average of 55 ms, whereas the AFL cycle length was unchanged in the placebo group (P < 0.001). There was no occurrence of 1 : 1 atrio-ventricular conduction. Dysgeusia and sneezing were the most common treatment-related adverse events, consistent with previous reports. CONCLUSION: Vernakalant did not restore sinus rhythm in patients with AFL. Vernakalant modestly slowed AFL and ventricular response rates, and was well tolerated.


Asunto(s)
Anisoles/administración & dosificación , Anisoles/efectos adversos , Antiarrítmicos/administración & dosificación , Antiarrítmicos/efectos adversos , Aleteo Atrial/tratamiento farmacológico , Pirrolidinas/administración & dosificación , Pirrolidinas/efectos adversos , Anciano , Anciano de 80 o más Años , Método Doble Ciego , Disgeusia/inducido químicamente , Femenino , Atrios Cardíacos/efectos de los fármacos , Sistema de Conducción Cardíaco/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Placebos , Estornudo , Resultado del Tratamiento
10.
J Interv Card Electrophysiol ; 63(3): 661-668, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34855036

RESUMEN

PURPOSE: SharpSense™ technology is an upgradable software enhancement introduced to the Abbott Confirm Rx™ insertable cardiac monitor (ICM). This study aims to characterize the real-world performance of SharpSense algorithms by comparing device detected pause and bradycardia episodes before and after the SharpSense upgrade. METHODS: Confirm Rx devices with at least 90 days monitoring each before and after SharpSense upgrade were included in the study. Bradycardia and pause detections and subcutaneous electrocardiograms (SECGs) within 90 days before and after the upgrade were extracted from Merlin.net™ patient care network for evaluation and adjudicated by expert adjudicators. RESULTS: A total of 197 devices were included in the analysis. Devices were implanted for syncope (35.0%), atrial fibrillation (32.5%), cryptogenic stroke (16.8%), and other indications including palpitations (15.7%). The SharpSense upgrade significantly reduced the number of bradycardia detections by 86.8% and pause detections by 93.1%. In adjudicated SECGs, the upgrade significantly reduced false positive (FP) bradycardia episodes by 91.5% and FP pause episodes by 82.8%. The percentage of devices with at least one FP episode was reduced from 39 to 20% for bradycardia and from 52 to 35% for pause. The number of devices with FP rate greater than 1 episode per week was reduced from 23 to 8% for bradycardia and from 39 to 20% for pause. CONCLUSIONS: In this real-world performance evaluation, the algorithms incorporated in SharpSense software upgrade in Confirm Rx ICMs substantially reduced false positive bradycardia and pause detections and the number of transmitted SECGs for clinic review.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Algoritmos , Bradicardia/diagnóstico , Humanos , Síncope
11.
J Innov Card Rhythm Manag ; 12(8): 4613-4620, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34386274

RESUMEN

While previous generations of insertable cardiac monitors (ICMs) required a bedside monitor for remote monitoring (RM), the Confirm Rx™ ICM (Abbott, Chicago, IL, USA) utilizes Bluetooth®, Wi-Fi/cellular technology, and a smart device to connect to the RM system. We aimed to characterize compliance, connectivity, and event transmission timing with the Confirm Rx™ ICM RM system. The study cohort included American patients who received the Confirm Rx™ ICM with SharpSense™ technology within three months of release (May-July 2019). Compliance with RM was quantified as the proportion of patients registering the patient app on their smart device and transmitting at least once. Connectivity was measured as the median number of days between consecutive transmissions per patient. Event transmission time was measured from episode detection to availability on the Merlin.net™ RM system (Abbott). Time from transmission until review by a clinician was examined. Values for device connectivity, episode transmission timing, and clinician view times were reported as median [first quartile, third quartile]. Of 5,666 patients who received a Confirm Rx™ ICM, 97% registered their patient app and 92% transmitted data at least once. Among those utilizing RM (aged 66 ± 15 years; 49% female), connectivity occurred every 1.5 [1.2, 2.4] days, or 4.7 times per week. Patient-reported symptoms were transmitted to Merlin.net™ within 2.9 [2.1, 3.8] minutes of event onset and viewed by the clinician within 0.9 [0.4, 3.1] days, while device-detected episodes without symptoms were transmitted within 18.5 [11.2, 36.5] hours and then viewed within 0.8 [0.3, 2.5] days. This real-world study demonstrated excellent patient compliance with the smartphone-based RM paradigm enabled by Confirm Rx™, suggesting the suitability of this technology for future cardiac implantable devices.

12.
J Cardiovasc Electrophysiol ; 21(12): 1349-54, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20561107

RESUMEN

OBJECTIVES: the PROVE trial was designed to determine if antitachycardia pacing (ATP) is clinically beneficial for primary prevention in patients who have implantable cardioverter defibrillators (ICDs) or cardiac resynchronization therapy defibrillators (CRT-Ds). BACKGROUND: use of ICDs and CRT-Ds reduces mortality in patients with ventricular dysfunction and mild to moderate heart failure. However, in studies of the primary prevention population, shock-only ICDs are predominantly used, without ATP programming for less painful termination of ventricular tachycardia (VT). METHODS: we conducted a prospective, nonrandomized, multicenter study using market-released ICDs and CRT-Ds. Patients received devices programmed to deliver ATP for VT cycle lengths of 270-330 ms. Follow-up evaluation was performed at 3, 6, and 12 months. The incidence of VT and the rate of successful termination by ATP were analyzed. RESULTS: of 830 patients in the study population (men, 73%; mean age, 67.3 ± 12 years), 32% received single-chamber ICDs, 44% dual-chamber ICDs, and 24% CRT-Ds. ATP was attempted for 112 VT episodes in 71 patients, and 103 (92%) of the VT episodes were successfully terminated. Three VT episodes were accelerated by ATP and required termination by ICD shock; 6 episodes terminated spontaneously or by ICD shock. CONCLUSIONS: VT is common in patients without a history of this arrhythmia who have received ICDs or CRT-Ds for primary prevention indications. Programming ICDs for ATP therapy at the time of implantation could potentially terminate most VT episodes and reduce the number of painful shocks for these patients.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Desfibriladores Implantables , Prevención Primaria/métodos , Taquicardia Ventricular/prevención & control , Anciano , Estimulación Cardíaca Artificial/efectos adversos , Estudios de Cohortes , Desfibriladores Implantables/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/fisiopatología
13.
Circulation ; 118(20): 2022-8, 2008 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-18955671

RESUMEN

BACKGROUND: Sudden cardiac death remains a leading cause of mortality despite advances in medical treatment for the prevention of ischemic heart disease and heart failure. Recent studies showed a benefit of implantable cardioverter defibrillator implantation, but appropriate shocks for ventricular tachyarrhythmias were noted only in a minority of patients during 4 to 5 years of follow-up. Accordingly, better risk stratification is needed to optimize patient selection. In this regard, microvolt T-wave alternans (TWA) has emerged as a potentially useful measure of arrhythmia vulnerability, but it has not been evaluated previously in a prospective, randomized trial of implantable cardioverter defibrillator therapy. METHODS AND RESULTS: This investigation was a prospective substudy of the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) that included 490 patients at 37 clinical sites. TWA tests were classified by blinded readers as positive (37%), negative (22%), or indeterminate (41%) by standard criteria. The composite primary end point was the first occurrence of any of the following events: sudden cardiac death, sustained ventricular tachycardia/fibrillation, or appropriate implantable cardioverter defibrillator discharge. During a median follow-up of 30 months, no significant differences in event rates were found between TWA-positive or -negative patients (hazard ratio 1.24, 95% confidence interval 0.60 to 2.59, P=0.56) or TWA-negative and nonnegative (positive and indeterminate) subjects (hazard ratio 1.28, 95% confidence interval 0.65 to 2.53, P=0.46). Similar results were obtained with the inclusion or exclusion of patients randomized to amiodarone in the analyses. CONCLUSIONS: TWA testing did not predict arrhythmic events or mortality in SCD-HeFT, although a small reduction in events (20% to 25%) among TWA-negative patients cannot be excluded given the sample size of this study. Accordingly, these results suggest that TWA is not useful as an aid in clinical decision making on implantable cardioverter defibrillator therapy among patients with heart failure and left ventricular systolic dysfunction.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Insuficiencia Cardíaca/complicaciones , Disfunción Ventricular/complicaciones , Anciano , Arritmias Cardíacas/terapia , Desfibriladores Implantables , Susceptibilidad a Enfermedades , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Medición de Riesgo , Método Simple Ciego , Sístole
14.
Circulation ; 117(12): 1518-25, 2008 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-18332267

RESUMEN

BACKGROUND: The present study assessed the efficacy and safety of vernakalant hydrochloride (RSD1235), a novel compound, for the conversion of atrial fibrillation (AF). METHODS AND RESULTS: Patients were randomized in a 2:1 ratio to receive vernakalant or placebo and were stratified by AF duration of 3 hours to 7 days (short duration) and 8 to 45 days (long duration). A first infusion of placebo or vernakalant (3 mg/kg) was given for 10 minutes, followed by a second infusion of placebo or vernakalant (2 mg/kg) 15 minutes later if AF was not terminated. The primary end point was conversion of AF to sinus rhythm for at least 1 minute within 90 minutes of the start of drug infusion in the short-duration AF group. A total of 336 patients were randomized and received treatment (short duration, n=220; long duration, n=116). Of the 145 vernakalant patients, 75 (51.7%) in the short-duration AF group converted to sinus rhythm (median time, 11 minutes) compared with 3 of the 75 placebo patients (4.0%; P<0.001). Overall, in the short- and long-duration AF groups, 83 of the 221 vernakalant patients (37.6%) experienced termination of AF compared with 3 of the 115 placebo patients (2.6%; P<0.001). Transient dysgeusia and sneezing were the most common side effects in vernakalant-treated patients. Four vernakalant-related serious adverse events (hypotension [2 events], complete atrioventricular block, and cardiogenic shock) occurred in 3 patients. CONCLUSIONS: Vernakalant demonstrated rapid conversion of short-duration AF and was well tolerated.


Asunto(s)
Anisoles/administración & dosificación , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Pirrolidinas/administración & dosificación , Anciano , Anisoles/efectos adversos , Antiarrítmicos/efectos adversos , Fibrilación Atrial/complicaciones , Canadá , Método Doble Ciego , Disgeusia/inducido químicamente , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placebos , Pirrolidinas/efectos adversos , Países Escandinavos y Nórdicos , Estornudo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
15.
Am Heart J ; 158(3): 364-370.e1, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19699858

RESUMEN

Atrial fibrillation and atrial flutter are common cardiac arrhythmias associated with an increased risk of stroke in patients with additional risk factors. Anticoagulation ameliorates stroke risk, but because these arrhythmias may occur intermittently without symptoms, initiation of prophylactic therapy is often delayed until electrocardiographic documentation is obtained. The IMPACT study is a multicenter, randomized trial of remote surveillance technology in patients with implanted dual-chamber cardiac resynchronization therapy defibrillator (CRT-D) devices designed to test the hypothesis that initiation and withdrawal of oral anticoagulant therapy guided by continuous ambulatory monitoring of the atrial electrogram improve clinical outcomes by reducing the combined rate of stroke, systemic embolism, and major bleeding compared with conventional clinical management. For those in the intervention group, early detection of atrial high-rate episodes (AHRE) generates an automatic alert to initiate anticoagulation based on patient-specific stroke risk stratification. Subsequently, freedom from AHRE for predefined periods prompts withdrawal of anticoagulation to avoid bleeding. Patients in the control arm are managed conventionally, the anticoagulation decision prompted by incidental detection of atrial fibrillation or atrial flutter during routine clinical follow-up. The results will help define the clinical utility of wireless remote cardiac rhythm surveillance and help establish the critical threshold of AHRE burden warranting anticoagulant therapy in patients at risk of stroke. In this report, we describe the study design and baseline demographic and clinical features of the initial cohort (227 patients).


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/terapia , Aleteo Atrial/terapia , Estimulación Cardíaca Artificial , Desfibriladores Implantables , Electrocardiografía , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Aleteo Atrial/complicaciones , Aleteo Atrial/diagnóstico , Estudios de Cohortes , Electrocardiografía/métodos , Embolia/etiología , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Proyectos de Investigación , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Telemetría
16.
N Engl J Med ; 352(3): 225-37, 2005 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-15659722

RESUMEN

BACKGROUND: Sudden death from cardiac causes remains a leading cause of death among patients with congestive heart failure (CHF). Treatment with amiodarone or an implantable cardioverter-defibrillator (ICD) has been proposed to improve the prognosis in such patients. METHODS: We randomly assigned 2521 patients with New York Heart Association (NYHA) class II or III CHF and a left ventricular ejection fraction (LVEF) of 35 percent or less to conventional therapy for CHF plus placebo (847 patients), conventional therapy plus amiodarone (845 patients), or conventional therapy plus a conservatively programmed, shock-only, single-lead ICD (829 patients). Placebo and amiodarone were administered in a double-blind fashion. The primary end point was death from any cause. RESULTS: The median LVEF in patients was 25 percent; 70 percent were in NYHA class II, and 30 percent were in class III CHF. The cause of CHF was ischemic in 52 percent and nonischemic in 48 percent. The median follow-up was 45.5 months. There were 244 deaths (29 percent) in the placebo group, 240 (28 percent) in the amiodarone group, and 182 (22 percent) in the ICD group. As compared with placebo, amiodarone was associated with a similar risk of death (hazard ratio, 1.06; 97.5 percent confidence interval, 0.86 to 1.30; P=0.53) and ICD therapy was associated with a decreased risk of death of 23 percent (0.77; 97.5 percent confidence interval, 0.62 to 0.96; P=0.007) and an absolute decrease in mortality of 7.2 percentage points after five years in the overall population. Results did not vary according to either ischemic or nonischemic causes of CHF, but they did vary according to the NYHA class. CONCLUSIONS: In patients with NYHA class II or III CHF and LVEF of 35 percent or less, amiodarone has no favorable effect on survival, whereas single-lead, shock-only ICD therapy reduces overall mortality by 23 percent.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Anciano , Causas de Muerte , Estudios Cruzados , Femenino , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Riesgo , Volumen Sistólico , Análisis de Supervivencia
17.
J Interv Card Electrophysiol ; 53(2): 239-247, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30105428

RESUMEN

PURPOSE: Use of novel medical technologies, such as leadless pacemaker (LP) therapy, may be subjected to a learning curve effect. The objective of the current study was to assess the impact of operators' experience on the occurrence of serious adverse device effects (SADE) and procedural efficiency. METHODS: Patients implanted with a Nanostim LP (Abbott, USA) within two prospective studies (i.e., LEADLESS ll IDE and Leadless Observational Study) were assessed. Patients were categorized into quartiles based on operator experience. Learning curve analysis included the comparison of SADE rates at 30 days post-implant per quartile and between patients in quartile 4 (> 10 implants) and patients in quartiles 1 through 3 (1-10 implants). Procedural efficiency was assessed based on procedure duration and repositioning attempts. RESULTS: Nanostim LP implant was performed in 1439 patients by 171 implanters at 60 centers in 10 countries. A total of 91 (6.4%) patients experienced a SADE in the first 30 days. SADE rates dropped from 7.4 to 4.5% (p = 0.038) after more than 10 implants per operator. Total procedure duration decreased from 30.9 ± 19.1 min in quartile 1 to 21.6 ± 13.2 min (p < 0.001) in quartile 4. The need for multiple repositionings during the LP procedure reduced in quartile 4 (14.8%), compared to quartiles 1 (26.8%; p < 0.001), 2 (26.6%; p < 0.001), and 3 (20.4%; p = 0.03). CONCLUSIONS: Learning curves exist for Nanostim LP implantation. Procedure efficiency improved with increased operator experience, according to a decrease in the incidence of SADE, procedure duration, and repositioning attempts.


Asunto(s)
Arritmias Cardíacas/terapia , Electrofisiología Cardíaca/educación , Diseño de Equipo , Curva de Aprendizaje , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico por imagen , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Electrodos Implantados , Femenino , Humanos , Internacionalidad , Modelos Logísticos , Masculino , Monitoreo Fisiológico/métodos , Análisis Multivariante , Pronóstico , Estudios Prospectivos , Análisis y Desempeño de Tareas , Factores de Tiempo
18.
Heart Rhythm ; 15(7): 1023-1030, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29957188

RESUMEN

BACKGROUND: Leadless cardiac pacemakers (LCPs) aim to mitigate lead- and pocket-related complications seen with transvenous pacemakers (TVPs). OBJECTIVE: The purpose of this study was to compare complications between the LCP cohort from the LEADLESS Pacemaker IDE Study (Leadless II) trial and a propensity score-matched real-world TVP cohort. METHODS: The multicenter LEADLESS II trial evaluated the safety and efficacy of the Nanostim LCP (Abbott, Abbott Park, IL) using structured follow-up, with serious adverse device effects independently adjudicated. TVP data were obtained from Truven Health MarketScan claims databases for patients implanted with single-chamber TVPs between April 1, 2010 and March 31, 2014 and more than 1 year of preimplant enrollment data. Comorbidities and complications were identified via International Classification of Diseases, Ninth Revision and Current Procedural Terminology codes. Short-term (≤1 months) and mid-term (>1-18 months) complications were compared between the LCP cohort and a propensity score-matched subset of the TVP cohort. RESULTS: Among 718 patients with LCPs (mean age 75.6 ± 11.9 years; 62% men) and 1436 patients with TVPs (mean age 76.1 ± 12.3 years; 63% men), patients with LCPs experienced fewer complications (hazard ratio 0.44; 95% confidence interval 0.32-0.60; P < .001), including short-term (5.8% vs 9.4%; P = .01) and mid-term (0.56% vs 4.9%; P < .001) events. In the short-term time frame, patients with LCPs had more pericardial effusions (1.53% vs 0.35%; P = .005); similar rates of vascular events (1.11% vs 0.42%; P = .085), dislodgments (0.97% vs 1.39%; P = .54), and generator complications (0.70% vs 0.28%; P = .17); and no thoracic trauma compared to patients with TVPs (rate of thoracic trauma 3.27%). In short- and mid-term time frames, TVP events absent from the LCP group included lead-related, pocket-related, and infectious complications. CONCLUSION: Patients with LCPs experienced fewer overall short- and mid-term complications, including infectious and lead- and pocket-related events, but more pericardial effusions, which were uncommon but serious.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Cateterismo Venoso Central , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/etiología , Puntaje de Propensión , Anciano , Arritmias Cardíacas/fisiopatología , Diseño de Equipo , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Derrame Pericárdico/diagnóstico , Pronóstico , Estudios Retrospectivos , Factores de Tiempo
19.
Am Heart J ; 153(4): 573-8, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17383296

RESUMEN

BACKGROUND: Recent observations suggest statin treatment may be associated with lower mortality in heart failure (HF). The SCD-HeFT was a study of 2521 functional class II and III HF patients with left ventricular ejection fractions < or = 35% and ischemic and nonischemic cardiomyopathy followed up for a median of 45.5 months. The study length, size, and degree of background HF, including the use of implantable defibrillator therapy, provide a unique opportunity to evaluate the impact of statin use in HF with mechanistic insights from subgroup analyses. METHODS AND RESULTS: Statin use was reported in 965 (38%) of 2521 patients at baseline and 1187 (47%) at last follow-up. The relationships between statin use, randomization arm, disease category, and functional class and all cause mortality were assessed. Statin use was studied as a time-dependent covariate in a multivariable Cox proportional hazards model, adjusted for imbalances between statin and no-statin groups. Mortality risk was significantly lower in those taking a statin (HR [95% CI], 0.70 [0.58-0.83]). Mortality risk was lower with statin use in all prespecified subgroups: ischemic cardiomyopathy (0.69 [0.56-0.86]), nonischemic cardiomyopathy (0.67 [0.47-0.96]), implantable cardioverter defibrillator (ICD) (0.66 [0.46-0.95], non-ICD (0.71 [0.57-0.87]), New York Heart Association II (0.62 [0.48-0.79]), and New York Heart Association III (0.79 [0.61-1.03]). CONCLUSIONS: Statin use is associated with reduced all-cause mortality in HF patients. Statins appear to benefit patients with nonischemic and ischemic cardiomyopathy similarly. Statin benefits are similar in ICD and non-ICD patients.


Asunto(s)
Cardiomiopatías/mortalidad , Cardiomiopatías/terapia , Desfibriladores Implantables , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/terapia , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
20.
J Interv Card Electrophysiol ; 19(1): 55-60, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17605095

RESUMEN

BACKGROUND: Atrial overdrive pacing algorithms may be effective in preventing or suppressing atrial fibrillation (AF). However, the maintenance of a heart rate incessantly faster than spontaneous could induce left ventricular (LV) dysfunction and promote heart failure (HF) on the long term. OBJECTIVE: This post hoc analysis examined the effects of a new overdrive algorithm on the incidence of HF-related adverse events in 411 patients enrolled in the ADOPT-A trial. MATERIALS AND METHODS: The AF Suppression algorithm was randomly programmed ON in 209 patients (treatment group) versus OFF in 202 patients (control group). The incidence of HF-related adverse events and HF-related deaths over a 6-month follow-up was compared between the two groups. Patients with versus without HF-related clinical events were also compared to each other within each group. RESULTS: There were eight HF-related adverse clinical events (3.8%) in the treatment group and 11 (5.4%) in the control group, including four HF-related deaths (1.9 vs. 2.0%) in each group during follow-up. Baseline NYHA functional class in patients with versus without HF-related adverse events was 1.4 +/- 0.5 versus 1.5 +/- 0.7 in the control, and 1.5 +/- 0.8 versus 1.5 +/- 0.6 in the treatment group. LV ejection fraction (EF) was 49 +/- 7% in patients with, versus 57 +/- 12% in patients without HF-related adverse events, in the control group, and 43 +/- 14% in patients with, versus 56 +/- 13% in patients without HF-related adverse events, in the treatment group. LVEF was lowest and similar in both groups among patients who died from HF (35 +/- 10% in the control and 38 +/- 27% in the treatment group). CONCLUSIONS: In ADOPT-A, HF-related clinical events and deaths were related to LV dysfunction and not to atrial pacing overdriven by the AF suppression algorithm.


Asunto(s)
Fibrilación Atrial/terapia , Gasto Cardíaco Bajo/epidemiología , Marcapaso Artificial , Anciano , Algoritmos , Estimulación Cardíaca Artificial , Femenino , Humanos , Incidencia , Masculino , Prevalencia , Método Simple Ciego , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA