Arch Kriminol ; 235(1-2): 22-8, 2015.
Artículo en Alemán | MEDLINE | ID: mdl-26419089

RESUMEN

Despite wearing high-impedance shoes, a young male died while trying to connect a garden pump (230 V). The cause of death could easily be determined on the basis of testimonies of eye-witnesses and an electric mark on the body. Histological and electron microscopic examinations showed metallisation of the electric mark (pure iron). Intensive investigative efforts were needed, however, to reproduce the current path, which resulted from three different coactive failures. The electrotechnical characteristics of the case and the resulting current path are described.


Asunto(s)
Traumatismos por Electricidad/patología , Equipos y Suministros Eléctricos/efectos adversos , Análisis de Falla de Equipo , Testimonio de Experto/legislación & jurisprudencia , Adulto , Autopsia , Quemaduras por Electricidad/patología , Impedancia Eléctrica , Traumatismos de la Mano/patología , Humanos , Masculino , Microscopía Electrónica , Piel/lesiones , Piel/patología