1.
Magn Reson Med ; 91(5): 1951-1964, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38181169

RESUMEN

PURPOSE: Simultaneous PET-MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis-registration between free-breathing 3D PET and 2D breath-held MR images. We propose a free-breathing non-rigid motion-compensated 3D T2 -mapping sequence enabling whole-heart myocardial tissue characterization in a hybrid 3T PET-MR system and provides non-rigid respiratory motion fields to correct also simultaneously acquired PET data. METHODS: Free-breathing 3D whole-heart T2 -mapping was implemented on a hybrid 3T PET-MRI system. Three datasets were acquired with different T2 -preparation modules (0, 28, 55 ms) using 3-fold undersampled variable-density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi-contrast non-rigid motion-corrected MR reconstruction. T2 -maps were computed using dictionary-matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET-MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T2 -mapping (in-vivo). RESULTS: Phantom results show a high correlation (R2 = 0.996) between proposed approach and gold standard 2D T2 mapping. In-vivo 3D T2 -mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T2 -mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland-Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of -2.4-6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of -1.9 to 4.6 ms for patients. CONCLUSION: Validated efficient 3D whole-heart T2 -mapping at hybrid 3T PET-MRI provides myocardial inflammation characterization and non-rigid respiratory motion fields for simultaneous PET data correction. Comparable T2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR-based motion correction.


Asunto(s)
Miocarditis , Miocardio , Humanos , Imagen por Resonancia Magnética , Movimiento (Física) , Imagenología Tridimensional/métodos , Tomografía de Emisión de Positrones , Corazón/diagnóstico por imagen , Fantasmas de Imagen
2.
Circulation ; 145(25): 1811-1824, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35621277

RESUMEN

BACKGROUND: Endomyocardial biopsy (EMB) is the gold standard method for surveillance of acute cardiac allograft rejection (ACAR) despite its invasive nature. Cardiovascular magnetic resonance (CMR)-based myocardial tissue characterization allows detection of myocarditis. The feasibility of CMR-based surveillance for ACAR-induced myocarditis in the first year after heart transplantation is currently undescribed. METHODS: CMR-based multiparametric mapping was initially assessed in a prospective cross-sectional fashion to establish agreement between CMR- and EMB-based ACAR and to determine CMR cutoff values between rejection grades. A prospective randomized noninferiority pilot study was then undertaken in adult orthotopic heart transplant recipients who were randomized at 4 weeks after orthotopic heart transplantation to either CMR- or EMB-based rejection surveillance. Clinical end points were assessed at 52 weeks. RESULTS: Four hundred one CMR studies and 354 EMB procedures were performed in 106 participants. Forty heart transplant recipients were randomized. CMR-based multiparametric assessment was highly reproducible and reliable at detecting ACAR (area under the curve, 0.92; sensitivity, 93%; specificity, 92%; negative predictive value, 99%) with greater specificity and negative predictive value than either T1 or T2 parametric CMR mapping alone. High-grade rejection occurred in similar numbers of patients in each randomized group (CMR, n=7; EMB, n=8; P=0.74). Despite similarities in immunosuppression requirements, kidney function, and mortality between groups, the rates of hospitalization (9 of 20 [45%] versus 18 of 20 [90%]; odds ratio, 0.091; P=0.006) and infection (7 of 20 [35%] versus 14 of 20 [70%]; odds ratio, 0.192; P=0,019) were lower in the CMR group. On 15 occasions (6%), patients who were randomized to the CMR arm underwent EMB for clarification or logistic reasons, representing a 94% reduction in the requirement for EMB-based surveillance. CONCLUSIONS: A noninvasive CMR-based surveillance strategy for ACAR in the first year after orthotopic heart transplantation is feasible compared with EMB-based surveillance. REGISTRATION: HREC/13/SVH/66 and HREC/17/SVH/80. AUSTRALIAN NEW ZEALAND CLINICAL TRIALS REGISTRY: ACTRN12618000672257.


Asunto(s)
Trasplante de Corazón , Miocarditis , Adulto , Australia/epidemiología , Biopsia/métodos , Estudios Transversales , Rechazo de Injerto/diagnóstico , Trasplante de Corazón/efectos adversos , Humanos , Espectroscopía de Resonancia Magnética , Miocarditis/diagnóstico , Miocardio/patología , Proyectos Piloto , Estudios Prospectivos
3.
J Magn Reson Imaging ; 58(4): 1110-1122, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36757267

RESUMEN

BACKGROUND: Bright-blood lumen and black-blood vessel wall imaging are required for the comprehensive assessment of aortic disease. These images are usually acquired separately, resulting in long examinations and potential misregistration between images. PURPOSE: To characterize the performance of an accelerated and respiratory motion-compensated three-dimensional (3D) cardiac MRI technique for simultaneous contrast-free aortic lumen and vessel wall imaging with an interleaved T2 and inversion recovery prepared sequence (iT2Prep-BOOST). STUDY TYPE: Prospective. POPULATION: A total of 30 consecutive patients with aortopathy referred for a clinically indicated cardiac MRI examination (9 females, mean age ± standard deviation: 32 ± 12 years). FIELD STRENGTH/SEQUENCE: 1.5-T; bright-blood MR angiography (diaphragmatic navigator-gated T2-prepared 3D balanced steady-state free precession [bSSFP], T2Prep-bSSFP), breath-held black-blood two-dimensional (2D) half acquisition single-shot turbo spin echo (HASTE), and 3D bSSFP iT2Prep-BOOST. ASSESSMENT: iT2Prep-BOOST bright-blood images were compared to T2prep-bSSFP images in terms of aortic vessel dimensions, lumen-to-myocardium contrast ratio (CR), and image quality (diagnostic confidence, vessel sharpness and presence of artifacts, assessed by three cardiologists on a 4-point scale, 1: nondiagnostic to 4: excellent). The iT2Prep-BOOST black-blood images were compared to 2D HASTE images for quantification of wall thickness. A visual comparison between computed tomography (CT) and iT2Prep-BOOST was performed in a patient with chronic aortic dissection. STATISTICAL TESTS: Paired t-tests, Wilcoxon signed-rank tests, intraclass correlation coefficient (ICC), Bland-Altman analysis. A P value < 0.05 was considered statistically significant. RESULTS: Bright-blood iT2Prep-BOOST resulted in significantly improved image quality (mean ± standard deviation 3.8 ± 0.5 vs. 3.3 ± 0.8) and CR (2.9 ± 0.8 vs. 1.8 ± 0.5) compared with T2Prep-bSSFP, with a shorter scan time (7.8 ± 1.7 minutes vs. 12.9 ± 3.4 minutes) while providing a complementary 3D black-blood image. Aortic lumen diameter and vessel wall thickness measurements in bright-blood and black-blood images were in good agreement with T2Prep-bSSFP and HASTE images (<0.02 cm and <0.005 cm bias, respectively) and good intrareader (ICC > 0.96) and interreader (ICC > 0.94) agreement was observed for all measurements. DATA CONCLUSION: iT2Prep-BOOST might enable time-efficient simultaneous bright- and black-blood aortic imaging, with improved image quality compared to T2Prep-bSSFP and HASTE imaging, and comparable measurements for aortic wall and lumen dimensions. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Enfermedades de la Aorta , Angiografía por Resonancia Magnética , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Enfermedades de la Aorta/diagnóstico por imagen , Miocardio , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados
4.
Magn Reson Med ; 88(2): 663-675, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35344593

RESUMEN

PURPOSE: To implement and evaluate a simultaneous multi-slice balanced SSFP (SMS-bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2 ) at 1.5T. METHODS: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF-CAIPI with gradient-controlled local Larmor adjustment (GC-LOLA) in the presence of fat. A nine-slice SMS-bSSFP sequence using RF-CAIPI with GC-LOLA with high spatial resolution (1.4 × 1.4 mm2 ) and a conventional three-slice sequence with conventional spatial resolution (1.9 × 1.9 mm2 ) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal-to-noise ratio (SNR) on a 4-point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. RESULTS: Fat signal leakage was significantly higher for blipped CAIPI than for RF-CAIPI with GC-LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS-bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter-reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84). CONCLUSION: SMS-bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three-fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.


Asunto(s)
Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Perfusión , Reproducibilidad de los Resultados
5.
Eur Radiol ; 32(7): 4352-4360, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35230520

RESUMEN

OBJECTIVES: To assess clinical and cardiac magnetic resonance (CMR) imaging features of patients with peri-myocarditis following Coronavirus Disease 2019 (COVID-19) vaccination. METHODS: We retrospectively collected a case series of 27 patients who underwent CMR in the clinical suspect of heart inflammation following COVID-19 vaccination, from 16 large tertiary centers. Our patient's cohort was relatively young (36.6 ± 16.8 years), predominately included males (n = 25/27) with few comorbidities and covered a catchment area of approximately 8 million vaccinated patients. RESULTS: CMR revealed typical mid-subepicardial non-ischemic late gadolinium enhancement (LGE) in 23 cases and matched positively with CMR T2 criteria of myocarditis. In 7 cases, typical hallmarks of acute pericarditis were present. Short-term follow-up (median = 20 days) from presentation was uneventful for 25/27 patients and unavailable in two cases. CONCLUSIONS: While establishing a causal relationship between peri-myocardial inflammation and vaccine administration can be challenging, our clinical experience suggests that CMR should be performed for diagnosis confirmation and to drive clinical decision-making and follow-up. KEY POINTS: • Acute onset of dyspnea, palpitations, or acute and persisting chest pain after COVID-19 vaccination should raise the suspicion of possible myocarditis or pericarditis, and patients should seek immediate medical attention and treatment to help recovery and avoid complications. • In case of elevated troponin levels and/or relevant ECG changes, cardiac magnetic resonance should be considered as the best non-invasive diagnostic option to confirm the diagnosis of myocarditis or pericarditis and to drive clinical decision-making and follow-up.


Asunto(s)
COVID-19 , Miocarditis , Pericarditis , Arritmias Cardíacas , Vacunas contra la COVID-19/efectos adversos , Medios de Contraste/farmacología , Gadolinio/farmacología , Humanos , Inflamación , Imagen por Resonancia Magnética , Masculino , Miocarditis/diagnóstico por imagen , Miocarditis/etiología , Pericarditis/diagnóstico por imagen , Pericarditis/etiología , Estudios Retrospectivos , Vacunación
6.
Radiology ; 298(3): 578-586, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33464179

RESUMEN

Background Clinical guidelines recommend the use of established T2 mapping sequences to detect and quantify myocarditis and edema, but T2 mapping is performed in two dimensions with limited coverage and repetitive breath holds. Purpose To assess the reproducibility of an accelerated free-breathing three-dimensional (3D) whole-heart T2 MRI mapping sequence in phantoms and participants without a history of cardiac disease and to investigate its clinical performance in participants with suspected myocarditis. Materials and Methods Eight participants (three women, mean age, 31 years ± 4 [standard deviation]; cohort 1) without a history of cardiac disease and 25 participants (nine women, mean age, 45 years ± 17; cohort 2) with clinically suspected myocarditis underwent accelerated free-breathing 3D whole-heart T2 mapping with 100% respiratory scanning efficiency at 1.5 T. The participants were enrolled from November 2018 to August 2020. Three repeated scans were performed on 2 separate days in cohort 1. Segmental variations in T2 relaxation times of the left ventricular myocardium were assessed, and intrasession and intersession reproducibility were measured. In cohort 2, segmental myocardial T2 values, detection of focal inflammation, and map quality were compared with those obtained from clinical breath-hold two-dimensional (2D) T2 mapping. Statistical differences were assessed using the nonparametric Mann-Whitney and Kruskal-Wallis tests, whereas the paired Wilcoxon signed-rank test was used to assess subjective scores. Results Whole-heart T2 maps were acquired in a mean time of 6 minutes 53 seconds ± 1 minute 5 seconds at 1.5 mm3 resolution. Breath-hold 2D and free-breathing 3D T2 mapping had similar intrasession (mean T2 change of 3.2% and 2.3% for 2D and 3D, respectively) and intersession (4.8% and 4.9%, respectively) reproducibility. The two T2 mapping sequences showed similar map quality (P = .23, cohort 2). Abnormal myocardial segments were identified with confidence (score 3) in 14 of 25 participants (56%) with 3D T2 mapping and only in 10 of 25 participants (40%) with 2D T2 mapping. Conclusion High-spatial-resolution three-dimensional (3D) whole-heart T2 mapping shows high intrasession and intersession reproducibility and helps provide T2 myocardial characterization in agreement with clinical two-dimensional reference, while enabling 3D assessment of focal disease with higher confidence. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Friedrich in this issue.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Miocarditis/diagnóstico por imagen , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Prospectivos , Reproducibilidad de los Resultados
7.
Am Heart J ; 240: 89-100, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34174217

RESUMEN

BACKGROUND: It has not yet been established whether higher-dose statins have beneficial effects on cardiovascular events in patients with stable coronary artery disease (CAD) and renal dysfunction. METHODS: The REAL-CAD study is a prospective, multicenter, open-label trial. As a substudy, we categorized patients by an estimated glomerular filtration rate (eGFR) as follows: eGFR ≥60 (n = 7,768); eGFR ≥45 and <60 (n = 3,176); and eGFR <45 mL/Min/1.73 m2 (n = 1,164), who were randomized to pitavastatin 4mg or 1mg therapy. The primary endpoint was a composite of cardiovascular death, non-fatal myocardial infarction, non-fatal ischemic stroke, or unstable angina, and was assessed by the log-rank test and Cox proportional hazards model. RESULTS: The baseline characteristics and medications were largely well-balanced between two groups. The magnitude of low-density lipoprotein cholesterol (LDL-C) reduction at 6 months in high- and low-dose pitavastatin groups was comparable among all eGFR categories. During a median follow-up of 3.9 years, high- compared with low-dose pitavastatin significantly reduced cardiovascular events in patients with eGFR ≥60 (hazard ratio (HR) 0.73; 95% confidence interval (CI) 0.58-0.91; P = .006), and reduced but not significant for patients with eGFR ≥45 and <60 (HR 0.85; 95% CI, 0.63-1.14; P = .27) or eGFR <45 mL/Min/1.73 m2 (HR 0.90; 95% CI 0.62-1.33; P = .61). An interaction test of treatment by eGFR category was not significant (P value for interaction = .30). CONCLUSION: Higher-dose pitavastatin therapy reduced LDL levels and cardiovascular events in stable CAD patients irrespective of eGFR level, although the effect on events appeared to be numerically lower in patients with lower eGFR.


Asunto(s)
Angina Estable/tratamiento farmacológico , Angina Estable/fisiopatología , Enfermedades Cardiovasculares/prevención & control , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/fisiopatología , Tasa de Filtración Glomerular , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Quinolinas/administración & dosificación , Anciano , Angina Estable/sangre , Angina Estable/complicaciones , Proteína C-Reactiva/metabolismo , LDL-Colesterol/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/complicaciones , Femenino , Humanos , Lípidos/sangre , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
8.
J Cardiovasc Magn Reson ; 23(1): 57, 2021 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-33993890

RESUMEN

BACKGROUND: The widespread clinical application of coronary cardiovascular magnetic resonance (CMR) angiography (CMRA) for the assessment of coronary artery disease (CAD) remains limited due to low scan efficiency leading to prolonged and unpredictable acquisition times; low spatial-resolution; and residual respiratory motion artefacts resulting in limited image quality. To overcome these limitations, we have integrated highly undersampled acquisitions with image-based navigators and non-rigid motion correction to enable high resolution (sub-1 mm3) free-breathing, contrast-free 3D whole-heart coronary CMRA with 100% respiratory scan efficiency in a clinically feasible and predictable acquisition time. OBJECTIVES: To evaluate the diagnostic performance of this coronary CMRA framework against coronary computed tomography angiography (CTA) in patients with suspected CAD. METHODS: Consecutive patients (n = 50) with suspected CAD were examined on a 1.5T CMR scanner. We compared the diagnostic accuracy of coronary CMRA against coronary CTA for detecting a ≥ 50% reduction in luminal diameter. RESULTS: The 50 recruited patients (55 ± 9 years, 33 male) completed coronary CMRA in 10.7 ± 1.4 min. Twelve (24%) had significant CAD on coronary CTA. Coronary CMRA obtained diagnostic image quality in 95% of all, 97% of proximal, 97% of middle and 90% of distal coronary segments. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were: per patient (100%, 74%, 55%, 100% and 80%), per vessel (81%, 88%, 46%, 97% and 88%) and per segment (76%, 95%, 44%, 99% and 94%) respectively. CONCLUSIONS: The high diagnostic image quality and diagnostic performance of coronary CMRA compared against coronary CTA demonstrates the potential of coronary CMRA as a robust and safe non-invasive alternative for excluding significant disease in patients at low-intermediate risk of CAD.


Asunto(s)
Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
9.
J Cardiovasc Magn Reson ; 23(1): 26, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33685501

RESUMEN

INTRODUCTION: Heart failure (HF) in hypertrophic cardiomyopathy (HCM) is associated with high morbidity and mortality. Predictors of HF, in particular the role of myocardial fibrosis and microvascular ischemia remain unclear. We assessed the predictive value of cardiovascular magnetic resonance (CMR) for development of HF in HCM in an observational cohort study. METHODS: Serial patients with HCM underwent CMR, including adenosine first-pass perfusion, left atrial (LA) and left ventricular (LV) volumes indexed to body surface area (i) and late gadolinium enhancement (%LGE- as a % of total myocardial mass). We used a composite endpoint of HF death, cardiac transplantation, and progression to NYHA class III/IV. RESULTS: A total of 543 patients with HCM underwent CMR, of whom 94 met the composite endpoint at baseline. The remaining 449 patients were followed for a median of 5.6 years. Thirty nine patients (8.7%) reached the composite endpoint of HF death (n = 7), cardiac transplantation (n = 2) and progression to NYHA class III/IV (n = 20). The annual incidence of HF was 2.0 per 100 person-years, 95% CI (1.6-2.6). Age, previous non-sustained ventricular tachycardia, LV end-systolic volume indexed to body surface area (LVESVI), LA volume index ; LV ejection fraction, %LGE and presence of mitral regurgitation were significant univariable predictors of HF, with LVESVI (Hazard ratio (HR) 1.44, 95% confidence interval (95% CI) 1.16-1.78, p = 0.001), %LGE per 10% (HR 1.44, 95%CI 1.14-1.82, p = 0.002) age (HR 1.37, 95% CI 1.06-1.77, p = 0.02) and mitral regurgitation (HR 2.6, p = 0.02) remaining independently predictive on multivariable analysis. The presence or extent of inducible perfusion defect assessed using a visual score did not predict outcome (p = 0.16, p = 0.27 respectively). DISCUSSION: The annual incidence of HF in a contemporary ambulatory HCM population undergoing CMR is low. Myocardial fibrosis and LVESVI are strongly predictive of future HF, however CMR visual assessment of myocardial perfusion was not.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Circulación Coronaria , Insuficiencia Cardíaca/etiología , Imagen por Resonancia Magnética , Microcirculación , Imagen de Perfusión Miocárdica , Miocardio/patología , Adulto , Anciano , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/patología , Cardiomiopatía Hipertrófica/fisiopatología , Progresión de la Enfermedad , Femenino , Fibrosis , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda
10.
Circ J ; 85(10): 1710-1718, 2021 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-34078824

RESUMEN

BACKGROUND: The impact of chronic kidney disease (CKD) on long-term outcomes following acute myocardial infarction (AMI) in the era of modern primary PCI with optimal medical therapy is still in debate.Methods and Results:A total of 3,281 patients with AMI were enrolled in the J-MINUET registry, with primary PCI of 93.1% in STEMI. CKD stage on admission was classified into: no CKD (eGFR ≥60 mL/min/1.73 m2); moderate CKD (60>eGFR≥30 mL/min/1.73 m2); and severe CKD (eGFR <30 mL/min/1.73 m2). While the primary endpoint was all-cause mortality, the secondary endpoint was major adverse cardiac events (MACE), defined as a composite of all-cause death, cardiac failure, myocardial infarction (MI) and stroke. Of the 3,281 patients, 1,878 had no CKD, 1,073 had moderate CKD and 330 had severe CKD. Pre-person-days age- and sex-adjusted in-hospital mortality significantly increased from 0.014% in no CKD through 0.042% in moderate CKD to 0.084% in severe CKD (P<0.0001). Three-year mortality and MACE significantly deteriorated from 5.09% and 15.8% in no CKD through 16.3% and 38.2% in moderate CKD to 36.7% and 57.9% in severe CKD, respectively (P<0.0001). C-index significantly increased from the basic model of 0.815 (0.788-0.841) to 0.831 (0.806-0.857), as well as 0.731 (0.708-0.755) to 0.740 (0.717-0.764) when adding CKD stage to the basic model in predicting 3-year mortality (P=0.013; net reclassification improvement [NRI] 0.486, P<0.0001) and MACE (P=0.046; NRI 0.331, P<0.0001) respectively. CONCLUSIONS: CKD remains a useful predictor of in-hospital and 3-year mortality as well as MACE after AMI in the modern PCI and optimal medical therapy era.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica , Hospitales , Humanos , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Resultado del Tratamiento
11.
Magn Reson Med ; 83(3): 988-1002, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31535729

RESUMEN

PURPOSE: To enable free-breathing whole-heart 3D T2 mapping with high isotropic resolution in a clinically feasible and predictable scan time. This 3D motion-corrected undersampled signal matched (MUST) T2 map is achieved by combining an undersampled motion-compensated T2 -prepared Cartesian acquisition with a high-order patch-based reconstruction. METHODS: The 3D MUST-T2 mapping acquisition consists of an electrocardiogram-triggered, T2 -prepared, balanced SSFP sequence with nonselective saturation pulses. Three undersampled T2 -weighted volumes are acquired using a 3D Cartesian variable-density sampling with increasing T2 preparation times. A 2D image-based navigator is used to correct for respiratory motion of the heart and allow 100% scan efficiency. Multicontrast high-dimensionality undersampled patch-based reconstruction is used in concert with dictionary matching to generate 3D T2 maps. The proposed framework was evaluated in simulations, phantom experiments, and in vivo (10 healthy subjects, 2 patients) with 1.5-mm3 isotropic resolution. Three-dimensional MUST-T2 was compared against standard multi-echo spin-echo sequence (phantom) and conventional breath-held single-shot 2D SSFP T2 mapping (in vivo). RESULTS: Three-dimensional MUST-T2 showed high accuracy in phantom experiments (R2 > 0.99). The precision of T2 values was similar for 3D MUST-T2 and 2D balanced SSFP T2 mapping in vivo (5 ± 1 ms versus 4 ± 2 ms, P = .52). Slightly longer T2 values were observed with 3D MUST-T2 in comparison to 2D balanced SSFP T2 mapping (50.7 ± 2 ms versus 48.2 ± 1 ms, P < .05). Preliminary results in patients demonstrated T2 values in agreement with literature values. CONCLUSION: The proposed approach enables free-breathing whole-heart 3D T2 mapping with high isotropic resolution in about 8 minutes, achieving accurate and precise T2 quantification of myocardial tissue in a clinically feasible scan time.


Asunto(s)
Corazón/diagnóstico por imagen , Imagenología Tridimensional , Imagen por Resonancia Magnética , Adulto , Algoritmos , Enfermedades Cardiovasculares/patología , Simulación por Computador , Femenino , Frecuencia Cardíaca , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Movimiento (Física) , Miocardio/patología , Fantasmas de Imagen , Respiración
12.
J Cardiovasc Magn Reson ; 22(1): 88, 2020 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-33317570

RESUMEN

BACKGROUND: The free-breathing 3D whole-heart T2-prepared Bright-blood and black-blOOd phase SensiTive inversion recovery (BOOST) cardiovascular magnetic resonance (CMR) sequence was recently proposed for simultaneous bright-blood coronary CMR angiography and black-blood late gadolinium enhancement (LGE) imaging. This sequence enables simultaneous visualization of cardiac anatomy, coronary arteries and fibrosis. However, high-resolution (< 1.4 × 1.4 × 1.4 mm3) fully-sampled BOOST requires long acquisition times of ~ 20 min. METHODS: In this work, we propose to extend a highly efficient respiratory-resolved motion-corrected reconstruction framework (XD-ORCCA) to T2-prepared BOOST to enable high-resolution 3D whole-heart coronary CMR angiography and black-blood LGE in a clinically feasible scan time. Twelve healthy subjects were imaged without contrast injection (pre-contrast BOOST) and 10 patients with suspected cardiovascular disease were imaged after contrast injection (post-contrast BOOST). A quantitative analysis software was used to compare accelerated pre-contrast BOOST against the fully-sampled counterpart (vessel sharpness and length of the left and right coronary arteries). Moreover, three cardiologists performed diagnostic image quality scoring for clinical 2D LGE and both bright- and black-blood 3D BOOST imaging using a 4-point scale (1-4, non-diagnostic-fully diagnostic). A two one-sided test of equivalence (TOST) was performed to compare the pre-contrast BOOST images. Nonparametric TOST was performed to compare post-contrast BOOST image quality scores. RESULTS: The proposed method produces images from 3.8 × accelerated non-contrast-enhanced BOOST acquisitions with comparable vessel length and sharpness to those obtained from fully- sampled scans in healthy subjects. Moreover, in terms of visual grading, the 3D BOOST LGE datasets (median 4) and the clinical 2D counterpart (median 3.5) were found to be statistically equivalent (p < 0.05). In addition, bright-blood BOOST images allowed for visualization of the proximal and middle left anterior descending and right coronary sections with high diagnostic quality (mean score > 3.5). CONCLUSIONS: The proposed framework provides high-resolution 3D whole-heart BOOST images from a single free-breathing acquisition in ~ 7 min.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Imagenología Tridimensional , Imagen por Resonancia Magnética , Miocardio/patología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Medios de Contraste/administración & dosificación , Femenino , Fibrosis , Cardiopatías/patología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Flujo de Trabajo , Adulto Joven
13.
J Cardiovasc Magn Reson ; 22(1): 24, 2020 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-32299445

RESUMEN

BACKGROUND: To enable free-breathing whole-heart sub-millimeter resolution coronary magnetic resonance angiography (CMRA) in a clinically feasible scan time by combining low-rank patch-based undersampled reconstruction (3D-PROST) with a highly accelerated non-rigid motion correction framework. METHODS: Non-rigid motion corrected CMRA combined with 2D image-based navigators has been previously proposed to enable 100% respiratory scan efficiency in modestly undersampled acquisitions. Achieving sub-millimeter isotropic resolution with such techniques still requires prohibitively long acquisition times. We propose to combine 3D-PROST reconstruction with a highly accelerated non-rigid motion correction framework to achieve sub-millimeter resolution CMRA in less than 10 min. Ten healthy subjects and eight patients with suspected coronary artery disease underwent 4-5-fold accelerated free-breathing whole-heart CMRA with 0.9 mm3 isotropic resolution. Vessel sharpness, vessel length and image quality obtained with the proposed non-rigid (NR) PROST approach were compared against translational correction only (TC-PROST) and a previously proposed NR motion-compensated technique (non-rigid SENSE) in healthy subjects. For the patient study, image quality scoring and visual comparison with coronary computed tomography angiography (CCTA) were performed. RESULTS: Average scan times [min:s] were 6:01 ± 0:59 (healthy subjects) and 8:29 ± 1:41 (patients). In healthy subjects, vessel sharpness of the left anterior descending (LAD) and right (RCA) coronary arteries were improved with the proposed non-rigid PROST (LAD: 51.2 ± 8.8%, RCA: 61.2 ± 9.1%) in comparison to TC-PROST (LAD: 43.8 ± 5.1%, P = 0.051, RCA: 54.3 ± 8.3%, P = 0.218) and non-rigid SENSE (LAD: 46.1 ± 5.8%, P = 0.223, RCA: 56.7 ± 9.6%, P = 0.50), although differences were not statistically significant. The average visual image quality score was significantly higher for NR-PROST (LAD: 3.2 ± 0.6, RCA: 3.3 ± 0.7) compared with TC-PROST (LAD: 2.1 ± 0.6, P = 0.018, RCA: 2.0 ± 0.7, P = 0.014) and non-rigid SENSE (LAD: 2.3 ± 0.5, P = 0.008, RCA: 2.5 ± 0.7, P = 0.016). In patients, the proposed approach showed good delineation of the coronaries, in agreement with CCTA, with image quality scores and vessel sharpness similar to that of healthy subjects. CONCLUSIONS: We demonstrate the feasibility of combining high undersampling factors with non-rigid motion-compensated reconstruction to obtain high-quality sub-millimeter isotropic CMRA images in ~ 8 min. Validation in a larger cohort of patients with coronary artery disease is now warranted.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Adulto , Estudios de Casos y Controles , Angiografía por Tomografía Computarizada , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Flujo de Trabajo
14.
Magn Reson Med ; 81(1): 102-115, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30058252

RESUMEN

PURPOSE: To enable whole-heart 3D coronary magnetic resonance angiography (CMRA) with isotropic sub-millimeter resolution in a clinically feasible scan time by combining respiratory motion correction with highly accelerated variable density sampling in concert with a novel 3D patch-based undersampled reconstruction (3D-PROST). METHODS: An undersampled variable density spiral-like Cartesian trajectory was combined with 2D image-based navigators to achieve 100% respiratory efficiency and predictable scan time. 3D-PROST reconstruction integrates structural information from 3D patch neighborhoods through sparse representation, thereby exploiting the redundancy of the 3D anatomy of the coronary arteries in an efficient low-rank formulation. The proposed framework was evaluated in a static resolution phantom and in 10 healthy subjects with isotropic resolutions of 1.2 mm3 and 0.9 mm3 and undersampling factors of ×5 and ×9. 3D-PROST was compared against fully sampled (1.2 mm3 only), conventional parallel imaging, and compressed sensing reconstructions. RESULTS: Phantom and in vivo (1.2 mm3 ) reconstructions were in excellent agreement with the reference fully sampled image. In vivo average acquisition times (min:s) were 7:57 ± 1:18 (×5) and 4:35 ± 0:44 (×9) for 0.9 mm3 resolution. Sub-millimeter 3D-PROST resulted in excellent depiction of the left and right coronary arteries including small branch vessels, leading to further improvements in vessel sharpness and visible vessel length in comparison with conventional reconstruction techniques. Image quality rated by 2 experts demonstrated that 3D-PROST provides good image quality and is robust even at high acceleration factors. CONCLUSION: The proposed approach enables free-breathing whole-heart 3D CMRA with isotropic sub-millimeter resolution in <5 min and achieves improved coronary artery visualization in a short and predictable scan time.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Respiración , Adulto , Vasos Coronarios/anatomía & histología , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Movimiento (Física) , Fantasmas de Imagen , Reproducibilidad de los Resultados
15.
Circulation ; 135(22): 2106-2115, 2017 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-28351901

RESUMEN

BACKGROUND: Current guidelines only recommend the use of an implantable cardioverter defibrillator in patients with dilated cardiomyopathy for the primary prevention of sudden cardiac death (SCD) in those with a left ventricular ejection fraction (LVEF) <35%. However, registries of out-of-hospital cardiac arrests demonstrate that 70% to 80% of such patients have an LVEF >35%. Patients with an LVEF >35% also have low competing risks of death from nonsudden causes. Therefore, those at high risk of SCD may gain longevity from successful implantable cardioverter defibrillator therapy. We investigated whether late gadolinium enhancement (LGE) cardiovascular magnetic resonance identified patients with dilated cardiomyopathy without severe LV systolic dysfunction at high risk of SCD. METHODS: We prospectively investigated the association between midwall LGE and the prespecified primary composite outcome of SCD or aborted SCD among consecutive referrals with dilated cardiomyopathy and an LVEF ≥40% to our center between January 2000 and December 2011 who did not have a preexisting indication for implantable cardioverter defibrillator implantation. RESULTS: Of 399 patients (145 women, median age 50 years, median LVEF 50%, 25.3% with LGE) followed for a median of 4.6 years, 18 of 101 (17.8%) patients with LGE reached the prespecified end point, compared with 7 of 298 (2.3%) without (hazard ratio [HR], 9.2; 95% confidence interval [CI], 3.9-21.8; P<0.0001). Nine patients (8.9%) with LGE compared with 6 (2.0%) without (HR, 4.9; 95% CI, 1.8-13.5; P=0.002) died suddenly, whereas 10 patients (9.9%) with LGE compared with 1 patient (0.3%) without (HR, 34.8; 95% CI, 4.6-266.6; P<0.001) had aborted SCD. After adjustment, LGE predicted the composite end point (HR, 9.3; 95% CI, 3.9-22.3; P<0.0001), SCD (HR, 4.8; 95% CI, 1.7-13.8; P=0.003), and aborted SCD (HR, 35.9; 95% CI, 4.8-271.4; P<0.001). Estimated HRs for the primary end point for patients with an LGE extent of 0% to 2.5%, 2.5% to 5%, and >5% compared with those without LGE were 10.6 (95% CI, 3.9-29.4), 4.9 (95% CI, 1.3-18.9), and 11.8 (95% CI, 4.3-32.3), respectively. CONCLUSIONS: Midwall LGE identifies a group of patients with dilated cardiomyopathy and an LVEF ≥40% at increased risk of SCD and low risk of nonsudden death who may benefit from implantable cardioverter defibrillator implantation. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT00930735.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/mortalidad , Muerte Súbita Cardíaca/patología , Gadolinio , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Adulto , Anciano , Cardiomiopatía Dilatada/epidemiología , Endotelio Vascular/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Gadolinio/administración & dosificación , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/epidemiología
16.
J Cardiovasc Magn Reson ; 20(1): 84, 2018 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-30526627

RESUMEN

BACKGROUND: Simultaneous-Multi-Slice (SMS) perfusion imaging has the potential to acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial resolution. To maximise signal-to-noise ratio (SNR), SMS can be combined with a balanced steady state free precession (bSSFP) readout. Furthermore, application of gradient-controlled local Larmor adjustment (GC-LOLA) can ensure robustness against off-resonance artifacts and SNR loss can be mitigated by applying iterative reconstruction with spatial and temporal regularisation. The objective of this study was to compare cardiovascular magnetic resonance (CMR) myocardial perfusion imaging using SMS bSSFP imaging with GC-LOLA and iterative reconstruction to 3 slice bSSFP. METHODS: Two contrast-enhanced rest perfusion sequences were acquired in random order in 8 patients: 6-slice SMS bSSFP and 3 slice bSSFP. All images were reconstructed with TGRAPPA. SMS images were also reconstructed using a non-linear iterative reconstruction with L1 regularisation in wavelet space (SMS-iter) with 7 different combinations for spatial (λσ) and temporal (λτ) regularisation parameters. Qualitative ratings of overall image quality (0 = poor image quality, 1 = major artifact, 2 = minor artifact, 3 = excellent), perceived SNR (0 = poor SNR, 1 = major noise, 2 = minor noise, 3 = high SNR), frequency of sequence related artifacts and patient related artifacts were undertaken. Quantitative analysis of contrast ratio (CR) and percentage of dark rim artifact (DRA) was performed. RESULTS: Among all SMS-iter reconstructions, SMS-iter 6 (λσ 0.001 λτ 0.005) was identified as the optimal reconstruction with the highest overall image quality, least sequence related artifact and higher perceived SNR. SMS-iter 6 had superior overall image quality (2.50 ± 0.53 vs 1.50 ± 0.53, p = 0.005) and perceived SNR (2.25 ± 0.46 vs 0.75 ± 0.46, p = 0.010) compared to 3 slice bSSFP. There were no significant differences in sequence related artifact, CR (3.62 ± 0.39 vs 3.66 ± 0.65, p = 0.88) or percentage of DRA (5.25 ± 6.56 vs 4.25 ± 4.30, p = 0.64) with SMS-iter 6 compared to 3 slice bSSFP. CONCLUSIONS: SMS bSSFP with GC-LOLA and iterative reconstruction improved image quality compared to a 3 slice bSSFP with doubled spatial coverage and preserved in-plane spatial resolution. Future evaluation in patients with coronary artery disease is warranted.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen de Perfusión Miocárdica/métodos , Adulto , Anciano , Cardiomiopatías/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados
17.
J Cardiovasc Magn Reson ; 20(1): 74, 2018 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-30454074

RESUMEN

BACKGROUND: Clinical evaluation of stress perfusion cardiovascular magnetic resonance (CMR) is currently based on visual assessment and has shown high diagnostic accuracy in previous clinical trials, when performed by expert readers or core laboratories. However, these results may not be generalizable to clinical practice, particularly when less experienced readers are concerned. Other factors, such as the level of training, the extent of ischemia, and image quality could affect the diagnostic accuracy. Moreover, the role of rest images has not been clarified. The aim of this study was to assess the diagnostic accuracy of visual assessment for operators with different levels of training and the additional value of rest perfusion imaging, and to compare visual assessment and automated quantitative analysis in the assessment of coronary artery disease (CAD). METHODS: We evaluated 53 patients with known or suspected CAD referred for stress-perfusion CMR. Nine operators (equally divided in 3 levels of competency) blindly reviewed each case twice with a 2-week interval, in a randomised order, with and without rest images. Semi-automated Fermi deconvolution was used for quantitative analysis and estimation of myocardial perfusion reserve as the ratio of stress to rest perfusion estimates. RESULTS: Level-3 operators correctly identified significant CAD in 83.6% of the cases. This percentage dropped to 65.7% for Level-2 operators and to 55.7% for Level-1 operators (p < 0.001). Quantitative analysis correctly identified CAD in 86.3% of the cases and was non-inferior to expert readers (p = 0.56). When rest images were available, a significantly higher level of confidence was reported (p = 0.022), but no significant differences in diagnostic accuracy were measured (p = 0.34). CONCLUSIONS: Our study demonstrates that the level of training is the main determinant of the diagnostic accuracy in the identification of CAD. Level-3 operators performed at levels comparable with the results from clinical trials. Rest images did not significantly improve diagnostic accuracy, but contributed to higher confidence in the results. Automated quantitative analysis performed similarly to level-3 operators. This is of increasing relevance as recent technical advances in image reconstruction and analysis techniques are likely to permit the clinical translation of robust and fully automated quantitative analysis into routine clinical practice.


Asunto(s)
Adenosina/administración & dosificación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Educación de Postgrado en Medicina/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Variaciones Dependientes del Observador , Vasodilatadores/administración & dosificación , Percepción Visual , Anciano , Automatización , Certificación , Competencia Clínica , Enfermedad de la Arteria Coronaria/fisiopatología , Educación de Postgrado en Medicina/normas , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
18.
J Cardiovasc Magn Reson ; 19(1): 94, 2017 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-29178893

RESUMEN

BACKGROUND: Phase sensitive inversion recovery (PSIR) applied to late gadolinium enhancement (LGE) imaging is widely used in clinical practice. However, conventional 2D PSIR LGE sequences provide sub-optimal contrast between scar tissue and blood pool, rendering the detection of subendocardial infarcts and scar segmentation challenging. Furthermore, the acquisition of a low flip angle reference image doubles the acquisition time without providing any additional diagnostic information. The purpose of this study was to develop and test a novel 3D whole-heart PSIR-like framework, named BOOST, enabling simultaneous black-blood LGE assessment and bright-blood visualization of cardiac anatomy. METHODS: The proposed approach alternates the acquisition of a 3D volume preceded by a T2-prepared Inversion Recovery (T2Prep-IR) module (magnitude image) with the acquisition of a T2-prepared 3D volume (reference image). The two volumes (T2Prep-IR BOOST and bright-blood T2Prep BOOST) are combined in a PSIR-like reconstruction to obtain a complementary 3D black-blood volume for LGE assessment (PSIR BOOST). The black-blood PSIR BOOST and the bright-blood T2Prep BOOST datasets were compared to conventional clinical sequences for scar detection and coronary CMR angiography (CMRA) in 18 patients with a spectrum of cardiovascular disease (CVD). RESULTS: Datasets from 12 patients were quantitatively analysed. The black-blood PSIR BOOST dataset provided statistically improved contrast to noise ratio (CNR) between blood and scar when compared to a clinical 2D PSIR sequence (15.8 ± 3.3 and 4.1 ± 5.6, respectively). Overall agreement in LGE depiction was found between 3D black-blood PSIR BOOST and clinical 2D PSIR acquisitions, with 11/12 PSIR BOOST datasets considered diagnostic. The bright-blood T2Prep BOOST dataset provided high quality depiction of the proximal coronary segments, with improvement of visual score when compared to a clinical CMRA sequence. Acquisition time of BOOST (~10 min), providing information on both LGE uptake and heart anatomy, was comparable to that of a clinical single CMRA sequence. CONCLUSIONS: The feasibility of BOOST for simultaneous black-blood LGE assessment and bright-blood coronary angiography was successfully tested in patients with cardiovascular disease. The framework enables free-breathing multi-contrast whole-heart acquisitions with 100% scan efficiency and predictable scan time. Complementary information on 3D LGE and heart anatomy are obtained reducing examination time.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste/administración & dosificación , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Angiografía por Resonancia Magnética/métodos , Compuestos Organometálicos/administración & dosificación , Adulto , Anciano , Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Angiografía Coronaria/instrumentación , Vasos Coronarios/patología , Electrocardiografía , Estudios de Factibilidad , Femenino , Cardiopatías/patología , Humanos , Angiografía por Resonancia Magnética/instrumentación , Masculino , Persona de Mediana Edad , Miocardio/patología , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Supervivencia Tisular
19.
Circ J ; 79(4): 808-17, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25740668

RESUMEN

BACKGROUND: This study evaluated the ability of a newly developed integrated backscatter intravascular ultrasound (IB-IVUS) system (VISIWAVE, Terumo, Tokyo, Japan) to detect optical coherence tomography (OCT)-verified thin cap fibroatheroma (TCFA) and assessed the correlation with peri-procedural myocardial infarction (PMI) after percutaneous coronary intervention (PCI). METHODS AND RESULTS: One hundred culprit lesions in 100 consecutive patients with ischemic heart disease who consented to repeated IVUS and OCT prior to PCI were studied. Of 100 lesions, 48 had OCT-verified TCFA with a cap thickness <65 µm. Such lesions had larger percentage lipid area and lipid angle >2 quadrants on IB-IVUS. A lipid core abutting lumen (LCAL) was defined as a lipid core pool in the plaque area, directly contacting with the lumen regardless of its circumferential extension. IB-IVUS-identified TCFA defined as a combination of percentage lipid area ≥53.6%, remodeling index ≥1.03, and the presence of LCAL was the best predictor of OCT-verified TCFA with sensitivity, specificity, positive and negative predictive values, and accuracy of 72.9%, 90.4%, 87.5%, 78.3%, and 82.0%, respectively. IB-IVUS-identified TCFA as well as OCT-verified TCFA were significant independent predictors of PMI, after adjusting for other predictors on multivariate analysis. CONCLUSIONS: IB-IVUS can be used to identify plaques with a high prevalence of TCFA. Such techniques can therefore potentially be used to identify lesions with an elevated risk of PMI after PCI.


Asunto(s)
Lípidos , Infarto del Miocardio , Intervención Coronaria Percutánea/efectos adversos , Complicaciones Posoperatorias/patología , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/patología , Placa Aterosclerótica/patología , Placa Aterosclerótica/cirugía
20.
Circulation ; 128(15): 1623-33, 2013 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-23965488

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance is the gold-standard technique for the assessment of ventricular function. Although left ventricular volumes and ejection fraction are strong predictors of outcome in dilated cardiomyopathy (DCM), there are limited data regarding the prognostic significance of right ventricular (RV) systolic dysfunction (RVSD). We investigated whether cardiovascular magnetic resonance assessment of RV function has prognostic value in DCM. METHODS AND RESULTS: We prospectively studied 250 consecutive DCM patients with the use of cardiovascular magnetic resonance. RVSD, defined by RV ejection fraction≤45%, was present in 86 (34%) patients. During a median follow-up period of 6.8 years, there were 52 deaths, and 7 patients underwent cardiac transplantation. The primary end point of all-cause mortality or cardiac transplantation was reached by 42 of 86 patients with RVSD and 17 of 164 patients without RVSD (49% versus 10%; hazard ratio, 5.90; 95% confidence interval [CI], 3.35-10.37; P<0.001). On multivariable analysis, RVSD remained a significant independent predictor of the primary end point (hazard ratio, 3.90; 95% CI, 2.16-7.04; P<0.001), as well as secondary outcomes of cardiovascular mortality or cardiac transplantation (hazard ratio, 3.35; 95% CI, 1.76-6.39; P<0.001), and heart failure death, heart failure hospitalization, or cardiac transplantation (hazard ratio, 2.70; 95% CI, 1.32-5.51; P=0.006). Assessment of RVSD improved risk stratification for all-cause mortality or cardiac transplantation (net reclassification improvement, 0.31; 95% CI 0.10-0.53; P=0.001). CONCLUSIONS: RVSD is a powerful, independent predictor of transplant-free survival and adverse heart failure outcomes in DCM. Cardiovascular magnetic resonance assessment of RV function is important in the evaluation and risk stratification of DCM patients.


Asunto(s)
Cardiomiopatía Dilatada/mortalidad , Cardiomiopatía Dilatada/patología , Disfunción Ventricular Derecha/mortalidad , Disfunción Ventricular Derecha/patología , Adulto , Anciano , Cardiomiopatía Dilatada/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA