Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Lab ; 53(1-2): 1-9, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17323819

RESUMEN

BACKGROUND AND OBJECTIVE: Discrepancies between serum and heparin plasma samples have been described for many commercial troponin assays including the cardiac troponin T (cTnT) assay. Using the current 3rd generation Elecsys Troponin T immunoassay, heparin plasma cannot be recommended for the determination of cTnT due to systematic lower test results caused by a direct interference of the immunoassay by heparin. The purpose of the multicenter study was to evaluate the analytical performance of an improved 4th generation Elecsys Troponin T immunoassay with a special focus on the comparability of cTnT results determined in heparin plasma and serum. METHODS AND RESULTS: The multicenter evaluation was performed in 10 clinical laboratories according to a standardized protocol (Roche Diagnostics, Penzberg, Germany, Study No. B05P008). The Elecsys Troponin T immunoassay was performed on the Modular Analytics E170 and Elecsys 2010 systems. Intraassay imprecision (n = 21) and total imprecision (2 runs/d, 10 days, triplicate measurements) were evaluated using 2 commercial controls (Roche Diagnostics) and 6 different serum pools (cTnT: 0.0140 - 4.102 microg/L). Intraassay CVs ranged from 0.73 to 3.22%. Total imprecision CVs ranged from 3.61 to 35.45% (cTnT < 0.1 microg/L) and 1.82 to 9.09% (cTnT > 0.1 microg/L), respectively. The cut-off for myocardial necrosis was determined to be 0.03 microg/L using the 10% total imprecision CV criteria. Linearity was assessed by serial dilutions of 6 different serum samples using cTnT negative serum pools. Linearity was proven up to 21.3 microg/L (recoveries: 90% - 110%). Regression data of all comparison studies were calculated according to the method of Passing and Bablok. The method comparison between the 4th generation and the commercially available cTnT immunoassay showed highly similar results across the whole measuring range (0.01 - 25.0 microg/L): y = 1.024x -0.001, r = 0.998; n = 988. Using the commercially available cTnT reagent, the serum to heparin plasma comparison yielded a systematic bias to approximately 8% lower cTnT results in heparin plasma. However, suitable comparability was obtained using the 4th generation Elecsys cTnT assay. The regression analysis (serum vs. heparin plasma) across the studied measuring range (cTnT: 0.01 - 14 microg/L) yielded the following equation: y = 0.975x + 0.001; r = 0.986; n = 403. However, rare individual serum to matched heparin plasma samples still yielded poor comparability (deviation > 20%) using the 4th generation Elecsys Troponin T immunoassay. CONCLUSION: Our data confirm an excellent analytical performance of the improved troponin T immunoassay. Most importantly, no systematic bias between cTnT results determined in serum and heparin plasma was observed from data obtained in 7 evaluation sites. The performance of the 4th generation Elecsys Troponin T assay is therefore comparable to other commercially available troponin immunoassays. Further studies are necessary to investigate the cause of poor comparability of cTnT results in rare individual serum to matched heparin plasma samples.


Asunto(s)
Inmunoensayo/instrumentación , Inmunoensayo/métodos , Troponina T/análisis , Estudios de Evaluación como Asunto , Heparina/análisis , Heparina/sangre , Humanos , Análisis de Regresión , Troponina T/sangre
2.
Biochim Biophys Acta ; 669(2): 222-30, 1981 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-6269649

RESUMEN

Rat liver cytochrome c oxidase (ferrocytochrome c: oxygen oxidoreductase; EC 1.9.3.1) was separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis into 12 different polypeptide chains. Specific antisera against the holoenzyme and against purified subunits IV and VIII were used to characterize the enzyme complex. The antiserum against subunit IV precipitates from sodium dodecyl sulfate-dissociated mitochondria only subunit IV and from Triton X-100-dissolved mitochondria all 12 polypeptide chains, indicating their integral location within the enzyme complex. Different antisera against the holoenzyme only precipitate subunits IV, V and VIb from sodium dodecyl sulfate-dissociated mitochondria, suggesting the location of these subunits on the surface layer of the complex. Subunit VIII is thought to be located within the complex, since a specific antiserum does not precipitate the complex. The amino acid composition of all 12 protein subunits is different, thus excluding their origin from proteolytic degradation. The proteolytic degradation of subunit IV into IV during isolation of the enzyme was corroborated by the very similar amino acid composition of both proteins.


Asunto(s)
Complejo IV de Transporte de Electrones , Hígado/enzimología , Aminoácidos/análisis , Animales , Complejo Antígeno-Anticuerpo , Complejo IV de Transporte de Electrones/inmunología , Electroforesis en Gel de Poliacrilamida , Sueros Inmunes , Inmunodifusión , Sustancias Macromoleculares , Mitocondrias Hepáticas/enzimología , Péptidos/aislamiento & purificación , Ratas
3.
Wien Klin Wochenschr Suppl ; 191: 59-66, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1509757

RESUMEN

The sensitivity of a new homogeneous enzyme immunoassay for the determination of digoxin (CEDIA Digoxin assay) and a fluorescence polarization immunoassay (FPIA) to interference by digoxin-like immunoreactive factors (DLIF) was studied in sera from pregnant women, newborns, patients undergoing hemodialysis and patients with renal insufficiency, but without hemodialysis. None of the patients had been treated with digoxin or digitoxin. Cross-reactivity of DLIF in the CEDIA assay was generally lower than in the FPIA. Data on the distribution DLIF of values and method comparisons showed that sera of the four patient groups reacted in a completely different way in both assays, suggesting that the nature of DLIF in the four groups is not identical. Addition of digoxin to sera of patients not treated with this drug resulted in a reduction of the apparent DLIF concentration in the CEDIA assay and the FPIA. This shows that DLIF interference may be less pronounced in sera of patients undergoing digoxin therapy compared to untreated persons. Although the CEDIA assay is less sensitive to DLIF interference than the FPIA, further efforts are needed to reduce the extent of this interference.


Asunto(s)
Proteínas Sanguíneas/metabolismo , Digoxina/farmacocinética , Monitoreo de Drogas , Inmunoensayo de Polarización Fluorescente , Técnicas para Inmunoenzimas , Saponinas , Adulto , Cardenólidos , Femenino , Sangre Fetal/metabolismo , Humanos , Recién Nacido , Fallo Renal Crónico/sangre , Embarazo , Valores de Referencia , Diálisis Renal
4.
Wien Klin Wochenschr Suppl ; 180: 40-2; discussion 57-9, 1990.
Artículo en Alemán | MEDLINE | ID: mdl-2321390

RESUMEN

With the introduction of an improved method for the determination of fructosamine a new tool is available for the monitoring of diabetes. This method provides a good reproducibility together with a standardized quality control and is easily applicated to automated clinical chemistry analyzers. Besides the analytical performance in general the impact of preanalysis on fructosamine values is important for routine work. In a study with 20 volunteers the impact of orthostasis has been investigated. Changes in fructosamine concentration correspond to a shift in the concentration of other analytical parameters related to serum proteins.


Asunto(s)
Hexosaminas/sangre , Postura/fisiología , Adulto , Proteínas Sanguíneas/metabolismo , Ejercicio Físico/fisiología , Fructosamina , Humanos , Masculino , Valores de Referencia
5.
Wien Klin Wochenschr Suppl ; 191: 69-73, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1509759

RESUMEN

A new CEDIA assay for the measurement of digoxin in serum on random access analyzers was evaluated by twelve laboratories in Europe and the United States. Studies on the analytical range, reproducibility, calibration stability, recovery in controls, interlaboratory comparability, comparability with routine methods, and the effect of various interfering factors have been performed and the results are presented in this paper. The analytical performance was comparable to that of routine methods provided the manual pipetting step for pre-incubation was performed with accurate pipettes. A major advantage of the CEDIA Digoxin assay in terms of convenience is the simple two-point calibration procedure. Moreover, digoxin can be determined within 15 minutes after receiving the samples on random access analyzers like Boehringer Mannheim/Hitachi analysis systems. Thus, the CEDIA Digoxin assay represents an attractive alternative to the measurement of digoxin on dedicated immunochemical assay systems.


Asunto(s)
Digoxina/farmacocinética , Monitoreo de Drogas/instrumentación , Técnicas para Inmunoenzimas/instrumentación , Calibración , Digoxina/administración & dosificación , Relación Dosis-Respuesta a Droga , Humanos , Control de Calidad , Valores de Referencia
6.
Wien Klin Wochenschr Suppl ; 191: 73-6, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1509760

RESUMEN

We evaluated a CEDIA assay for the determination of digitoxin in serum on random access analyzers. The multicenter evaluation included studies on the analytical range, calibration stability and reproducibility of the new assay. Moreover, recovery in controls, transferability of results obtained in different laboratories, comparability with routine methods, and the effect of various interfering factors have been analyzed. Summarized the analytical performance was comparable to that of routine methods. The CEDIA Digitoxin assay represents an attractive alternative to established digitoxin immunoassays because it can be performed on random access analyzers, thus permitting the simultaneous determination of digitoxin and other serum analytes without sample splitting.


Asunto(s)
Digitoxina/farmacocinética , Monitoreo de Drogas/métodos , Técnicas para Inmunoenzimas , Digitoxina/administración & dosificación , Relación Dosis-Respuesta a Droga , Humanos , Valores de Referencia
7.
Clin Chim Acta ; 412(9-10): 748-54, 2011 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-21219893

RESUMEN

BACKGROUND: High-sensitivity cardiac troponin assays are being introduced clinically for earlier diagnosis of acute myocardial infarction (AMI). We evaluated the analytical performance of a high-sensitivity cardiac troponin T assay (hscTnT, Roche Diagnostics) in a multicenter, international trial. METHODS: Three US and 5 European sites evaluated hscTnT on the Modular® Analytics E170, cobas® 6000, Elecsys 2010, and cobas® e 411. Precision, accuracy, reportable range, an inter-laboratory comparison trial, and the 99th percentile of a reference population were assessed. RESULTS: Total imprecision (CVs) were 4.6-36.8% between 3.4 and 10.3 ng/L hscTnT. Assay linearity was up to 10,000 ng/L and the limit of blank and detection were 3 and 5 ng/L, respectively. The 99th percentile reference limit was 14.2 ng/L (n=533). No significant differences between specimen types, assay incubation time, or reagent lots existed. A substantial positive bias (76%) exists between the 4th generation and hscTnT assays at the low end of the measuring range (<50 ng/L). hscTnT serum pool concentrations were within 2SD limits of the mean of means in the comparison trial, indicating comparable results across multiple platforms and laboratories. CONCLUSION: The Roche hscTnT assay conforms to guideline precision requirements and will likely identify additional patients with myocardial injury suspicious for AMI.


Asunto(s)
Inmunoensayo/métodos , Troponina T/sangre , Adulto , Anciano , Recolección de Datos , Femenino , Humanos , Inmunoensayo/normas , Internacionalidad , Laboratorios , Límite de Detección , Modelos Lineales , Masculino , Persona de Mediana Edad , Valores de Referencia , Troponina T/inmunología , Adulto Joven
9.
Eur J Biochem ; 146(1): 211-7, 1985 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-2981683

RESUMEN

Isolated rat liver cytochrome c oxidase was cross-linked with the cleavable reagents dimethyl-3,3'-dithiobispropionimidate (DTBP), 3,3'-dithiobis(succinimidyl)propionate (DSP) and cupric di(1,10-phenanthroline) (CuP). The cross-linked products were separated by high-resolving two-dimensional dodecyl sulfate gel electrophoresis, which separates all thirteen polypeptides of the mammalian enzyme. With cupric di(1,10-phenanthroline) seven polypeptides (I-III, Va, Vb, VIIb and VIII) were cross-linked with each other and with itself, indicating the occurrence of free -SH groups in these polypeptides and a rearrangement of the native structure of the complex by cupric di(1,10-phenanthroline). With dimethyl-3,3'-dithiobispropionimidate or 3,3'-dithiobis(succinimidyl)propionate all nuclear-coded polypeptides, with the exception of polypeptide VIIa, formed cross-linked products with the three 'catalytic' polypeptides I-III, which are coded on mitochondrial DNA. Five additional cross-linked pairs were found between nuclear coded polypeptides. The close arrangement of nuclear coded polypeptides with the catalytic polypeptides suggests a regulatory function of these polypeptides.


Asunto(s)
Reactivos de Enlaces Cruzados , Complejo IV de Transporte de Electrones/aislamiento & purificación , Mitocondrias Hepáticas/enzimología , Animales , Fenómenos Químicos , Química , Electroforesis en Gel de Poliacrilamida , Imidoésteres , Fragmentos de Péptidos/análisis , Fenantrolinas , Ratas , Succinimidas
10.
Eur J Biochem ; 146(1): 219-25, 1985 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-2981684

RESUMEN

The orientation of the thirteen polypeptides of rat-liver cytochrome c oxidase in the inner mitochondrial membrane was studied by proteolytic digestion of mitoplasts and sonicated particles. After separation by sodium dodecylsulfate gel electrophoresis proteins were transferred on nitrocellulose, and individual polypeptides were identified by incubation with polypeptide-specific antisera, followed by fluorescein-isothiocyanate-conjugated protein A. The three catalytic polypeptides I-III and seven nuclear coded polypeptides (IV, Vb, VIa, VIc, VIIa, VIIb and VIII) were found accessible to proteases from the cytoplasmic phase. Polypeptides II, IV, Va, Vb and VIa were accessible from the matrix phase, indicating a transmembraneous orientation of polypeptides II, IV, Vb and VIa. Together with data on cross-linking and on cytochrome-c-protected labeling of polypeptides, a model of the cytochrome c oxidase complex was developed. It is suggested that the cytochrome c binding site on polypeptide II is surrounded by several nuclear-coded polypeptides, which may modulate the affinity of the enzyme towards cytochrome c.


Asunto(s)
Complejo IV de Transporte de Electrones/aislamiento & purificación , Mitocondrias Hepáticas/enzimología , Animales , Catálisis , Fenómenos Químicos , Química , Electroforesis en Gel de Poliacrilamida , Inmunoquímica , Membranas Intracelulares/enzimología , Proteínas de la Membrana/análisis , Fragmentos de Péptidos/análisis , Péptido Hidrolasas , Ratas , Sonicación , Partículas Submitocóndricas/enzimología
11.
Hoppe Seylers Z Physiol Chem ; 363(9): 1133-40, 1982 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-6292072

RESUMEN

With a high-resolving dodecyl sulfate electrophoretic system rat liver cytochrome c oxidase was separated into 13 different polypeptides. An antiserum against rat liver holocytochrome c oxidase immunoreacted with all 13 polypeptides, as demonstrated by immunofluorescence after transfer of the separated Coomassie blue-stained bands on nitrocellulose and coupling with FITC-protein A ("western blot"). Polypeptide-specific antisera reacted only with their corresponding polypeptides indicating that the various protein bands are represented by individual polypeptides. From total proteins of rat liver, kidney, heart, spleen and skeletal muscle mitochondria, only the cytochrome c oxidase polypeptides showed immunofluorescence with an antiserum against the rat liver holoenzyme. In contrast to the polypeptide from liver, polypeptide VIa from heart and skeletal muscle showed little or no reactivity, indicating a tissue-specificity of this polypeptide. Mitochondrial proteins from pig, bovine and blackbird heart were incubated with an antiserum against the rat liver holoenzyme. Immunoreaction was found with most cytochrome c oxidase polypeptides but not with polypeptide VIa. This result demonstrates less immunological relationship between tissue-specific polypeptides (VIa, VIIa and VIII) of the same species than between tissue-unspecific polypeptides of different species.


Asunto(s)
Complejo IV de Transporte de Electrones/genética , Riñón/enzimología , Mitocondrias Cardíacas/enzimología , Mitocondrias Hepáticas/enzimología , Mitocondrias Musculares/enzimología , Mitocondrias/enzimología , Bazo/enzimología , Animales , Aves , Bovinos , Técnica del Anticuerpo Fluorescente , Sustancias Macromoleculares , Especificidad de Órganos , Péptidos/análisis , Ratas , Especificidad de la Especie , Porcinos
12.
Anal Biochem ; 129(2): 517-21, 1983 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-6303162

RESUMEN

A sodium dodecyl sulfate-gel electrophoretic procedure which allows the separation of isolated cytochrome c oxidase from different mammalian sources into 13 different polypeptides is described. Application of the silver-staining procedure results in the same protein pattern as obtained by Coomassie blue staining. From the correlation of the gel bands with 12 isolated polypeptides from which the complete amino acid sequence is known, it is concluded that mammalian cytochrome c oxidase consists of 13 different polypeptides which can all be separated by the described procedure.


Asunto(s)
Complejo IV de Transporte de Electrones/análisis , Fragmentos de Péptidos/análisis , Animales , Bovinos , Electroforesis en Gel de Poliacrilamida , Hígado/enzimología , Miocardio/enzimología , Ratas , Dodecil Sulfato de Sodio , Porcinos
13.
Clin Chem ; 44(4): 779-89, 1998 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-9554489

RESUMEN

A homogeneous HDL-c assay (HDL-H), which uses polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin, was assessed for precision, accuracy, and cholesterol and triglyceride interference. In addition, its analytical performance was compared with that of a phosphotungstic acid (PTA)/MgCl2 precipitation method (HDL-P). Within-run CVs were < or = 1.87%; total CVs were < or = 3.08%. Accuracy was evaluated in fresh normotriglyceridemic sera using the Designated Comparison Method (HDL-H = 1.037 Designated Comparison Method + 4 mg/L; n = 63) and in moderately hypertriglyceridemic sera by using the Reference Method (HDL-H = 1.068 Reference Method - 17 mg/L; n = 41). Mean biases were 4.5% and 2.2%, respectively. In hypertriglyceridemic sera (n = 85), HDL-H concentrations were increasingly positively biased with increasing triglyceride concentrations. The method comparison between HDL-H and HDL-P yielded the following equation: HDL-H = 1.037 HDL-P + 15 mg/L; n = 478. We conclude that HDL-H amply meets the 1998 NCEP recommendations for total error; its precision is superior compared with that of HDL-P, and its average bias remains below +/-5% as long as triglyceride concentrations are < or = 10 g/L and in case of moderate hypercholesterolemia.


Asunto(s)
HDL-Colesterol/sangre , Triglicéridos/sangre , Precipitación Química , Colesterol/sangre , Colesterol Oxidasa , Ciclodextrinas , Humanos , Hiperlipidemias/sangre , Cloruro de Magnesio , Ácido Fosfotúngstico , Polietilenglicoles , Estándares de Referencia , Análisis de Regresión , Esterol Esterasa , Ultracentrifugación
14.
Clin Chem ; 43(1): 92-9, 1997 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8990228

RESUMEN

A new turbidimetric inhibition immunoassay for digoxin (Tina-quant [a] Digoxin, Boehringer Mannheim) was evaluated in seven laboratories. It can be performed without sample pretreatment with ready-to-use reagents on nondedicated analyzers in combination with routine clinical chemistry. The studies revealed a good analytical performance: lower limit of detection 0.12 microg/L (3 SD from mean of blank); linearity up to 7.5 microg/L; median between-run CVs 8.1% (0.6 microg/L), 2.8% (1.5 microg/L), 1.9% (3 microg/L); mean analytical recovery in control sera 98-102%; slopes from 0.97 to 1.09 and intercepts from -0.28 to 0.10 microg/L in comparison with four immunoassays; and a high resistance to common interferents. The test was more resistant to digoxin-like immunoreactive factor (DLIF) interference than other methods, showing cross-reactivity only in some intensive care patient samples. Among 192 patients in whom DLIF is expected (e.g., pregnant women, patients with renal failure, newborns), 90% of results were < or =0.26 microg/L digoxin. Cortisol showed no cross-reactivity and digoxigenin had a low reactivity. An interlaboratory survey revealed a good comparability of the Tina-quant [a] test with the median of all methods (slope 0.99, intercept -0.06 microg/L). An HPLC method for digoxin based on isocratic separation of samples on an RP-18 column followed by detection by an immunoassay yielded a reasonable comparability with the immunochemical tests with noncritical samples. Divergent results of immunoassays caused by DLIFs or different cross-reactivities with digoxin metabolites or derivatives can be explained by the use of this HPLC method.


Asunto(s)
Cromatografía Líquida de Alta Presión , Digoxina/sangre , Inmunoensayo/métodos , Nefelometría y Turbidimetría/métodos , Anticoagulantes , Cuidados Críticos , Femenino , Humanos , Inmunoensayo/estadística & datos numéricos , Indicadores y Reactivos , Recién Nacido , Laboratorios , Embarazo , Control de Calidad , Valores de Referencia , Diálisis Renal , Insuficiencia Renal/sangre , Sensibilidad y Especificidad
15.
Clin Chem ; 43(9): 1622-9, 1997 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9299943

RESUMEN

We evaluated a new homogeneous assay for the measurement of HDL-cholesterol (HDL-C) in six European laboratories. The assay includes two reagents and is applicable to most autoanalyzers, which allows full automation. The total CVs of the new method ranged between 1.3% and 6.7%. Thereby determined HDL-C values were in good agreement with those obtained by precipitation with phosphotungstic acid/MgCl2 or by a combination of ultracentrifugation and precipitation (0.956 < r < 0.994). The assay was linear up to at least 1500 mg/L HDL-C. Hemoglobin did not interfere, whereas icteric samples with bilirubin > 100 mg/L showed discrepancies between the homogeneous and the precipitation assay. Lipemia up to total triglyceride concentrations of 8000 mg/L did not interfere with the homogeneous HDL-C assay. The homogeneous HDL-C assay was easy to handle and produced similar results in all laboratories participating in this study. This method will significantly facilitate the screening of individuals at increased risk for cardiovascular disease.


Asunto(s)
HDL-Colesterol/sangre , Artefactos , Autoanálisis/instrumentación , Autoanálisis/métodos , Recolección de Muestras de Sangre/métodos , Precipitación Química , Colesterol/sangre , HDL-Colesterol/aislamiento & purificación , LDL-Colesterol/sangre , Europa (Continente) , Hemoglobinas , Humanos , Indicadores y Reactivos , Laboratorios/normas , Control de Calidad , Valores de Referencia , Análisis de Regresión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Triglicéridos/sangre , Ultracentrifugación
16.
Clin Chem Lab Med ; 37(11-12): 1067-76, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10726814

RESUMEN

We evaluated a new liquid homogeneous assay for the direct measurement of high density lipoprotein cholesterol (HDL-C Plus) in seven laboratories. The assay includes two reagents which can be readily used in most available clinical chemistry analyzers. The total CVs of the new method were below 4.6% and the bias in relation to the designated comparison method was below 3.9%. The total error ranged between 4 to 7%. HDL-C values determined by this method were in good agreement with those obtained by the old homogeneous assay using lyophilized reagents, and other homogeneous and precipitation assays (0.944 < r < 0.996). The assay was linear up to at least 3.89 mmol/l HDL-C. Hemoglobin did not interfere, whereas in icteric samples slight deviations were observed. Lipemia up to 11.3 to 22.6 mmol/l triglycerides did not interfere with this homogeneous HDL-C assay. In samples of patients with paraproteinemia, discrepant results were seen. This liquid homogeneous HDL-C assay was easy to handle and produced similar results in all laboratories participating in this study. This method will enable clinical laboratories to reliably measure HDL-C for risk assessment of coronary heart disease.


Asunto(s)
HDL-Colesterol/sangre , Pruebas de Química Clínica/métodos , Artefactos , Pruebas de Química Clínica/normas , Europa (Continente) , Humanos , Laboratorios , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA