Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 21(17)2021 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-34502682

RESUMEN

The power industry is in the process of grid modernization with the introduction of phasor measurement units (PMUs), advanced metering infrastructure (AMI), and other technologies. Although these technologies enable more reliable and efficient operation, the risk of cyber threats has increased, as evidenced by the recent blackouts in Ukraine and New York. One of these threats is false data injection attacks (FDIAs). Most of the FDIA literature focuses on the vulnerability of DC estimators and AC estimators to such attacks. This paper investigates FDIAs for PMU-based state estimation, where the PMUs are comparable. Several states can be manipulated by compromising one PMU through the channels of that PMU. A Phase Locking Value (PLV) technique was developed to detect FDIAs. The proposed approach is tested on the IEEE 14-bus and the IEEE 30-bus test systems under different scenarios using a Monte Carlo simulation where the PLV demonstrated an efficient performance.


Asunto(s)
Industrias , Tecnología , Simulación por Computador
2.
Micromachines (Basel) ; 11(6)2020 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-32570813

RESUMEN

Gas sensors are critical components when adhering to health safety and environmental policies in various manufacturing industries, such as the petroleum and oil industry; scent and makeup production; food and beverage manufacturing; chemical engineering; pollution monitoring. In recent times, gas sensors have been introduced to medical diagnostics, bioprocesses, and plant disease diagnosis processes. There could be an adverse impact on human health due to the mixture of various gases (e.g., acetone (A), ethanol (E), propane (P)) that vent out from industrial areas. Therefore, it is important to accurately detect and differentiate such gases. Towards this goal, this paper presents a novel electronic nose (e-nose) detection method to classify various explosive gases. To detect explosive gases, metal oxide semiconductor (MOS) sensors are used as reliable tools to detect such volatile gases. The data received from MOS sensors are processed through a multivariate analysis technique to classify different categories of gases. Multivariate analysis was done using three variants-differential, relative, and fractional analyses-in principal components analysis (PCA). The MOS sensors also have three different designs: loading design, notch design, and Bi design. The proposed MOS sensor-based e-nose accurately detects and classifies three different gases, which indicates the reliability and practicality of the developed system. The developed system enables discrimination of these gases from the mixture. Based on the results from the proposed system, authorities can take preventive measures to deal with these gases to avoid their potential adverse impacts on employee health.

3.
J Neurosci Methods ; 325: 108317, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31302155

RESUMEN

BACKGROUND: This study addresses an ongoing debate, i.e. whether microstates have a relation to specific oscillations or frequency bands. The previous literature on this has been inconclusive. Due to stochastic calculation of microstates it is important to address this issue because instead of providing further insights, it might lead us to ambiguous interpretations. NEW METHOD: Here we propose a new method that allows to remove the time-frequency trade-off, which hampered previous works, using Empirical Mode Decomposition (EMD) and the AM-FM model. The method is applied to two resting-state EEG datasets. RESULTS: First, our analysis confirmed that, indeed, when overlooking time-dependence in frequency domain, the results are inconclusive and consequently, highlighted the importance of preserving time-information in the spectral domain. Second, it is confirmed using synthetic data that the local peaks in global field potential (GFP) waveform are influenced by spectral powers present in composite signals. Based on synthetic results, it is inferred that in our dataset, an average frequency range of 10-15 Hz dominates the formation and the temporal dynamics of microstates. Third, it is shown that multiple overlapping patterns of synchronized activities described by a single meta-process in full band microstate studies can be identified using the proposed frequency-band subdivision. The results are consistent across both datasets. CONCLUSION: This study opens several new ventures to be explored in the future: e.g. analysis of temporally overlapping patterns described so far by single topographic patterns, which we show to be spectrally differentiable via band-wise topographic segmentation proposed in the present study.


Asunto(s)
Ondas Encefálicas/fisiología , Corteza Cerebral/fisiología , Electroencefalografía/métodos , Neuroimagen Funcional/métodos , Adulto , Femenino , Humanos , Masculino
4.
J Neurosci Methods ; 291: 150-165, 2017 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-28842191

RESUMEN

BACKGROUND: Simultaneous electroencephalography (EEG) and functional magnetic resonance image (fMRI) acquisitions provide better insight into brain dynamics. Some artefacts due to simultaneous acquisition pose a threat to the quality of the data. One such problematic artefact is the ballistocardiogram (BCG) artefact. METHODS: We developed a hybrid algorithm that combines features of empirical mode decomposition (EMD) with principal component analysis (PCA) to reduce the BCG artefact. The algorithm does not require extra electrocardiogram (ECG) or electrooculogram (EOG) recordings to extract the BCG artefact. RESULTS: The method was tested with both simulated and real EEG data of 11 participants. From the simulated data, the similarity index between the extracted BCG and the simulated BCG showed the effectiveness of the proposed method in BCG removal. On the other hand, real data were recorded with two conditions, i.e. resting state (eyes closed dataset) and task influenced (event-related potentials (ERPs) dataset). Using qualitative (visual inspection) and quantitative (similarity index, improved normalized power spectrum (INPS) ratio, power spectrum, sample entropy (SE)) evaluation parameters, the assessment results showed that the proposed method can efficiently reduce the BCG artefact while preserving the neuronal signals. COMPARISON WITH EXISTING METHODS: Compared with conventional methods, namely, average artefact subtraction (AAS), optimal basis set (OBS) and combined independent component analysis and principal component analysis (ICA-PCA), the statistical analyses of the results showed that the proposed method has better performance, and the differences were significant for all quantitative parameters except for the power and sample entropy. CONCLUSIONS: The proposed method does not require any reference signal, prior information or assumption to extract the BCG artefact. It will be very useful in circumstances where the reference signal is not available.


Asunto(s)
Algoritmos , Artefactos , Electroencefalografía/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Adulto , Análisis de Varianza , Atención/fisiología , Simulación por Computador , Potenciales Evocados , Corazón/fisiología , Humanos , Modelos Neurológicos , Percepción de Movimiento/fisiología , Pruebas Neuropsicológicas , Análisis de Componente Principal , Descanso , Percepción Visual/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA