Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 174
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38742491

RESUMEN

BACKGROUND: Diffuse coronary artery disease (CAD) impacts the safety and efficacy of percutaneous coronary intervention (PCI). Pathophysiological CAD patterns can be quantified using fractional flow reserve (FFR) pullbacks incorporating the pullback pressure gradient (PPG) calculation. This study aimed to establish the capacity of PPG to predict optimal revascularisation and procedural outcomes. METHODS: This prospective, investigator-initiated, single-arm, multicentre study enrolled patients with at least one epicardial lesion with an FFR ≤ 0.80 scheduled for PCI. Manual FFR pullbacks were employed to calculate PPG. The primary outcome of optimal revascularisation was defined as a post-PCI FFR ≥ 0.88. RESULTS: 993 patients with 1044 vessels were included. The mean FFR was 0.68 ± 0.12, PPG 0.62 ± 0.17, and post-PCI FFR 0.87 ± 0.07. PPG was significantly correlated with the change in FFR after PCI (r=0.65, 95% CI 0.61-0.69, p<0.001) and demonstrated excellent predicted capacity for optimal revascularisation (AUC 0.82, 95% CI 0.79-0.84, p<0.001). Conversely, FFR alone did not predict revascularisation outcomes (AUC 0.54, 95% CI 0.50-0.57). PPG influenced treatment decisions in 14% of patients, redirecting them from PCI to alternative treatment modalities. Periprocedural myocardial infarction occurred more frequently in patients with low PPG (<0.62) compared to those with focal disease (OR 1.71, 95% CI: 1.00-2.97). CONCLUSIONS: Pathophysiological CAD patterns distinctly affect the safety and effectiveness of PCI. The PPG showed an excellent predictive capacity for optimal revascularisation and demonstrated added value compared to a FFR measurement.

2.
Eur Heart J ; 45(3): 181-194, 2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-37634192

RESUMEN

BACKGROUND AND AIMS: Coronary flow capacity (CFC) is associated with an observed 10-year survival probability for individual patients before and after actual revascularization for comparison to virtual hypothetical ideal complete revascularization. METHODS: Stress myocardial perfusion (mL/min/g) and coronary flow reserve (CFR) per pixel were quantified in 6979 coronary artery disease (CAD) subjects using Rb-82 positron emission tomography (PET) for CFC maps of artery-specific size-severity abnormalities expressed as percent left ventricle with prospective follow-up to define survival probability per-decade as fraction of 1.0. RESULTS: Severely reduced CFC in 6979 subjects predicted low survival probability that improved by 42% after revascularization compared with no revascularization for comparable severity (P = .0015). For 283 pre-and-post-procedure PET pairs, severely reduced regional CFC-associated survival probability improved heterogeneously after revascularization (P < .001), more so after bypass surgery than percutaneous coronary interventions (P < .001) but normalized in only 5.7%; non-severe baseline CFC or survival probability did not improve compared with severe CFC (P = .00001). Observed CFC-associated survival probability after actual revascularization was lower than virtual ideal hypothetical complete post-revascularization survival probability due to residual CAD or failed revascularization (P < .001) unrelated to gender or microvascular dysfunction. Severely reduced CFC in 2552 post-revascularization subjects associated with low survival probability also improved after repeat revascularization compared with no repeat procedures (P = .025). CONCLUSIONS: Severely reduced CFC and associated observed survival probability improved after first and repeat revascularization compared with no revascularization for comparable CFC severity. Non-severe CFC showed no benefit. Discordance between observed actual and virtual hypothetical post-revascularization survival probability revealed residual CAD or failed revascularization.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Radioisótopos de Rubidio , Estudios Prospectivos , Tomografía de Emisión de Positrones/métodos , Angiografía Coronaria/métodos
3.
J Nucl Cardiol ; : 101884, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38761831

RESUMEN

BACKGROUND: Data on cardiac positron emission tomography (PET) in liver transplantation (LT) candidates are limited with no prior study accounting for poorly metabolized caffeine reducing stress perfusion. METHOD: Consecutive LT candidates (n = 114) undergoing cardiac rest/stress PET were instructed to abstain from caffeine for 2 days extended to 5 and 7 days. Due to persistently high prevalence of measurable blood caffeine after 5-day caffeine abstinence, dipyridamole (n = 41) initially used was changed to dobutamine (n = 73). Associations of absolute flow, coronary flow reserve (CFR), detectable blood caffeine, and Modified End-Stage Liver Disease (MELD) score for liver failure severity were evaluated. Coronary flow data of LT candidates were compared to non-LT control group (n = 102 for dipyridamole, n = 29 for dobutamine). RESULTS: Prevalence of patients with detectable blood caffeine was 63.3%, 36.7% and 33.3% after 2-, 5- and 7-day of caffeine abstinence, respectively. MELD score was associated with detectable caffeine (odd ratio 1.18,P < 0.001). CFR was higher during dipyridamole stress without-caffeine versus with-caffeine (2.22 ± 0.80 vs 1.55 ± 0.37,P = 0.048) but lower than dobutamine stress (2.22 ± 0.80 vs 2.82 ± 1.02,P = 0.026). Mediation analysis suggested that the dominant association between CFR and MELD score in dipyridamole group derived from caffeine-impaired CFR and liver failure/caffeine interaction. CFR in LT candidates was lower than non-LT control population in both dipyridamole and dobutamine group. CONCLUSION: We demonstrate exceptionally high prevalence of detectable blood caffeine in LT candidates undergoing stress PET myocardial perfusion imaging resulting in reduced CFR with dipyridamole compared to dobutamine. The delayed caffeine clearance in LT candidates makes dobutamine a preferred stress agent in this population.

4.
Eur Heart J ; 44(30): 2805-2814, 2023 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-37264699

RESUMEN

The colorful term "coronary steal" arose in 1967 to parallel "subclavian steal" coined in an anonymous 1961 editorial. In both instances, the word "steal" described flow reversal in the setting of an interconnected but abnormal vascular network-in one case a left subclavian stenosis proximal to the origin of the vertebral artery and in the other case a coronary fistula. Over time, the term has morphed to include a larger set of pathophysiology without explicit flow reversal but rather with a decrease in stress flow due to other mechanisms. This review aims to shed light on this phenomenon from a clinical and a pathophysiological perspective, detailing the anatomical and physiological conditions that allow so-called steal to appear and offering treatment options for six distinct scenarios.


Asunto(s)
Enfermedad de la Arteria Coronaria , Síndrome de Robo Coronario-Subclavio , Síndrome del Robo de la Subclavia , Humanos , Arteria Vertebral , Corazón
5.
Am Heart J ; 265: 170-179, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37611857

RESUMEN

INTRODUCTION: Diffuse disease has been identified as one of the main reasons leading to low post-PCI fractional flow reserve (FFR) and residual angina after PCI. Coronary pressure pullbacks allow for the evaluation of hemodynamic coronary artery disease (CAD) patterns. The pullback pressure gradient (PPG) is a novel metric that quantifies the distribution and magnitude of pressure losses along the coronary artery in a focal-to-diffuse continuum. AIM: The primary objective is to determine the predictive capacity of the PPG for post-PCI FFR. METHODS: This prospective, large-scale, controlled, investigator-initiated, multicenter study is enrolling patients with at least 1 lesion in a major epicardial vessel with a distal FFR ≤ 0.80 intended to be treated by PCI. The study will include 982 subjects. A standardized physiological assessment will be performed pre-PCI, including the online calculation of PPG from FFR pullbacks performed manually. PPG quantifies the CAD pattern by combining several parameters from the FFR pullback curve. Post-PCI physiology will be recorded using a standardized protocol with FFR pullbacks. We hypothesize that PPG will predict optimal PCI results (post-PCI FFR ≥ 0.88) with an area under the ROC curve (AUC) ≥ 0.80. Secondary objectives include patient-reported and clinical outcomes in patients with focal vs. diffuse CAD defined by the PPG. Clinical follow-up will be collected for up to 36 months, and an independent clinical event committee will adjudicate events. RESULTS: Recruitment is ongoing and is expected to be completed in the second half of 2023. CONCLUSION: This international, large-scale, prospective study with pre-specified powered hypotheses will determine the ability of the preprocedural PPG index to predict optimal revascularization assessed by post-PCI FFR. In addition, it will evaluate the impact of PPG on treatment decisions and the predictive performance of PPG for angina relief and clinical outcomes.

6.
J Nucl Cardiol ; 30(4): 1528-1539, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36639611

RESUMEN

BACKGROUND: Data on impact of financial hardship on coronary artery disease (CAD) remain incomplete. METHODS: Consecutive subjects referred for clinical rest/stress cardiac positron emission tomography (PET) were enrolled. Financial hardship is defined as patients' inability to pay for their out-of-pocket expense for cardiac PET. Abnormal cardiac PET is defined as at least moderate relative perfusion defects at stress involving > 10% of the left ventricle or global coronary flow reserve ≤ 2.0. Patients were followed for major adverse cardiovascular event (MACE) comprised of all-cause mortality, non-fatal myocardial infarction, and late coronary revascularization. RESULTS: We analyzed a total of 4173 patients with mean age 65.6 ± 11.3 years, 72.2% men, and 93.6% reported as having medical insurance. Of these, 504 (12.1%) patients had financial hardship. On multivariable analysis, financial hardship associated with abnormal cardiac PET (odds ratio 1.377, p = 0.004) and MACE (hazard ratio 1.432, p = 0.010) and its association with MACE was mostly through direct effect with small proportion mediated by abnormal cardiac PET or known CAD. CONCLUSION: Among patients referred for cardiac rest/stress PET, financial hardship independently associates with myocardial perfusion abnormalities and MACE; however, its effect on MACE is largely not mediated by abnormal myocardial perfusion or known CAD suggesting distinct impact of financial hardship beyond traditional risk factors and CAD that deserves attention and intervention to effectively reduced adverse outcomes. Having medical insurance does not consistently protect from financial hardship and a more preventive-oriented restructuring may provide better outcomes at lower cost.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Imagen de Perfusión Miocárdica , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Estrés Financiero , Tomografía Computarizada por Rayos X , Enfermedad de la Arteria Coronaria/complicaciones , Infarto del Miocardio/complicaciones , Tomografía de Emisión de Positrones , Pronóstico
7.
Catheter Cardiovasc Interv ; 99(5): 1518-1525, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35233906

RESUMEN

Fractional flow reserve (FFR) pullbacks assess the location and magnitude of pressure drops along the coronary artery. The pullback pressure gradient (PPG) quantifies the FFR pullback curve and provides a numeric expression of focal versus diffuse coronary artery disease. This study aims (1) to validate the PPG using manual FFR pullbacks compared with motorized FFR pullbacks as a reference; and (2) to determine the intra- and interoperator reproducibility of the PPG derived from manual FFR pullbacks. Patients with stable coronary artery disease and an FFR ≤ 0.80 were included. All patients underwent FFR pullback evaluation either with a motorized device or manually, depending on the study cohort. The agreement of the PPG between repeated pullbacks was assessed using the Bland-Altman method. Overall, 116 FFR pullback maneuvers (96 manual and 20 motorized) were analyzed. There was excellent agreement between the PPG derived from manual and motorized pullbacks (mean difference -0.01 ± 0.07, 95% limits of agreement [LOA] -0.14 to 0.12). The intra- and interoperator reproducibility of PPG derived from manual pullbacks were excellent (mean difference <0.01, 95% LOA -0.11 to 0.12, and mean difference <0.01, 95% LOA -0.12 to 0.11, respectively). The duration of the pullback maneuver did not impact the reproducibility of the PPG (r = 0.12, 95% CI: -0.29 to 0.49, p = 0.567). Manual pullbacks allow for an accurate PPG calculation. The inter- and intraoperator reproducibility of PPG derived from manual pullbacks were excellent.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Resultado del Tratamiento
8.
Medicina (Kaunas) ; 58(7)2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35888603

RESUMEN

Background and Objectives: Cancer and coronary artery disease (CAD) often coexist. Compared to quantitative coronary angiography (QCA), fractional flow reserve (FFR) has emerged as a more reliable method of identifying significant coronary stenoses. We aimed to assess the specific management, safety and outcomes of FFR-guided percutaneous coronary intervention (PCI) in cancer patients with stable CAD. Materials and Methods: FFR was used to assess cancer patients that underwent coronary angiography for stable CAD between September 2008 and May 2016, and were found to have ≥50% stenosis by QCA. Patients with lesions with an FFR > 0.75 received medical therapy alone, while those with FFR ≤ 0.75 were revascularized. Procedure-related complications, all-cause mortality, nonfatal myocardial infarction, or urgent revascularizations were analyzed. Results: Fifty-seven patients with stable CAD underwent FFR on 57 lesions. Out of 31 patients with ≥70% stenosis as measured by QCA, 14 (45.1%) had an FFR ≥ 0.75 and lesions were reclassified as moderate and did not receive PCI nor DAPT. Out of 26 patients with <70% stenosis as measured by QCA, 6 (23%) had an FFR < 0.75 and were reclassified as severe and were treated with PCI and associated DAPT. No periprocedural complications, urgent revascularization, acute coronary syndromes, or cardiovascular deaths were noted. There was a 22.8% mortality at 1 year, all cancer related. Patients who received a stent by FFR assessment showed a significant association with decreased risk of all-cause death (HR: 0.37, 95% CI 0.15−0.90, p = 0.03). Conclusions: Further studies are needed to define the optimal therapeutic approach for cancer patients with CAD. Using an FFR cut-off point of 0.75 to guide PCI translates into fewer interventions and can facilitate cancer care. There was an overall reduction in mortality in patients that received a stent, suggesting increased resilience to cancer therapy and progression.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Neoplasias , Intervención Coronaria Percutánea , Constricción Patológica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Estenosis Coronaria/complicaciones , Estenosis Coronaria/cirugía , Estudios de Seguimiento , Humanos , Neoplasias/complicaciones , Neoplasias/tratamiento farmacológico , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Resultado del Tratamiento
9.
Am Heart J ; 237: 135-146, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33762179

RESUMEN

BACKGROUND: The literature reports no randomized trial in chronic coronary artery disease (CAD) of a comprehensive management strategy integrating intense lifestyle management, maximal medical treatment to specific goals and high precision quantitative cardiac positron emission tomography (PET) for identifying high mortality risk patients needing essential invasive procedures. We hypothesize that this comprehensive strategy achieves greater risk factor reduction, lower major adverse cardiovascular events and fewer invasive procedures than standard practice. METHODS: The CENTURY Study (NCT00756379) is a randomized-controlled-trial study in patients with stable or at high risk for CAD. Patients are randomized to standard of care (Standard group) or intense comprehensive lifestyle-medical treatment to targets and PET guided interventions (Comprehensive group). Comprehensive Group patients are regularly consulted by the CENTURY team implementing diet/lifestyle/exercise program and medical treatment to target risk modification. Cardiac PET at baseline, 24-, and 60-months quantify the physiologic severity of CAD and guide interventions in the Comprehensive group while patients and referring physicians of the Standard group are blinded to PET results. The primary end-point is the CENTURY risk score reduction during 5 years follow-up. The secondary endpoint is a composite of death, non-fatal myocardial infarction, stroke, and coronary revascularization. CONCLUSIONS: The CENTURY Study is the first study in stable CAD to test the incremental benefit of a comprehensive strategy integrating intense lifestyle modification, medical treatment to specific goals, and high-precision quantitative myocardial perfusion imaging to guide revascularization. A total of 1028 patients have been randomized, and the 5 years follow-up will conclude in 2022.


Asunto(s)
Terapia Conductista/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Circulación Coronaria/fisiología , Estilo de Vida , Tomografía de Emisión de Positrones/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
10.
Am Heart J ; 222: 139-146, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32062172

RESUMEN

BACKGROUND: It remains uncertain if invasive coronary physiology beyond fractional flow reserve (FFR) can refine lesion selection for revascularization or provide additional prognostic value. Coronary flow reserve (CFR) equals the ratio of hyperemic to baseline flow velocity and has a wealth of invasive and noninvasive data supporting its validity. Because of fundamental physiologic relationships, binary classification of FFR and CFR disagrees in approximately 30%-40% of cases. Optimal management of these discordant cases requires further study. AIM: The aim of the study was to determine the prognostic value of combined FFR and CFR measurements to predict the 24-month rate of major adverse cardiac events. Secondary end points include repeatability of FFR and CFR, angina burden, and the percentage of successful FFR/CFR measurements which will not be excluded by the core laboratory. METHODS: This prospective, nonblinded, nonrandomized, and multicenter study enrolled 455 subjects from 12 sites in Europe and Japan. Patients underwent physiologic lesion assessment using the 0.014" Philips Volcano ComboWire XT that provides simultaneous pressure and Doppler velocity sensors. Intermediate coronary lesions received only medical treatment unless both FFR (≤0.8) and CFR (<2.0) were below thresholds. The primary outcome is a 24-month composite of death from any cause, myocardial infarction, and revascularization. CONCLUSION: The DEFINE-FLOW study will determine the prognostic value of invasive CFR assessment when measured simultaneously with FFR, with a special emphasis on discordant classifications. Our hypothesis is that lesions with an intact CFR ≥ 2.0 but reduced FFR ≤ 0.8 will have a 2-year outcome with medical treatment similar to lesions with FFR> 0.80 and CFR ≥ 2.0. Enrollment has been completed, and final follow-up will occur in November 2019.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Estenosis Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Monitoreo Fisiológico/instrumentación , Anciano , Cateterismo Cardíaco/métodos , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
11.
Catheter Cardiovasc Interv ; 96(3): E268-E277, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32077561

RESUMEN

OBJECTIVES: We sought to develop an automatic method for correcting common errors in phasic pressure tracings for physiology-guided interventions on coronary and valvular stenosis. BACKGROUND: Effective coronary and valvular interventions rely on accurate hemodynamic assessment. Phasic (subcycle) indexes remain intrinsic to valvular stenosis and are emerging for coronary stenosis. Errors, corrections, and clinical implications of fluid-filled catheter phasic pressure assessments have not been assessed in the current era of ubiquitous, high-fidelity pressure wire sensors. METHODS: We recruited patients undergoing invasive coronary physiology assessment. Phasic aortic pressure signals were recorded simultaneously using a fluid-filled guide catheter and 0.014″ pressure wire before and after standard calibration as well as after pullback. We included additional subjects undergoing hemodynamic assessment before and after transcatheter aortic valve implantation. Using the pressure wire as reference standard, we developed an automatic algorithm to match phasic pressures. RESULTS: Removing pressure offset and temporal shift produced the largest improvements in root mean square (RMS) error between catheter and pressure wire signals. However, further optimization <1 mmHg RMS error was possible by accounting for differential gain and the oscillatory behavior of the fluid-filled guide. The impact of correction was larger for subcycle (like systole or diastole) versus whole-cycle metrics, indicating a key role for valvular stenosis and emerging coronary pressure ratios. CONCLUSIONS: When calibrating phasic aortic pressure signals using a pressure wire, correction requires these parameters: offset, timing, gain, and oscillations (frequency and damping factor). Automatically eliminating common errors may improve some clinical decisions regarding physiology-based intervention.


Asunto(s)
Aorta/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Presión Arterial , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Estenosis Coronaria/diagnóstico , Transductores de Presión , Anciano , Algoritmos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/terapia , Automatización , Calibración , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/normas , Catéteres Cardíacos/normas , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Transductores de Presión/normas
12.
J Interv Cardiol ; 2020: 4603169, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32774184

RESUMEN

With the increasing prevalence of aortic stenosis (AS) due to a growing elderly population, a proper understanding of its physiology is paramount to guide therapy and define severity. A better understanding of the microvasculature in AS could improve clinical care by predicting left ventricular remodeling or anticipate the interplay between epicardial stenosis and myocardial dysfunction. In this review, we combine five decades of literature regarding microvascular, coronary, and aortic valve physiology with emerging insights from newly developed invasive tools for quantifying microcirculatory function. Furthermore, we describe the coupling between microcirculation and epicardial stenosis, which is currently under investigation in several randomized trials enrolling subjects with concomitant AS and coronary disease. To clarify the physiology explained previously, we present two instructive cases with invasive pressure measurements quantifying coexisting valve and coronary stenoses. Finally, we pose open clinical and research questions whose answers would further expand our knowledge of microvascular dysfunction in AS. These trials were registered with NCT03042104, NCT03094143, and NCT02436655.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Circulación Coronaria , Microcirculación/fisiología , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Manejo de la Enfermedad , Humanos
13.
J Nucl Cardiol ; 27(2): 386-396, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32095938

RESUMEN

BACKGROUND: PET quantitative myocardial perfusion requires correction for partial volume loss due to one-dimensional LV wall thickness smaller than scanner resolution. METHODS: We aimed to assess accuracy of risk stratification for death, MI, or revascularization after PET using partial volume corrections derived from two-dimensional ACR and three-dimensional NEMA phantoms for 3987 diagnostic rest-stress perfusion PETs and 187 MACE events. NEMA, ACR, and Tree phantoms were imaged with Rb-82 or F-18 for size-dependent partial volume loss. Perfusion and Coronary Flow Capacity were recalculated using different ACR- and NEMA-derived partial volume corrections compared by Kolmogorov-Smirnov statistics to standard perfusion metrics with established correlations with MACE. RESULTS: Partial volume corrections based on two-dimensional ACR rods (two equal radii) and three-dimensional NEMA spheres (three equal radii) over estimate partial volume corrections, quantitative perfusion, and Coronary Flow Capacity by 50% to 150% over perfusion metrics with one-dimensional partial volume correction, thereby substantially impairing correct risk stratification. CONCLUSIONS: ACR (2-dimensional) and NEMA (3-dimensional) phantoms overestimate partial volume corrections for 1-dimensional LV wall thickness and myocardial perfusion that are corrected with a simple equation that correlates with MACE for optimal risk stratification applicable to most PET-CT scanners for quantifying myocardial perfusion.


Asunto(s)
Cardiología/normas , Ventrículos Cardíacos/diagnóstico por imagen , Corazón/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Humanos , Imagen de Perfusión Miocárdica , Miocardio/patología , Perfusión , Fantasmas de Imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Reproducibilidad de los Resultados , Riesgo , Radioisótopos de Rubidio
14.
Curr Cardiol Rep ; 22(4): 20, 2020 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-32052198

RESUMEN

PURPOSE OF REVIEW: This review discusses similarities and differences between cardiac positron emission tomography (PET), absolute myocardial blood flow, and flow reserve with invasive fractional flow reserve (FFR). RECENT FINDINGS: Fundamentally, cardiac PET measures absolute myocardial blood flow whereas FFR provides a relative flow reserve. Cardiac PET offers a non-invasive and therefore lower risk alternative, able to image the entire left ventricle regardless of coronary anatomy. While cardiac PET can provide unique information about the subendocardium, FFR pullbacks offer unparalleled spatial resolution. Both diagnostic tests provide a highly repeatable and technically successful index of coronary hemodynamics that accounts for the amount of distal myocardial mass, albeit only indirectly with FFR. The randomized evidence base for FFR and its associated cost effectiveness remains unsurpassed. Cardiac PET and FFR have been intertwined since the very development of FFR over 25 years ago. Recent work has emphasized the ability of both techniques to guide revascularization decisions by high-quality physiology. In the past few years, cardiac PET has expanded its evidence base regarding clinical outcomes, whereas FFR has solidified its position in randomized studies as the invasive reference standard.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Hemodinámica/fisiología , Tomografía de Emisión de Positrones/métodos , Función Ventricular Izquierda/fisiología , Angiografía Coronaria/métodos , Humanos , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
15.
Eur Heart J ; 40(31): 2585-2594, 2019 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-31329863

RESUMEN

AIMS: The instantaneous wave-free ratio (iFR) and whole-cycle Pd/Pa investigate coronary physiology during non-hyperaemic conditions. To test for unique physiologic properties of the wave-free period when making resting coronary pressure measurements, we compared post hoc a diastolic pressure ratio (dPR) and Pd/Pa against iFR for numerical similarity and test/retest repeatability. METHODS AND RESULTS: Eight hundred and ninety-three lesions from 833 subjects were included from the VERIFY 2 and CONTRAST studies. Diastolic pressure ratio and a linear transform of Pd/Pa were compared against iFR for diagnostic performance. Mean difference between dPR and iFR [Δ = -0.006 ± 0.011, r2 = 0.993, area under receiver operating characteristic (ROC) curve (AUC) = 0.997] mirrored the difference of two iFR measurements repeated immediately (Δ = <0.001 ± 0.004, r2 = 0.998, AUC = 1.00). Minor variations in the definition of dPR changed its value by <1-2% over a broad range of the cardiac cycle. A linear transform of Pd/Pa showed very good diagnostic performance (Δ = -0.012 ± 0.031, r2 = 0.927, AUC = 0.979). Post hoc iFR values were validated against real-time iFR values and matched almost exactly (average Δ = <0.001 ± 0.004, 99.6% within ±0.01). CONCLUSIONS: Our dPR offers numerical equivalency to iFR. Despite different technical approaches for identifying the relevant period of diastole, the agreement between dPR and iFR and the insensitivity of dPR to minor variations in its definition further confirm numerical equivalency among resting metrics.


Asunto(s)
Presión Sanguínea/fisiología , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiología , Infarto del Miocardio/fisiopatología , Descanso/fisiología , Anciano , Algoritmos , Estudios de Casos y Controles , Cateterismo/métodos , Cateterismo/tendencias , Enfermedad de la Arteria Coronaria/cirugía , Electrocardiografía/métodos , Femenino , Corazón/fisiología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Estudios Retrospectivos
16.
Eur Heart J ; 40(2): 180-186, 2019 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-30596995

RESUMEN

Aims: To assess the effect of fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) with contemporary drug-eluting stents on the composite of cardiac death or myocardial infarction (MI) vs. medical therapy in patients with stable coronary lesions. Methods and results: We performed a systematic review and meta-analysis of individual patient data (IPD) of the three available randomized trials of contemporary FFR-guided PCI vs. medical therapy for patients with stable coronary lesions: FAME 2 (NCT01132495), DANAMI-3-PRIMULTI (NCT01960933), and Compare-Acute (NCT01399736). FAME 2 enrolled patients with stable coronary artery disease (CAD), while the other two focused on non-culprit lesions in stabilized patients after acute coronary syndrome. A total of 2400 subjects were recruited from 54 sites world-wide with 1056 randomly assigned to FFR-guided PCI and 1344 to medical therapy. The pre-specified primary outcome was a composite of cardiac death or MI. We included data from extended follow-ups for FAME 2 (up to 5.5 years follow-up) and DANAMI-3-PRIMULTI (up to 4.7 years follow-up). After a median follow-up of 35 months (interquartile range 12-60 months), a reduction in the composite of cardiac death or MI was observed with FFR-guided PCI as compared with medical therapy (hazard ratio 0.72, 95% confidence interval 0.54-0.96; P = 0.02). The difference between groups was driven by MI. Conclusion: In this IPD meta-analysis of the three available randomized controlled trials to date, FFR-guided PCI resulted in a reduction of the composite of cardiac death or MI compared with medical therapy, which was driven by a decreased risk of MI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico/fisiología , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Intervención Coronaria Percutánea/estadística & datos numéricos , Pronóstico , Ensayos Clínicos Controlados Aleatorios como Asunto
17.
Catheter Cardiovasc Interv ; 94(3): 356-363, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30702186

RESUMEN

OBJECTIVES: To identify clinical, angiographic and hemodynamic predictors of discordance between instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR). BACKGROUND: The iFR was found to be non-inferior to the gold-standard FFR for guiding coronary revascularization, although it is discordant with FFR in 20% of cases. A better understanding of the causes of discordance may enhance application of these indices. METHODS: Both FFR and iFR were measured in the prospective multicenter CONTRAST study. Clinical, angiographic and hemodynamic variables were compared between patients with concordant values of FFR and iFR (cutoff ≤0.80 and ≤0.89, respectively). RESULTS: Out of the 587 patients included, in 466 patients (79.4%) FFR and iFR agreed: both negative, n = 244 (41.6%), or positive, n = 222 (37.8%). Compared with FFR, iFR was negative discordant (FFR+/iFR-) in 69 (11.8%) patients and positive discordant (FFR-/iFR+) in 52 (8.9%) patients. On multivariate regression, stenosis location (left main or proximal left anterior descending) (OR: 3.30[1.68;6.47]), more severe stenosis (OR: 1.77[1.35;2.30]), younger age (OR: 0.93[0.90;0.97]), and slower heart rate (OR: 0.59[0.42;0.75]) were predictors of a negative discordant iFR. Absence of a beta-blocker (OR: 0.41[0.22;0.78]), older age (OR: 1.04[1.00;1.07]), and less severe stenosis (OR: 0.69[0.53;0.89]) were predictors of a positive discordant iFR. CONCLUSIONS: During iFR acquisition, stenosis location, stenosis degree, heart rate, age and use of beta blockers influence concordance with FFR and should be taken into account when interpreting iFR.


Asunto(s)
Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Antagonistas Adrenérgicos beta/uso terapéutico , Factores de Edad , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
19.
J Nucl Cardiol ; 26(3): 1007-1014, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30574677

RESUMEN

Pharmacologic reversal of serious or intolerable side effects (SISEs) from vasodilator stress is an important safety and comfort measure for patients experiencing such effects. While typically performed using intravenous aminophylline, recurrent shortages of this agent have led to a greater need to limit its use and consider alternative agents. This information statement provides background and recommendations addressing indications for vasodilator reversal, timing of a reversal agent, incidence of observed SISE with vasodilator stress, clinical and logistical considerations for aminophylline-based reversal, and alternative non-aminophylline based reversal protocols.


Asunto(s)
Aminofilina/uso terapéutico , Cardiotónicos/uso terapéutico , Vasodilatadores/efectos adversos , Aminofilina/provisión & distribución , Cardiotónicos/provisión & distribución , Prueba de Esfuerzo , Humanos , Imagen de Perfusión Miocárdica , Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA