Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(7): 1259-1262, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37855197

RESUMEN

Valve-in-valve transcatheter aortic valve replacement (valve-in-valve TAVR) increases the risk of coronary obstruction. Although the coronary protection strategy is widely used, the use of the bailout technique after coronary obstruction is limited. Hence, we report a simple bailout technique for coronary obstruction after valve-in-valve TAVR. An 82-year-old woman presented with structural valve deterioration. The left anterior descending coronary artery had 90% stenosis. After TAVR, the prosthetic valve shifted close to the ascending aorta wall, consequently impairing coronary flow. The wire crossed with the Judkins right guiding catheter (JR) reference to the en-face and perpendicular views. Using the guide-extension catheter, the JR contacted the contralateral ascending aorta as a backup catheter. After a balloon was dilated between the prosthetic valve and aorta, JR engaged into the coronary artery with excellent backup. This novel "Whisker pole guiding technique" is useful, even after valve-in-valve TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Vasos Coronarios/cirugía , Resultado del Tratamiento , Oclusión Coronaria/cirugía , Catéteres , Factores de Riesgo
2.
BMC Cardiovasc Disord ; 23(1): 281, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37264308

RESUMEN

BACKGROUND: Recent studies have reported atrial involvement and coexistence of aortic stenosis in transthyretin (ATTR) cardiac amyloidosis (CA). However, pathological reports of extraventricular ATTR amyloid deposits in atrial structures or heart valves are limited, and the clinical implications of ATTR amyloid deposits outside the ventricles are not fully elucidated. CASE PRESENTATION: We report 3 cases of extraventricular ATTR amyloid deposits confirmed in surgically resected aortic valves and left atrial structures, all of which were unlikely to have significant ATTR amyloidosis infiltrating the ventricles as determined by multimodality evaluation including 99mtechnetium-pyrophosphate scintigraphy, cardiac magnetic resonance, endomyocardial biopsy and their mid-term clinical course up to 5 years. These findings suggested that these were extraventricular ATTR amyloid deposits localized in the aortic valve and the left atrium. CONCLUSIONS: While long-term observation is required to fully clarify whether these extraventricular ATTR amyloid deposits are truly localized outside the ventricles or are early stages of ATTR-CA infiltrating the ventricles, our 3 cases with multimodality evaluations and mid-term follow up suggest the existence of extraventricular ATTR amyloid deposits localized in the aortic valve and left atrial structures.


Asunto(s)
Neuropatías Amiloides Familiares , Fibrilación Atrial , Cardiomiopatías , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Neuropatías Amiloides Familiares/diagnóstico por imagen , Estudios de Seguimiento , Placa Amiloide , Prealbúmina/genética , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Cardiomiopatías/diagnóstico por imagen
3.
J Artif Organs ; 26(2): 151-155, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35906510

RESUMEN

Implantation of left ventricular assist device (LVAD) for arrhythmogenic right ventricular (RV) cardiomyopathy is challenging associated with small LV cavity, laterally dislocated LV apex, thin and fragile RV free wall. A 43-year-old male with more than 10 years of medical treatment developed congestive heart failure related to biventricular failure. Durable LVAD was indicated to prevent further deterioration of the RV function, which would be exacerbated by progression of LV dysfunction. To simulate surgery, we printed-out a 3D heart model based on enhanced CT scanning study to identify the optimal coring position in the LV apex, by which the inflow directs the mitral valve. We then found that the mini-cuff of the HeartMate3 should be fixed in the paper-thin RV free wall by the usual cuff-sewing method. In the surgery, after the coring as planned, 5 pairs of interrupted sutures on the medial side were passed from the luminal side of the LV and then to the mini-cuff, and the lateral side of the mini-cuff was fixed with a continuous sutures, not to sew into the RV wall. The surgery was completed without complications with a good hemodynamics. The 3D heart model facilitated this unique method, indicating a usefulness of printed-out heart model for cases with unusual cardiac anatomy, which needs implantation of durable LVAD.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Insuficiencia Cardíaca , Corazón Auxiliar , Disfunción Ventricular Izquierda , Disfunción Ventricular Derecha , Masculino , Humanos , Adulto , Displasia Ventricular Derecha Arritmogénica/cirugía , Displasia Ventricular Derecha Arritmogénica/complicaciones , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Disfunción Ventricular Izquierda/complicaciones , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Disfunción Ventricular Derecha/etiología , Función Ventricular Derecha
4.
Circ J ; 87(1): 76-83, 2022 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-35965068

RESUMEN

BACKGROUND: It is unknown whether early atrial tachyarrhythmia (ATA) recurrence occurring within 3 months after the Maze procedure predicts late ATA recurrence.Methods and Results: This study involved 610 patients who underwent the modified Cryo-Maze procedure in conjunction with other cardiac surgery. The primary outcomes were late ATA recurrence, defined as occurring ≥3 months after surgery. The effects of early ATA recurrence on late ATA recurrence were analyzed using a Cox proportional hazards model. The following 11 covariates were considered explanatory variables: early ATA recurrence, age, sex, body surface area, preoperative duration of atrial fibrillation, preoperative left atrial diameter, and concomitant surgery (mitral valve replacement, mitral valve repair, aortic valve replacement, tricuspid annuloplasty, and left atrial appendage closure). Statistical analyses were performed with a 2-sided 5% significance level. Early ATA recurrence occurred in 174 patients (28.5%). Late ATA recurrence occurred in 167 patients (27.5%), with 595 events identified in these patients. The Cox proportional hazards model showed that early ATA recurrence was an independent predictor of late ATA recurrence (hazard ratio, 4.14; 95% confidence interval, 3.00-5.70; P<0.001)Conclusions: Early ATA recurrence was an independent predictor of late ATA recurrence among patients undergoing the modified Cryo-Maze procedure. The blanking period might not be applied to patients undergoing the modified Cryo-Maze procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Resultado del Tratamiento , Procedimiento de Laberinto , Atrios Cardíacos , Taquicardia/diagnóstico , Recurrencia , Ablación por Catéter/efectos adversos
5.
Circ J ; 86(11): 1710-1718, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-35569971

RESUMEN

BACKGROUND: This study aimed to elucidate the short-term surgical outcomes and hemodynamics of the Intuity valve compared to the standard bioprosthesis in Japanese patients.Methods and Results: Among the 307 consecutive patients who underwent aortic valve replacement (AVR) between February 2019 and March 2021, the Intuity valve was implanted in 95 patients (Intuity group) and a conventional stented bioprosthesis was implanted in 193 patients (conventional group). After propensity score matching, there was no significant difference in in-hospital mortality between the Intuity (n=2, 3%) and conventional groups (n=0, P=0.490). Operation, cardiopulmonary bypass, and aortic cross-clamping times were significantly shorter in the Intuity group. Although the effective orifice area index, trans-prosthetic mean pressure gradient, and peak velocity were similar between the 2 groups at 1 week postoperatively, the Intuity group showed a better mean pressure gradient and peak velocity at 1 year postoperatively. Complete atrioventricular block requiring permanent pacemaker implantation developed in 2 patients (3%) in the Intuity group and none in the conventional group (P=0.476). Mild or greater paravalvular leakage was present in 8 patients (13%) in the Intuity group and 2 patients (3%) in the conventional group (P=0.095). CONCLUSIONS: AVR using the Intuity valve in Japanese patients is satisfactory, with a better valve performance and a low incidence of complete atrioventricular block at 1 year postoperatively.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Japón , Diseño de Prótesis , Resultado del Tratamiento
6.
Circ J ; 86(3): 393-401, 2022 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-35125372

RESUMEN

BACKGROUND: Transaortic transcatheter aortic valve replacement (TAo-TAVR) is an alternative to peripheral or transapical TAVR. The procedural feasibility, safety, and midterm outcomes of TAo-TAVR were investigated in this study.Methods and Results:Eighty-four consecutive patients underwent TAo-TAVR from 2011 to 2021. Their median age was 83 years (interquartile range, 80-87 years). The Edwards SAPIEN and Medtronic CoreValve devices were used in 45 (53.6%) and 38 (45.2%) patients, respectively. The surgical approach was a right mini-thoracotomy in 43 patients (51.2%) and partial sternotomy in 4 patients (4.8%). The remaining 37 patients (44.0%) underwent full sternotomy because of concomitant off-pump coronary artery bypass grafting. VARC-3 device success was achieved in 77 patients (91.7%). Valve migration occurred in 3 patients (3.6%) using a first-generation CoreValve device, necessitating implantation of a second valve. No aortic annulus rupture, aortic dissection, or coronary orifice occlusion occurred. Conversion to surgery was required for 1 patient because of uncontrollable bleeding. Only 1 in-hospital death occurred. New pacemaker implantation was required in 6 patients (7.1%). Echocardiography at discharge showed no or trivial paravalvular leak (PVL) in 58 patients (69.0%), mild PVL in 23 (27.4%), and mild to moderate PVL in 2 (2.4%) patients. The 1- and 3-year incidence of cardiovascular death was 1.6% and 4.8%, respectively, with no structural valve deterioration. CONCLUSIONS: TAo-TAVR is feasible and safe with satisfactory midterm outcomes using both currently available devices.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Mortalidad Hospitalaria , Humanos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
7.
Circ J ; 86(12): 1961-1967, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-36273915

RESUMEN

BACKGROUND: The superiority of a fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) in terms of overall survival, stroke events and pump thrombosis has been demonstrated in previous international analyses, so we evaluated a Japanese cohort for the same.Methods and Results: This retrospective observational study was conducted at Osaka University Medical Hospital and the National Cerebral and Cardiovascular Center in Japan. A total of 75 consecutive patients who underwent HeartMate3 (HM3) implantation were included. The primary endpoint was on-device survival, and the secondary endpoint was the incidence of LVAD-related complications at 2 years. All parameters were compared with those of the previously performed HeartMate II (HMII) implantation in 197 cases. The on-device survival rates were 94.7% and 92.3% in the HM3 and HMII groups, respectively, at the 2-year follow-up (P=0.62). The rehospitalization-free rate after implantation was 61.8% in the HM3 group, which was significantly higher than that in the HMII group (relative risk, 0.35; 95% confidence interval [CI], 0.23-0.55; P<0.0001). Event-free survival rates from cerebral cerebrovascular events and pump thrombosis in the HM3 group were significantly higher than those in the HMII group, at 97.2% and 100%, respectively (relative risk, 0.14; 95% CI 0.03-0.58); P=0.0015 and relative risk, not calculated; P=0.049, respectively). CONCLUSIONS: Satisfactory short-term outcomes were observed after HM3 implantation in a Japanese cohort.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Trombosis , Humanos , Corazón Auxiliar/efectos adversos , Japón/epidemiología , Accidente Cerebrovascular/complicaciones , Trombosis/etiología , Estudios Retrospectivos , Resultado del Tratamiento
8.
J Artif Organs ; 25(3): 214-222, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34866164

RESUMEN

A bridging strategy from extracorporeal life support (ECLS) is effective in salvage and a bridge to recovery or to a durable left ventricular assist device (LVAD) for acute refractory heart failure. However, the correlation of this strategy with adverse events after durable LVAD implantation has not been fully investigated. This study enrolled 158 consecutive patients who had either the HeartMate II or HeartMate 3 and were implanted for bridge-to-transplantation. These devices were implanted as the primary mechanical support device in 115 patients, whereas the remaining 43 underwent LVAD implantation as the bridge from central ECLS. The primary study endpoint was all-cause mortality and cerebrovascular accidents (CVAs) after durable LVAD implantation, and the secondary endpoints were adverse events. Overall survival was not significantly different between the two groups. In contrast, the probability of CVAs was significantly greater in the bridge group than in the primary group (probability of CVAs, P = 0.002; log-rank test). In Cox multivariate logistic regression analysis, a bridge from central ECLS was an independent predictive factor of CVAs (hazard ratio 4.27, 95% confidence interval 1.43-12.8; P = 0.0095). Patients who are bridged from central ECLS are more frequently complicated by CVAs compared with those who undergo primary implantation of a durable LVAD, but survival is not significantly different between the two groups. A bridge from central ECLS is an independent predictive factor of CVAs post-implantation of an LVAD.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Humanos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
9.
Heart Lung Circ ; 31(12): 1666-1676, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36150952

RESUMEN

AIM: This study aimed to evaluate the early and intermediate-term outcomes of patients who underwent concomitant off-pump coronary artery bypass grafting (CABG) and transcatheter aortic valve replacement (TAVR). METHOD: Between January 2014 and June 2021, 49 patients underwent concomitant off-pump CABG and TAVR via median sternotomy (TAVRCAB group) and 143 underwent concomitant on-pump CABG and surgical aortic replacement. Of the 143 patients who underwent on-pump surgery, 80 (SAVRCAB group) were eligible for comparison. The composite event included all-cause death, heart failure rehospitalisation, repeat revascularisation, brain infarction, and repeat aortic valve replacement. RESULTS: The Society of Thoracic Surgeons' predicted risk for mortality and age were higher in the TAVRCAB group than in the SAVRCAB group (7.1% vs 3.1% [p<0.001]; 81 yrs vs 75 years [p<0.001], respectively), while the surgical time was shorter (289 min vs 352 min; p<0.001). There was no conversion to on-pump surgery in the TAVRCAB group. The postoperative maximum creatinine kinase-MB value was lower in the TAVRCAB group. There was no deep sternal wound infection or repeat revascularisation in either group. Hospital death and brain infarction developed in one patient (1.3%) each in the SAVRCAB group, but in no patients in the TAVRCAB group. The rates of freedom from the composite event were similar between the two groups during the follow-up period. CONCLUSIONS: Concomitant off-pump CABG and TAVR would be a less-invasive alternative procedure for treating intermediate or high surgical risk patients with aortic stenosis and coronary artery disease unsuitable for percutaneous coronary intervention.


Asunto(s)
Estenosis de la Válvula Aórtica , Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Puente de Arteria Coronaria Off-Pump/efectos adversos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía
10.
Kyobu Geka ; 75(1): 21-28, 2022 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-35249073

RESUMEN

BACKGROUND: Size-mismatched heart transplantation( HTx) is associated with a risk of stenosis of the caval anastomosis site or low cardiac output syndrome. We developed a modified bicaval anastomosis technique( mBCAT) that achieved an adjustable caval anastomosis to compensate for the size mismatch. This study clarified clinical outcomes of HTx with mBCAT technique according to the degree of the size mismatch. METHODS AND RESULTS: This study consisted of 130 adult patients who underwent HTx with the mBCAT during a 22-year period and were followed up for at least 1 year. The cohort was divided into three groups according to the donor-to-recipient body weight ratio:<0.8, undersized group (n=19);0.8 ~1.3, size-matched group( n=89);and >1.3, oversized group( n=22). The undersized, size-matched, and oversized groups showed no significant differences in the rate of mild or worse tricuspid regurgitation on echocardiography at 1 month [ 1( 5.3%), 8( 9.0%), and 1( 4.6%), respectively;p=0.683] or the survival rate at 10 years( 100%, 96%, and 95%, respectively;p=0.452). The right heart catheter study revealed no pressure gradient across the orifices of both cavae in any patient. Additionally, the cardiac index immediately post-HTx was low in the undersized group, but improved over time in all groups, achieving the comparable value at 6 and 12 months post-HTx. CONCLUSIONS: The mBCAT prevented caval anastomosis-related complications in size-mismatched HTx and achieved excellent hemodynamics regardless of donor size.


Asunto(s)
Trasplante de Corazón , Insuficiencia de la Válvula Tricúspide , Adulto , Anastomosis Quirúrgica/métodos , Tamaño Corporal , Ecocardiografía , Trasplante de Corazón/métodos , Hemodinámica , Humanos , Donantes de Tejidos
11.
Heart Vessels ; 36(5): 675-685, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33580804

RESUMEN

Atrial tachycardia (AT) and atrial fibrillation (AF) commonly occur after cardiac surgeries (CSs). This study investigated the mechanisms and long-term outcomes of AT and AF ablation after various Maze procedures, particularly whether atrial tachyarrhythmias after the Maze procedure occur due to gaps in the Maze lines. We analyzed 37 consecutive cases with atrial tachyarrhythmias after the Maze procedures and concomitant CSs between 2007 and 2019. Fifty-nine atrial tachyarrhythmias were induced in 37 consecutive cases, and 49 of those atrial tachyarrhythmias were mappable ATs. Forty ATs were related to the Maze procedures in the 49 mappable ATs (81.6%). All 37 consecutive cases had residual electrical conductions (gaps) in the Maze lines (88 gaps; 2.4 ± 1.2 gaps/patient). Forty of 88 gaps (45.5%) were associated with gap-related ATs. The common ATs in this study were 1. peri-mitral atrial flutter due to gaps at pulmonary vein isolation (PVI) line to mitral valve annulus (MVA) (20 cases), and 2. peri-tricuspid atrial flutter due to gaps at right atrial incision to the tricuspid valve annulus (TVA) (10 cases). Forty-seven of 49 ATs (95.9%) were successfully ablated at the first session, and there were no complications. The mean follow-up period after ablation was 3.6 ± 3.2 (median, 2.1; interquartile range, 0.89-6.84) years. The Kaplan-Meier analysis of freedom from recurrent atrial tachyarrhythmias after Maze procedure was 82.7% at 1-year follow-up and 75.5% at 4-year follow-up after a single procedure. Reentry was the main mechanism of ATs after Maze procedures and concomitant CSs, and ATs were largely related to the gaps on the Maze lines between the PVI line and the MVA or those on the lines between right atrial incision to the TVA. Long-term follow-up data suggest that catheter ablation of atrial tachyarrhythmias after various Maze procedures is effective and safe.


Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ablación por Catéter/efectos adversos , Atrios Cardíacos/fisiopatología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
12.
J Cardiothorac Vasc Anesth ; 35(10): 2937-2944, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33593650

RESUMEN

OBJECTIVE: Investigate differences in the prevalence and severity of chronic postsurgical pain (CPSP) after cardiac surgery via thoracotomy versus sternotomy are not well-understood. DESIGN: An observational cohort study. SETTING: A tertiary care hospital. PARTICIPANTS: Four hundred twenty-eight patients (sternotomy: 192 patients, thoracotomy: 236 patients) who underwent mitral valve repair. INTERVENTIONS: A questionnaire about the severity of surgical wound pain evaluated with a numerical rating scale (NRS) was sent. NRS responses for current pain, peak pain in the last four weeks, and average pain in the last four weeks were evaluated. MEASUREMENTS AND MAIN RESULTS: The main outcomes were the severity of CPSP evaluated using NRS and the prevalence of CPSP. CPSP was defined as pain >0 that developed after a surgical procedure. During the median follow-up of 29 months, 79 patients complained of CPSP. (sternotomy: 15 patients, thoracotomy: 64 patients). Multivariate ordinal logistic regression showed that NRS responses for current pain (adjusted odds ratio [aOR], 3.17; 95% confidence interval [CI] 1.64-6.12; p = 0.001), peak pain in the last four weeks (aOR, 2.00; 95% CI 1.11-3.61; p = 0.021), and average pain in the last four weeks (aOR, 2.21; 95% CI 1.31-3.72; p = 0.003) were significantly higher in patients who underwent thoracotomy. Multivariate logistic regression showed that thoracotomy was an independent predictor of CPSP (aOR, 3.63; 95% CI 1.67-7.88; p = 0.001). CONCLUSIONS: The prevalence and severity of CPSP were higher among patients who underwent mitral valve repair via thoracotomy than sternotomy.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Esternotomía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Estudios de Cohortes , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Válvula Mitral/cirugía , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/etiología , Prevalencia , Esternotomía/efectos adversos , Toracotomía/efectos adversos , Resultado del Tratamiento
13.
J Cardiothorac Vasc Anesth ; 35(8): 2392-2396, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33158709

RESUMEN

OBJECTIVE: The ability of perioperative fluid management to prevent postoperative recurrence of atrial tachyarrhythmia remains controversial. The aim of the present study was to assess if intraoperative net fluid balance was associated with atrial tachyarrhythmia recurrence after the Cryo-Maze procedure. DESIGN: An observational cohort study. SETTING: A tertiary care hospital from April 2007 to May 2019. PARTICIPANTS: Four hundred forty-four patients undergoing the Cryo-Maze procedure in conjunction with other cardiac surgeries. INTERVENTIONS: The Cryo-Maze procedure in conjunction with other cardiac surgeries. MEASUREMENTS AND MAIN RESULTS: The main outcome was early atrial tachyarrhythmia recurrence, consisting of atrial fibrillation, atrial flutter, or atrial tachycardia, within the first three months after surgery. Complete follow-up was achieved in 443 patients (99.8%), of them 127 (28.6%) developed early atrial tachyarrhythmia recurrence. The median intraoperative net fluid balance was 1,627 mL (interquartile range, -215 to 3,557 mL). Multivariate logistic regression showed that intraoperative net fluid balance (p = 0.001), preoperative AF duration (adjusted odds ratio, 1.40; 95% CI, 1.17-1.68; p < 0.001) and left atrial volume index (aOR, 1.61; 95% CI, 1.06-2.45; p = 0.025) were independent predictors of early atrial tachyarrhythmia recurrence. The adjusted log odds were lowest (-1.52) when net fluid balance was 1,557 mL. CONCLUSIONS: There is a significant U-shaped association between intraoperative net fluid balance and early atrial tachyarrhythmia recurrence among patients undergoing the Cryo-Maze procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Recurrencia , Taquicardia/diagnóstico , Taquicardia/epidemiología , Taquicardia/etiología , Resultado del Tratamiento , Equilibrio Hidroelectrolítico
14.
J Cardiothorac Vasc Anesth ; 35(9): 2626-2630, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33334649

RESUMEN

OBJECTIVES: Balloon postdilation (BPD) is one strategy for decreasing paravalvular leakage, but its effect on long-term mortality remains unclear. The authors sought to clarify whether BPD influences long-term mortality of patients with transcatheter aortic valve replacement (TAVR). DESIGN: Single-center retrospective study. SETTING: National heart center; single institution. PARTICIPANTS: Participants were patients who underwent TAVR in the authors' hospital from January 2014 to December 2016. A balloon-expandable Sapien XT or Sapien3, or self-expandable CoreValve or Evolute R, was implanted according to the decision of the surgeon considering degree of calcification of the aortic valve. INTERVENTIONS: No interventions. MEASUREMENTS AND MAIN RESULTS: Multivariate Cox regression analysis and inverse probability weighted estimation were performed using a propensity score to examine whether BPD influenced six-year mortality. Ultimately, 180 patients were analyzed. During the follow-up period, with a median of 1104 (interquartile range: 730-1463) days, 41 patients died and cumulative incidence of mortality at six years was 22.8%. Society of Thoracic Surgeons score (odds ratio [OR]: 2.257, 95% CI: 1.213-4.197, p = 0.010)], BPD (OR: 0.306, 95% CI: 0.098-0.953, p = 0.041), and paravalvular regurgitation of at least moderate-to-mild severity after deploying (OR: 5.407, 95% CI: 1.626-17.978, p = 0.006) were significant factors of mortality. CONCLUSIONS: BPD is associated with reduced six-year mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
J Card Surg ; 36(1): 342-344, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33124696

RESUMEN

Primary cardiac lymphoma (PCL) is rare, with a frequency of 1.0%-1.6% among cardiac malignant tumors. Chemotherapy is often selected as a first-line treatment for PCL. However, when the tumor causes heart failure or life-threatening hemodynamic collapse, antecedent urgent surgery is required. We herein report a successful case of complete tumor resection and reconstruction of the right atrium and right ventricle using a bovine pericardial patch combined with tricuspid valve replacement in a patient with a huge PCL filling the right heart that manifested as tricuspid valve stenosis and subsequent heart failure.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Neoplasias Cardíacas , Linfoma , Animales , Bovinos , Atrios Cardíacos/cirugía , Insuficiencia Cardíaca/etiología , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/cirugía , Humanos
16.
Circ J ; 84(12): 2212-2223, 2020 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-33148937

RESUMEN

BACKGROUND: Appropriate indications and protocols for induction therapy using basiliximab have not been fully established in heart transplant (HTx) recipients. This study elucidated the influence of induction therapy using basiliximab along with delayed tacrolimus (Tac) initiation on the outcomes of high-risk HTx recipients.Methods and Results:A total of 86 HTx recipients treated with Tac-based immunosuppression were retrospectively reviewed. Induction therapy was administered to 46 recipients (53.5%) with impaired renal function, pre-transplant sensitization, and recipient- and donor-related risk factors (Induction group). Tac administration was delayed in the Induction group. Induction group subjects showed a lower cumulative incidence of acute cellular rejection grade ≥1R after propensity score adjustment, but this was not significantly different (hazard ratio [HR]: 0.63, 95% confidence interval [CI]: 0.37-1.08, P=0.093). Renal dysfunction in the Induction group significantly improved 6 months post-transplantation (P=0.029). The cumulative incidence of bacterial or fungal infections was significantly higher in the Induction group (HR: 10.6, 95% CI: 1.28-88.2, P=0.029). CONCLUSIONS: These results suggest that basiliximab-based induction therapy with delayed Tac initiation may suppress mild acute cellular rejection and improve renal function in recipients with renal dysfunction, resulting in its non-inferior outcome, even in high-risk patients, when applied to the appropriate recipients. However, it should be carefully considered in recipients at a high risk of bacterial and fungal infections.


Asunto(s)
Basiliximab/uso terapéutico , Trasplante de Corazón , Quimioterapia de Inducción , Enfermedades Renales , Tacrolimus/uso terapéutico , Rechazo de Injerto/prevención & control , Humanos , Terapia de Inmunosupresión , Inmunosupresores/uso terapéutico , Enfermedades Renales/tratamiento farmacológico , Estudios Retrospectivos
17.
J Artif Organs ; 23(3): 214-224, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32076901

RESUMEN

Conversion from peripheral extracorporeal life support (ECLS) to the central one can improve and stabilize hemodynamics in patients with refractory congestive heart failure-related multiorgan failure, whereas indication and selection of the type of the central ECLS have not been fully established. Institutional outcome of the conversion therapy was herein reviewed to verify indication and selection of three types of central ECLS. This study enrolled an institutional consecutive surgical series of 24 patients with refractory congestive heart failure under peripheral ECLS, related to fulminant myocarditis (n = 15), dilated cardiomyopathy (n = 5), or acute myocardial infarction (n = 4). They were converted to central Y-extracorporeal membrane oxygenation (ECMO, n = 6), extracorporeal ventricular assist device (EC-VAD, n = 12), or pump catheter (n = 6), dependent upon the degree of multiorgan failure. Despite the different degree of multiorgan failure prior to the conversion, improvement in end-organ perfusion and reduction in right atrial and pulmonary artery pressure were promptly achieved regardless of the type of the central ECLS. There were five in-hospital mortalities (21%) during the central ECLS, whereas mechanical support was weaned-off in 11 cases (46%) and durable LVAD was subsequently implanted for bridge to transplantation in eight cases (33%). Conversion from the peripheral ECLS to the central ones, such as central Y-ECMO, EC-VAD or pump catheter, promptly established a sufficient support with heart and lung unloading in patients with refractory congestive heart failure.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Cardíaca/terapia , Adolescente , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Corazón Auxiliar , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Miocarditis/complicaciones , Resultado del Tratamiento , Adulto Joven
18.
Kyobu Geka ; 73(7): 490-495, 2020 Jul.
Artículo en Japonés | MEDLINE | ID: mdl-32641667

RESUMEN

Minimally invasive cardiac surgery (MICS) via mini-right thoracotomy approach has been developed and standardized in the last 30 years, aiming to facilitate postoperative recovery and to minimize surgery-related complications. Mitral regurgitation is the major target of this MICS approach. In our institute, MICS mitral valve repair by direct vision under thoracoscopy guidance has been performed in 139 cases between 2011 and March 2018. Subsequently, robot-assisted surgery program was launched to perform mitral valve repair for 130 patients in the last 2 years. In-hospital and mid-term outcome post-mitral valve repair was not significantly different among sternotomy, MICS direct vision and MICS robot-assist approaches, though there were several pitfalls through the launch of the MICS program. Standardization of the MICS approach of mitral valve repair and other cardiac surgeries was herein summarized and associated pitfalls were explained from surgeons' view.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Válvula Mitral/cirugía , Esternotomía , Toracotomía , Resultado del Tratamiento
19.
Circ J ; 84(1): 61-68, 2019 12 25.
Artículo en Inglés | MEDLINE | ID: mdl-31801926

RESUMEN

BACKGROUND: Size-mismatched heart transplantation (HTx) is associated with a risk of stenosis of the caval anastomosis site or low cardiac output syndrome. We developed a modified bicaval anastomosis technique (mBCAT) that achieved an adjustable caval anastomosis to compensate for size mismatch. This study was performed to validate the rationale of the mBCAT for size-mismatched HTx.Methods and Results:This institutional consecutive series involved 106 patients who underwent HTx with the mBCAT during an 18-year period. The cohort was divided into 3 groups according to the donor-to-recipient body weight ratio: <0.8, undersized group (n=17); 0.8-1.3, size-matched group (n=68); and >1.3, oversized group (n=21); outcomes were compared. The undersized, size-matched, and oversized groups showed no significant differences in the rate of mild or worse echocardiographic tricuspid regurgitation at 1 month [1 (5.8%), 7 (10.2%), and 1 (4.8%), respectively; P=0.87] or the survival rate at 10 years [100%, 93.9%, and 100%, respectively; P=0.25]. The right heart catheter study revealed no pressure gradient across the orifices of both cavae in any patient. Additionally, the cardiac index immediately post-HTx was significantly low in the undersized group (P=0.008), but was similar to the other groups at 6 months post-HTx (P=0.16). CONCLUSIONS: The mBCAT prevented caval anastomosis-related complications in size-mismatched HTx and achieved excellent hemodynamics regardless of donor size.


Asunto(s)
Trasplante de Corazón , Hemodinámica , Donantes de Tejidos , Adulto , Anastomosis Quirúrgica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
20.
Pediatr Cardiol ; 40(6): 1322, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31218372

RESUMEN

The authors have retracted this article [1] because, contrary to the statement in the article, this research did not obtain ethics approval from the National Cerebral and Cardiovascular Center Institutional Review Board prior to submission of the manuscript to Pediatric Cardiology. All authors agree to this retraction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA