Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
AAPS J ; 24(4): 78, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35778641

RESUMEN

Twenty percent of baseline patient samples exhibited a pre-existing response in a bridging anti-drug antibody (ADA) assay for a human IgG4 monoclonal antibody (mAb) therapeutic. In some cases, assay signals were more than 100-fold higher than background, potentially confounding detection of true treatment-emergent ADA responses. The pre-existing reactivity was mapped by competitive inhibition experiments using recombinant proteins or chimeric human mAbs with IgG4 heavy chain regions swapped for IgG1 sequences. These experiments demonstrated that the majority of the samples had reactivity to an epitope containing leucine 445 in the CH3 domain of human IgG4. The pre-existing reactivity in baseline patient samples was mitigated by replacing the ADA assay capture reagent with a version of the drug containing a wild type IgG1 proline substitution at residue 445 without impacting detection of drug-specific, treatment-emergent ADA. Finally, purification on Protein G or anti-human IgG (H + L) columns indicated the pre-existing response was likely due to immunoglobulins in patient samples.


Asunto(s)
Anticuerpos Monoclonales , Inmunoglobulina G , Epítopos , Humanos , Inmunoglobulina G/química
2.
AAPS J ; 22(5): 112, 2020 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-32808205

RESUMEN

Neutralizing anti-drug antibody (NAb) assays often have lower drug tolerance (DT) than trough drug concentrations, potentially under-estimating NAb incidence. To improve DT, drug-specific proteins were coupled to magnetic beads to deplete drug in the sample. To avoid interference from carryover, drug-specific proteins that did not interfere in the NAb assay, such as target or non-blocking anti-drug antibodies, were selected. With the drug depletion step, DT improved by > 10-fold in two competitive ligand binding NAb assays. Analysis of anti-drug antibody positive clinical samples with elevated drug levels demonstrated that NAb incidence was under-estimated without the drug depletion step. However, these NAb-positive samples had low titer and no impact on drug concentrations.


Asunto(s)
Anticuerpos Monoclonales/aislamiento & purificación , Anticuerpos Neutralizantes/análisis , Inmunogenética/métodos , Preparaciones Farmacéuticas/aislamiento & purificación , Humanos
3.
Bioanalysis ; 9(9): 707-717, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28488898

RESUMEN

AIM: A bridging immunogenicity assay for a human IgG4 mAb therapeutic was transferred to an automation system to increase throughput. However, background signal increased five- to six-fold during the 6- to 8-h run. RESULTS: Noncovalent Fc contacts formed between labeled IgG4 drugs in reagent solutions stored during the automation run. This generated substantial background signal, reducing assay sensitivity by approximately sixfold. Fc interactions also significantly impacted the confirmation assay. Fc contacts formed between labeled and unlabeled drug, significantly increasing signal inhibition (∼7-70%) in the 6-h run. CONCLUSION: Storing labeled antibody solutions separately and combining them immediately before adding to samples reduced interference from Fc interactions. Preincubation time for reagent solutions should be strictly controlled for anti-drug antibody assays with IgG4 drugs to avoid false-positive results.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Inmunoglobulina G/inmunología , Receptores Fc/inmunología , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Inmunoensayo/métodos
4.
Bioanalysis ; 7(20): 2701-12, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26505555

RESUMEN

BACKGROUND: An assay measuring an IgG4 biotherapeutic in human serum used a drug-specific monoclonal antibody (mAb) capture reagent and an antihuman IgG4 mAb as detection reagent. However, serum IgG4 binding to the capture mAb via Fc-interactions was detected by the anti-IgG4 mAb, causing high background. RESULTS: Two approaches were developed to minimize background; incorporating a mild acid sample preparation step or using the Fab of the capture antibody. Either strategy improved signal:noise dramatically, increasing assay sensitivity >20-fold. Biophysical analyses of antibody domains indicated that noncovalent Fc oligomers could inhibit the background. CONCLUSION: Matrix interference from human IgG4 binding to the capture mAb was reduced with a Fab fragment of the drug-specific capture antibody or by incorporating a mild acid sample treatment into the assay.


Asunto(s)
Fragmentos Fc de Inmunoglobulinas/metabolismo , Inmunoglobulina G/sangre , Animales , Anticuerpos Monoclonales/inmunología , Anticuerpos Neutralizantes/inmunología , Cromatografía en Gel , Electroforesis en Gel de Poliacrilamida , Ensayo de Inmunoadsorción Enzimática , Haplorrinos , Humanos , Fragmentos Fab de Inmunoglobulinas/inmunología , Fragmentos Fab de Inmunoglobulinas/metabolismo , Fragmentos Fc de Inmunoglobulinas/genética , Inmunoglobulina G/inmunología , Ratones , Electroforesis en Gel de Poliacrilamida Nativa , Unión Proteica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA