Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 259(6): 1435-1441, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33074373

RESUMEN

PURPOSE: To investigate the dependence of the ciliary body length (CBL) on the axial length (AL) and to draw conclusions on implications regarding safe pars plana access for intravitreal injections and vitreoretinal surgery. METHODS: A total of 200 individuals (mean age 42 years, SD ± 15.4) were enrolled in the study. Objective refraction and AL were obtained. Spherical equivalent (SE) was calculated. Anterior segment optical coherence tomography (ASOCT) was used to image and measure the CBL. RESULTS: The mean SE was - 1.64 diopters (SD ± 3.15, range - 14.5 to + 9 diopters) and the mean AL was 24.19 mm (SD ± 1.65, range 19.8-32.2 mm). There was a significant correlation between SE and AL (r2 = 0.62, p < 0.0001). Mean CBL correlated significantly with age (r2 = 0.11, p < 0.0001), AL (r2 = 0.23, p < 0.0001) and SE (r2 = 0.25, p < 0.0001). The mean CBL was 3351 µm (SD ± 459, range 2184-4451 µm). Three separate groups were defined by their AL with a normal AL group (AL 22.5 to 25 mm), a short AL group (AL < 22.5 mm) and a long AL group (AL > 25 mm). The mean CBL in the normal AL group was 3311 µm (SD ± 427), in the short AL group 2936 µm (SD ± 335) and in the long AL group 3715 µm (SD ± 365), and differed significantly (p < 0.0001) when compared. CONCLUSION: For interventions requiring pars plana access (as an intravitreal injection or vitreoretinal surgery), an incision distance of 3.5-4.0 mm posterior to the limbus is recommended. In our research, however, a difference of 0.77 mm in mean CBL between the group with short AL and the group with long AL is demonstrated, implying that the mean CBL in very short and very long eyes differs significantly. These findings suggest that the AL should be taken into account for pars plana access and that it would be advisable to prefer the shorter or longer recommended distance (3.5 and 4.0 mm, respectively) from the limbus, which correlates with the AL. If AL is > 25 mm, a distance of 4.0 mm from the limbus should be chosen; and if AL is < 22.5 mm, a distance of 3.5 mm seems adequate. TRIAL REGISTRATION NUMBER AND DATE: NCT00564291, 27 Nov 2007.


Asunto(s)
Cuerpo Ciliar , Tomografía de Coherencia Óptica , Adulto , Cuerpo Ciliar/diagnóstico por imagen , Cuerpo Ciliar/cirugía , Femenino , Humanos , Inyecciones Intravítreas , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA