Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(4): 766-771, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37560819

RESUMEN

Aortic regurgitation (AR) is associated with morbidity and premature mortality. Surgical aortic valve replacement is not an option for many patients due to an adverse surgical risk profile, whilst transcatheter aortic valve implantation with most available prostheses has demonstrated suboptimal implantation success and outcomes. The JenaValve Trilogy™ system provides an attractive solution for such patients as it utilizes clips that directly attach onto the native valve leaflets to anchor. Initially designed for transapical delivery, the current transfemoral delivery system is under investigation in the United States and approved for aortic stenosis and regurgitation in Europe. We present an expert review on the technical aspects of the Trilogy system, provide a guide for implantation, discuss the available evidence for the technology and provide illustrative case examples.

2.
Cardiology ; 148(6): 556-570, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37442111

RESUMEN

BACKGROUND: Elderly patients with aortic stenosis (AS) not only have a reduced life expectancy but also a reduced quality of life (QoL). The benefits of an AS intervention may be considered a balance between a good QoL and a reasonably extended life. However, the different questionnaires being used to determine the QoL were generally not developed for the specific situation of patients with AS and come with strengths and considerable weaknesses. The objective of this article was to provide an overview of the available QoL instruments in AS research, describe their strengths and weaknesses, and provide our assessment of the utility of the available scoring instruments for QoL measurements in AS. SUMMARY: We identified and reviewed the following instruments that are used in AS research: Short Form Health Survey (SF-36/SF-12), EuroQol-5D (EQ-5D), the Illness Intrusiveness Rating Scale (IIRS), the HeartQoL, the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Minnesota Living with Heart Failure Questionnaire (MLHF), the MacNew Questionnaire, and the Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ). KEY MESSAGES: There is no standardized assessment of QoL in patients with AS. Many different questionnaires are being used, but they are rarely specific for AS. There is a need for AS-specific research into the QoL of patients as life prolongation may compete for an improved QoL in this elderly patient group.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Humanos , Anciano , Calidad de Vida , Encuestas y Cuestionarios
3.
Pacing Clin Electrophysiol ; 45(1): 103-110, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34727374

RESUMEN

BACKGROUND: Permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve implantation (TAVI). The optimum timing of PPM implantation is still unclear as conduction abnormalities evolve and a balance needs to be struck between conservative delays in the hope of conduction recovery and overutilization of pacing. This study aimed to assess the safety and efficacy of early PPM implantation, without an observation period, among TAVI patients. METHODS: This is a retrospective, observational study of 1398 TAVI patients. Clinical and pacing data were collected at baseline, 30 days and at a median of 15 (4-21) months post-TAVI. Study endpoints included PPM-related complications, pacing utilization and hospital length of stay. RESULTS: One hundred five patients (8.2%) required a PPM, of which 13 were implanted pre and 92 post-TAVI. Seventy-six percent required pacing for either second- or third-degree heart block. Time to implantation for post-TAVI PPM was 1 (0-3) day. Six patients experienced a pacing-related complication- lead displacement (n = 3), hematoma (n = 2), and device infection (n = 1). Pacing utilization defined as pacing >10% of the time or a pacing requirement at the time of the pacing check was demonstrated in 83% of patients. Multivariate analysis revealed complete heart block (CHB) was the only independent predictor of pacing utilization. Hospital length of stay for the post-TAVI PPM group was longer than the group without PPM (4 [2-8] vs. 3 [2-4] days; p < .001). CONCLUSIONS: Early PPM implantation in TAVI patients is safe and majority of patients require pacing in the short and mid-term.


Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Estudios Retrospectivos
4.
JAMA ; 327(19): 1875-1887, 2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35579641

RESUMEN

Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear. Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk. Design, Setting, and Participants: In this randomized clinical trial conducted at 34 UK centers, 913 patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk due to age or comorbidity were enrolled between April 2014 and April 2018 and followed up through April 2019. Interventions: TAVI using any valve with a CE mark (indicating conformity of the valve with all legal and safety requirements for sale throughout the European Economic Area) and any access route (n = 458) or surgical aortic valve replacement (surgery; n = 455). Main Outcomes and Measures: The primary outcome was all-cause mortality at 1 year. The primary hypothesis was that TAVI was noninferior to surgery, with a noninferiority margin of 5% for the upper limit of the 1-sided 97.5% CI for the absolute between-group difference in mortality. There were 36 secondary outcomes (30 reported herein), including duration of hospital stay, major bleeding events, vascular complications, conduction disturbance requiring pacemaker implantation, and aortic regurgitation. Results: Among 913 patients randomized (median age, 81 years [IQR, 78 to 84 years]; 424 [46%] were female; median Society of Thoracic Surgeons mortality risk score, 2.6% [IQR, 2.0% to 3.4%]), 912 (99.9%) completed follow-up and were included in the noninferiority analysis. At 1 year, there were 21 deaths (4.6%) in the TAVI group and 30 deaths (6.6%) in the surgery group, with an adjusted absolute risk difference of -2.0% (1-sided 97.5% CI, -∞ to 1.2%; P < .001 for noninferiority). Of 30 prespecified secondary outcomes reported herein, 24 showed no significant difference at 1 year. TAVI was associated with significantly shorter postprocedural hospitalization (median of 3 days [IQR, 2 to 5 days] vs 8 days [IQR, 6 to 13 days] in the surgery group). At 1 year, there were significantly fewer major bleeding events after TAVI compared with surgery (7.2% vs 20.2%, respectively; adjusted hazard ratio [HR], 0.33 [95% CI, 0.24 to 0.45]) but significantly more vascular complications (10.3% vs 2.4%; adjusted HR, 4.42 [95% CI, 2.54 to 7.71]), conduction disturbances requiring pacemaker implantation (14.2% vs 7.3%; adjusted HR, 2.05 [95% CI, 1.43 to 2.94]), and mild (38.3% vs 11.7%) or moderate (2.3% vs 0.6%) aortic regurgitation (adjusted odds ratio for mild, moderate, or severe [no instance of severe reported] aortic regurgitation combined vs none, 4.89 [95% CI, 3.08 to 7.75]). Conclusions and Relevance: Among patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk, TAVI was noninferior to surgery with respect to all-cause mortality at 1 year. Trial Registration: isrctn.com Identifier: ISRCTN57819173.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
5.
Eur Heart J ; 41(29): 2759-2767, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32267922

RESUMEN

AIMS: Cardiac amyloidosis is common in elderly patients with aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI). We hypothesized that patients with dual aortic stenosis and cardiac amyloid pathology (AS-amyloid) would have different baseline characteristics, periprocedural and mortality outcomes. METHODS AND RESULTS: Patients aged ≥75 with severe AS referred for TAVI at two sites underwent blinded bone scintigraphy prior to intervention (Perugini Grade 0 negative, 1-3 increasingly positive). Baseline assessment included echocardiography, electrocardiogram (ECG), blood tests, 6-min walk test, and health questionnaire, with periprocedural complications and mortality follow-up. Two hundred patients were recruited (aged 85 ± 5 years, 50% male). AS-amyloid was found in 26 (13%): 8 Grade 1, 18 Grade 2. AS-amyloid patients were older (88 ± 5 vs. 85 ± 5 years, P = 0.001), with reduced quality of life (EQ-5D-5L 50 vs. 65, P = 0.04). Left ventricular wall thickness was higher (14 mm vs. 13 mm, P = 0.02), ECG voltages lower (Sokolow-Lyon 1.9 ± 0.7 vs. 2.5 ± 0.9 mV, P = 0.03) with lower voltage/mass ratio (0.017 vs. 0.025 mV/g/m2, P = 0.03). High-sensitivity troponin T and N-terminal pro-brain natriuretic peptide were higher (41 vs. 21 ng/L, P < 0.001; 3702 vs. 1254 ng/L, P = 0.001). Gender, comorbidities, 6-min walk distance, AS severity, prevalence of disproportionate hypertrophy, and post-TAVI complication rates (38% vs. 35%, P = 0.82) were the same. At a median follow-up of 19 (10-27) months, there was no mortality difference (P = 0.71). Transcatheter aortic valve implantation significantly improved outcome in the overall population (P < 0.001) and in those with AS-amyloid (P = 0.03). CONCLUSIONS: AS-amyloid is common and differs from lone AS. Transcatheter aortic valve implantation significantly improved outcome in AS-amyloid, while periprocedural complications and mortality were similar to lone AS, suggesting that TAVI should not be denied to patients with AS-amyloid.


Asunto(s)
Amiloidosis , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Prevalencia , Calidad de Vida , Factores de Riesgo , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 96(3): E348-E354, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31696656

RESUMEN

OBJECTIVES: To assess the safety and efficacy of first-line transcatheter aortic valve implantation (TAVI) in patients presenting with acute decompensated aortic stenosis (ADAS). BACKGROUND: ADAS is common and is often treated medically or using balloon aortic valvuloplasty in the first instance. This temporizing measure results in suboptimal outcomes. In the current era, TAVI provides an alternative option. METHODS: Consecutive patients who had either a TAVI for ADAS or electively were included in the study. The primary outcome was procedural and 30-day mortality and hospital length of stay (LOS). Secondary outcomes included 1-year mortality and procedural complications. RESULTS: Of note, 893 patients (mean age 83 ± 7, 50.5% male) underwent TAVI (19% ADAS, 81% elective). ADAS patients were more unwell with worse echocardiographic parameters than elective patients. ADAS patients of 55.9% were known to have significant aortic stenosis prior to their decompensation. Procedural mortality was not different between the ADAS and elective cohorts (1.2 vs. 0.7%; p = .62). The ADAS cohort had a higher 30-day mortality (5.3 vs. 1.1%; p = .002) and longer LOS (31.9 ± 20.7 days vs. 6.1 ± 6.5 days; p < .001). Multivariate analysis identified acute kidney injury and ADAS as significant predictors of 30-day mortality. CONCLUSIONS: TAVI for ADAS is safe and effective with procedural outcomes similar to elective patients. However, compared to elective patients, they have worse physiological baseline features, poorer prognosis at 30 days, and longer hospital admissions. Majority of patients who presented with ADAS were known to have AS prior to admission.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estudios de Factibilidad , Femenino , Hemodinámica , Humanos , Tiempo de Internación , Londres , Masculino , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
7.
J Card Surg ; 35(2): 320-327, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31803987

RESUMEN

BACKGROUND: Young patients with coronary artery disease are undergoing percutaneous coronary intervention (PCI) primarily, with a view to deferring coronary artery bypass grafting (CABG). We investigated the validity of this approach, by comparing outcomes in patients ≤50 years undergoing CABG or PCI. METHODS: One hundred consecutive patients undergoing PCI and 100 undergoing CABG in 2004 were retrospectively studied to allow for 5 and 12 years follow-up. The two groups were compared for the primary endpoints of major adverse cardiac or cerebrovascular event (MACCE). RESULTS: Diabetes, peripheral vascular disease, and left ventricular ejection fraction <50% were higher in the CABG group. At 5 years, rates of myocardial infarction (MI) (9% vs 1%, P = .02), repeat revascularization (31% vs 7%, P < .01), and MACCE (34 vs 12, P < .01) were greater in the PCI vs the CABG group. Similarly, at 12 years, rates of MI (27.4% vs 19.4%, P = .19), repeat revascularization (41.1% vs 20.4%, P < .01), and MACCE (51 vs 40, P = .07) were greater in the PCI group. There were no differences in major outcomes in patients with 1 or 2VD, at 5 or 12 years. Rates of MI, revascularization, and MACCE were higher in patients with 3VD undergoing PCI (n = 21; MI, 47.6%; revascularization, 66.7%; and MACCE, 19 events) vs CABG (n = 78; MI, 19.2%; revascularization, 20.5%; and MACCE, 31 events); P < .01, for all end points. CONCLUSIONS: MACCE was lower in young patients undergoing CABG vs PCI at both 5 and 12 years follow-up, primarily as a consequence of patients with 3VD undergoing PCI having more MI and repeat revascularization. CABG should remain the preferred method of revascularization in young patients with 3VD.


Asunto(s)
Puente de Arteria Coronaria , Intervención Coronaria Percutánea , Adulto , Factores de Edad , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/etiología , Trastornos Cerebrovasculares/epidemiología , Trastornos Cerebrovasculares/etiología , Diabetes Mellitus , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Recurrencia , Reoperación , Volumen Sistólico , Factores de Tiempo , Enfermedades Vasculares , Función Ventricular Izquierda
8.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30394657

RESUMEN

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Irlanda , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
10.
J Clin Med ; 13(10)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38792512

RESUMEN

Background/Objectives: Contrast-induced acute kidney injury (AKI) is associated with early mortality and adverse events. However, in the setting of transcatheter aortic valve implantation (TAVI), previous literature has failed to establish a correlation between the absolute volume of contrast media administered and mortality. We aimed to investigate the impact of contrast volume administered normalised to estimated glomerular filtration rate (CV/eGFR) on the development of AKI and on 30-day all-cause mortality in TAVI patients. Methods: We retrospectively analysed a cohort of 1150 patients who underwent TAVI at our unit between 2015 and 2018. Results: Follow-up was complete for 1064 patients. There were 23 deaths within the follow-up period and 76 cases of AKI, 9 of which required new renal replacement therapy (RRT). Receiver-operating characteristic (ROC) curve analysis showed fair discrimination for 30-day all-cause mortality at a CV/eGFR ratio of 3.6 (area under the ROC curve (AUC) 0.671). Of patients in whom CV data were available, 86.0% (n = 757) had a CV/eGFR < 3.6 and 14.0% (n = 123) had a CV/eGFR ≥ 3.6. In multivariate logistic regression analysis, CV/eGFR ≥ 3.6 was the strongest predictor of 30-day all-cause mortality (odds ratio 5.06, 95% confidence interval [1.61-15.7], p = 0.004). Other independent predictors were procedural urgency (3.28 [1.04-10.3], p = 0.038) and being under general anaesthesia (4.81 [1.10-17.3], p = 0.023). CV/eGFR ≥ 3.6 was also independently associated with significantly increased odds of AKI (2.28 [1.20-4.17], p = 0.009) alongside significant non-left main stem coronary artery disease (2.56 [1.45-4.66], p = 0.001), and diabetes (1.82 [1.03-3.19], p = 0.037). In supplementary ROC curve analysis, a similar CV/eGFR cut point of 3.6 was found to be an excellent predictor for new RRT (AUC 0.833). Conclusions: In conclusion, a CV/eGFR ≥ 3.6 post-TAVI was found to be a strong predictor of 30-day mortality and AKI. The maximum contrast volume that can be safely administered in each patient without significantly increasing the risk of mortality and AKI can be calculated using this ratio.

11.
JACC Case Rep ; 28: 102131, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38204547

RESUMEN

A 54-year-old woman who had recently undergone surgical mitral and tricuspid valve repair was diagnosed with severe aortic regurgitation. She was scheduled for percutaneous treatment and underwent successful transcatheter aortic valve implantation with a 27-mm Trilogy valve (JenaValve Technology). The case documents feasibility of percutaneous treatment in the presence of a mitral ring.

12.
Eur Heart J Qual Care Clin Outcomes ; 9(7): 724-730, 2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-36378116

RESUMEN

BACKGROUND: Acute decompensated aortic stenosis (ADAS) is common and associated with higher mortality, acute kidney injury (AKI) and longer hospital length of stay (LoS) compared with electively treated stable AS. The aim of this study was to assess the impact of a dedicated pathway that reduces time to transcatheter aortic valve implantation (TAVI) in ADAS, hypothesizing that LoS can be reduced without compromising patient safety. METHODS AND RESULTS: Using a prospective, open label, cluster design, patients from 5 referring centres were allocated to the ASessment and TReatment In Decompensated Aortic Stenosis (ASTRID-AS) pathway where the diagnosis, referral, investigations and treatment of ADAS were prioritised and expedited. 15 hospitals remained on the conventional pathway that followed the same process, albeit according to a waiting list. The primary efficacy endpoint was hospital LoS and the secondary safety endpoint, a composite of death or AKI at 30 days post-TAVI. 58 conventional patients and 25 ASTRID-AS patients were included in this study. Time to TAVI in the conventional vs. ASTRID-AS cohort was 22 (15-30) vs. 10 (6-12) days; P < 0.001, respectively. Length of hospital stay was 24 (18-33) vs. 13 (8-18) days; P < 0.001, respectively. 13.4 bed days were saved per patient using the ASTRID-AS pathway. Secondary safety endpoint occurred in 12 (20.7%) vs. 1 (4.0%) patients; P = 0.093, respectively. Procedural complications were similar between the two cohorts. CONCLUSION: A dedicated pathway for ADAS that shortens time to TAVI demonstrated reduced hospital LoS without compromising patient safety and a trend towards improving clinical outcomes.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Humanos , Proyectos Piloto , Estudios Prospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico
13.
Am J Cardiol ; 192: 206-211, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36842338

RESUMEN

Patients with classic low-flow low-gradient (cLFLG) aortic stenosis (AS) have a poor prognosis but still benefit from aortic valve replacement. There is a paucity of evidence to guide the choice between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). This study compared procedural and midterm outcomes in patients with cLFLG AS between TAVR and SAVR. Patients with cLFLG AS, defined as an aortic valve area ≤1 cm2, mean gradient <40 mm Hg, and left ventricular ejection fraction <50%, were selected from a single center between 2015 and 2020. Inverse probability weighting and regression were used to adjust for differences in baseline characteristics, the nonrandom assignment of treatment modalities, and procedural differences. The primary end point was all-cause mortality. A total of 322 patients (220 TAVR and 102 SAVR) were included. At a follow-up of 4.4 ± 1.5 years, the adjusted hazard ratio (HR) for mortality after inverse probability weighting with SAVR was 0.66, 95% confidence interval (CI) 0.31 to 1.35; p = 0.24. Worse renal function at baseline (per 10 ml/min/m2 increase HR 0.92, 95% CI 0.84 to 1.00, p = 0.04) and multiple valve interventions (HR 5.39, 95% CI 2.62 to 11.12, p <0.001) independently predicted mortality. There was no difference in stroke and permanent pacemaker implantation, but the rates of renal replacement therapy were higher among the SAVR cohort: 13.7% versus 0%; p <0.001. In conclusion, among patients with cLFLG AS, there was no difference in midterm mortality between TAVR and SAVR, supporting the use of either treatment. However, in patients with poor renal function or at risk of renal failure, TAVR may be the preferred option.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
14.
Cardiovasc Revasc Med ; 43: 13-17, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35534348

RESUMEN

BACKGROUND: Patients with aortic stenosis (AS) are susceptible to myocardial ischemia and often present acutely, making it challenging to differentiate between a type 1 NSTEMI and acute decompensated aortic stenosis. This study aims to evaluate the diagnostic accuracy of Troponin T (TnT) (>5 fold above the upper limit of normal), ischemic ECG and angina, to predict a type 1 non-ST elevation myocardial infarction (NSTEMI) and obstructive coronary artery disease (CAD) among patients with severe AS and acute presentations. METHODS: Patients with severe AS and acute symptoms: angina (Canadian Cardiovascular Society Class 3/4), dyspnea (New York Heart Association 4) and/or syncope were included. The endpoints were a type 1 NSTEMI defined by the presence of a coronary thrombus or > 90% stenosis and obstructive CAD defined as >70% stenosis, by computed tomography (CT) and/or invasive coronary angiography (ICA). RESULTS: Out of 273 patients, 6.2% had a type 1 NSTEMI. Positive TnT, ischemic ECG and angina demonstrated negative predictive values of 95%, 94% and 97% respectively and positive predictive values of 12%, 9% and 13% respectively. Specificity increased with all three metrics (95%), whilst sensitivity and positive predictive value reduced (18% and 19% respectively). 39.2% of patients had obstructive CAD. Positive TnT, ischemic ECG and angina demonstrated sensitivity of 64%, 34% and 41% respectively and specificity of 57%, 77% and 77% respectively. CONCLUSIONS: Angina, ischemic ECG and positive TnT are common among patients with AS presenting acutely and often not associated with a type 1 NSTEMI. These metrics, if positive, cannot reliably differentiate between a type 1 NSTEMI and acute decompensated AS. Coronary imaging using either CT or ICA is necessary to make a definitive diagnosis of a type 1 NSTEMI in patients with severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Infarto del Miocardio sin Elevación del ST , Angina de Pecho/diagnóstico , Angina de Pecho/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Canadá , Constricción Patológica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Troponina T
15.
Am J Cardiol ; 174: 96-100, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35527043

RESUMEN

Acute decompensated aortic stenosis (ADAS) is common and associated with poor outcomes. Myocardial remodeling and function, including a novel echo staging classification (0 to 4, representing increasing degrees of cardiac damage/dysfunction), impact outcomes in stable aortic stenosis. However, this has not been assessed in patients with ADAS. This study aims to evaluate the impact of the myocardium, echo staging classification, and clinical parameters on mortality in ADAS. ADAS was defined as an acute deterioration in symptoms (New York Heart Association 4, Canadian Cardiovascular Society 3/4, or syncope) that warranted admission to the hospital and urgent aortic valve replacement. Using a retrospective observational study design, 292 consecutive patients with ADAS who underwent transcatheter aortic valve implantation (TAVI) were identified and included in this study. Echocardiographic and clinical characteristics were evaluated using regression analysis. The outcome was all-cause mortality after TAVI. At 1 year after TAVI, advanced echo staging (>2) independently predicted mortality (hazards ratio: 1.85, 95% confidence interval: 1.01 to 3.39; p = 0.045). At a follow-up of 2.4 ± 1.4 years, myocardial, valvular, and clinical parameters did not predict mortality, except for frailty (hazards ratio: 2.31, 95% confidence interval: 1.38 to 3.85; p = 0.001). In patients with ADAS, short-term mortality after TAVI is influenced by more advanced cardiac damage/dysfunction based on the echo staging classification, whereas mid-term mortality is driven by frailty rather than echo staging classification.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Canadá , Fragilidad/complicaciones , Humanos , Pronóstico , Factores de Riesgo , Resultado del Tratamiento
16.
Open Heart ; 9(2)2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35790318

RESUMEN

OBJECTIVES: This study evaluates predictors of conduction abnormalities (CA) following transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valves (BAV). BACKGROUND: TAVI is associated with CA that commonly necessitate a permanent pacemaker. Predictors of CA are well established among patients with tricuspid aortic valves but not in those with BAV. METHODS: This is a single-centre, retrospective, observational study of patients with BAV treated with TAVI. Pre-TAVI ECG and CT scans and procedural characteristics were evaluated in 58 patients with BAV. CA were defined as a composite of high-degree atrioventricular block, new left bundle branch block with a QRS >150 ms or PR >240 ms and right bundle branch block with new PR prolongation or change in axis. Predictors of CA were identified using regression analysis and optimum cut-off values determined using area under the receiver operating characteristic curve analysis. RESULTS: CA occurred in 35% of patients. Bioprosthesis implantation depth, the difference between membranous septum (MS) length and implantation depth (δMSID) and device landing zone (DLZ) calcification adjacent to the MS were identified as univariate predictors of CA. The optimum cut-off for δMSID was 1.25 mm. Using this cut-off, low δMSID and DLZ calcification adjacent to MS predicted CA, adjusted OR 8.79, 95% CI 1.88 to 41.00; p=0.01. Eccentricity of the aortic valve annulus, type of BAV and valve calcium quantity and distribution did not predict CA. CONCLUSIONS: In BAV patients undergoing TAVI, short δMSID and DLZ calcification adjacent to MS are associated with an increased risk of CA.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Reemplazo de la Válvula Aórtica Transcatéter , Bloqueo de Rama , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
Heart ; 108(1): 67-72, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34497140

RESUMEN

OBJECTIVE: The coexistence of wild-type transthyretin cardiac amyloidosis (ATTR) is common in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). However, the impact of ATTR and AS on the resultant AS-ATTR is unclear and poses diagnostic and management challenges. We therefore used a multicohort approach to evaluate myocardial structure, function, stress and damage by assessing age-related, afterload-related and amyloid-related remodelling on the resultant AS-ATTR phenotype. METHODS: We compared four samples (n=583): 359 patients with AS, 107 with ATTR (97% Perugini grade 2), 36 with AS-ATTR (92% Perugini grade 2) and 81 age-matched and ethnicity-matched controls. 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scintigraphy was used to diagnose amyloidosis (Perugini grade 1 was excluded). The primary end-point was NT-pro Brain Natriuretic Peptide (BNP) and secondary end-points related to myocardial structure, function and damage. RESULTS: Compared with older age controls, the three disease cohorts had greater cardiac remodelling, worse function and elevated NT-proBNP/high-sensitivity Troponin-T (hsTnT). NT-proBNP was higher in AS-ATTR (2844 (1745, 4635) ng/dL) compared with AS (1294 (1077, 1554)ng/dL; p=0.002) and not significantly different to ATTR (3272 (2552, 4197) ng/dL; p=0.63). Diastology, hsTnT and prevalence of carpal tunnel syndrome were statistically similar between AS-ATTR and ATTR and higher than AS. The left ventricular mass indexed in AS-ATTR was lower than ATTR (139 (112, 167) vs 180 (167, 194) g; p=0.013) and non-significantly different to AS (120 (109, 130) g; p=0.179). CONCLUSIONS: The AS-ATTR phenotype likely reflects an early stage of amyloid infiltration, but the combined insult resembles ATTR. Even after treatment of AS, ATTR-specific therapy is therefore likely to be beneficial.


Asunto(s)
Neuropatías Amiloides Familiares , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Neuropatías Amiloides Familiares/diagnóstico , Neuropatías Amiloides Familiares/diagnóstico por imagen , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Humanos , Cintigrafía
18.
Eur Heart J Qual Care Clin Outcomes ; 7(4): 340-353, 2021 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-33751049

RESUMEN

Multiple guidelines exist for the management of aortic stenosis (AS). We systematically reviewed current guidelines and recommendations, developed by national or international medical organizations, on management of AS to aid clinical decision-making. Publications in MEDLINE and EMBASE between 1 June 2010 and 15 January 2021 were identified. Additionally, the International Guideline Library, National Guideline Clearinghouse, National Library for Health Guidelines Finder, Canadian Medical Association Clinical Practice Guidelines Infobase, and websites of relevant organizations were searched. Two reviewers independently screened titles and abstracts. Two reviewers assessed rigour of guideline development and extracted the recommendations. Of the seven guidelines and recommendations retrieved, five showed considerable rigour of development. Those rigourously developed, agreed on the definition of severe AS and diverse haemodynamic phenotypes, indications and contraindications for intervention in symptomatic severe AS, surveillance intervals in asymptomatic severe AS, and the importance of multidisciplinary teams (MDTs) and shared decision-making. Discrepancies exist in age and surgical risk cut-offs for recommending surgical aortic valve replacement (SAVR) vs. transcatheter aortic valve implantation (TAVI), the use of biomarkers and complementary multimodality imaging for decision-making in asymptomatic patients and surveillance intervals for non-severe AS. Contemporary guidelines for AS management agree on the importance of MDT involvement and shared decision-making for individualized treatment and unanimously indicate valve replacement in severe, symptomatic AS. Discrepancies exist in thresholds for age and procedural risk used in choosing between SAVR and TAVI, role of biomarkers and complementary imaging modalities to define AS severity and risk of progression in asymptomatic patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Canadá , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos
19.
JACC Cardiovasc Interv ; 14(19): 2083-2096, 2021 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-34620388

RESUMEN

Aortic stenosis (AS) and coronary artery disease (CAD) frequently coexist, with up to two thirds of patients with AS having significant CAD. Given the challenges when both disease states are present, these patients require a tailored approach diagnostically and therapeutically. In this review the authors address the impact of AS and aortic valve replacement (AVR) on coronary hemodynamic status and discuss the assessment of CAD and the role of revascularization in patients with concomitant AS and CAD. Remodeling in AS increases the susceptibility of myocardial ischemia, which can be compounded by concomitant CAD. AVR can improve coronary hemodynamic status and reduce ischemia. Assessment of the significance of coexisting CAD can be done using noninvasive and invasive metrics. Revascularization in patients undergoing AVR can benefit certain patients in whom CAD is either prognostically or symptomatically important. Identifying this cohort of patients is challenging and as yet incomplete. Patients with dual pathology present a diagnostic and therapeutic challenge; both AS and CAD affect coronary hemodynamic status, they provoke similar symptoms, and their respective treatments can have an impact on both diseases. Decisions regarding coronary revascularization should be based on understanding this complex relationship, using appropriate coronary assessment and consensus within a multidisciplinary team.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
20.
Clin Res Cardiol ; 110(11): 1781-1791, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33978816

RESUMEN

AIMS: Aortic stiffness, measured as aortic pulse wave velocity (PWV), is a powerful predictor of cardiovascular health but is difficult to accurately obtain non-invasively. This study sought to develop a novel CT aortic stiffness index (CTASI) which incorporates both anatomical (calcification) and physiological (distensibility) aspects of aortic health. METHODS: Invasive PWV and CT scans were obtained for 80 patients undergoing TAVI (cohort 1). CT data alone were obtained from an additional 238 patients (cohort 2). Aortic calcification was quantified using a modified Agatston's methodology. Distensibility-PWV was calculated from minimum and maximum ascending aorta areas. Linear regression of these values was used to construct CTASI from cohort 1. CTASI was then calculated for cohort 2 who were prospectively followed-up. RESULTS: CTASI correlated with invasive PWV (rho = 0.47, p < 0.01) with a higher correlation coefficient than distensibility-PWV (rho = 0.35, p < 0.01) and aortic calcification (rho = 0.36, p < 0.01). Compared to invasive PWV, CTASI had a good accuracy as a diagnostic test (AOC 0.72 [95% CI 0.61-0.84]), superior to aortic calcification and distensibility-PWV alone (χ2 = 0.82, p = 0.02). There were 61 deaths during a median follow-up of 771 days (95% CI 751.4-790.5). CTASI was able to predict 1-year mortality (OR 2.58, 95% CI 1.18-5.61, p = 0.02) and Kaplan-Meier survival (log-rank p = 0.03). CONCLUSION: CTASI is a stronger measure of aortic stiffness than aortic calcification or distensibility alone. Given the prolific use of CT scanning for assessing coronary and vascular disease, the additional calculation of CTASI during these scans could provide an important direct measurement of vascular health and guide pharmacological therapy.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Rigidez Vascular/fisiología , Anciano de 80 o más Años , Aorta Torácica/fisiopatología , Enfermedades Cardiovasculares/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA