1.
Artif Organs ; 39(6): 535-40, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25597956

RESUMEN

For hearing support devices, it is important to minimize the negative effect of ambient noises for speech recognition but also, at the same time, supply natural ambient sounds to the hearing-impaired person. However, conventional fixed bilateral asymmetric directional microphone (DM) algorithms cannot perform in such a way when the DM-mode device and a dominant noise (DN) source are placed on the same lateral hemisphere. In this study, a new binaural asymmetric DM algorithm that can overcome the defects of conventional algorithms is proposed. The proposed algorithm can estimate the position of a specific DN in the 90°-270° range and switch directional- and omnidirectional-mode devices automatically if the DM-mode device and the DN are placed in opposite lateral hemispheres. Computer simulation and KEMAR mannequin recording tests demonstrated that the performance of the conventional algorithm deteriorated when the DM-mode device and the DN were placed in the opposite hemisphere; in contrast, the performance of the proposed algorithm was consistently maintained regardless of directional variations in the DN. Based on these experimental results, the proposed algorithm may be able to improve speech quality and intelligibility for hearing-impaired persons who have similar degrees of hearing impairment in both ears.


Asunto(s)
Simulación por Computador , Diseño de Equipo , Audífonos , Pérdida Auditiva , Algoritmos , Humanos
2.
J Audiol Otol ; 24(2): 91-98, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31842534

RESUMEN

BACKGROUND AND OBJECTIVES: This study aimed to compare functional hearing with the use of a personal sound amplification product (PSAP) or a basic hearing aid (HA) among sensorineural hearing impaired listeners. Subjects and. METHODS: Nineteen participants with mild-to-moderate sensorineural hearing loss (SNHL) (26-55 dB HL; pure-tone average, 0.5-4 kHz) were prospectively included. No participants had prior experience with HAs or PSAPs. Audiograms, speech intelligibility in both quiet and noisy environments, speech quality, and preference were assessed in three different listening conditions: unaided, with the HA, and with the PSAP. RESULTS: The use of PSAP was associated with significant improvement in pure-tone thresholds at 1, 2, and 4 kHz compared to the unaided condition (all p <0.01). In the quiet environment, speech intelligibility was significantly improved after wearing a PSAP compared to the unaided condition (p <0.001), and this improvement was better than the result obtained with the HA. The PSAP also demonstrated similar improvement in the most comfortable levels compared to those obtained with the HA (p <0.05). However, there was no significant improvement of speech intelligibility in a noisy environment when wearing the PSAP (p =0.160). There was no significant difference in the reported speech quality produced by either device or in participant preference for the PSAP or HA. CONCLUSIONS: The current result suggests that PSAPs provide considerable benefits to speech intelligibility in a quiet environment and can be a good alternative to compensate for mild-to-moderate SNHL.

3.
Clin Exp Otorhinolaryngol ; 8(2): 102-10, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26045907

RESUMEN

OBJECTIVES: The clinical effects of the simultaneous application of nonlinear frequency compression and dichotic hearing on people with hearing impairments have not been evaluated previously. In this study, the clinical effects of the simultaneous application of these two techniques on the recognition of consonant-vowel-consonant (CVC) words with fricatives were evaluated using normal-hearing subjects and a hearing loss simulator operated in the severe hearing loss setting. METHODS: A total of 21 normal-hearing volunteers whose native language was English were recruited for this study, and two different hearing loss simulators, which were configured for severe hearing loss in the high-frequency range, were utilized. The subjects heard 82 English CVC words, and the word recognition score and response time were measured. RESULTS: The experimental results demonstrated that the simultaneous application of these two techniques showed almost even performance compared to the sole application of nonlinear frequency compression in a severe hearing loss setting. CONCLUSION: Though it is generally accepted that dichotic hearing can decrease the spectral masking thresholds of an hearing-impaired person, simultaneous application of the nonlinear frequency compression and dichotic hearing techniques did not significantly improve the recognition of words with fricatives compared to the sole application of nonlinear frequency compression in a severe hearing loss setting.