1.
Ann Neurol ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38738750

RESUMEN

OBJECTIVE: For stroke patients with unknown time of onset, mismatch between diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) can guide thrombolytic intervention. However, access to MRI for hyperacute stroke is limited. Here, we sought to evaluate whether a portable, low-field (LF)-MRI scanner can identify DWI-FLAIR mismatch in acute ischemic stroke. METHODS: Eligible patients with a diagnosis of acute ischemic stroke underwent LF-MRI acquisition on a 0.064-T scanner within 24 h of last known well. Qualitative and quantitative metrics were evaluated. Two trained assessors determined the visibility of stroke lesions on LF-FLAIR. An image coregistration pipeline was developed, and the LF-FLAIR signal intensity ratio (SIR) was derived. RESULTS: The study included 71 patients aged 71 ± 14 years and a National Institutes of Health Stroke Scale of 6 (interquartile range 3-14). The interobserver agreement for identifying visible FLAIR hyperintensities was high (κ = 0.85, 95% CI 0.70-0.99). Visual DWI-FLAIR mismatch had a 60% sensitivity and 82% specificity for stroke patients <4.5 h, with a negative predictive value of 93%. LF-FLAIR SIR had a mean value of 1.18 ± 0.18 <4.5 h, 1.24 ± 0.39 4.5-6 h, and 1.40 ± 0.23 >6 h of stroke onset. The optimal cut-point for LF-FLAIR SIR was 1.15, with 85% sensitivity and 70% specificity. A cut-point of 6.6 h was established for a FLAIR SIR <1.15, with an 89% sensitivity and 62% specificity. INTERPRETATION: A 0.064-T portable LF-MRI can identify DWI-FLAIR mismatch among patients with acute ischemic stroke. Future research is needed to prospectively validate thresholds and evaluate a role of LF-MRI in guiding thrombolysis among stroke patients with uncertain time of onset. ANN NEUROL 2024.

2.
Magn Reson Med ; 91(2): 541-557, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37753621

RESUMEN

PURPOSE: To investigate whether spatiotemporal magnetic field monitoring can correct pronounced eddy current-induced artifacts incurred by strong diffusion-sensitizing gradients up to 300 mT/m used in high b-value diffusion-weighted (DW) EPI. METHODS: A dynamic field camera equipped with 16 1 H NMR field probes was first used to characterize field perturbations caused by residual eddy currents from diffusion gradients waveforms in a 3D multi-shot EPI sequence on a 3T Connectom scanner for different gradient strengths (up to 300 mT/m), diffusion directions, and shots. The efficacy of dynamic field monitoring-based image reconstruction was demonstrated on high-gradient strength, submillimeter resolution whole-brain ex vivo diffusion MRI. A 3D multi-shot image reconstruction framework was developed that incorporated the nonlinear phase evolution measured with the dynamic field camera. RESULTS: Phase perturbations in the readout induced by residual eddy currents from strong diffusion gradients are highly nonlinear in space and time, vary among diffusion directions, and interfere significantly with the image encoding gradients, changing the k-space trajectory. During the readout, phase modulations between odd and even EPI echoes become non-static and diffusion encoding direction-dependent. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting reduction approaches such as navigator- and structured low-rank-based methods or MUSE followed by image-based distortion correction with the FSL tool "eddy." CONCLUSION: Strong eddy current artifacts characteristic of high-gradient strength DW-EPI can be well corrected with dynamic field monitoring-based image reconstruction.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen Eco-Planar/métodos
3.
Cereb Cortex ; 33(24): 11517-11525, 2023 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-37851854

RESUMEN

Speech and language processing involve complex interactions between cortical areas necessary for articulatory movements and auditory perception and a range of areas through which these are connected and interact. Despite their fundamental importance, the precise mechanisms underlying these processes are not fully elucidated. We measured BOLD signals from normal hearing participants using high-field 7 Tesla fMRI with 1-mm isotropic voxel resolution. The subjects performed 2 speech perception tasks (discrimination and classification) and a speech production task during the scan. By employing univariate and multivariate pattern analyses, we identified the neural signatures associated with speech production and perception. The left precentral, premotor, and inferior frontal cortex regions showed significant activations that correlated with phoneme category variability during perceptual discrimination tasks. In addition, the perceived sound categories could be decoded from signals in a region of interest defined based on activation related to production task. The results support the hypothesis that articulatory motor networks in the left hemisphere, typically associated with speech production, may also play a critical role in the perceptual categorization of syllables. The study provides valuable insights into the intricate neural mechanisms that underlie speech processing.


Asunto(s)
Percepción del Habla , Habla , Humanos , Habla/fisiología , Imagen por Resonancia Magnética/métodos , Mapeo Encefálico/métodos , Percepción Auditiva/fisiología , Percepción del Habla/fisiología
4.
Eur Radiol ; 33(4): 2905-2915, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36460923

RESUMEN

OBJECTIVES: High-resolution post-contrast T1-weighted imaging is a workhorse sequence in the evaluation of neurological disorders. The T1-MPRAGE sequence has been widely adopted for the visualization of enhancing pathology in the brain. However, this three-dimensional (3D) acquisition is lengthy and prone to motion artifact, which often compromises diagnostic quality. The goal of this study was to compare a highly accelerated wave-controlled aliasing in parallel imaging (CAIPI) post-contrast 3D T1-MPRAGE sequence (Wave-T1-MPRAGE) with the standard 3D T1-MPRAGE sequence for visualizing enhancing lesions in brain imaging at 3 T. METHODS: This study included 80 patients undergoing contrast-enhanced brain MRI. The participants were scanned with a standard post-contrast T1-MPRAGE sequence (acceleration factor [R] = 2 using GRAPPA parallel imaging technique, acquisition time [TA] = 5 min 18 s) and a prototype post-contrast Wave-T1-MPRAGE sequence (R = 4, TA = 2 min 32 s). Two neuroradiologists performed a head-to-head evaluation of both sequences and rated the visualization of enhancement, sharpness, noise, motion artifacts, and overall diagnostic quality. A 15% noninferiority margin was used to test whether post-contrast Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE. Inter-rater and intra-rater agreement were calculated. Quantitative assessment of CNR/SNR was performed. RESULTS: Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE for delineating enhancing lesions with unanimous agreement in all cases between raters. Wave-T1-MPRAGE was noninferior in the perception of noise (p < 0.001), motion artifact (p < 0.001), and overall diagnostic quality (p < 0.001). CONCLUSION: High-accelerated post-contrast Wave-T1-MPRAGE enabled a two-fold reduction in acquisition time compared to the standard sequence with comparable performance for visualization of enhancing pathology and equivalent perception of noise, motion artifacts and overall diagnostic quality without loss of clinically important information. KEY POINTS: • Post-contrast wave-controlled aliasing in parallel imaging (CAIPI) T1-MPRAGE accelerated the acquisition of three-dimensional (3D) high-resolution post-contrast images by more than two-fold. • Post-contrast Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE with unanimous agreement between reviewers (100% in 80 cases) for the visualization of intracranial enhancing lesions. • Wave-T1-MPRAGE was equivalent to the standard sequence in the perception of noise in 94% (75 of 80) of cases and was preferred in 16% (13 of 80) of cases for decreased motion artifact.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Encéfalo/diagnóstico por imagen , Artefactos , Movimiento (Física)
5.
Eur Radiol ; 32(10): 7128-7135, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35925387

RESUMEN

OBJECTIVES: Wave-CAIPI (Controlled Aliasing in Parallel Imaging) enables dramatic reduction in acquisition time of 3D MRI sequences such as 3D susceptibility-weighted imaging (SWI) but has not been clinically evaluated at 1.5 T. We sought to compare highly accelerated Wave-CAIPI SWI (Wave-SWI) with two alternative standard sequences, conventional three-dimensional SWI and two-dimensional T2*-weighted Gradient-Echo (T2*w-GRE), in patients undergoing routine brain MRI at 1.5 T. METHODS: In this study, 172 patients undergoing 1.5 T brain MRI were scanned with a more commonly used susceptibility sequence (standard SWI or T2*w-GRE) and a highly accelerated Wave-SWI sequence. Two radiologists blinded to the acquisition technique scored each sequence for visualization of pathology, motion and signal dropout artifacts, image noise, visualization of normal anatomy (vessels and basal ganglia mineralization), and overall diagnostic quality. Superiority testing was performed to compare Wave-SWI to T2*w-GRE, and non-inferiority testing with 15% margin was performed to compare Wave-SWI to standard SWI. RESULTS: Wave-SWI performed superior in terms of visualization of pathology, signal dropout artifacts, visualization of normal anatomy, and overall image quality when compared to T2*w-GRE (all p < 0.001). Wave-SWI was non-inferior to standard SWI for visualization of normal anatomy and pathology, signal dropout artifacts, and overall image quality (all p < 0.001). Wave-SWI was superior to standard SWI for motion artifact (p < 0.001), while both conventional susceptibility sequences were superior to Wave-SWI for image noise (p < 0.001). CONCLUSIONS: Wave-SWI can be performed in a 1.5 T clinical setting with robust performance and preservation of diagnostic quality. KEY POINTS: • Wave-SWI accelerated the acquisition of 3D high-resolution susceptibility images in 70% of the acquisition time of the conventional T2*GRE. • Wave-SWI performed superior to T2*w-GRE for visualization of pathology, signal dropout artifacts, and overall diagnostic image quality. • Wave-SWI was noninferior to standard SWI for visualization of normal anatomy and pathology, signal dropout artifacts, and overall diagnostic image quality.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen , Artefactos , Encéfalo/diagnóstico por imagen , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos
6.
Pediatr Radiol ; 52(6): 1115-1124, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35119490

RESUMEN

BACKGROUND: Susceptibility-weighted imaging (SWI) is highly sensitive for intracranial hemorrhagic and mineralized lesions but is associated with long scan times. Wave controlled aliasing in parallel imaging (Wave-CAIPI) enables greater acceleration factors and might facilitate broader application of SWI, especially in motion-prone populations. OBJECTIVE: To compare highly accelerated Wave-CAIPI SWI to standard SWI in the non-sedated pediatric outpatient setting, with respect to the following variables: estimated scan time, image noise, artifacts, visualization of normal anatomy and visualization of pathology. MATERIALS AND METHODS: Twenty-eight children (11 girls, 17 boys; mean age ± standard deviation [SD] = 128.3±62 months) underwent 3-tesla (T) brain MRI, including standard three-dimensional (3-D) SWI sequence followed by a highly accelerated Wave-CAIPI SWI sequence for each subject. We rated all studies using a predefined 5-point scale and used the Wilcoxon signed rank test to assess the difference for each variable between sequences. RESULTS: Wave-CAIPI SWI provided a 78% and 67% reduction in estimated scan time using the 32- and 20-channel coils, respectively, corresponding to estimated scan time reductions of 3.5 min and 3 min, respectively. All 28 children were imaged without anesthesia. Inter-reader agreement ranged from fair to substantial (k=0.67 for evaluation of pathology, 0.55 for anatomical contrast, 0.3 for central noise, and 0.71 for artifacts). Image noise was rated higher in the central brain with wave SWI (P<0.01), but not in the peripheral brain. There was no significant difference in the visualization of normal anatomical structures and visualization of pathology between the standard and wave SWI sequences (P=0.77 and P=0.79, respectively). CONCLUSION: Highly accelerated Wave-CAIPI SWI of the brain can provide similar image quality to standard SWI, with estimated scan time reduction of 3-3.5 min depending on the radiofrequency coil used, with fewer motion artifacts, at a cost of mild but perceptibly increased noise in the central brain.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Niño , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Masculino , Neuroimagen/métodos , Proyectos Piloto
7.
Neuroimage ; 243: 118530, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34464739

RESUMEN

The first phase of the Human Connectome Project pioneered advances in MRI technology for mapping the macroscopic structural connections of the living human brain through the engineering of a whole-body human MRI scanner equipped with maximum gradient strength of 300 mT/m, the highest ever achieved for human imaging. While this instrument has made important contributions to the understanding of macroscale connectional topology, it has also demonstrated the potential of dedicated high-gradient performance scanners to provide unparalleled in vivo assessment of neural tissue microstructure. Building on the initial groundwork laid by the original Connectome scanner, we have now embarked on an international, multi-site effort to build the next-generation human 3T Connectome scanner (Connectome 2.0) optimized for the study of neural tissue microstructure and connectional anatomy across multiple length scales. In order to maximize the resolution of this in vivo microscope for studies of the living human brain, we will push the diffusion resolution limit to unprecedented levels by (1) nearly doubling the current maximum gradient strength from 300 mT/m to 500 mT/m and tripling the maximum slew rate from 200 T/m/s to 600 T/m/s through the design of a one-of-a-kind head gradient coil optimized to minimize peripheral nerve stimulation; (2) developing high-sensitivity multi-channel radiofrequency receive coils for in vivo and ex vivo human brain imaging; (3) incorporating dynamic field monitoring to minimize image distortions and artifacts; (4) developing new pulse sequences to integrate the strongest diffusion encoding and highest spatial resolution ever achieved in the living human brain; and (5) calibrating the measurements obtained from this next-generation instrument through systematic validation of diffusion microstructural metrics in high-fidelity phantoms and ex vivo brain tissue at progressively finer scales with accompanying diffusion simulations in histology-based micro-geometries. We envision creating the ultimate diffusion MRI instrument capable of capturing the complex multi-scale organization of the living human brain - from the microscopic scale needed to probe cellular geometry, heterogeneity and plasticity, to the mesoscopic scale for quantifying the distinctions in cortical structure and connectivity that define cyto- and myeloarchitectonic boundaries, to improvements in estimates of macroscopic connectivity.


Asunto(s)
Conectoma/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Masculino , Neuroimagen/métodos , Fantasmas de Imagen
8.
Magn Reson Med ; 86(3): 1560-1572, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33961301

RESUMEN

PURPOSE: Patients with active implants such as deep brain stimulation (DBS) devices are often denied access to MRI due to safety concerns associated with the radiofrequency (RF) heating of their electrodes. The majority of studies on RF heating of conductive implants have been performed in horizontal close-bore MRI scanners. Vertical MRI scanners which have a 90° rotated transmit coil generate fundamentally different electric and magnetic field distributions, yet very little is known about RF heating of implants in this class of scanners. We performed numerical simulations as well as phantom experiments to compare RF heating of DBS implants in a 1.2T vertical scanner (OASIS, Hitachi) compared to a 1.5T horizontal scanner (Aera, Siemens). METHODS: Simulations were performed on 90 lead models created from post-operative CT images of patients with DBS implants. Experiments were performed with wires and commercial DBS devices implanted in an anthropomorphic phantom. RESULTS: We found significant reduction of 0.1 g-averaged specific absorption rate (30-fold, P < 1 × 10-5 ) and RF heating (9-fold, P < .026) in the 1.2T vertical scanner compared to the 1.5T conventional scanner. CONCLUSION: Vertical MRI scanners appear to generate lower RF heating around DBS leads, providing potentially heightened safety or the flexibility to use sequences with higher power levels than on conventional systems.


Asunto(s)
Estimulación Encefálica Profunda , Electrodos Implantados , Calor , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Ondas de Radio
9.
Ann Neurol ; 88(4): 851-854, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32613682

RESUMEN

Many patients with severe coronavirus disease 2019 (COVID-19) remain unresponsive after surviving critical illness. Although several structural brain abnormalities have been described, their impact on brain function and implications for prognosis are unknown. Functional neuroimaging, which has prognostic significance, has yet to be explored in this population. Here we describe a patient with severe COVID-19 who, despite prolonged unresponsiveness and structural brain abnormalities, demonstrated intact functional network connectivity, and weeks later recovered the ability to follow commands. When prognosticating for survivors of severe COVID-19, clinicians should consider that brain networks may remain functionally intact despite structural injury and prolonged unresponsiveness. ANN NEUROL 2020;88:851-854.


Asunto(s)
Encéfalo/diagnóstico por imagen , Coma/diagnóstico por imagen , Infecciones por Coronavirus/fisiopatología , Estado Vegetativo Persistente/diagnóstico por imagen , Neumonía Viral/fisiopatología , Recuperación de la Función , Betacoronavirus , Encéfalo/fisiopatología , COVID-19 , Coma/fisiopatología , Infecciones por Coronavirus/terapia , Electroencefalografía , Neuroimagen Funcional , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Vías Nerviosas , Pandemias , Estado Vegetativo Persistente/fisiopatología , Neumonía Viral/terapia , Pronóstico , Insuficiencia Renal/fisiopatología , Respiración Artificial , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , SARS-CoV-2 , Choque/fisiopatología
10.
Pediatr Radiol ; 51(1): 77-85, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32845348

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) is a useful MRI technique to characterize abdominal lesions in children, but long acquisition times can lead to image degradation. Simultaneous multi-slice accelerated DWI is a promising technique to shorten DWI scan times. OBJECTIVE: To test the feasibility of simultaneous multi-slice DWI of the kidneys in pediatric patients with tuberous sclerosis complex (TSC) and to evaluate the accelerated protocol regarding image quality and quantitative apparent diffusion coefficient (ADC) values compared to standard echoplanar DWI sequence. MATERIALS AND METHODS: We included 33 children and adolescents (12 female, 21 male; mean age 10±5 years) with TSC and renal cyst or angiomyolipoma on 3-tesla (T) MRI from 2017 to 2019. All studies included both free-breathing standard echoplanar DWI and simultaneous multi-slice DWI sequences. Subjective and quantitative image quality was evaluated using a predefined 5-point scale. ADC values were obtained for all renal cysts and angiomyolipomas ≥5 mm. All statistical analysis was performed using Stata/SE v15.1. RESULTS: Simultaneous multi-slice DWI ADC values were slightly lower compared to standard echoplanar DWI for both renal cysts and angiomyolipomas (mean difference 0.05×10-3 mm2/s, 95% confidence interval [CI] 0.40-0.50 and 0.024×10-3 mm2/s, 95% CI 0.17-0.21, respectively, with P>0.1). Our results showed that renal lesions with ADC values >1.69×10-3 mm2/s were all cysts, whereas lesions with values <1.16×10-3 mm2/s were all angiomyolipomas. However, ADC values could not discriminate between lipid-rich and lipid-poor angiomyolipomas (P>0.1, for both sequences). CONCLUSION: A 55% reduction in scan time was achieved using simultaneous multi-slice DWI for abdominal imaging in children with TSC, with near identical image quality as standard DWI. These results suggest that multi-slice techniques should be considered more broadly as an MRI acceleration technique in children.


Asunto(s)
Esclerosis Tuberosa , Adolescente , Niño , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Femenino , Humanos , Recién Nacido , Riñón , Masculino , Reproducibilidad de los Resultados , Esclerosis Tuberosa/complicaciones , Esclerosis Tuberosa/diagnóstico por imagen
11.
Pediatr Radiol ; 51(11): 2009-2017, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34268599

RESUMEN

BACKGROUND: Fast magnetic resonance imaging (MRI) sequences are advantageous in pediatric imaging as they can lessen child discomfort, decrease motion artifact and improve scanner availability. OBJECTIVE: To evaluate the feasibility of an ultrafast wave-CAIPI (controlled aliasing in parallel imaging) MP-RAGE (magnetization-prepared rapid gradient echo) sequence for brain imaging of awake pediatric patients. MATERIALS AND METHODS: Each MRI included a standard MP-RAGE sequence and an ultrafast wave-MP-RAGE sequence. Two neuroradiologists evaluated both sequences in terms of artifacts, noise, anatomical contrast and pathological contrast. A predefined 5-point scale was used by two independent pediatric neuroradiologists. A Wilcoxon signed-rank test was used to evaluate the difference between sequences for each variable. RESULTS: Twenty-four patients (14 males; mean age: 11.5±4.5 years, range: 1 month to 17.8 years) were included. Wave-CAIPI MP-RAGE provided a 77% reduction in scan time using a 32-channel coil and a 70% reduction using a 20-channel coil. Visualization of the pathology, artifacts and pathological enhancement (including parenchymal, leptomeningeal and dural enhancement) was not significantly different between standard MP-RAGE and wave-CAIPI MP-RAGE (all P>0.05). For central (P<0.001) and peripheral (P<0.001) noise, and the evaluation of the anatomical structures (P<0.001), the observers favored standard MP-RAGE over wave-CAIPI MP-RAGE. CONCLUSION: Ultrafast brain imaging with wave-CAIPI MP-RAGE is feasible in awake pediatric patients, providing a substantial reduction in scan time at a cost of subjectively increased image noise.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Adolescente , Artefactos , Encéfalo/diagnóstico por imagen , Niño , Humanos , Masculino
12.
Skeletal Radiol ; 50(5): 1007-1015, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32918566

RESUMEN

OBJECTIVE: To evaluate the effect of circular polarization (CP) and elliptical polarization (EP) of the B1 field on metal implant-induced artifacts of titanium (Ti) and cobalt-chromium (CoCr) hip arthroplasty implants at 1.5-T and 3.0-T field strengths. MATERIAL AND METHODS: In vitro Ti and CoCr total hip arthroplasty implants were evaluated using high transmit and receive bandwidth turbo spin echo (HBW-TSE) and slice encoding for metal artifact correction (SEMAC) metal artifact reduction techniques. Each technique was implemented at 1.5-T, which only allows for CP of B1 field as the system default, as well as 3.0-T, which permitted CP and EP. Manual segmentation quantified the size of the metal artifacts at the level of the acetabular cup, femoral neck, and femoral shaft. RESULTS: In the acetabular cup and femoral neck, 1.5-T CP achieved smaller artifact sizes than 3.0-T CP (28-29% on HBW-TSE, p = 0.002-0.005; 17-34% on SEMAC, p = 0.019-0.102) and 3.0-T EP (25-28% on HBW-TSE, p = 0.010-0.011; 14-36% on SEMAC, p = 0.058-0.135) techniques. In the femoral stem region, 3.0-T EP achieved more efficient artifact suppression than 3.0-T CP (HBW-TSE 44-45%, p < 0.001-0.022; SEMAC 76-104%, p < 0.001-0.022) and 1.5-T CP (HBW-TSE 76-96%, p < 0.001-0.003; SEMAC 138-173%, p = 0.003-0.005) techniques. CONCLUSION: Despite slightly superior metal reduction ability of the 1.5-T in the region of the acetabular cup and prosthesis neck, 3.0-T MRI of hip arthroplasty implants using elliptically polarized RF pulses may overall be more effective in reducing metal artifacts than the current standard 1.5-T MRI techniques, which by default implements circularly polarized RF pulses.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artefactos , Humanos , Imagen por Resonancia Magnética , Metales , Prótesis e Implantes
13.
Radiology ; 295(2): 307-313, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32125255

RESUMEN

Background The risks associated with MRI in individuals who have implanted cardiac devices are thought to arise from the interaction between the implanted device and static, gradient, and radiofrequency magnetic fields. Purpose To determine the relationship between the peak whole-body averaged specific absorption rate (SAR) and change in magnetic field per unit time (dB/dt), maximum specific energy dose, imaging region, and implanted cardiac device characteristics and their function in patients undergoing MRI. Materials and Methods This prospective observational cohort study was conducted from October 16, 2003, to January 22, 2015 (https://ClinicalTrials.gov, NCT01130896). Any individual with an implanted cardiac device who was referred for MRI was included. Clinical MRI protocols without SAR restriction were used. Exclusion criteria were newly implanted leads, abandoned or epicardial leads, and dependence on a pacemaker with an implantable cardioverter defibrillator without asynchronous pacing capability. For each MRI pulse sequence, the calculated whole-body values for SAR, dB/dt, and scan duration were collected. Atrial and ventricular sensing, lead impedance, and capture threshold were evaluated before and immediately after (within 10 minutes) completion of each MRI examination. Generalized estimating equations with Gaussian family, identity link, and an exchangeable working correlation matrix were used for statistical analysis. Results A total of 2028 MRI examinations were performed in 1464 study participants with 2755 device leads (mean age, 67 years ± 15 [standard deviation]; 930 men [64%]). There was no evidence of an association between radiofrequency energy deposition, dB/dt, or scan duration and changes in device parameters. Thoracic MRI was associated with decreased battery voltage immediately after MRI (ß = -0.008 V, P < .001). Additionally, right ventricular (RV) lead length was associated with decreased RV sensing (ß = -0.012 mV, P = .05) and reduced RV capture threshold (ß = -0.002 V, P < .01) immediately after MRI. Conclusion There was no evidence of an association between MRI parameters that characterize patient exposure to radiofrequency energy and changes in device and lead parameters immediately after MRI. Nevertheless, device interrogation before and after MRI remains mandatory due to the potential for device reset and changes in lead or generator parameters. © RSNA, 2020 See also the editorial by Shellock in this issue.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética/métodos , Marcapaso Artificial , Seguridad del Paciente , Anciano , Protocolos Clínicos , Seguridad de Equipos , Femenino , Humanos , Masculino , Estudios Prospectivos , Ondas de Radio
14.
Magn Reson Med ; 83(6): 2284-2292, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31677308

RESUMEN

PURPOSE: Patients with deep brain stimulation (DBS) implants benefit highly from MRI, however, access to MRI is restricted for these patients because of safety hazards associated with RF heating of the implant. To date, all MRI studies on RF heating of medical implants have been performed in horizontal closed-bore systems. Vertical MRI scanners have a fundamentally different distribution of electric and magnetic fields and are now available at 1.2T, capable of high-resolution structural and functional MRI. This work presents the first simulation study of RF heating of DBS implants in high-field vertical scanners. METHODS: We performed finite element electromagnetic simulations to calculate specific absorption rate (SAR) at tips of DBS leads during MRI in a commercially available 1.2T vertical coil compared to a 1.5T horizontal scanner. Both isolated leads and fully implanted systems were included. RESULTS: We found 10- to 30-fold reduction in SAR implication at tips of isolated DBS leads, and up to 19-fold SAR reduction at tips of leads in fully implanted systems in vertical coils compared to horizontal birdcage coils. CONCLUSIONS: If confirmed in larger patient cohorts and verified experimentally, this result can open the door to plethora of structural and functional MRI applications to guide, interpret, and advance DBS therapy.


Asunto(s)
Estimulación Encefálica Profunda , Calefacción , Simulación por Computador , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Prótesis e Implantes , Ondas de Radio
15.
Radiographics ; 40(2): 485-502, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32031912

RESUMEN

Long acquisition times can limit the use of MRI in pediatric patients, and the use of sedation or general anesthesia is frequently necessary to facilitate diagnostic examinations. The use of sedation or anesthesia has disadvantages including increased cost and imaging time and potential risks to the patient. Reductions in imaging time may decrease or eliminate the need for sedation or general anesthesia. Over the past decade, a number of imaging techniques that can decrease imaging time have become commercially available. These products have been used increasingly in clinical practice and include parallel imaging, simultaneous multisection imaging, radial k-space acquisition, compressed sensing MRI reconstruction, and automated protocol selection software. The underlying concepts, supporting data, current clinical applications, and available products for each of these strategies are reviewed in this article. In addition, emerging techniques that are still under investigation may provide further reductions in imaging time, including artificial intelligence-based reconstruction, gradient-controlled aliasing sampling and reconstruction, three-dimensional MR spectroscopy, and prospective motion correction. The preliminary results for these techniques are also discussed. ©RSNA, 2020 See discussion on this article by Greer and Vasanawala.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Anestesia General , Inteligencia Artificial , Niño , Sedación Consciente , Humanos , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Espectroscopía de Resonancia Magnética , Factores de Tiempo
16.
Pediatr Radiol ; 50(13): 1830-1838, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33252752

RESUMEN

Fetal MRI allows for earlier and better detection of complex congenital anomalies. However, its diagnostic utility is often limited by technical barriers that introduce artifacts and reduce image quality. The main determinants of fetal MR image quality are speed of acquisition, spatial resolution and signal-to-noise ratio (SNR). Imaging optimization is a challenge because a change to improve one scan parameter often leads to worsening of another. Moreover, the recent introduction of fetal MRI on 3-tesla (T) scanners to achieve better SNR can amplify some technical issues. Motion, banding artifacts and aliasing artifacts impact the quality of fetal acquisitions at any field strength. High specific absorption rate (SAR) and artifacts from inhomogeneities in the radiofrequency field are important limitations of high-field-strength imaging. We discuss technical barriers that impact image quality and are important limitations to prenatal MRI diagnosis, and propose solutions to improve image quality and reduce artifacts.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Femenino , Feto/diagnóstico por imagen , Humanos , Aumento de la Imagen , Movimiento (Física) , Embarazo , Relación Señal-Ruido
17.
Neurocrit Care ; 33(2): 364-375, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32794142

RESUMEN

There are currently no therapies proven to promote early recovery of consciousness in patients with severe brain injuries in the intensive care unit (ICU). For patients whose families face time-sensitive, life-or-death decisions, treatments that promote recovery of consciousness are needed to reduce the likelihood of premature withdrawal of life-sustaining therapy, facilitate autonomous self-expression, and increase access to rehabilitative care. Here, we present the Connectome-based Clinical Trial Platform (CCTP), a new paradigm for developing and testing targeted therapies that promote early recovery of consciousness in the ICU. We report the protocol for STIMPACT (Stimulant Therapy Targeted to Individualized Connectivity Maps to Promote ReACTivation of Consciousness), a CCTP-based trial in which intravenous methylphenidate will be used for targeted stimulation of dopaminergic circuits within the subcortical ascending arousal network (ClinicalTrials.gov NCT03814356). The scientific premise of the CCTP and the STIMPACT trial is that personalized brain network mapping in the ICU can identify patients whose connectomes are amenable to neuromodulation. Phase 1 of the STIMPACT trial is an open-label, safety and dose-finding study in 22 patients with disorders of consciousness caused by acute severe traumatic brain injury. Patients in Phase 1 will receive escalating daily doses (0.5-2.0 mg/kg) of intravenous methylphenidate over a 4-day period and will undergo resting-state functional magnetic resonance imaging and electroencephalography to evaluate the drug's pharmacodynamic properties. The primary outcome measure for Phase 1 relates to safety: the number of drug-related adverse events at each dose. Secondary outcome measures pertain to pharmacokinetics and pharmacodynamics: (1) time to maximal serum concentration; (2) serum half-life; (3) effect of the highest tolerated dose on resting-state functional MRI biomarkers of connectivity; and (4) effect of each dose on EEG biomarkers of cerebral cortical function. Predetermined safety and pharmacodynamic criteria must be fulfilled in Phase 1 to proceed to Phase 2A. Pharmacokinetic data from Phase 1 will also inform the study design of Phase 2A, where we will test the hypothesis that personalized connectome maps predict therapeutic responses to intravenous methylphenidate. Likewise, findings from Phase 2A will inform the design of Phase 2B, where we plan to enroll patients based on their personalized connectome maps. By selecting patients for clinical trials based on a principled, mechanistic assessment of their neuroanatomic potential for a therapeutic response, the CCTP paradigm and the STIMPACT trial have the potential to transform the therapeutic landscape in the ICU and improve outcomes for patients with severe brain injuries.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Lesiones Encefálicas , Conectoma , Estado de Conciencia , Humanos , Unidades de Cuidados Intensivos , Resultado del Tratamiento
18.
J Digit Imaging ; 33(3): 747-762, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31950302

RESUMEN

The growing interest in machine learning (ML) in healthcare is driven by the promise of improved patient care. However, how many ML algorithms are currently being used in clinical practice? While the technology is present, as demonstrated in a variety of commercial products, clinical integration is hampered by a lack of infrastructure, processes, and tools. In particular, automating the selection of relevant series for a particular algorithm remains challenging. In this work, we propose a methodology to automate the identification of brain MRI sequences so that we can automatically route the relevant inputs for further image-related algorithms. The method relies on metadata required by the Digital Imaging and Communications in Medicine (DICOM) standard, resulting in generalizability and high efficiency (less than 0.4 ms/series). To support our claims, we test our approach on two large brain MRI datasets (40,000 studies in total) from two different institutions on two different continents. We demonstrate high levels of accuracy (ranging from 97.4 to 99.96%) and generalizability across the institutions. Given the complexity and variability of brain MRI protocols, we are confident that similar techniques could be applied to other forms of radiological imaging.


Asunto(s)
Metadatos , Radiología , Encéfalo/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Imagen por Resonancia Magnética
19.
Neuroimage ; 184: 566-576, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30243973

RESUMEN

Access to MRI is limited for patients with deep brain stimulation (DBS) implants due to safety hazards, including radiofrequency (RF) heating of tissue surrounding the leads. Computational models provide an exquisite tool to explore the multi-variate problem of RF heating and help better understand the interaction of electromagnetic fields and biological tissues. This paper presents a computational approach to assess RF-induced heating, in terms of specific absorption rate (SAR) in the tissue, around the tip of bilateral DBS leads during MRI at 64MHz/1.5 T and 127 MHz/3T. Patient-specific realistic lead models were constructed from post-operative CT images of nine patients operated for sub-thalamic nucleus DBS. Finite element method was applied to calculate the SAR at the tip of left and right DBS contact electrodes. Both transmit head coils and transmit body coils were analyzed. We found a substantial difference between the SAR and temperature rise at the tip of right and left DBS leads, with the lead contralateral to the implanted pulse generator (IPG) exhibiting up to 7 times higher SAR in simulations, and up to 10 times higher temperature rise during measurements. The orientation of incident electric field with respect to lead trajectories was explored and a metric to predict local SAR amplification was introduced. Modification of the lead trajectory was shown to substantially reduce the heating in phantom experiments using both conductive wires and commercially available DBS leads. Finally, the surgical feasibility of implementing the modified trajectories was demonstrated in a patient operated for bilateral DBS.


Asunto(s)
Estimulación Encefálica Profunda , Electrodos Implantados , Calor , Imagen por Resonancia Magnética/efectos adversos , Modelos Teóricos , Simulación por Computador , Estimulación Encefálica Profunda/instrumentación , Campos Electromagnéticos , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Ondas de Radio
20.
Magn Reson Med ; 81(1): 653-669, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29893997

RESUMEN

PURPOSE: To evaluate the local specific absorption rate (SAR) and heating around retained cardiac leads during MRI at 64 MHz (1.5T) and 127 MHz (3T) as a function of RF coil type and imaging landmark. METHODS: Numerical models of retained cardiac leads were built from CT and X-ray images of 6 patients with retained cardiac leads. Electromagnetic simulations and bio-heat modeling were performed with MRI RF body and head coils tuned to 64 MHz and 127 MHz and positioned at 9 different imaging landmarks covering an area from the head to the lower limbs. RESULTS: For all patients and at both 1.5T and 3T, local transmit head coils produced negligible temperature rise ( Δ T < 0.1 ° C ) for ‖ ‖ B 1 + ‖ ‖ ≤ 3 µ T . For body imaging with quadrature-driven coils at 1.5T, Δ T during a 10-min scan remained < 3°C at all imaging landmarks for ‖ ‖ B 1 + ‖ ‖ ≤ 3 µ T and <6°C for ‖ ‖ B 1 + ‖ ‖ ≤ 4 µ T . For body imaging at 3T, Δ T during a 10-min scan remained < 6°C at all imaging landmarks for ‖ ‖ B 1 + ‖ ‖ ≤ 2 µ T . For shorter pulse sequences up to 2 min, Δ T remained < 6°C for ‖ ‖ B 1 + ‖ ‖ ≤ 3 µ T . CONCLUSION: For the models based on 6 patients studied, simulations suggest that MRI could be performed safely using a local head coil at both 1.5T and 3T, and with a body coil at 1.5T with pulses that produced ‖ ‖ B 1 + ‖ ‖ ≤ 4 µ T . MRI at 3T could be performed safely in these patients using pulses with ‖ ‖ B 1 + ‖ ‖ ≤ 2 µ T .


Asunto(s)
Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Cuerpos Extraños , Insuficiencia Cardíaca/cirugía , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Ondas de Radio , Adulto , Algoritmos , Simulación por Computador , Femenino , Análisis de Elementos Finitos , Frecuencia Cardíaca , Trasplante de Corazón , Calor , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Pierna/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Seguridad del Paciente , Complicaciones Posoperatorias/cirugía , Prótesis e Implantes , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven