J Aging Phys Act ; 23(3): 377-82, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25102469

RESUMEN

Accelerometer step count accuracy may be affected by gait speed, device positioning, and analysis algorithm selection. We assessed ActiGraph GT3X+ step count accuracy related to device placement and analysis algorithm in older adults with walking aids (n = 13) and without walking aids (n = 22). Participants (81.5 ± 5.0 years of age) completed a timed 100-m walk wearing five GT3X+ monitors (hips, ankles, lumbar spine). Individuals with walking aids had slower gait speeds (0.8 ± 0.20 m/s versus 1.2 ± 0.20 m/s without walking aids, p < .001). Intraclass correlation coefficient values for observed versus monitored steps were highest when ankle placement and the low frequency extension (LFE) algorithm were used (left ankle ICC = .989, right ankle ICC = .998). Using the GT3X+ ankle placement and analyzing data with the LFE algorithm resulted in the most accurate step counts in older adults.


Asunto(s)
Actigrafía/instrumentación , Algoritmos , Marcha/fisiología , Acelerometría/instrumentación , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Equipo Ortopédico