Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Osteoporos Int ; 35(7): 1165-1171, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38561550

RESUMEN

Joint replacement surgery is common in older adults, leading to increasing periprosthetic fracture (PPFx) occurrence. We reviewed all PPFx seen over a 4-year period at an academic hospital. Clinical osteoporosis could be diagnosed based on existing data in 104 (67%) at the time of PPFx. Periprosthetic fractures are generally osteoporosis-related. PURPOSE: Periprosthetic fractures (PPFx) cause morbidity, mortality, and cost. This study's purpose was to describe osteoporosis-related data available at the time of PPFx. METHODS: The electronic medical record (EMR) of PPFx patients seen over 4 years in a university orthopedic practice were reviewed. Demographic data and osteoporosis relevant parameters were collected. Prior DXA studies were reviewed, and L1 Hounsfield unit (HU) measurements were performed on CT scans obtained within 2 years before PPFx. Clinical osteoporosis was defined as prior diagnosis, prescribed osteoporosis treatment, T-score ≤ - 2.5, HU ≤ 100, or prior fracture. RESULTS: Records of 156 PPFx patients (115 F/41 M), mean (SD) age 75.4 (11.9), were reviewed. Almost all 153/156 (98%) of these fractures were femoral. Falls caused 139 (89%); 12 (8%) were spontaneous. Mean time post-arthroplasty was 7.9 (6.3) years. Prior fragility fracture(s) occurred in 72 (46%); 14 were PPFx. Osteoporosis was previously diagnosed in 45 (29%) and medications prescribed in 41 (26%). Prior to PPFx, DXA data were available in 62, mean (SD) lowest T-score was - 1.9 (0.9) and was ≤ - 2.5 in 19. CT data were available in 46; mean (SD) L1 HU was 79.0 (29.4) and was ≤ 100 in 35. Based on existing data, clinical osteoporosis could have been diagnosed in 104 (67%) at the time of PPFx. CONCLUSION: Periprosthetic fractures are osteoporosis-related. They occur in older adults, often female, and result from falls; BMD, when assessed, is low. Data available at the time of PPFx often allows osteoporosis diagnosis; this should prompt evaluation and pharmacologic treatment consideration.


Asunto(s)
Absorciometría de Fotón , Osteoporosis , Fracturas Osteoporóticas , Fracturas Periprotésicas , Humanos , Fracturas Osteoporóticas/etiología , Fracturas Osteoporóticas/diagnóstico por imagen , Femenino , Anciano , Fracturas Periprotésicas/diagnóstico , Fracturas Periprotésicas/etiología , Masculino , Osteoporosis/complicaciones , Osteoporosis/diagnóstico , Absorciometría de Fotón/métodos , Anciano de 80 o más Años , Densidad Ósea/fisiología , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Erróneo/estadística & datos numéricos , Estudios Retrospectivos , Artroplastia de Reemplazo de Cadera , Conservadores de la Densidad Ósea/uso terapéutico , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla
2.
J Clin Densitom ; 27(1): 101456, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38128449

RESUMEN

INTRODUCTION: Bone density measured using dual-energy X-ray absorptiometry (DXA) volume, performance site and interpreters have changed in the US since 2005. The purpose of this report is to provide updated trends in DXA counts, rates, place of service and interpreter specialty for the Medicare fee-for-service population. METHODS: The 100 % Medicare Physician/Supplier Procedure Summary Limited Data Set between 2005-2019 was used. DXA counts and annual rates per 10,000 Medicare beneficiaries were calculated. Annual distributions of scan performance location, provider type and interpreter specialty were described. Place of service trends (significance assigned at p < 0.05) of the mean annual share of DXA utilization were identified using linear regression. RESULTS: Annual DXA use per 10,000 beneficiaries peaked in 2008 at 832, declined to 656 in 2015 then increased (p < 0.001) by 38 per year to 807 in 2019. From 2005 to 2019 DXA performance in office settings declined from 70.7 % to 47.2 %. Concurrently, outpatient hospital (OH) DXA increased from 28.6 % to 51.7 %. In 2005, 43.5 % of DXAs were interpreted by radiologists. This increased (p < 0.001) in the office and OH, averaging 0.3 and 2.0 percentage points per year respectively, reaching 73.5 % in 2019. Interpretation by most non-radiologist specialties declined (p < 0.001). CONCLUSIONS: From 2005-2019, total DXA use among Medicare beneficiaries declined reaching a nadir in 2015 then returned to 2005 levels by 2019. Office DXA declined since 2005 with 51.7 % of all scans now occurring in an OH setting. The proportion of DXAs interpreted by radiologists increased over time, reaching 73.5 % in 2019.


Asunto(s)
Medicare , Médicos , Anciano , Humanos , Estados Unidos/epidemiología , Absorciometría de Fotón , Densidad Ósea , Radiólogos
3.
J Clin Densitom ; 27(1): 101439, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38000921

RESUMEN

Incomplete atypical femur fractures (iAFFs) are associated with the long-term use of anti-resorptive therapies. Although X-rays are typically used to screen for iAFFs, images from dual-energy X-ray absorptiometry (DXA) offer an alternate method for detecting iAFFs. Although a previous 2019 ISCD Official Position on this subject exists, our task force aimed to update the literature review and to propose recommendations on reporting findings related to iAFFs that may be observed on DXA images. The task force recommended that full-length femur imaging (FFI) from DXA can be used as a screening tool for iAFFs. The presence of focal lateral cortical thickening and transverse lucencies should be reported, if identified on the FFI. This task force proposed a classification system to determine the likelihood of an iAFF, based on radiographic features seen on the FFI. Lastly, the task force recommended that the clinical assessment of prodromal symptoms (pain) is not required for the assessment of FFI.


Asunto(s)
Densidad Ósea , Sociedades Médicas , Humanos , Absorciometría de Fotón/métodos , Fémur/diagnóstico por imagen , Extremidad Inferior
4.
J Clin Densitom ; 27(1): 101437, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38011777

RESUMEN

INTRODUCTION: Professional guidance and standards assist radiologic interpreters in generating high quality reports. Initially DXA reporting Official Positions were provided by the ISCD in 2003; however, as the field has progressed, some of the current recommendations require revision and updating. This manuscript details the research approach and provides updated DXA reporting guidance. METHODS: Key Questions were proposed by ISCD established protocols and approved by the Position Development Conference Steering Committee. Literature related to each question was accumulated by searching PubMed, and existing guidelines from other organizations were extracted from websites. Modifications and additions to the ISCD Official Positions were determined by an expert panel after reviewing the Task Force proposals and position papers. RESULTS: Since most DXA is now performed in radiology departments, an approach was endorsed that better aligns with standard radiologic reports. To achieve this, reporting elements were divided into required minimum or optional. Collectively, required components comprise a standard diagnostic report and are considered the minimum necessary to generate an acceptable report. Additional elements were retained and categorized as optional. These optional components were considered relevant but tailored to a consultative, clinically oriented report. Although this information is beneficial, not all interpreters have access to sufficient clinical information, or may not have the clinical expertise to expand beyond a diagnostic report. Consequently, these are not required for an acceptable report. CONCLUSION: These updated ISCD positions conform with the DXA field's evolution over the past 20 years. Specifically, a basic diagnostic report better aligns with radiology standards, and additional elements (which are valued by treating clinicians) remain acceptable but are optional and not required. Additionally, reporting guidance for newer elements such as fracture risk assessment are incorporated. It is our expectation that these updated Official Positions will improve compliance with required standards and generate high quality DXA reports that are valuable to the recipient clinician and contribute to best patient care.


Asunto(s)
Densidad Ósea , Radiología , Humanos , Absorciometría de Fotón , Sociedades Médicas
5.
J Clin Densitom ; 27(1): 101436, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37985274

RESUMEN

The precision for spine bone mineral density (BMD) worsens as vertebrae are excluded, so recommendations are needed for least significant change (LSC) for spine BMDs based on fewer than 4 vertebrae. The task force recommends re-analysis of each facility's L1-L4 in-house precision study to determine the precision in order to calculate the LSC for each combination of 2 or 3 reported vertebrae. The task force recommended not reporting spine BMDs based on single vertebral bodies for either the diagnosis or monitoring of osteoporosis. Specific data for studies assessing the precision of two non-contiguous vertebrae are mixed, but ultimately the task force recommended that spine BMD based on 2 non-contiguous vertebrae can be used for the diagnosis and monitoring of osteoporosis.


Asunto(s)
Vértebras Lumbares , Osteoporosis , Humanos , Vértebras Lumbares/diagnóstico por imagen , Absorciometría de Fotón , Densidad Ósea , Osteoporosis/diagnóstico por imagen
6.
J Clin Densitom ; 27(1): 101438, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38030473

RESUMEN

INTRODUCTION: This position development conference (PDC) Task Force examined the use and reporting of bilateral hip bone mineral density (BMD) measurements. This was deemed appropriate as increased availability of Dual-energy X-ray Absorptiometry (DXA) technology offering bilateral hip measurement resulted in more routine clinical use. The International Society for Clinical Densitometry Official Positions accept bilateral hip BMD measurement for clinical use but currently do not include recommendations for reporting those studies. METHODS: Four key questions regarding bilateral hip reporting were proposed by the PDC Steering Committee. Relevant literature was identified using PubMed. Questions included whether bilateral hip measurements are appropriate for diagnostic classification or monitoring, as well as which bilateral hip regions of interest should be reported for diagnosis and monitoring. Additionally, the appropriate nomenclature for bilateral hip acquisition was defined. RESULTS: The literature review demonstrated that bilateral hip measurement is appropriate and diagnostic classification should be based on the lowest T-score at the right or left side femoral neck or total hip; the mean T-score should not be used for diagnostic purposes. Mean bilateral total hip is preferred for BMD monitoring. The terms hip, or total hip were deemed appropriate nomenclature instead of femur or total proximal femur. CONCLUSION: Bilateral hip acquisition is clinically appropriate and reporting and nomenclature standards are offered herein when a bilateral hip study is acquired. In terms of future research, the impact of discordant hips on diagnosis and monitoring was identified as a significant knowledge gap.


Asunto(s)
Osteoporosis , Humanos , Absorciometría de Fotón/métodos , Osteoporosis/diagnóstico por imagen , Sociedades Médicas , Densidad Ósea , Cadera/diagnóstico por imagen , Fémur
7.
Osteoporos Int ; 34(1): 171-177, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36326846

RESUMEN

This study evaluates a novel, simple bone health screening protocol composed of patient sex, age, fracture history, and FRAX risk to identify total knee arthroplasty patients for preoperative DXA. Findings supported effectiveness, with sensitivity of 1.00 (CI 0.92-1.00) and specificity of 0.54 (CI 0.41-0.68) when evaluating for clinical osteoporosis. PURPOSE: Bone health optimization is a process where osteoporotic patients are identified, evaluated via modalities such as dual-energy X-ray absorptiometry (DXA), and treated when indicated. There are currently no established guidelines to determine who needs presurgical DXA. This study evaluates the effectiveness of a simple screening protocol to identify TKA patients for preoperative DXA. METHODS: This prospective cohort study began on September 1, 2019, and included 100 elective TKA patients. Inclusion criteria were ≥ 50 years and primary TKA. All patients obtained routine clinical DXA. The screening protocol defining who should obtain DXA included meeting any of the following: female ≥ 65, male ≥ 70, fracture history after age 50, or FRAX major osteoporotic fracture risk without bone mineral density (BMD) adjustments ≥ 8.4%. Osteoporosis was defined by the World Health Organization (WHO) criteria (T-score ≤ - 2.5) or clinically (T-score ≤ - 2.5, elevated BMD-adjusted FRAX risk, or prior hip/spine fracture). Sensitivity and specificity were calculated. RESULTS: The study included 68 females and 32 males, mean age 67.2 ± 7.7. T-score osteoporosis was observed in 16 patients while 43 had clinical osteoporosis. Screening criteria recommending DXA was met by 69 patients. Screening sensitivity was 1.00 (CI 0.79-1.00) and specificity was 0.37 (CI 0.27-0.48) for identifying patients with T-score osteoporosis. Similar sensitivity of 1.00 (CI 0.92-1.00) and specificity of 0.54 (CI 0.41-0.68) were found for clinical osteoporosis. CONCLUSIONS: A simple screening protocol identifies TKA patients with T-score and clinical osteoporosis for preoperative DXA with high sensitivity in this prospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fracturas de Cadera , Osteoporosis , Fracturas Osteoporóticas , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Absorciometría de Fotón/métodos , Densidad Ósea , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Prospectivos , Osteoporosis/diagnóstico , Fracturas Osteoporóticas/etiología , Fracturas Osteoporóticas/prevención & control , Medición de Riesgo/métodos , Factores de Riesgo
8.
Osteoporos Int ; 34(6): 1093-1099, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37000208

RESUMEN

This study evaluated the intraoperative physician assessment (IPA) of bone status at time of total knee arthroplasty. IPA was highly correlated with distal femur and overall bone mineral density. When IPA identifies poor bone status, formal bone health assessment is indicated. PURPOSE: Intuitively, intraoperative physician assessment (IPA) would be an excellent measure of bone status gained through haptic feedback during bone preparation. However, no studies have evaluated the orthopedic surgeon's ability to do so. This study's purpose, in patients undergoing total knee arthroplasty (TKA), was to relate IPA with (1) the lowest bone mineral density (BMD) T-score at routine clinical sites; and (2) with distal femur BMD. METHODS: Seventy patients undergoing TKA by 3 surgeons received pre-operative DXA. Intraoperatively, bone quality was assessed on a 5-point scale (1 excellent to 5 poor) based on tactile feedback to preparation. Demographic data, DXA results, and IPA score between surgeons were compared by factorial ANOVA. Lowest T-score and distal femur BMD were associated with IPA using Spearman's correlation. RESULTS: The mean (SD) age and BMI were 65.8 (7.6) years and 31.4 (5.1) kg/m2, respectively. Patient demographic data, BMD, and IPA (mean [SD] = 2.74 [1.2]) did not differ between surgeons. IPA correlated with the lowest T-score (R = 0.511) and distal femur BMD (R = 0.603-0.661). Based on the lowest T-score, no osteoporotic patients had an IPA above average, and none with normal BMD was classified as having poor bone. CONCLUSIONS: IPA is highly correlated with local (distal femur) and overall BMD. This study supports the International Society for Clinical Densitometry position that surgeon concern regarding bone quality should lead to bone health assessment. As IPA is comparable between surgeons, it is logical this can be widely applied by experienced orthopedic surgeons. Future studies evaluating IPA at other anatomic sites are indicated.


Asunto(s)
Densidad Ósea , Médicos , Humanos , Absorciometría de Fotón/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Persona de Mediana Edad , Anciano
9.
J Clin Densitom ; 25(4): 599-605, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35430132

RESUMEN

Texture Research Imaging Platform applies trabecular bone score (TBS) measurement principles to images acquired with multiple modalities to assess bone texture at various skeletal sites. This study aimed to assess the bone texture score in dual-energy X-ray absorptiometry-acquired lateral vertebral fracture assessment (VFA) images (BTSVFA), evaluate its reproducibility, and vertebral fracture discrimination ability. Subjects included 178 VF cases and 178 non-VF controls, 136 women and 42 men in each group, age 55-92 years, from two research centers. Cases and controls were matched for age (±5 years), body mass index (±5 kg/m2) and TBS. All participants underwent dual-energy X-ray absorptiometry TBS assessment from standard posterior-anterior lumbar spine scans and BTSVFA assessment. VF presence was determined using VFA images applying the Genant's method. BTSVFA was lower among fractured women compared to non-fractured (0.626 ± 0.109 vs 0.675 ± 0.099, p < 0.01), but not among men. In a binary logistic regression adjusted for study center and sex, for each SD lower BTSVFA, there was a 40% increase (OR 1.40, 95% CI (1.13-1.74)) in the risk of having a prevalent VF; area under the curve (95% CI) 0.616 (0.557-0.675). Inter-assessor and inter-centers ICCs for BTSVFA measurements were very good; 0.96 (0.64-0.99) and 0.98 (0.95-0.99), respectively. The BTSVFA precision (coefficient of variation) was 2.42%. This feasibility study demonstrates the potential to assess trabecular bone texture in lateral VFA images with good reproducibility. BTSVFA can discriminate between fractured and non-fractured women independent of their age, body mass index and TBS. In conclusion, BTSVFA, a potential trabecular texture assessment that excludes the posterior elements, may have value in fracture prediction or as a novel approach to be further investigated in spine surgery planning.


Asunto(s)
Fracturas Óseas , Fracturas Osteoporóticas , Fracturas de la Columna Vertebral , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Fracturas de la Columna Vertebral/diagnóstico por imagen , Reproducibilidad de los Resultados , Absorciometría de Fotón/métodos , Vértebras Lumbares/diagnóstico por imagen , Densidad Ósea , Medición de Riesgo/métodos
10.
J Clin Densitom ; 25(4): 448-455, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36114106

RESUMEN

BACKGROUND: As arthroplasty leads to bone loss, we hypothesized that humeral bone mineral density (BMD) is lower after total shoulder arthroplasty (TSA) in the operative versus non-operative arm. However, there is no clinical approach to measure humeral BMD with dual-energy x-ray absorptiometry (DXA). The purposes of this pilot study were to develop DXA methodology to measure humerus BMD, propose humerus regions of interest (ROIs), compare TSA BMD to the non-operative arm, correlate humeral BMD with standard sites, and evaluate measurement reproducibility. METHODOLOGY: Thirty-eight adults 1-5 years post-TSA had standard clinical DXA scans plus full humerus scans using the atypical femur fracture feature; precision was assessed in a subset (n = 32). Six custom ROIs were used to measure BMD throughout the humerus. Radius and humeral BMD were compared between arms by paired t-test and correlated ipsilaterally using Pearson's Correlation. Custom ROI BMD precision was assessed using the International Society for Clinical Densitometry (ISCD) advanced precision calculator. RESULTS: Study included 38 subjects (24M/14F), with mean (SD) age and time post-surgery of 69.6 (7.7) years and 2.5 (1.3) years respectively. BMD was lower (p < 0.01) at all custom humerus sites (3.8% to 8.2%) on the surgical side but not different at radius sites. Humeral BMD correlated positively with ipsilateral ultra-distal and 1/3 radius (r = 0.54 to 0.86; p < 0.05). Custom BMD precision (%CV) ranged from 6.0-16.0%. CONCLUSIONS: Humerus BMD can be measured using DXA and is lower in the TSA arm. Radius BMD correlated with humeral BMD but was not lower in the surgical arm. BMD precision was worse than usual clinical sites; use of software optimized for the femur is a notable limitation and likely contributes to suboptimal precision. Further study to assess the clinical utility of humeral BMD is needed. Automation and optimization of these measurements should improve precision.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Densidad Ósea , Adulto , Humanos , Absorciometría de Fotón/métodos , Brazo , Húmero/diagnóstico por imagen , Proyectos Piloto , Reproducibilidad de los Resultados
11.
J Clin Densitom ; 25(3): 319-327, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35210129

RESUMEN

Distal femur BMD declines ∼20% following total knee arthroplasty (TKA) potentially leading to adverse outcomes. BMD knowledge before and following TKA might allow interventions to optimize outcomes. We hypothesized that distal femur and proximal tibial BMD could be reproducibly measured with existing DXA technology. Elective TKA candidates were enrolled and standard clinical DXA plus bilateral PA and lateral knee scans acquired. Manual regions of interest (ROIs) were placed at distal femur and proximal tibia sites based on required TKA machining and periprosthetic fracture location. Intra- and inter-rater BMD reliability was assessed by intra-class correlation (ICC). Custom and standard proximal femur BMD were correlated by linear regression and paired t test evaluated BMD differences between planned surgical and contralateral side. One hundred subjects (68F/32M), mean (SD) age and BMI of 67.2 (7.7) yr and 30.8 (4.8) kg/m2 were enrolled. Lowest clinical BMD T-score was < -1.0 in 65% and ≤ -2.5 in 16%; 34 had prior fracture. BMD reproducibility at all custom ROIs was excellent; ICC > 0.96. Mean BMD at custom ROIs ranged from 0.903 to 1.346 g/cm2 in the PA projection and 0.891 to 1.429 g/cm2 in the lateral. Lower BMD values were observed at the proximal tibia, while the higher measurements were at the femur condyle. Custom knee ROI BMD was highly correlated (p < 0.0001) with total and femur neck with better correlation at ROIs adjacent to the joint (R2 = 0.62-0.67, 0.49-0.55 respectively). In those without prior TKA (n = 76), mean BMD was lower (2.8%-6.6%; p < 0.05) in the planned surgical leg at all custom ROIs except the PA tibial regions. Individual variability was present with 82% having a custom ROI with lower BMD (up to 53%) in the planned operative leg. Distal femur and proximal tibial BMD can be measured using custom ROIs with good reproducibility. Suboptimal bone status is common in TKA candidates and distal femur/proximal tibia BMD is often lower on the planned operative side. Routine distal femur/proximal tibial BMD measurement might assist pre-operative interventions, surgical decision-making, subsequent care and outcomes. Studies to evaluate these possibilities are indicated.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Tibia , Absorciometría de Fotón , Densidad Ósea , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Reproducibilidad de los Resultados , Tibia/diagnóstico por imagen , Tibia/cirugía
12.
J Clin Densitom ; 25(1): 3-19, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34785102

RESUMEN

The 2021 Virtual Santa Fe Bone Symposium was held August 5-8, with over 300 registered attendees from throughout the USA, and at least 18 other countries. This annual meeting focuses on applying advances in basic science and clinical research to the care of patients with osteoporosis and those with inherited and acquired disorders of bone metabolism. Participants represented a broad range of medical disciplines with an interest in skeletal diseases. These included physicians of many specialties and practice settings, fellows, advanced practice providers, fracture liaison service (FLS) coordinators, clinical researchers, and bone density technologists. There were lectures, case presentations, and panel discussions, all followed by interactive discussions. Breakout sessions included an FLS workshop, Bone Health TeleECHO workshop, special interest groups, meet-and-greet the faculty, and satellite symposia. The agenda covered topics of interest such as strategies for the use of osteoanabolic therapy, prevention of periprosthetic fractures, management of atypical femur fractures, what we know and don't know about vitamin D, advances in the use of dual-energy X-ray absorptiometry in the assessment of skeletal health, controversies and conundrums in osteoporosis care, skeletal health in transgender patients, management of patients with hypophosphatasia and hypophosphatemia, and treat-to-target approaches for managing patients with osteoporosis. The Proceedings of the 2021 Virtual Santa Fe Bone Symposium consists of highlights of each presentation with current strategies for optimizing the care of patients with skeletal disorders.


Asunto(s)
Conservadores de la Densidad Ósea , Enfermedades Óseas Metabólicas , Osteoporosis , Fracturas Osteoporóticas , Absorciometría de Fotón , Densidad Ósea , Conservadores de la Densidad Ósea/uso terapéutico , Enfermedades Óseas Metabólicas/diagnóstico por imagen , Enfermedades Óseas Metabólicas/terapia , Huesos , Humanos , Osteoporosis/tratamiento farmacológico , Fracturas Osteoporóticas/prevención & control
13.
Acta Anaesthesiol Scand ; 66(10): 1202-1210, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36054671

RESUMEN

BACKGROUND: Despite multiple studies suggesting that low 25(OH)D-vitamin levels are associated with worse outcomes in critically ill individuals, attempts to mitigate the outcomes by fixed dose enteral supplementation unguided by baseline or target blood levels have been unsuccessful. Since a single measurement of 25(OH)D may not optimally reflect an individual's vitamin D status, we studied the plasma concentration of different vitamin D metabolites and their recovery during and following resolution of acute critical illness. METHODS: A prospective observational study including patients 18 years and older admitted to a mixed medical-surgical ICU in Reykjavik, Iceland, located at a high-northern altitude (64° N). Vitamin D metabolites were measured at three timepoints; On admission (S1), 3-5 days following admission (S2) and after recovery from acute illness (median 178 days) (S3). Concentrations of total 25(OH)D-vitamin, cholecalciferol (D3 ), total 24,25(OH)D-vitamin, vitamin D binding protein (VDBP) were measured with LC-tandem mass spectrometry (LC-MS/MS) and free 25-(OH)D was measured with enzyme-linked immunosorbent assay. RESULTS: Most individuals were vitamin D deficient when assessed during critical illness, with 25(OH)D-vitamin levels under 30 ng/ml for 37/40 individuals at timepoint S1 and 34/38 at S2. After recovery, 18/30 patients were deficient at S3. Levels of all vitamin D metabolites measured were low during critical illness but rose substantially following resolution of acute illness. No strong correlation was found between markers of acute illness severity or duration and resolution of vitamin D metabolites in the interval between acute illness and recovery. CONCLUSIONS: In critically ill patients, levels of multiple vitamin D metabolites are low but substantial recovery occurs following resolution of acute illness. It is unclear whether a single metabolite is sufficient to assess vitamin D status of critically ill patients and guide potential supplementation.


Asunto(s)
Enfermedad Crítica , Deficiencia de Vitamina D , Humanos , Proteína de Unión a Vitamina D , Cromatografía Liquida , Enfermedad Aguda , Espectrometría de Masas en Tándem , Vitamina D , Colecalciferol , Vitaminas/análisis
14.
BMC Geriatr ; 22(1): 335, 2022 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-35436920

RESUMEN

BACKGROUND: Many older adults with physical limitations living in residential care apartments are unable to exercise in a standing position and are at risk for declining in muscle function leading to falls and injury. Novel approaches to achieve exercise benefits are needed. The purpose of this study was to test the effect of semi-recumbent vibration exercise on muscle outcomes in older adults living in residential care apartment complexes (RCACs). METHODS: A randomized, crossover design was used to examine the effect of semi-recumbent vibration exercise on muscle function and mass among 32 RCAC residents (mean age 87.5 years) with physical limitations. Participants received a randomized sequence of two study conditions: sham or vibration for 8 weeks each separated by a 4-week washout. Before and after the 8 weeks of vibration treatment and sham treatment, muscle mechanography was used to assess muscle function including jump power, weight-corrected jump power, and jump height. Short physical performance battery (SPPB) and handgrip strength were also used to measure muscle function. Bioelectrical impedance spectroscopy was used to estimate skeletal muscle mass. The effect of the vibration treatment on muscle outcomes was analyzed through mixed effects linear regression models. RESULTS: Vibration exercise leads to better jump height (p < .05) compared to sham exercise but also poorer chair rise performance (p = 0.012). Other muscle functions tests and muscle mass parameters showed non-significant changes. CONCLUSION: This small pilot study showed no conclusive results on the effect of semi-recumbent vibration exercise on muscle function and mass in older adults living in RCAC. However, the promising signals of improved jump performance could be used to power larger studies of longer duration with various vibration doses to determine the benefit of vibration exercise in this physically impaired, high-risk population with few exercise capabilities. TRIAL REGISTRATION: The study is registered at clinicaltrials.gov ( NCT02533063 ; date of first registration 26/08/2015).


Asunto(s)
Fuerza de la Mano , Vibración , Anciano , Anciano de 80 o más Años , Ejercicio Físico , Fuerza de la Mano/fisiología , Humanos , Fuerza Muscular/fisiología , Músculo Esquelético , Proyectos Piloto , Vibración/uso terapéutico
15.
J Clin Densitom ; 24(2): 281-286, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32631738

RESUMEN

OBJECTIVE: Radio-dense artifacts, including contrast material, alter dual-energy X-ray absorptiometry (DXA) results. An apparent diffuse artifact was identified during spine DXA acquisition in a patient without recent radiographic procedures. The patient reported taking sodium zirconium cyclosilicate (SZC; Lokelma®) 10 g 1 h before scanning. SZC is a potassium-binding agent recently marketed to treat hyperkalemia. Given the chemical composition, we hypothesized that SZC may alter DXA results. This study evaluated if SZC affects DXA results using an encapsulated spine and a total body phantom. METHODOLOGY: An encapsulated spine and total body phantom were scanned using a Lunar iDXA. Each phantom was scanned 5 times serially without repositioning in 5 configurations: (1) Bare, (2) 45 mL tap water, (3) 90 mL water, (4) 10 g SZC in 45 mL of water, and (5) 30 g SZC in 90 mL of water. Water and SZC was contained in plastic quart bags, folded, and placed over L2-3 on the spine phantom and flat over the pelvis/torso of the total body phantom. RESULTS: Tap water did not change spine phantom measurements, but did increase (p < 0.05) total body phantom lean mass 46 g and 89 g with 45 mL and 90 mL, respectively. SZC 10 g or 30 g increased (p < 0.001) L2 and L3 bone mineral density (BMD) 18%-110%, mean 0.295 and 0.924 g/cm2, respectively, while L1 and L4 BMD was statistically, but not clinically, altered by <0.010 g/cm2. A dose-dependent change (p < 0.001) in total body phantom trunk measurements was demonstrated. The 10 g dose increased lean mass 16.8% and BMC 1%; fat mass was reduced 16.6%, while 30 g increased lean 41.9%, BMC 3.2%, and decreased fat 42.9%. CONCLUSION: SZC confounds BMD and body composition phantom measurements. It is likely that SZC alters DXA results in humans. DXA technologists and interpreters should be aware of this confounder.


Asunto(s)
Potasio , Silicatos , Absorciometría de Fotón , Densidad Ósea , Humanos , Columna Vertebral
16.
J Clin Densitom ; 22(4): 517-543, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31519473

RESUMEN

This position development conference (PDC) Task Force examined the assessment of bone status in orthopedic surgery patients. Key questions included which orthopedic surgery patients should be evaluated for poor bone health prior to surgery and which subsets of patients are at high risk for poor bone health and adverse outcomes. Second, the reliability and validity of using bone densitometry techniques and measurement of specific geometries around the hip and knee before and after arthroplasty was determined. Finally, the use of computed tomography (CT) attenuation coefficients (Hounsfield units) to estimate bone quality at anatomic locations where orthopedic surgery is performed including femur, tibia, shoulder, wrist, and ankle were reviewed. The literature review identified 665 articles of which 198 met inclusion exclusion criteria and were selected based on reporting of methodology, reliability, or validity results. We recommend that the orthopedic surgeon be aware of established ISCD guidelines for determining who should have additional screening for osteoporosis. Patients with inflammatory arthritis, chronic corticosteroid use, chronic renal disease, and those with history of fracture after age 50 are at high risk of osteoporosis and adverse events from surgery and should have dual energy X-ray absorptiometry (DXA) screening before surgery. In addition to standard DXA, bone mineral density (BMD) measurement along the femur and proximal tibia is reliable and valid around implants and can provide valuable information regarding bone remodeling and identification of loosening. Attention to positioning, selection of regions of interest, and use of special techniques and software is required. Plain radiographs and CT provide simple, reliable methods to classify the shape of the proximal femur and to predict osteoporosis; these include the Dorr Classification, Cortical Index, and critical thickness. Correlation of these indices to central BMD is moderate to good. Many patients undergoing orthopedic surgery have had preoperative CT which can be utilized to assess regional quality of bone. The simplest method available on most picture archiving and communications systems is to simply measure a regions of interest and determine the mean Hounsfield units. This method has excellent reliability throughout the skeleton and has moderate correlation to DXA based on BMD. The prediction of outcome and correlation to mechanical strength of fixation of a screw or implant is unknown.


Asunto(s)
Absorciometría de Fotón/normas , Densidad Ósea , Enfermedades Óseas/diagnóstico , Conferencias de Consenso como Asunto , Procedimientos Ortopédicos/métodos , Enfermedades Óseas/cirugía , Humanos
17.
J Arthroplasty ; 34(10): 2347-2350, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31227302

RESUMEN

BACKGROUND: Peri-prosthetic fractures after total knee arthroplasty (TKA) are associated with poorer outcomes and high costs. We hypothesize that osteoporosis is under-recognized in the TKA population. The purpose of this study is to report osteoporosis prevalence in a healthy cohort of patients with well-functioning TKA and to compare prevalence between males and females. METHODS: This study is a cross-sectional study of 30 adults (15 males/15 females) aged 59-80 years without known bone health issues who volunteered to undergo routine dual-energy X-ray absorptiometry 2-5 years (average 3.2 ± 0.8) after primary unilateral TKA. These data plus clinical risk factors were used to estimate fracture risk via the Fracture Risk Assessment Tool and skeletal status (normal, osteopenic, osteoporotic) was determined based on the World Health Organization definition. The National Osteoporosis Foundation criteria for treatment were applied to all patients. RESULTS: Six of 30 (20%) patients had T-score ≤ -2.5. Eighteen of 30 (60%) patients had T-score between -1 and -2.5 and 6 (20%) patients had T-score ≥ -1. Five patients with normal or osteopenic bone mineral density (BMD) had occult vertebral fractures. Eleven of 30 (36.7%) patients met National Osteoporosis Foundation criteria for pharmacologic treatment. CONCLUSION: The prevalence of occult osteoporosis meeting treatment guidelines after TKA is substantial in this sample (36.7%). BMD and osteoporosis prevalence are similar between men and women. This underappreciated prevalence of osteoporosis may contribute to peri-prosthetic fracture risk. Arthroplasty surgeons and bone health specialists must be aware of post-operative changes in bone density. These data support the further study of post-operative osteoporosis and consideration of routine BMD screening after TKA. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteoporosis/complicaciones , Osteoporosis/cirugía , Absorciometría de Fotón , Adulto , Anciano , Anciano de 80 o más Años , Densidad Ósea , Estudios Transversales , Femenino , Cadera/patología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Reoperación , Factores de Riesgo , Columna Vertebral , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA