Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Neuroimaging ; 33(4): 521-526, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36978252

RESUMEN

BACKGROUND AND PURPOSE: Magnetic resonance imaging (MRI) plays a key role in diagnosing and monitoring multiple sclerosis (MS). Double inversion recovery (DIR) is a pulse sequence that has proven highly effective at detecting cortical lesions but is understudied in the spinal cord. We hypothesize that DIR images obtained during brain MRI can be of value in assessing the upper spinal cord of MS patients. METHODS: We retrospectively examined brain MRI exams of 64 patients with established MS, who had also undergone cervical spine MRI. Two blinded MS expert readers, who assessed the scans for lesion numbers and rated lesion visibility and overall image quality, reviewed brain 3-dimensional DIR sagittal and coronal images. Standardized mean contrast-to-noise ratios (C/N) and standard deviation (SD) were calculated in representative lesions for each patient and compared to those of 3-dimensional FLAIR images. RESULTS: For the analysis of lesions categorized as "definite lesions," the sensitivity was 87%, specificity was 61%, and negative predictive value was 80%. On the other hand, for "definite" plus "probable" lesions, the sensitivity was 91%, the specificity was 54%, and negative predictive value was 86%. DIR demonstrated lesions with an average C/N of 7.56 with an SD of 1.77. FLAIR sequence demonstrated lesions with an average C/N of 0.67 and SD of 1.27. CONCLUSIONS: Sagittally acquired brain DIR can provide useful information on upper spinal cord lesions, with high C/N. In theory, this should facilitate the attainment of McDonald's or the Magnetic Resonance Imaging in MS (MAGNIMS) criteria in some cases, without a dedicated cervical spine MRI exam.


Asunto(s)
Médula Cervical , Esclerosis Múltiple , Humanos , Esclerosis Múltiple/patología , Médula Cervical/diagnóstico por imagen , Médula Cervical/patología , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Médula Espinal/diagnóstico por imagen , Médula Espinal/patología
2.
Nat Commun ; 12(1): 2239, 2021 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-33854063

RESUMEN

Enhancers are transcription factor platforms that synergize with promoters to control gene expression. Here, we investigate enhancers that activate gene expression several hundred-fold exclusively in the lactating mouse mammary gland. Using ChIP-seq for activating histone marks and transcription factors, we identify two candidate enhancers and one super-enhancer in the Csn1s2b locus. Through experimental mouse genetics, we dissect the lactation-specific distal enhancer bound by the mammary-enriched transcription factors STAT5 and NFIB and the glucocorticoid receptor. While deletions of canonical binding motifs for NFIB and STAT5, individually or combined, have a limited biological impact, a non-canonical STAT5 site is essential for enhancer activity during lactation. In contrast, the intronic enhancer contributes to gene expression only in late pregnancy and early lactation, possibly by interacting with the distal enhancer. A downstream super-enhancer, which physically interacts with the distal enhancer, is required for the functional establishment of the Csn1s2b promoter and gene activation. Lastly, NFIB binding in the promoter region fine-tunes Csn1s2b expression. Our study provides comprehensive insight into the anatomy and biology of regulatory elements that employ the JAK/STAT signaling pathway and preferentially activate gene expression during lactation.


Asunto(s)
Elementos de Facilitación Genéticos , Regulación de la Expresión Génica , Lactancia/genética , Glándulas Mamarias Animales/metabolismo , Ratones/genética , Animales , Citocinas/metabolismo , Femenino , Lactancia/metabolismo , Ratones/metabolismo , Factores de Transcripción NFI/genética , Factores de Transcripción NFI/metabolismo , Embarazo , Regiones Promotoras Genéticas , Receptores de Glucocorticoides/genética , Receptores de Glucocorticoides/metabolismo , Factor de Transcripción STAT5/genética , Factor de Transcripción STAT5/metabolismo , Transducción de Señal
3.
Nat Commun ; 8: 15464, 2017 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-28561021

RESUMEN

Although CRISPR/Cas9 genome editing has provided numerous opportunities to interrogate the functional significance of any given genomic site, there is a paucity of data on the extent of molecular scars inflicted on the mouse genome. Here we interrogate the molecular consequences of CRISPR/Cas9-mediated deletions at 17 sites in four loci of the mouse genome. We sequence targeted sites in 632 founder mice and analyse 54 established lines. While the median deletion size using single sgRNAs is 9 bp, we also obtain large deletions of up to 600 bp. Furthermore, we show unreported asymmetric deletions and large insertions of middle repetitive sequences. Simultaneous targeting of distant loci results in the removal of the intervening sequences. Reliable deletion of juxtaposed sites is only achieved through two-step targeting. Our findings also demonstrate that an extended analysis of F1 genotypes is required to obtain conclusive information on the exact molecular consequences of targeting events.


Asunto(s)
Sistemas CRISPR-Cas/genética , Edición Génica/métodos , Genoma/genética , Eliminación de Secuencia/genética , Animales , Femenino , Genotipo , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , ARN Guía de Kinetoplastida/genética
4.
Biosens Bioelectron ; 77: 188-93, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26406460

RESUMEN

Herein we report a low cost, sensitive, supercapacitor-powered electrochemiluminescent (ECL) protein immunoarray fabricated by an inexpensive 3-dimensional (3D) printer. The immunosensor detects three cancer biomarker proteins in serum within 35 min. The 3D-printed device employs hand screen printed carbon sensors with gravity flow for sample/reagent delivery and washing. Prostate cancer biomarker proteins, prostate specific antigen (PSA), prostate specific membrane antigen (PSMA) and platelet factor-4 (PF-4) in serum were captured on the antibody-coated carbon sensors followed by delivery of detection-antibody-coated Ru(bpy)3(2+) (RuBPY)-doped silica nanoparticles in a sandwich immunoassay. ECL light was initiated from RuBPY in the silica nanoparticles by electrochemical oxidation with tripropylamine (TPrA) co-reactant using supercapacitor power and ECL was captured with a CCD camera. The supercapacitor was rapidly photo-recharged between assays using an inexpensive solar cell. Detection limits were 300-500f gmL(-1) for the 3 proteins in undiluted calf serum. Assays of 6 prostate cancer patient serum samples gave good correlation with conventional single protein ELISAs. This technology could provide sensitive onsite cancer diagnostic tests in resource-limited settings with the need for only moderate-level training.


Asunto(s)
Conductometría/instrumentación , Suministros de Energía Eléctrica , Inmunoensayo/instrumentación , Mediciones Luminiscentes/instrumentación , Impresión Tridimensional , Análisis por Matrices de Proteínas/instrumentación , Capacidad Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA