Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Clin Oral Investig ; 28(5): 247, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38602599

RESUMEN

OBJECTIVES: There is a paucity of information about the possible risk factors that could identify patients with Robin sequence (RS) who are more prone to developing obstructive airway complications after palate closure. This study aimed to compare the respiratory complication rates in patients with RS and isolated cleft palate (ICP). MATERIALS AND METHODS: In this retrospective study, we reviewed the medical records of 243 consecutive patients with RS and ICP who were treated at Amsterdam University Medical Centers over the past 25 years. We collected preoperative data on previous treatment, diagnostic findings, surgical technique, weight, and presence of congenital anomalies. RESULTS: During cleft palate closure, patients with RS were older (11.9 versus 10.1 months; p = 0.001) and had a lower gestational age than those with ICP (37.7 versus 38.5 weeks; p = 0.002). Patients with RS had more respiratory complications (17 versus 5%; p = 0.005), were more often non-electively admitted to the pediatric intensive care unit (PICU) (13 versus 4.1%; p = 0.022), and had a longer hospital stay duration (3.7 versus 2.7 days; p = 0.011) than those with ICP. The identified risk factors for respiratory problems were a history of tongue-lip-adhesion (TLA) (p = 0.007) and a preoperative weight of < 8 kg (p = 0.015). Similar risk factors were identified for PICU admission (p = 0.015 and 0.004, respectively). CONCLUSIONS: The possible risk factors for these outcomes were a low preoperative weight and history of TLA. Closer postoperative surveillance should be considered for patients with these risk factors. CLINICAL RELEVANCE: Identifying risk factors for respiratory complications could provide clinicians better insight into their patients and allows them to provide optimal care for their patients.


Asunto(s)
Fisura del Paladar , Síndrome de Pierre Robin , Humanos , Lactante , Fisura del Paladar/cirugía , Hospitalización , Síndrome de Pierre Robin/complicaciones , Síndrome de Pierre Robin/cirugía , Estudios Retrospectivos , Lengua
2.
J Pediatr Orthop ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38666494

RESUMEN

BACKGROUND: The Oberg-Manske-Tonkin (OMT) classification established excellent reliability scores in several validation studies. However, one study published in 2022 found much lower scores in a subanalysis of their sample when very simple anomalies were excluded. Our study assessed the reliability of the OMT among physicians with a different background, all involved in congenital hand anomaly care, and analyzed codes with less agreement. Time required for classification was recorded to give an indication on its usability. METHODS: One hundred digital cases were classified twice with a minimal 1-month time interval, with the use of the 2020 version of the OMT. Two pediatric hand surgeons, 2 rehabilitation specialists, and 2 plastic surgery residents participated in this reliability analysis. The use of multiple codes was allowed. The intra- and interrater reliability was assessed for all 15 possible rater couples by calculating percentage of agreement. Cohen's kappa was calculated along with a 95% confidence interval. For the analysis of individual codes with less agreement, we calculated positive agreement with the use of a summed agreement table. Time necessary for classification was documented in seconds. RESULTS: The inter- and intrarater agreement was moderate with a mean Cohen's kappa of 0.45 and 0.60 retrospectively. On average, 39 seconds per case were necessary for the first and 24 seconds for the second rating. Background did not influence the level of agreement. Lowest agreement levels (ie, lowest positive agreement) were observed with all the arthrogryposis multiplex congenita subgroups, the "other" subgroups of isolated congenital contractures, syndromic syndactyly, and synpolydactyly. Codes commonly used interchangeably were symbrachydactyly and transverse deficiency and the distinction between these anomalies of only the hand or the entire upper limb; symbrachydactyly and brachydactyly; and camptodactyly and distal arthrogryposis. CONCLUSIONS: Our study showed a moderate reliability, emphasizing the complexity of this heterogeneous patient population. Despite its imperfections, the OMT remains the best and most versatile classification tool at hand. Its main purpose may lie in contributing to a universal language for research. LEVEL OF EVIDENCE: I.

3.
J Craniofac Surg ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38861198

RESUMEN

INTRODUCTION: Although the maxillary nerve block (MNB) provides adequate pain relief in cleft palate surgery, it is not routinely used globally, and reported techniques are heterogeneous. This study aims to describe relevant anatomy and to present the preferred technique of MNB administration based on the current literature and the expert opinion of the authors. METHOD AND MATERIALS: First, a survey was sent to 432 registrants of the International Cleft Palate Master Course Amsterdam 2023. Second, MEDLINE (PubMed interface) was searched for relevant literature on maxillary artery (MA) anatomy and MNB administration in pediatric patients. RESULTS: Survey response rate was 18% (n=78). Thirty-five respondents (44.9%) used MNB for cleft palate surgery before the course. A suprazygomatic approach with needle reorientation towards the ipsilateral commissure before incision was most frequently reported, mostly without the use of ultrasound. Ten and 20 articles were included on, respectively, MA anatomy and MNB administration. A 47.5% to 69.4% of the MA's run superficial to the lateral pterygoid muscle and 32% to 52.5% medially. The most frequently described technique for MNB administration is the suprazygomatic approach. Reorientation of the needle towards the anterior aspect of the contralateral tragus appears optimal. Needle reorientation angles do not have to be adjusted for age, unlike needle depth. The preferred anesthetics are either ropivacaine or (levo)bupivacaine, with dexmedetomidine as an adjuvant. CONCLUSION: Described MNB techniques are heterogeneous throughout the literature and among survey respondents and not routinely used. Further research is required comparing different techniques regarding efficacy and safety.

4.
Eur J Pediatr ; 182(3): 1271-1280, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36633656

RESUMEN

The goal of this study was to explore the availability of diagnostic and treatment options for managing upper airway obstruction (UAO) in infants with Robin Sequence (RS) in Europe. Countries were divided in lower- (LHECs, i.e., PPP per capita < $4000) and higher-health expenditure countries (HHECs, i.e., PPP per capita ≥ $4000). An online survey was sent to European healthcare professionals who treat RS. The survey was designed to determine the availability of diagnostic tools such as arterial blood gas analysis (ABG), pulse oximetry, CO2 analysis, polysomnography (PSG), and sleep questionnaires, as well as to identify the used treatment options in a specific center. Responses were received from professionals of 85 centers, originating from 31 different countries. It was equally challenging to provide care for infants with RS in both LHECs and HHECs (3.67/10 versus 2.65/10, p = 0.45). Furthermore, in the LHECs, there was less access to ABG (85% versus 98%, p = 0.03), CO2 analysis (45% versus 70%, p = 0.03), and PSG (54% versus 93%, p < 0.01). There were no significant differences in the accessibility concerning pulse oximetry, sleep questionnaires, home saturation monitoring, nasopharyngeal tubes, Tuebingen plates, and mandibular distraction.    Conclusion: This study demonstrates a large difference in available care for infants with RS throughout Europe. LHECs have less access to diagnostic tools in RS when compared to HHECs. There is, however, no difference in the availability of treatment modalities between LHECs and HHECs. What is Known: • Patients with Robin sequence (RS) require complex and multidisciplinary care. They can present with moderate to severe upper airway obstruction (UAO). There exists a large variety in the use of diagnostics for both UAO treatment indications and evaluations. In most cases, conservative management of UAO in RS is sufficient. Patients with UAO that persist despite conservative management ultimately need surgical intervention. To determine which intervention is best suitable for the individual RS patient, the level of UAO needs to be determined through diagnostic testing. • There is a substantial variation among institutions across Europe for both diagnostics and treatment options in UAO. A standardized, internationally accepted protocol for the assessment and management of UAO in RS could guide healthcare professionals in the timing of assessment and indications to prevent escalation of UAO. Creating such a protocol might be a challenge, as there are large financial differences between countries in Europe (e.g., health expenditure per capita in purchasing power parity in international dollars ranges from $600 to over $8500). What is New: • There is a substantial variation in the availability of objective diagnostic tools between European countries. Arterial blood gas analysis, CO2 analysis and polysomnography are not equally accessible for lower-healthcare expenditure countries (LHECs) compared to higher-healthcare expenditure countries (HHECs). These differences are not only limited to availability; there is also a difference in quality of these diagnostic tools. Surprisingly, there is no difference in access to treatment tools between LHECs and HHECs. • There is national heterogeneity in access to tools for diagnosis and treatment of RS, which suggests centralization of health care, showing that specialized care is only available in tertiary centers. By centralization of care for RS infants, diagnostics and treatment can be optimized in the best possible way to create a uniform European protocol and ultimately equal care across Europe. Learning what is necessary for adequate monitoring could lead to better allocation of resources, which is especially important in a low-resource setting.


Asunto(s)
Obstrucción de las Vías Aéreas , Síndrome de Pierre Robin , Lactante , Humanos , Obstrucción de las Vías Aéreas/diagnóstico , Obstrucción de las Vías Aéreas/etiología , Obstrucción de las Vías Aéreas/terapia , Síndrome de Pierre Robin/diagnóstico , Síndrome de Pierre Robin/terapia , Dióxido de Carbono , Europa (Continente) , Mandíbula/cirugía , Estudios Retrospectivos
5.
Stroke ; 50(6): 1590-1594, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31136287

RESUMEN

Background and Purpose- We developed a rat model of silent brain infarcts based on microsphere infusion and investigated their impact on perfusion and tissue damage. Second, we studied the extent and mechanisms of perfusion recovery. Methods- At day 0, 15 µm fluorescent microspheres were injected into the right common carotid artery of F344 rats. At days 1, 7, or 28, the brain was removed, cut in 100-µm cryosections, and processed for immunofluorescent staining and analysis. Results- Injection of microspheres caused mild and transient damage to the treated hemisphere, with a decrease in perfused capillary volume at day 1, as compared with the untreated hemisphere. At day 1 but not at days 7 and 28, we observed IgG staining outside of the vessels, indicating vessel leakage. All microspheres were located inside the lumen of the vessels at day 1, whereas the vast majority (≈80%) of the microspheres were extravascular at day 7, and 100% at day 28. This was accompanied by restoration of perfused capillary volume. Conclusions- Microspheres cause mild and transient damage, and effective extravasation mechanisms exist in the brain to clear microsized emboli from the vessels.


Asunto(s)
Infarto Encefálico , Microesferas , Animales , Infarto Encefálico/inducido químicamente , Infarto Encefálico/metabolismo , Infarto Encefálico/patología , Modelos Animales de Enfermedad , Masculino , Ratas , Ratas Endogámicas F344
6.
J Vasc Res ; 52(2): 103-15, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26184661

RESUMEN

Vasospasm is known to contribute to delayed cerebral ischemia following subarachnoid hemorrhage (SAH). We hypothesized that vasospasm initiates structural changes within the vessel wall, possibly aggravating ischemia and leading to resistance to vasodilator treatment. We therefore investigated the effect of blood on cerebral arteries with respect to contractile activation and vascular remodeling. In vitro experiments on rodent basilar and middle cerebral arteries showed a gradual contraction in response to overnight exposure to blood. After incubation with blood, a clear inward remodeling was found, reducing the caliber of the passive vessel. The transglutaminase inhibitor L682.777 fully prevented this remodeling. Translation of the in vitro findings to an in vivo SAH model was attempted in rats, using both a single prechiasmatic blood injection model and a double cisterna magna injection model, and in mice, using a single prechiasmatic blood injection. However, we found no substantial changes in active or passive biomechanical properties in vivo. We conclude that extravascular blood can induce matrix remodeling in cerebral arteries, which reduces vascular caliber. This remodeling depends on transglutaminase activity. However, the current rodent SAH models do not permit in vivo confirmation of this mechanism.


Asunto(s)
Arteria Cerebral Media/fisiopatología , Hemorragia Subaracnoidea/fisiopatología , Remodelación Vascular , Vasoespasmo Intracraneal/fisiopatología , Animales , Fenómenos Biomecánicos , Velocidad del Flujo Sanguíneo , Circulación Cerebrovascular , Modelos Animales de Enfermedad , Inhibidores Enzimáticos/farmacología , Proteínas de Unión al GTP/antagonistas & inhibidores , Proteínas de Unión al GTP/genética , Proteínas de Unión al GTP/metabolismo , Masculino , Ratones Endogámicos C57BL , Ratones Noqueados , Arteria Cerebral Media/efectos de los fármacos , Arteria Cerebral Media/enzimología , Arteria Cerebral Media/patología , Proteína Glutamina Gamma Glutamiltransferasa 2 , Ratas Wistar , Flujo Sanguíneo Regional , Hemorragia Subaracnoidea/enzimología , Hemorragia Subaracnoidea/genética , Hemorragia Subaracnoidea/patología , Transglutaminasas/antagonistas & inhibidores , Transglutaminasas/genética , Transglutaminasas/metabolismo , Remodelación Vascular/efectos de los fármacos , Vasoconstricción , Vasoespasmo Intracraneal/enzimología , Vasoespasmo Intracraneal/genética , Vasoespasmo Intracraneal/patología
7.
Artif Organs ; 38(12): 998-1006, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24750025

RESUMEN

A major challenge for a wearable dialysis device is removal of urea, as urea is difficult to adsorb while daily production is very high. Electro-oxidation (EO) seems attractive because electrodes are durable, small, and inexpensive. We studied the efficacy of urea oxidation, generation of chlorine by-products, and their removal by activated carbon (AC). EO units were designed. Three electrode materials (platinum, ruthenium oxide, and graphite) were compared in single pass experiments using urea in saline solution. Chlorine removal by AC in series with EO by graphite electrodes was tested. Finally, urea-spiked bovine blood was dialyzed and dialysate was recirculated in a dialysate circuit with AC in series with an EO unit containing graphite electrodes. Platinum electrodes degraded more urea (21 ± 2 mmol/h) than ruthenium oxide (13 ± 2 mmol/h) or graphite electrodes (13 ± 1 mmol/h). Chlorine generation was much lower with graphite (13 ± 4 mg/h) than with platinum (231 ± 22 mg/h) or ruthenium oxide electrodes (129 ± 12 mg/h). Platinum and ruthenium oxide electrodes released platinum (4.1 [3.9-8.1] umol/h) and ruthenium (83 [77-107] nmol/h), respectively. AC potently reduced dialysate chlorine levels to < 0.10 mg/L. Urea was removed from blood by EO at constant rate (9.5 ± 1.0 mmol/h). EO by graphite electrodes combined with AC shows promising urea removal and chlorine release complying with Association for the Advancement of Medical Instrumentation standards, and may be worth further exploring for dialysate regeneration in a wearable system.


Asunto(s)
Diálisis Renal/instrumentación , Urea/sangre , Animales , Bovinos , Soluciones para Diálisis , Electrodos , Oxidación-Reducción
8.
Sci Rep ; 14(1): 10760, 2024 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-38729983

RESUMEN

Measurement of auricle parameters for planning and post-operative evaluation presents substantial challenges due to the complex 3D structure of the human auricle. Traditional measurement methods rely on manual techniques, resulting in limited precision. This study introduces a novel automated surface-based three-dimensional measurement method for quantifying human auricle parameters. The method was applied to virtual auricles reconstructed from Computed Tomography (CT) scans of a cadaver head and subsequent measurement of important clinically relevant aesthetical auricular parameters (length, width, protrusion, position, auriculocephalic angle, and inclination angle). Reference measurements were done manually (using a caliper and using a 3D landmarking method) and measurement precision was compared to the automated method. The CT scans were performed using both a contemporary high-end and a low-end CT scanner. Scans were conducted at a standard scanning dose, and at half the dose. The automatic method demonstrated significantly higher precision in measuring auricle parameters compared to manual methods. Compared to traditional manual measurements, precision improved for auricle length (9×), width (5×), protrusion (5×), Auriculocephalic Angle (5-54×) and posteroanterior position (23×). Concerning parameters without comparison with a manual method, the precision level of supero-inferior position was 0.489 mm; and the precisions of the inclination angle measurements were 1.365 mm and 0.237 mm for the two automated methods investigated. Improved precision of measuring auricle parameters was associated with using the high-end scanner. A higher dose was only associated with a higher precision for the left auricle length. The findings of this study emphasize the advantage of automated surface-based auricle measurements, showcasing improved precision compared to traditional methods. This novel algorithm has the potential to enhance auricle reconstruction and other applications in plastic surgery, offering a promising avenue for future research and clinical application.


Asunto(s)
Algoritmos , Pabellón Auricular , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Pabellón Auricular/diagnóstico por imagen , Pabellón Auricular/anatomía & histología , Tomografía Computarizada por Rayos X/métodos , Imagenología Tridimensional/métodos , Cadáver , Masculino
9.
J Plast Reconstr Aesthet Surg ; 88: 320-323, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38052126

RESUMEN

INTRODUCTION: Traditional on-site missions of plastic surgeons from "high-income countries" in "low- and middle-income countries" are often limited in time and lack proper follow-up. Regular digital collaboration could lead to a more impactful and durable exchange of knowledge for plastic surgeons and residents in both settings. AIMS: The aim of this study was to evaluate the satisfaction of the first twelve months of weekly digital meetings, explore advantages/disadvantages, and to provide tools for similar initiatives. METHODS: Weekly meetings started from August 2021. An encrypted digital connection allowed residents and plastic surgeons from Uganda and the Netherlands to discuss cases for educational purposes, where treatment options were considered. After twelve months, a survey was sent to participants from both countries to indicate the meetings' strengths, weaknesses, and possible improvements. RESULTS: A total of 18 participants responded to the questionnaire (ten plastic surgeons, six residents, and two researchers). The strengths of the meetings were the accessibility of the meetings, knowledge exchange and practice for residents' final exams. Possible improvements included having a clear format for patient discussion, a session moderator and better internet connectivity. Moreover, a database to assess the impact of the given intervention on the patient cases by evaluating postoperatively (e.g. three months), could further improve clinical care. CONCLUSIONS: Virtual patient discussions subjectively contributed to medical education at both locations. Improved digital infrastructure and a collaborative database could further maximize learning capacity. Furthermore, digital proctoring is a promising way to establish sustainable collaborations between high- and low-resource countries.


Asunto(s)
Educación Médica , Cirujanos , Humanos , Países Bajos , Uganda , Atención al Paciente
10.
JPRAS Open ; 38: 65-81, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37719440

RESUMEN

Background: Commonly used methods to evaluate auricles are subjective and are therefore not specific, comprehensive, and precise nor effective in the assessment of microtia reconstruction outcomes. This scoping review aimed to summarize the objective methods for the accurate evaluation of microtia reconstruction. Methods: We performed a scoping review of publications that used objective measurement methods to evaluate outcomes of microtia reconstruction according to the PRISMA-ScR guidelines. A systematic literature search was conducted in the Embase, PubMed, Cochrane, CNKI, and VIP databases, and literature references were screened for additional records. Studies that evaluated auricles after microtia reconstruction using quantitative anthropometric methods were included, and data on these methods were collected. Results: Twenty-five publications reported on quantitative objective outcome measurements. Thirteen studies evaluated auricular protrusion, three articles assessed the position or symmetry, and twelve studies reported on auricle size. The quantitative measurements of fine structures, such as the tragus and concha, were described in three studies. All described measurements used manual landmarking, where fifteen studies described well-defined landmarks, fifteen studies described poorly defined landmarks, and four studies used a combination of well and poorly defined landmarks. Conclusion: The objective evaluation of microtia reconstruction outcomes is hindered by significant heterogeneity of measurement methods. The measurement methods used for general auricular measurements (auricular protrusion, auriculocephalic angle, and size) used in microtia reconstruction were abundant, while measurements of auricular position and the fine structures of the auricle were limited. Three-dimensional imaging combined with computer analyses poses promising future alternatives.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA