Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

2.
J Clin Pharmacol ; 43(4): 359-64, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12723456

RESUMEN

Tegaserod (HTF 919), a selective 5-HT4 receptor partial agonist with promotile activity throughout the gastrointestinal tract, is in development for the treatment of irritable bowel syndrome. In an open-label, parallel-group study, the pharmacokinetics of a single 12-mg oral dose of tegaserod in patients with severe renal insufficiency requiring hemodialysis were compared with data obtained from healthy subjects matched for age, weight, height, and gender (n = 10, both). The pharmacokinetics of tegaserod were similar in both groups (AUC(0h-tz), ng.h/ml: 14.6 +/- 8.5 vs. 14.3 +/- 7.1; Cmax, ng/ml: 4.6 +/- 2.3 vs. 5.1 +/- 2.2; tmax, h: 1.0, for both). Tegaserod had similar tolerability in renally impaired patients and healthy volunteers, with adverse events largely related to the gastrointestinal pharmacological actions of the drug. Therefore, no dose adjustment of tegaserod is necessary for patients with renal insufficiency.


Asunto(s)
Indoles/farmacocinética , Fallo Renal Crónico/metabolismo , Receptores de Serotonina/efectos de los fármacos , Agonistas de Receptores de Serotonina/farmacocinética , Administración Oral , Adulto , Anciano , Área Bajo la Curva , Femenino , Humanos , Indoles/administración & dosificación , Indoles/efectos adversos , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Receptores de Serotonina 5-HT4 , Diálisis Renal , Agonistas de Receptores de Serotonina/administración & dosificación , Agonistas de Receptores de Serotonina/efectos adversos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA