Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Langenbecks Arch Surg ; 406(8): 2749-2757, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34076718

RESUMEN

PURPOSE: Microwave ablation (MWA) is an accepted technique in the multimodal treatment of hepatocellular carcinoma (HCC) and colorectal liver metastases (CRLM). Study endpoints were to evaluate the local efficacy of surgical MWA in selected patients with oligonodular disease without the combination of liver resection to allow a clear interpretation of the follow-up imaging and compare it to the results on percutaneous MWA available in the literature. METHODS: Consecutive MWA-only procedures performed between May 2013 and May 2018 for HCC and CRLM with free-hand ultrasound guidance were identified. MWA systems with 2450 MHz were used. Incomplete ablation (IA) was defined as residual disease within 1 cm of the ablation site at the first post-ablation imaging and local recurrence (LR) as the presence of disease after at least one tumor-free imaging. RESULTS: A total of 70 tumors in 47 patients were treated with 46 laparoscopic and 1 open procedures. Each patient had no more than 3 tumors, and median size of the lesions was 15 mm (IQR: 10-22). After a median follow-up of 26 months (IQR: 12-40), IA rate was 8.6% and LR rate was 29.4%. Multivariable analysis showed that vascular proximity (OR = 3.4; 95% CI = 1.26-9.22; p=0.016) was the only significant predictor of the combined outcome IA or LR. DISCUSSION: In the present study, after mostly laparoscopic MWA, LR was higher than the rates available in the literature for percutaneous MWA of HCC but lower than in the limited studies analyzing isolated percutaneous MWA of liver metastases. Future developments may help establish the role of each therapeutic modality per tumor, in order to improve the outcomes.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Colorrectales , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Hepatectomía , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Microondas/uso terapéutico , Resultado del Tratamiento
2.
Acta Radiol ; 60(6): 679-686, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30185070

RESUMEN

BACKGROUND: Assessment of Crohn's disease (CD) activity is important to identify patients with active inflammation for therapy management. Quantitative analysis can provide objective measurement of disease presence. PURPOSE: To evaluate the feasibility of quantitative analysis of contrast-enhanced dual-energy computed tomography (DECT) data in detection of small bowel inflammation in patients with CD with an emphasis on iodine quantification. MATERIAL AND METHODS: DECT enterography was prospectively performed in 20 patients with active CD and in 20 healthy individuals, as the control group. Iodine overlay images were created. Wall thickness, attenuation, absolute iodine density, relative iodine density, and fat fraction were measured in the terminal ileum of all patients by two radiologists. Intraclass correlation coefficients were calculated to assess inter-rater agreement. Parameters were compared between patient groups using mixed model analysis. Receiver operating characteristic (ROC) analysis was performed. RESULTS: Both absolute and relative iodine density were significantly higher in active disease than in normal small bowel (all P < 0.001). In contrast, measurement of fat fraction was not significantly different in affected terminal ileal loops compared to normal terminal ileum ( P = 0.075). ROC analysis demonstrated a similar excellent diagnostic accuracy of wall thickness, attenuation, and absolute and relative iodine density with area under the ROC curve (AUC) values in the range of 0.96 for attenuation to 1 for relative iodine density. CONCLUSION: DECT with iodine quantification can be used in distinguishing normal small bowel from active inflammatory CD. Further research should investigate the value of iodine quantification in grading CD activity and in monitoring therapeutic response.


Asunto(s)
Medios de Contraste , Enfermedad de Crohn/diagnóstico por imagen , Intestino Delgado/diagnóstico por imagen , Yodo , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Estudios de Casos y Controles , Enfermedad de Crohn/patología , Diagnóstico Diferencial , Estudios de Factibilidad , Femenino , Humanos , Intestino Delgado/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos
3.
HPB (Oxford) ; 21(5): 557-565, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30314713

RESUMEN

BACKGROUND: Excessive increase of portal flow and pressure following extended hepatectomy have been associated to insufficient growth or function of the future liver remnant (FLR), with the risk of post-hepatectomy liver failure (PHLF). We prospectively assess the influence of liver hemodynamics on FLR regeneration and function in Associating Liver Partition and Portal vein ligation for Staged hepatectomy (ALPPS). METHODS: Twenty-three patients underwent ALPPS; liver hemodynamics were assessed throughout the procedures. Volume and function of the FLR were evaluated by angio-CT and 99mTc-Mebrofenin-scintigraphy. RESULTS: The portal vein flow at the end of stage-1 correlated with the increase of the FLR volume (p = 0.002). Patients with portal vein pressure (PVP) < 20 mmHg and hepatic to portal vein gradients (HVPG) < 15 mmHg at the end of ALPPS-1 showed higher FLR regeneration (76.7% vs. 30.6%, p = 0.04) and function (26.7% vs. -0.13%, p = 0.02). FLR regeneration was inversely correlated with baseline FLR/Total Liver Volume (p = 0.002) and FLR/Body Weight (p = 0.02). No correlation was found between volumes and function (p = 0.13). CONCLUSION: Liver hemodynamic stress at the end of ALPPS-1 influences the increase of the FLR volume and function, which is higher with PVP < 20 and HVPG < 15 mmHg. Liver volume overestimates liver function and could be imprecise to set stage-2 timing.


Asunto(s)
Hemodinámica , Hepatectomía , Neoplasias Hepáticas/cirugía , Regeneración Hepática , Anciano , Femenino , Humanos , Hígado/irrigación sanguínea , Hígado/cirugía , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Tempo Operativo , Vena Porta/cirugía , Complicaciones Posoperatorias , Estudios Prospectivos
4.
Case Rep Gastroenterol ; 12(1): 13-18, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29515340

RESUMEN

We report the case of a young woman with hereditary hemorrhagic telangiectasia (HHT) with severe liver involvement and pulmonary shunting. The medical imaging in this patient illustrates the severe shunting that can occur in these patients who often are asymptomatic. By showing this case, we want to highlight the role of liver transplantation in HHT with hepatic involvement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA