Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Nanotechnology ; 28(18): 185603, 2017 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-28393764

RESUMEN

We present facile synthesis of bright CdS/CdSe/CdS@SiO2 nanoparticles with 72% of quantum yields (QYs) retaining ca 80% of the original QYs. The main innovative point is the utilization of the highly luminescent CdS/CdSe/CdS seed/spherical quantum well/shell (SQW) as silica coating seeds. The significance of inorganic semiconductor shell passivation and structure design of quantum dots (QDs) for obtaining bright QD@SiO2 is demonstrated by applying silica encapsulation via reverse microemulsion method to three kinds of QDs with different structure: CdSe core and 2 nm CdS shell (CdSe/CdS-thin); CdSe core and 6 nm CdS shell (CdSe/CdS-thick); and CdS core, CdSe intermediate shell and 5 nm CdS outer shell (CdS/CdSe/CdS-SQW). Silica encapsulation inevitably results in lower photoluminescence quantum yield (PL QY) than pristine QDs due to formation of surface defects. However, the retaining ratio of pristine QY is different in the three silica coated samples; for example, CdSe/CdS-thin/SiO2 shows the lowest retaining ratio (36%) while the retaining ratio of pristine PL QY in CdSe/CdS-thick/SiO2 and SQW/SiO2 is over 80% and SQW/SiO2 shows the highest resulting PL QY. Thick outermost CdS shell isolates the excitons from the defects at surface, making PL QY relatively insensitive to silica encapsulation. The bright SiO2-coated SQW sample shows robustness against harsh conditions, such as acid etching and thermal annealing. The high luminescence and long-term stability highlights the potential of using the SQW/SiO2 nanoparticles in bio-labeling or display applications.

2.
Surg Radiol Anat ; 35(6): 463-9, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23296841

RESUMEN

PURPOSE: The palatal mucosa is a major donor site for connective tissue in the field of periodontal plastic surgery, since it satisfies both the esthetic and functional demands of patients. The purpose of this study was to use histomorphometric analysis to measure the thicknesses of the palatal mucosa and the lamina propria including the epithelium on cadavers. METHODS: Thirty-four hemimaxillae of cadavers were examined (13 male and 4 female, mean age 57.2 years). Each maxilla was processed for histological sectioning and subsequently for histomorphometric analysis. The thicknesses of the palatal mucosa and the lamina propria including the epithelium were measured at three points starting from the alveolar crest, at intervals of 4 mm, with the aid of Adobe Photoshop. RESULTS: The thickness of the palatal mucosa at the alveolar crest and at 4 and 8 mm below the alveolar crest were 2.51 ± 0.83 (mean ± SD), 2.92 ± 0.80, and 3.62 ± 0.99 mm, respectively, and thus increasing from the alveolar crest toward the midpalatal suture. Conversely, the thicknesses of the lamina propria including the epithelium at these same positions were 2.06 ± 0.70, 1.54 ± 0.48, and 1.28 ± 0.46 mm, respectively, thus decreasing toward the midpalatal suture. CONCLUSIONS: The present results indicate that clinicians need to be particularly careful when harvesting palatal mucosa that is destined to be used as autogenous donor material for connective tissue in periodontal plastic surgery.


Asunto(s)
Maxilar/patología , Mucosa Bucal/patología , Mucosa Bucal/trasplante , Hueso Paladar/patología , Periodoncio/cirugía , Cirugía Plástica/métodos , Adulto , Anciano , Análisis de Varianza , Cadáver , Tejido Conectivo/trasplante , Femenino , Humanos , Inmunohistoquímica , Masculino , Maxilar/cirugía , Persona de Mediana Edad , Procedimientos Quirúrgicos Orales/métodos , Hueso Paladar/cirugía , Periodoncia/métodos , Recolección de Tejidos y Órganos
3.
Biomaterials ; 24(13): 2257-66, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12699662

RESUMEN

Ti and Ti-based alloys have been widely used for the biomedical applications due to their superiorities of biocompatibility, mechanical properties and corrosion resistance. However, there has been the limiting factor for these metals to show the low affinity to the living bone. Most of commercially used Ti alloys have harmful alloying elements such as Al, V, etc. The purposes of this study are design of new Ti alloy having the good mechanical properties and corrosion resistivity without harmful alloying elements and to improve the bone-bonding ability between Ti-based alloy and living bone through the chemically activated process (alkali treatment) and thermally activated one (heat treatment). Mechanical properties of the Ti-In-Nb-Ta alloy were observed by tensile test (Instron model 8511). Corrosion potential and corrosion rate were investigated using a Potentiostate machine (EG&G, Princeton Applied Model 273, Boston, USA) with saline solution (9% NaCl) without dissolved oxygen at 37 degrees C. After alkali and heat treatments, the effects of the pre-treatments on the bonding property were evaluated by in vitro test. In this study, the surface changing behavior, which is apatite formation, of newly designed Ti-In-Nb-Ta alloy without harmful alloying elements was investigated through analyzing its surface by using X-ray photoelectron spectroscopy after surface activation treatments (alkali and heat treatments) and after subsequent soaking in the simulated body fluid.


Asunto(s)
Aleaciones/química , Líquidos Corporales/química , Materiales Biocompatibles Revestidos/química , Ensayo de Materiales , Espectrometría por Rayos X , Álcalis/química , Aleaciones/síntesis química , Materiales Biocompatibles Revestidos/síntesis química , Corrosión , Elasticidad , Calor , Materiales Manufacturados , Microscopía Electrónica de Rastreo , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción
4.
J Biomed Mater Res A ; 69(2): 279-85, 2004 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-15058000

RESUMEN

The geometric design and chemical compositions of an implant surface may have an important part in affecting early implant stabilization and influencing tissue healing. In this study, in vivo behavior and mechanical stability in implants of three surface designs, which were smooth surface (SS), rough titanium (Ti) surface by plasma spray coating (PSC), and alkali- and heat-treated (AHT) Ti surface after plasma spray coating, were compared by histological and mechanical analyses. Surface morphologies of the implants were observed by optical microscopy and scanning electron microscopy. Chemical compositional surface changes were investigated by energy dispersive spectroscopy. The implants were inserted transversely in a dog thighbone and evaluated at 4 weeks of healing. At 4 weeks of healing after implantation in bone, the healing tissue was more extensively integrated with an AHT implant than with the implants of smooth (SS) and/or rough Ti surfaces (PSC). The bone bonding strength (pull-out force) between living bone and implant was observed by a universal testing machine. At 4 weeks' healing after implant placement in bone, the pull-out forces of the SS, PSC, and AHT implants were 235 (+/-34.25), 710 (+/-142.25), and 823 (+/-152.22) N, respectively. Histological and mechanical data demonstrate that appropriate surface design selection can improve early bone growth and induce an acceleration of the healing response, thereby improving the potential for implant osseointegration.


Asunto(s)
Sustitutos de Huesos , Materiales Biocompatibles Revestidos , Prótesis e Implantes , Titanio , Animales , Regeneración Ósea , Perros , Durapatita , Calor , Microscopía Electrónica de Rastreo , Estrés Mecánico
5.
Acta Biomater ; 8(5): 1693-702, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22306825

RESUMEN

For cell transplantation into damaged tissues, viable cells must be delivered to the defect site in a suitable carrier. However, the hypoxic and nutrient-limited environment in the carrier can induce massive cell death. The aims of this study were to increase the viability and regulate the behavior of osteoprogenitor cells encapsulated in alginate hydrogels through control of the gel microstructure. Cell survivability in alginate beads was improved through the use of α-MEM as the solvent for alginic acid sodium salt, and by CaCl(2) solutions, which supplied additional nutrients for the cells compared to water or buffer. The mesh size and shear modulus of the hydrogel were hypothesized to regulate proliferation and differentiation of osteoprogenitor cells. MC3T3-E1 cells demonstrated enhanced osteoblast differentiation when encapsulated in high-density alginate with smaller mesh size and more rigid mechanical properties, as confirmed by increased alkaline phosphatase activity and osteocalcin secretion. However, MC3T3-E1 cells encapsulated in low-density alginate beads with a larger mesh size and more compliant mechanical properties exhibited increased proliferation. These results demonstrate that the microstructure of alginate hydrogels can regulate the behavior of osteoprogenitor cells, thus suggesting that the tuning the properties of the gel may be a useful approach for enhancing new bone formation.


Asunto(s)
Alginatos/química , Geles/química , Osteoblastos/citología , Osteoblastos/fisiología , Osteogénesis/fisiología , Ingeniería de Tejidos/métodos , Andamios del Tejido , Células 3T3 , Animales , Diferenciación Celular , Proliferación Celular , Ácido Glucurónico/química , Ácidos Hexurónicos/química , Ensayo de Materiales , Ratones
6.
J Orthop Trauma ; 25(8): 477-82, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21738070

RESUMEN

OBJECTIVE: To determine if a dual-purpose bone graft can regenerate bone and reduce infection in highly contaminated bone critical size defects in rats. METHODS: Biodegradable polyurethane (PUR) scaffolds were loaded with recombinant human bone morphogenetic protein-2 (BMP-2) and vancomycin (Vanc). The release kinetics of the BMP-2 were tuned to take advantage of its mechanism of action (ie, an initial burst to recruit cells and sustained release to induce differentiation of the migrating cells). The Vanc release kinetics were designed to protect the graft from contamination until it is vascularized by having a burst for a week and remaining well over the minimum inhibitory concentration for Staphylococcus aureus for 2 months. The bone regeneration and infection reduction capability of these dual-purpose grafts (PUR+Vanc+BMP-2) were compared with collagen sponges loaded with BMP-2 (collagen+BMP-2) and PUR+BMP-2 in infected critical size rat femoral segmental defects. RESULTS: The dual-delivery approach resulted in substantially more new bone formation and a modest improvement in infection than PUR+BMP-2 and collagen+BMP-2 treatments. CONCLUSIONS: The PUR bone graft is injectable, provides a more sustained release of BMP-2 than the collagen sponge, and can release antibiotics for more than 8 weeks. Thus, the dual-delivery approach may improve patient outcomes of open fractures by protecting the osteoinductive graft from colonization until vascularization occurs. In addition, the more optimal release kinetics of BMP-2 may reduce nonunions and the amount of growth factor required.


Asunto(s)
Proteína Morfogenética Ósea 2/administración & dosificación , Trasplante Óseo/efectos adversos , Trasplante Óseo/métodos , Fracturas del Fémur/terapia , Regeneración Tisular Dirigida/métodos , Osteítis/prevención & control , Vancomicina/administración & dosificación , Animales , Antibacterianos/administración & dosificación , Trasplante Óseo/instrumentación , Terapia Combinada , Preparaciones de Acción Retardada/administración & dosificación , Fracturas del Fémur/diagnóstico , Fracturas del Fémur/fisiopatología , Curación de Fractura/efectos de los fármacos , Regeneración Tisular Dirigida/efectos adversos , Osteítis/diagnóstico , Ratas , Andamios del Tejido , Resultado del Tratamiento
7.
ACS Appl Mater Interfaces ; 1(7): 1520-4, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20355955

RESUMEN

A new process, laser-induced precursor formation and subsequent aging in a supersaturated calcium phosphate aqueous solution (CP solution), was applied for coating a hydroxyapatite (HAP) film on a polymeric material, ethylene-vinyl alcohol copolymer (EVOH). Laser irradiation onto EVOH immersed in the CP solution induced the formation of CP precursors, and an HAP film composed of a submicrometer-scale cavernous structure was formed by subsequent aging in a CP solution without laser irradiation. The resulting HAP film coated on EVOH demonstrated excellent structural and chemical uniformity and cell adhesion with the CHO-K1 and BHK-21 cells. This process provides a practical technique for coating HAP onto polymeric materials.


Asunto(s)
Durapatita/química , Polímeros/química , Animales , Células CHO , Adhesión Celular , Línea Celular , Materiales Biocompatibles Revestidos/química , Cricetinae , Cricetulus , Rayos Láser , Microscopía Electrónica de Transmisión/métodos , Polivinilos/química , Propiedades de Superficie , Factores de Tiempo
8.
Nanotechnology ; 19(41): 415303, 2008 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-21832643

RESUMEN

We demonstrate an approach for the coating of nanostructured hydroxyapatite(HAP)/TiO(2) composite on commercially pure Ti (CP-Ti) by a co-sputtering process. HAP/TiO(2) composite film was obtained by controlling the processing pressure. It was observed that decomposition of HAP into CaO was easily induced during sputtering at 0.53 Pa, a typical sputtering condition for film deposition. However, HAP/TiO(2) composite film was obtained with the sputtering pressure of 2.67 Pa. The Ca/P ratio was nearly maintained at 1.66 by sputter deposition at 2.67 Pa. We further confirmed by analysis of plasma spectral emission that the variation of the hydroxyl (OH) radical present was due to the Ar pressure during sputtering. It has been shown that HAP coatings are dependent on the processing pressure, which the hydroxyl radical requires in order to create HAP.

9.
J Biomed Mater Res ; 61(3): 466-73, 2002 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-12115472

RESUMEN

Pure titanium and titanium alloys are normally used for orthopedic and dental prostheses. Nevertheless, their chemical, biological, and mechanical properties still can be improved by the development of new preparation technologies. This has been the limiting factor for these metals to show low affinity to living bone. The purpose of this study is to improve the bone-bonding ability between titanium alloys and living bone through a chemically activated process and a thermally activated one. Two kinds of titanium alloys, a newly designed Ti-In-Nb-Ta alloy and a commercially available Ti-6Al-4V ELI alloy, were used in this study. In this study, surface modification of the titanium alloys by alkali and heat treatments (AHT), alkali treated in 5.0M NaOH solution, and heat treated in vacuum furnace at 600 degrees C, is reported. After AHT, the effects of the AHT on the bone integration property were evaluated in vitro. Surface morphologies of AHT were observed by optical microscopy (OM) and scanning electron microscopy (SEM). Chemical compositional surface changes were investigated by X-ray diffractometry (XRD), energy dispersive spectroscopy (EDS), and auger electron spectroscopy (AES). Titanium alloys with surface modification by AHT showed improved bioactive behavior, and the Ti-In-Nb-Ta alloy had better bioactivity than the Ti-6Al-4V ELI alloy in vitro.


Asunto(s)
Aleaciones/síntesis química , Materiales Biocompatibles/síntesis química , Titanio , Álcalis/química , Sangre , Sustitutos de Huesos , Tampones (Química) , Calor , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Oseointegración , Análisis Espectral , Propiedades de Superficie , Titanio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA