Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Hum Brain Mapp ; 43(7): 2148-2163, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35076125

RESUMEN

The glutamate and γ-aminobutyric acid neuroreceptor subtypes mGluR5 and GABAA are hypothesized to be involved in the development of a variety of psychiatric diseases. However, detailed information relating to their in vivo distribution is generally unavailable. Maps of such distributions could potentially aid clinical studies by providing a reference for the normal distribution of neuroreceptors and may also be useful as covariates in advanced functional magnetic resonance imaging (MR) studies. In this study, we propose a comprehensive processing pipeline for the construction of standard space, in vivo distributions of non-displaceable binding potential (BPND ), and total distribution volume (VT ) based on simultaneously acquired bolus-infusion positron emission tomography (PET) and MR data. The pipeline was applied to [11 C]ABP688-PET/MR (13 healthy male non-smokers, 26.6 ± 7.0 years) and [11 C]Flumazenil-PET/MR (10 healthy males, 25.8 ± 3.0 years) data. Activity concentration templates, as well as VT and BPND atlases of mGluR5 and GABAA , were generated from these data. The maps were validated by assessing the percent error δ from warped space to native space in a selection of brain regions. We verified that the average δABP  = 3.0 ± 1.0% and δFMZ  = 3.8 ± 1.4% were lower than the expected variabilities σ of the tracers (σABP  = 4.0%-16.0%, σFMZ  = 3.9%-9.5%). An evaluation of PET-to-PET registrations based on the new maps showed higher registration accuracy compared to registrations based on the commonly used [15 O]H2 O-template distributed with SPM12. Thus, we conclude that the resulting maps can be used for further research and the proposed pipeline is a viable tool for the construction of standardized PET data distributions.


Asunto(s)
Tomografía de Emisión de Positrones , Receptores de GABA-A , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Mapeo Encefálico/métodos , Humanos , Imagen por Resonancia Magnética , Masculino , Tomografía de Emisión de Positrones/métodos , Receptores de GABA-A/metabolismo , Ácido gamma-Aminobutírico/metabolismo
2.
J Neurooncol ; 159(3): 519-529, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35852737

RESUMEN

PURPOSE: To investigate the potential of radiomics applied to static clinical PET data using the tracer O-(2-[18F]fluoroethyl)-L-tyrosine (FET) to differentiate treatment-related changes (TRC) from tumor progression (TP) in patients with gliomas. PATIENTS AND METHODS: One hundred fifty-one (151) patients with histologically confirmed gliomas and post-therapeutic progressive MRI findings according to the response assessment in neuro-oncology criteria underwent a dynamic amino acid PET scan using the tracer O-(2-[18F]fluoroethyl)-L-tyrosine (FET). Thereof, 124 patients were investigated on a stand-alone PET scanner (data used for model development and validation), and 27 patients on a hybrid PET/MRI scanner (data used for model testing). Mean and maximum tumor to brain ratios (TBRmean, TBRmax) were calculated using the PET data from 20 to 40 min after tracer injection. Logistic regression models were evaluated for the FET PET parameters TBRmean, TBRmax, and for radiomics features of the tumor areas as well as combinations thereof to differentiate between TP and TRC. The best performing models in the validation dataset were finally applied to the test dataset. The diagnostic performance was assessed by receiver operating characteristic analysis. RESULTS: Thirty-seven patients (25%) were diagnosed with TRC, and 114 (75%) with TP. The logistic regression model comprising the conventional FET PET parameters TBRmean and TBRmax resulted in an AUC of 0.78 in both the validation (sensitivity, 64%; specificity, 80%) and the test dataset (sensitivity, 64%; specificity, 80%). The model combining the conventional FET PET parameters and two radiomics features yielded the best diagnostic performance in the validation dataset (AUC, 0.92; sensitivity, 91%; specificity, 80%) and demonstrated its generalizability in the independent test dataset (AUC, 0.85; sensitivity, 81%; specificity, 70%). CONCLUSION: The developed radiomics classifier allows the differentiation between TRC and TP in pretreated gliomas based on routinely acquired static FET PET scans with a high diagnostic accuracy.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagen , Glioma/patología , Humanos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Tirosina
3.
J Radiol Prot ; 42(2)2022 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-35705007

RESUMEN

The objective of the work described is the development of a software tool to provide the calculation routines for structural radiation protection from positron and gamma emitters, for example,18F. The calculation of the generated local annual dose in the vicinity of these radioactive sources supports the engineering of structural measures necessary to meet regulatory guidelines. In addition to accuracy and precision, a visual and intuitive presentation of the calculation results enables fast evaluation. Finally, the calculated results are presented in a contour plot for design, evaluation, and documentation purposes. A python program was used to provide the calculation routines for structural radiation protection. For simplicity, the radiating sources can be considered as point sources. The attenuation of structural elements can be specified or, in the case of lead, calculated by virtue of its thickness. The calculated attenuation for the lead shielding is always slightly underestimated, which leads to a marginally higher calculated local dose rate than would be physically present. With the conservatively determined value, the structural radiation protection can be optimised in accordance with the general rule of as low as reasonably achievable. The pointwise comparison between the software results and the standard procedure for calculating the dose of points in space leads to similar values. In comparison with the general approach of calculating single representative points in the radiation protection area, the visual and intuitive presentation of the results supports the design and documentation of the measures required for structural radiation protection. In the present version of the software, the local dose rate and local annual dose are overestimated by a maximum of 4.5% in the case of lead shields. The proposed software, termed RadSoft, was successfully used to develop the structural radiation protection of a controlled area for hybrid magnetic resonance - positron emission tomography imaging, with the focus herein being on the requirements for PET.


Asunto(s)
Exposición a la Radiación , Protección Radiológica , Tomografía de Emisión de Positrones , Dosis de Radiación , Exposición a la Radiación/prevención & control , Protección Radiológica/métodos , Radiografía , Programas Informáticos
4.
Hum Brain Mapp ; 42(13): 4122-4133, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-30367727

RESUMEN

Simultaneous trimodal positron emission tomography/magnetic resonance imaging/electroencephalography (PET/MRI/EEG) resting state (rs) brain data were acquired from 10 healthy male volunteers. The rs-functional MRI (fMRI) metrics, such as regional homogeneity (ReHo), degree centrality (DC) and fractional amplitude of low-frequency fluctuations (fALFFs), as well as 2-[18F]fluoro-2-desoxy-d-glucose (FDG)-PET standardised uptake value (SUV), were calculated and the measures were extracted from the default mode network (DMN) regions of the brain. Similarly, four microstates for each subject, showing the diverse functional states of the whole brain via topographical variations due to global field power (GFP), were estimated from artefact-corrected EEG signals. In this exploratory analysis, the GFP of microstates was nonparametrically compared to rs-fMRI metrics and FDG-PET SUV measured in the DMN of the brain. The rs-fMRI metrics (ReHO, fALFF) and FDG-PET SUV did not show any significant correlations with any of the microstates. The DC metric showed a significant positive correlation with microstate C (rs  = 0.73, p = .01). FDG-PET SUVs indicate a trend for a negative correlation with microstates A, B and C. The positive correlation of microstate C with DC metrics suggests a functional relationship between cortical hubs in the frontal and occipital lobes. The results of this study suggest further exploration of this method in a larger sample and in patients with neuropsychiatric disorders. The aim of this exploratory pilot study is to lay the foundation for the development of such multimodal measures to be applied as biomarkers for diagnosis, disease staging, treatment response and monitoring of neuropsychiatric disorders.


Asunto(s)
Corteza Cerebral , Conectoma/métodos , Red en Modo Predeterminado , Electroencefalografía/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Biomarcadores , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/fisiología , Red en Modo Predeterminado/diagnóstico por imagen , Red en Modo Predeterminado/fisiología , Humanos
5.
Hum Brain Mapp ; 41(10): 2762-2781, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32150317

RESUMEN

Consistent findings postulate disturbed glutamatergic function (more specifically a hypofunction of the ionotropic NMDA receptors) as an important pathophysiologic mechanism in schizophrenia. However, the role of the metabotropic glutamatergic receptors type 5 (mGluR5) in this disease remains unclear. In this study, we investigated their significance (using [11 C]ABP688) for psychopathology and cognition in male patients with chronic schizophrenia and healthy controls. In the patient group, lower mGluR5 binding potential (BPND ) values in the left temporal cortex and caudate were associated with higher general symptom levels (negative and depressive symptoms), lower levels of global functioning and worse cognitive performance. At the same time, in both groups, mGluR5 BPND were significantly lower in smokers (F[27,1] = 15.500; p = .001), but without significant differences between the groups. Our findings provide support for the concept that the impaired function of mGluR5 underlies the symptoms of schizophrenia. They further supply a new perspective on the complex relationship between tobacco addiction and schizophrenia by identifying glutamatergic neurotransmission-in particularly mGluR5-as a possible connection to a shared vulnerability.


Asunto(s)
Núcleo Caudado , Disfunción Cognitiva , Receptor del Glutamato Metabotropico 5/metabolismo , Esquizofrenia , Lóbulo Temporal , Adulto , Núcleo Caudado/diagnóstico por imagen , Núcleo Caudado/metabolismo , Núcleo Caudado/fisiopatología , Enfermedad Crónica , Disfunción Cognitiva/etiología , Disfunción Cognitiva/metabolismo , Disfunción Cognitiva/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Oximas/farmacocinética , Tomografía de Emisión de Positrones , Piridinas/farmacocinética , Esquizofrenia/complicaciones , Esquizofrenia/metabolismo , Esquizofrenia/fisiopatología , Fumar/metabolismo , Lóbulo Temporal/diagnóstico por imagen , Lóbulo Temporal/metabolismo , Lóbulo Temporal/fisiopatología
6.
PLoS One ; 19(4): e0296357, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38578749

RESUMEN

OBJECTIVE: Quantitative values derived from PET brain images are of high interest for neuroscientific applications. Insufficient DT correction (DTC) can lead to a systematic bias of the output parameters obtained by a detailed analysis of the time activity curves (TACs). The DTC method currently used for the Siemens 3T MR BrainPET insert is global, i.e., differences in DT losses between detector blocks are not considered, leading to inaccurate DTC and, consequently, to inaccurate measurements masked by a bias. However, following careful evaluation with phantom measurements, a new block-pairwise DTC method has demonstrated a higher degree of accuracy compared to the global DTC method. APPROACH: Differences between the global and the block-pairwise DTC method were studied in this work by applying several radioactive tracers. We evaluated the impact on [11C]ABP688, O-(2-[18F]fluoroethyl)-L-tyrosine (FET), and [15O]H2O TACs. RESULTS: For [11C]ABP688, a relevant bias of between -0.0034 and -0.0053 ml/ (cm3 • min) was found in all studied brain regions for the volume of distribution (VT) when using the current global DTC method. For [18F]FET-PET, differences of up to 10% were observed in the tumor-to-brain ratio (TBRmax), these differences depend on the radial distance of the maximum from the PET isocenter. For [15O]H2O, differences between +4% and -7% were observed in the GM region. Average biases of -4.58%, -3.2%, and -1.2% for the regional cerebral blood flow (CBF (K1)), the rate constant k2, and the volume of distribution VT were observed, respectively. Conversely, in the white matter region, average biases of -4.9%, -7.0%, and 3.8% were observed for CBF (K1), k2, and VT, respectively. CONCLUSION: The bias introduced by the global DTC method leads to an overestimation in the studied quantitative parameters for all applications compared to the block-pairwise method. SIGNIFICANCE: The observed differences between the two DTC methods are particularly relevant for research applications in neuroscientific studies as they affect the accuracy of quantitative Brain PET images.


Asunto(s)
Encéfalo , Oximas , Tomografía de Emisión de Positrones , Piridinas , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Fantasmas de Imagen , Cabeza , Imagen por Resonancia Magnética
7.
Neurology ; 102(9): e209271, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38630966

RESUMEN

BACKGROUND AND OBJECTIVES: Clinical heterogeneity of patients with Parkinson disease (PD) is well recognized. PD with REM sleep behavior disorder (RBD) is a more malignant phenotype with faster motor progression and higher nonmotor symptom burden. However, the neural mechanisms underlying this clinical divergence concerning imbalances in neurotransmitter systems remain elusive. METHODS: Combining magnetic resonance (MR) spectroscopy and [11C]ABP688 PET on a PET/MR hybrid system, we simultaneously investigated two different mechanisms of glutamate signaling in patients with PD. Patients were grouped according to their RBD status in overnight video-polysomnography and compared with age-matched and sex-matched healthy control (HC) participants. Total volumes of distribution (VT) of [11C]ABP688 were estimated with metabolite-corrected plasma concentrations during steady-state conditions between 45 and 60 minutes of the scan following a bolus-infusion protocol. Glutamate, glutamine, and glutathione levels were investigated with single-voxel stimulated echo acquisition mode MR spectroscopy of the left basal ganglia. RESULTS: We measured globally elevated VT of [11C]ABP688 in 16 patients with PD and RBD compared with 17 patients without RBD and 15 HC participants (F(2,45) = 5.579, p = 0.007). Conversely, glutamatergic metabolites did not differ between groups and did not correlate with the regional VT of [11C]ABP688. VT of [11C]ABP688 correlated with the amount of REM sleep without atonia (F(1,42) = 5.600, p = 0.023) and with dopaminergic treatment response in patients with PD (F(1,30) = 5.823, p = 0.022). DISCUSSION: Our results suggest that patients with PD and RBD exhibit altered glutamatergic signaling indicated by higher VT of [11C]ABP688 despite unaffected glutamate levels. The imbalance of glutamate receptors and MR spectroscopy glutamate metabolite levels indicates a novel mechanism contributing to the heterogeneity of PD and warrants further investigation of drugs targeting mGluR5.


Asunto(s)
Enfermedad de Parkinson , Piridinas , Trastorno de la Conducta del Sueño REM , Humanos , Enfermedad de Parkinson/diagnóstico , Trastorno de la Conducta del Sueño REM/diagnóstico , Oximas , Glutamatos
8.
Phys Med Biol ; 68(2)2023 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-36595256

RESUMEN

Objective. The positron range is a fundamental, detector-independent physical limitation to spatial resolution in positron emission tomography (PET) as it causes a significant blurring of underlying activity distribution in the reconstructed images. A major challenge for positron range correction methods is to provide accurate range kernels that inherently incorporate the generally inhomogeneous stopping power, especially at tissue boundaries. In this work, we propose a novel approach to generate accurate three-dimensional (3D) blurring kernels both in homogenous and heterogeneous media to improve PET spatial resolution.Approach. In the proposed approach, positron energy deposition was approximately tracked along straight paths, depending on the positron stopping power of the underlying material. The positron stopping power was derived from the attenuation coefficient of 511 keV gamma photons according to the available PET attenuation maps. Thus, the history of energy deposition is taken into account within the range of kernels. Special emphasis was placed on facilitating the very fast computation of the positron annihilation probability in each voxel.Results. Positron path distributions of18F in low-density polyurethane were in high agreement with Geant4 simulation at an annihilation probability larger than 10-2∼ 10-3of the maximum annihilation probability. The Geant4 simulation was further validated with measured18F depth profiles in these polyurethane phantoms. The tissue boundary of water with cortical bone and lung was correctly modeled. Residual artifacts from the numerical computations were in the range of 1%. The calculated annihilation probability in voxels shows an overall difference of less than 20% compared to the Geant4 simulation.Significance. The proposed method is expected to significantly improve spatial resolution for non-standard isotopes by providing sufficiently accurate range kernels, even in the case of significant tissue inhomogeneities.


Asunto(s)
Electrones , Poliuretanos , Tomografía Computarizada por Rayos X , Tomografía de Emisión de Positrones/métodos , Simulación por Computador , Fantasmas de Imagen
9.
EJNMMI Res ; 13(1): 11, 2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36757553

RESUMEN

BACKGROUND: For positron emission tomography (PET) ligands, such as [11C]ABP688, to be able to provide more evidence about the glutamatergic hypothesis in schizophrenia (SZ), quantification bias during dynamic PET studies and its propagation into the estimated values of non-displaceable binding potential (BPND) must be addressed. This would enable more accurate quantification during bolus + infusion (BI) neuroreceptor studies and further our understanding of neurological diseases. Previous studies have shown BPND-related biases can often occur due to overestimated cerebellum activity (reference region). This work investigates whether an alternative framing scheme can minimize quantification biases propagated into BPND, whether confounders, such as smoking status, need to be controlled for during the study, and what the consequences for the data interpretation following analysis are. A group of healthy controls (HC) and a group of SZ patients (balanced and unbalanced number of smokers) were investigated with [11C]ABP688 and a BI protocol. Possible differences in BPND quantification as a function of smoking status were tested with constant 5 min ('Const 5 min') and constant true counts ('Const Trues') framing schemes. In order to find biomarkers for SZ, the differences in smoking effects were compared between groups. The normalized BPND and the balanced number of smokers and non-smokers for both framing schemes were evaluated. RESULTS: When applying F-tests to the 'Const 5 min' framing scheme, effect sizes (η2p) and brain regions which showed significant effects fluctuated considerably with F = 50.106 ± 54.948 (9.389 to 112.607), P-values 0.005 to < 0.001 and η2p = 0.514 ± 0.282 (0.238 to 0.801). Conversely, when the 'Const Trues' framing scheme was applied, the results showed much smaller fluctuations with F = 78.038 ± 8.975 (86.450 to 68.590), P < 0.001 for all conditions and η2p = 0.730 ± 0.017 (0.742 to 0.710), and regions with significant effects were more robustly reproduced. Further, differences, which would indicate false positive identifications between HC and SZ groups in five brain regions when using the 'Const 5 min' framing scheme, were not observed with the 'Const Trues' framing. CONCLUSIONS: Based on an [11C]ABP688 PET study in SZ patients, the results show that non-consistent BPND outcomes can be propagated by the framing scheme and that potential bias can be minimized using 'Const Trues' framing.

10.
Cancers (Basel) ; 15(14)2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37509252

RESUMEN

Advanced MRI methods and PET using radiolabelled amino acids provide valuable information, in addition to conventional MR imaging, for brain tumour diagnostics. These methods are particularly helpful in challenging situations such as the differentiation of malignant processes from benign lesions, the identification of non-enhancing glioma subregions, the differentiation of tumour progression from treatment-related changes, and the early assessment of responses to anticancer therapy. The debate over which of the methods is preferable in which situation is ongoing, and has been addressed in numerous studies. Currently, most radiology and nuclear medicine departments perform these examinations independently of each other, leading to multiple examinations for the patient. The advent of hybrid PET/MRI allowed a convergence of the methods, but to date simultaneous imaging has reached little relevance in clinical neuro-oncology. This is partly due to the limited availability of hybrid PET/MRI scanners, but is also due to the fact that PET is a second-line examination in brain tumours. PET is only required in equivocal situations, and the spatial co-registration of PET examinations of the brain to previous MRI is possible without disadvantage. A key factor for the benefit of PET/MRI in neuro-oncology is a multimodal approach that provides decisive improvements in the diagnostics of brain tumours compared with a single modality. This review focuses on studies investigating the diagnostic value of combined amino acid PET and 'advanced' MRI in patients with cerebral gliomas. Available studies suggest that the combination of amino acid PET and advanced MRI improves grading and the histomolecular characterisation of newly diagnosed tumours. Few data are available concerning the delineation of tumour extent. A clear additive diagnostic value of amino acid PET and advanced MRI can be achieved regarding the differentiation of tumour recurrence from treatment-related changes. Here, the PET-guided evaluation of advanced MR methods seems to be helpful. In summary, there is growing evidence that a multimodal approach can achieve decisive improvements in the diagnostics of cerebral gliomas, for which hybrid PET/MRI offers optimal conditions.

11.
Front Neurosci ; 17: 1027697, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37766785

RESUMEN

Introduction: The fMRI BOLD response to emotional stimuli highlighting the role of the medial prefrontal cortex (MPFC) has been thoroughly investigated. Recently, the relationship between emotion processing and GABA levels has been studied using MPFC proton magnetic resonance spectroscopy (1H-MRS). However, the role of GABAA receptors in the MPFC during emotion processing remains unexplored. Methods: Using [11C]flumazenil PET, we investigated the relationship between the binding potential of GABAA receptors and emotion processing as measured using simultaneous fMRI BOLD. We hypothesized a correlation between the percent signal change in the BOLD signal and the binding potential of GABAA receptors in the MPFC. In a combined simultaneous fMRI and [11C]flumazenil-PET study, we analyzed the data from 15 healthy subjects using visual emotional stimuli. Our task comprised two types of emotional processing: passive viewing and appraisal. Following the administration of a bolus plus infusion protocol, PET and fMRI data were simultaneously acquired in a hybrid 3 T MR-BrainPET. Results: We found a differential correlation of BOLD percent signal change with [11C]flumazenil binding potential in the MPFC. Specifically, [11C]flumazenil binding potential in the ventromedial prefrontal cortex (vMPFC) correlated with passive viewing of emotionally valenced pictures. In contrast, the [11C]flumazenil binding potential and the BOLD signal induced by picture appraisal did show a correlation in the paracingulate gyrus. Conclusion: Our data deliver first evidence for a relationship between MPFC GABAA receptors and emotion processing in the same region. Moreover, we observed that GABAA receptors appear to play different roles in emotion processing in the vMPFC (passive viewing) and paracingulate gyrus (appraisal).

12.
IEEE Rev Biomed Eng ; PP2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-37015609

RESUMEN

Simultaneously operating MR-PET systems have the potential to provide synergetic multi-parametric information, and, as such, interest surrounding their use and development is increasing. However, despite the potential advantages offered by fully combined MR-PET systems, implementing this hybrid integration is technically laborious, and any factors degrading the quality of either modality must be circumvented to ensure optimal performance. In order to attain the best possible quality from both systems, most full MR-PET integrations tend to place the shielded PET system inside the MRI system, close to the target volume of the subject. The radiofrequency (RF) coil used in MRI systems is a key factor in determining the quality of the MR images, and, in simultaneous acquisition, it is generally positioned inside the PET system and PET imaging region, potentially resulting in attenuation and artefacts in the PET images. Therefore, when designing hybrid MR-PET systems, it is imperative that consideration be given to the RF coils inside the PET system. In this review, we present current state-of-the-art RF coil designs used for hybrid MR-PET experiments and discuss various design strategies for constructing PET transparent RF coils.

13.
IEEE Trans Med Imaging ; 41(5): 1104-1113, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34860648

RESUMEN

Simultaneous MR-PET/-SPECT is an emerging technology that capitalises on the invaluable advantages of both modalities, allowing access to numerous sensitive tracers and superior soft-tissue contrast alongside versatile functional imaging capabilities. However, to optimise these capabilities, concurrent acquisitions require the MRI antenna located inside the PET/SPECT field-of-view to be operated without compromising any aspects of system performance or image quality compared to the stand-alone instrumentation. Here, we report a novel gamma-radiation-transparent antenna concept. The end-fed J-shape antenna is particularly adept for hybrid ultra-high field MR-PET/-SPECT applications as it enables all highly attenuating materials to be placed outside the imaging field-of-view. Furthermore, this unique configuration also provides advantages in stand-alone MR applications by reducing the amount of coupling between the cables and the antenna elements, and by lowering the potential specific absorption rate burden. The use of this new design was experimentally verified according to the important features for both ultra-high field MRI and the 511 keV transmission scan. The reconstructed attenuation maps evidently showed much lower attenuation (  âˆ¼ 15 %) for the proposed array when compared to the conventional dipole antenna array since there were no high-density components. In MR, it was observed that the signal-to-noise ratio from the whole volume obtained using the proposed array was comparable to that acquired by the conventional array which was also in agreement with the simulation results. The unique feature, J-shape array, would enable simultaneous MR-PET/-SPECT experiments to be conducted without unduly compromising any aspects of system performance and image quality compared to the stand-alone instrumentation.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Relación Señal-Ruido , Tomografía Computarizada de Emisión de Fotón Único
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 234-237, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36086347

RESUMEN

Traditionally, the diagnosis of schizophrenia was based on the psychiatrist's introspective diagnosis through clinical stratification factors and score-scales, which led to heterogeneity and discrepancy in the symptoms and results. However, there are many studies trying to improve and assist in how its diagnosis could be performed. To objectively classify schizophrenia patients it is required to determine quantitative biomarkers of the disease. In this contribution we propose a method based on feature extraction both in magnetic resonance (MR) and Positron Emission Tomography (PET) imaging. A dataset of 34 participants (17 patients and 17 control subjects) were analyzed and 5 different brain regions were studied (frontal cortex, posterior cingulate cortex, temporal cortex, primary auditory cortex and thalamus). Following a radiomics approach, 43 texture features were extracted using five different statistical methods. These features were used for the training of the five different predictive models (Linear SVM, Gaussian SVM, Bagged Tree, KNN and Naive Bayes). The precision results were obtained classifying schizophrenia both in MR images (89% Area Under the Curve (AUC) in the posterior cingulate cortex) and with PET images (82% AUC in the frontal cortex), being Linear SVM and Naive Bayes the classification models with the highest predictive power. Clinical Relevance- The current study establishes a methodology to classify schizophrenia disease based on quantitative biomarkers using MR and PET images. This tool could assist the psychiatrist as an additional criterion for the diagnosis evaluation.


Asunto(s)
Esquizofrenia , Teorema de Bayes , Biomarcadores , Humanos , Espectroscopía de Resonancia Magnética , Tomografía de Emisión de Positrones/métodos , Esquizofrenia/diagnóstico por imagen
15.
Front Oncol ; 12: 998069, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36452509

RESUMEN

Background: In glioma patients, multimodality therapy and recurrent tumor can lead to structural brain tissue damage characterized by pathologic findings in MR and PET imaging. However, little is known about the impact of different types of damage on the fiber architecture of the affected white matter. Patients and methods: This study included 121 pretreated patients (median age, 52 years; ECOG performance score, 0 in 48%, 1-2 in 51%) with histomolecularly characterized glioma (WHO grade IV glioblastoma, n=81; WHO grade III anaplastic astrocytoma, n=28; WHO grade III anaplastic oligodendroglioma, n=12), who had a resection, radiotherapy, alkylating chemotherapy, or combinations thereof. After a median follow-up time of 14 months (range, 1-214 months), anatomic MR and O-(2-[18F]fluoroethyl)-L-tyrosine (FET) PET images were acquired on a 3T hybrid PET/MR scanner. Post-therapeutic findings comprised resection cavities, regions with contrast enhancement or increased FET uptake and T2/FLAIR hyperintensities. Local fiber density was determined from high angular-resolution diffusion-weighted imaging and advanced tractography methods. A cohort of 121 healthy subjects selected from the 1000BRAINS study matched for age, gender and education served as a control group. Results: Lesion types differed in both affected tissue volumes and relative fiber densities compared to control values (resection cavities: median volume 20.9 mL, fiber density 16% of controls; contrast-enhanced lesions: 7.9 mL, 43%; FET uptake areas: 30.3 mL, 49%; T2/FLAIR hyperintensities: 53.4 mL, 57%, p<0.001). In T2/FLAIR-hyperintense lesions caused by peritumoral edema due to recurrent glioma (n=27), relative fiber density was as low as in lesions associated with radiation-induced gliosis (n=13, 48% vs. 53%, p=0.17). In regions with pathologically increased FET uptake, local fiber density was inversely related (p=0.005) to the extent of uptake. Total fiber loss associated with contrast-enhanced lesions (p=0.006) and T2/FLAIR hyperintense lesions (p=0.013) had a significant impact on overall ECOG score. Conclusions: These results suggest that apart from resection cavities, reduction in local fiber density is greatest in contrast-enhancing recurrent tumors, but total fiber loss induced by edema or gliosis has an equal detrimental effect on the patients' performance status due to the larger volume affected.

16.
Phys Med Biol ; 67(23)2022 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-36356317

RESUMEN

'Objective. Dead time correction (DTC) is an important factor in ensuring accurate quantification in PET measurements. This is currently often achieved using a global DTC method, i.e., an average DTC factor is computed. For PET scanners designed to image dedicated organs, e.g., those used in brain imaging or positron emission mammography (PEM), a substantial amount of the administered radioactivity is located outside of the PET field-of-view (FOV). This activity contributes to the dead time (DT) of the scintillation detectors. Moreover, the count rates of the individual scintillation detectors are potentially very inhomogeneous due to the specific irradiation of each detector, especially for combined MR/PET systems, where radiation shields cannot be applied. Approach: We have developed a block-pairwise DTC method for our Siemens 3T MR BrainPET insert by extending a previously published method that uses the delayed random coincidence count rate to estimate the DT in the individual scans and planes (i.e., scintillation pixel rings). The method was validated in decay experiments using phantoms with a homogenous activity concentration and with and without out-of-FOV activity. Based on a three-compartment phantom, we compared the accuracy and noise properties of the block-pairwise DTC and the global DTC method.Main results. The currently used global DTC led to a substantial positive bias in regions with high activity; the block-pairwise DTC resulted in substantially less bias. The noise level for the block-pairwise DTC was comparable to the global DTC and image reconstructions without any DTC. Finally, we tested the block-pairwise DTC with a data set obtained from volunteer measurements using the mGluR5 (metabotropic glutamate receptor subtype 5) antagonist [11C]ABP688. When the relative differences in activity concentrations obtained with global DTC and block-pairwise DTC for the ACC and the cerebellum GM were compared, the ratios differed by a factor of up to 1.4 at the beginning-when the first injection is administered as a bolus with high radioactivity.Significance. In this work, global DTC was shown to have the potential to introduce quantification bias, while better quantitation accuracy was achieved with the presented block-pairwise DTC method. The method can be implemented in all systems that use the delayed window technique and is particulary expected to improve the quantiation accuracy of dedicated brain PET scanners due to their geometry.'


Asunto(s)
Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Humanos , Tomografía de Emisión de Positrones/métodos , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador , Encéfalo/diagnóstico por imagen
17.
Transl Psychiatry ; 12(1): 6, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-35013095

RESUMEN

Currently, the metabotropic glutamate receptor 5 (mGluR5) is the subject of several lines of research in the context of neurology and is of high interest as a target for positron-emission tomography (PET). Here, we assessed the feasibility of using [11C]ABP688, a specific antagonist radiotracer for an allosteric site on the mGluR5, to evaluate changes in glutamatergic neurotransmission through a mismatch-negativity (MMN) task as a part of a simultaneous and synchronized multimodal PET/MR-EEG study. We analyzed the effect of MMN by comparing the changes in nondisplaceable binding potential (BPND) prior to (baseline) and during the task in 17 healthy subjects by applying a bolus/infusion protocol. Anatomical and functional regions were analyzed. A small change in BPND was observed in anatomical regions (posterior cingulate cortex and thalamus) and in a functional network (precuneus) after the start of the task. The effect size was quantified using Kendall's W value and was 0.3. The motor cortex was used as a control region for the task and did not show any significant BPND changes. There was a significant ΔBPND between acquisition conditions. On average, the reductions in binding across the regions were - 8.6 ± 3.2% in anatomical and - 6.4 ± 0.5% in the functional network (p ≤ 0.001). Correlations between ΔBPND and EEG latency for both anatomical (p = 0.008) and functional (p = 0.022) regions were found. Exploratory analyses suggest that the MMN task played a role in the glutamatergic neurotransmission, and mGluR5 may be indirectly modulated by these changes.


Asunto(s)
Tomografía de Emisión de Positrones , Receptor del Glutamato Metabotropico 5 , Radioisótopos de Carbono , Electroencefalografía , Humanos , Oximas , Piridinas
18.
Cancers (Basel) ; 14(14)2022 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-35884396

RESUMEN

O-(2-[18F]fluoroethyl)-L-tyrosine (FET) is a widely used amino acid tracer for positron emission tomography (PET) imaging of brain tumours. This retrospective study and survey aimed to analyse our extensive database regarding the development of FET PET investigations, indications, and the referring physicians' rating concerning the role of FET PET in the clinical decision-making process. Between 2006 and 2019, we performed 6534 FET PET scans on 3928 different patients against a backdrop of growing demand for FET PET. In 2019, indications for the use of FET PET were as follows: suspected recurrent glioma (46%), unclear brain lesions (20%), treatment monitoring (19%), and suspected recurrent brain metastasis (13%). The referring physicians were neurosurgeons (60%), neurologists (19%), radiation oncologists (11%), general oncologists (3%), and other physicians (7%). Most patients travelled 50 to 75 km, but 9% travelled more than 200 km. The role of FET PET in decision-making in clinical practice was evaluated by a questionnaire consisting of 30 questions, which was filled out by 23 referring physicians with long experience in FET PET. Fifty to seventy per cent rated FET PET as being important for different aspects of the assessment of newly diagnosed gliomas, including differential diagnosis, delineation of tumour extent for biopsy guidance, and treatment planning such as surgery or radiotherapy, 95% for the diagnosis of recurrent glioma, and 68% for the diagnosis of recurrent brain metastases. Approximately 50% of the referring physicians rated FET PET as necessary for treatment monitoring in patients with glioma or brain metastases. All referring physicians stated that the availability of FET PET is essential and that it should be approved for routine use. Although the present analysis is limited by the fact that only physicians who frequently referred patients for FET PET participated in the survey, the results confirm the high relevance of FET PET in the clinical diagnosis of brain tumours and support the need for its approval for routine use.

19.
PLoS One ; 16(1): e0245580, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33481896

RESUMEN

Iterative image reconstruction is widely used in positron emission tomography. However, it is known to contribute to quantitation bias and is particularly pronounced during dynamic studies with 11C-labeled radiotracers where count rates become low towards the end of the acquisition. As the strength of the quantitation bias depends on the counts in the reconstructed frame, it can differ from frame to frame of the acquisition. This is especially relevant in the case of neuro-receptor studies with simultaneous PET/MR when a bolus-infusion protocol is applied to allow the comparison of pre- and post-task effects. Here, count dependent changes in quantitation bias may interfere with task changes. We evaluated the impact of different framing schemes on quantitation bias and its propagation into binding potential (BP) using a phantom decay study with 11C and 3D OP-OSEM. Further, we propose a framing scheme that keeps the true counts per frame constant over the acquisition time as constant framing schemes and conventional increasing framing schemes are unlikely to achieve stable bias values during the acquisition time range. For a constant framing scheme with 5 minutes frames, the BP bias was 7.13±2.01% (10.8% to 3.8%) compared to 5.63±2.85% (7.8% to 4.0%) for conventional increasing framing schemes. Using the proposed constant true counts framing scheme, a stabilization of the BP bias was achieved at 2.56±3.92% (3.5% to 1.7%). The change in BP bias was further studied by evaluating the linear slope during the acquisition time interval. The lowest slope values were observed in the constant true counts framing scheme. The constant true counts framing scheme was effective for BP bias stabilization at relevant activity and time ranges. The mean BP bias under these conditions was 2.56±3.92%, which represents the lower limit for the detection of changes in BP during equilibrium and is especially important in the case of cognitive tasks where the expected changes are low.


Asunto(s)
Radioisótopos de Carbono , Imagenología Tridimensional/métodos , Tomografía de Emisión de Positrones , Marcaje Isotópico , Fantasmas de Imagen
20.
IEEE Trans Med Imaging ; 40(7): 1852-1862, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33735076

RESUMEN

The kinetic analysis of [Formula: see text]-FET time-activity curves (TAC) can provide valuable diagnostic information in glioma patients. The analysis is most often limited to the average TAC over a large tissue volume and is normally assessed by visual inspection or by evaluating the time-to-peak and linear slope during the late uptake phase. Here, we derived and validated a linearized model for TACs of [Formula: see text]-FET in dynamic PET scans. Emphasis was put on the robustness of the numerical parameters and how reliably automatic voxel-wise analysis of TAC kinetics was possible. The diagnostic performance of the extracted shape parameters for the discrimination between isocitrate dehydrogenase (IDH) wildtype (wt) and IDH-mutant (mut) glioma was assessed by receiver-operating characteristic in a group of 33 adult glioma patients. A high agreement between the adjusted model and measured TACs could be obtained and relative, estimated parameter uncertainties were small. The best differentiation between IDH-wt and IDH-mut gliomas was achieved with the linearized model fitted to the averaged TAC values from dynamic FET PET data in the time interval 4-50 min p.i.. When limiting the acquisition time to 20-40 min p.i., classification accuracy was only slightly lower (-3%) and was comparable to classification based on linear fits in this time interval. Voxel-wise fitting was possible within a computation time ≈ 1 min per image slice. Parameter uncertainties smaller than 80% for all fits with the linearized model were achieved. The agreement of best-fit parameters when comparing voxel-wise fits and fits of averaged TACs was very high (p < 0.001).


Asunto(s)
Neoplasias Encefálicas , Glioma , Adulto , Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Humanos , Cinética , Tomografía de Emisión de Positrones , Tirosina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA