Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Curr Heart Fail Rep ; 9(1): 65-74, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22135186

RESUMEN

The medical community has seen an explosive rise in the utilization of implantable mechanical circulatory support devices for late-stage cardiomyopathy. Care for these complex patients requires a basic understanding of device physiology and potential complications. This review focuses on an algorithm that incorporates a careful clinical history and examination with diagnostic modalities for the evaluation of a patient who is failing therapy with a continuous-flow left ventricular assist device, as well as the general management and optimization of patients implanted with an artificial heart.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Artificial , Corazón Auxiliar , Algoritmos , Ventrículos Cardíacos , Humanos
3.
ASAIO J ; 61(2): 213-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25419833

RESUMEN

Dobutamine is a rare and unrecognized cause of eosinophilic myocarditis (EM). It is even more unique for it to cause significant clinical deterioration. Patients with end stage cardiomyopathy have very little cardiac reserve and dobutamine induced myocarditis may cause enough harm to require urgent mechanical circulatory support. We describe a man with dilated cardiomyopathy that developed accelerated clinical deterioration from dobutamine induced EM. He had a predominance of right heart failure, requiring an urgent biventricular assist device and acutely responded to withdrawal of dobutamine.


Asunto(s)
Dobutamina/efectos adversos , Eosinofilia/inducido químicamente , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Miocarditis/inducido químicamente , Agonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Agonistas de Receptores Adrenérgicos beta 1/efectos adversos , Anciano , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/tratamiento farmacológico , Dobutamina/administración & dosificación , Eosinofilia/sangre , Humanos , Masculino , Miocarditis/patología
4.
Ann Thorac Surg ; 96(6): 2245-7, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24296201

RESUMEN

We report here a hemophilia patient who was bridged with a left ventricle assist device and later received heart transplantation. Preparation for surgery with factor VIII supplementation, intraoperative conduct of surgery, and challenges of postoperative course are described with a brief literature review.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/métodos , Corazón Auxiliar , Hemofilia A/complicaciones , Administración Oral , Coagulantes/administración & dosificación , Factor VIII/administración & dosificación , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Hemofilia A/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Proteínas Recombinantes , Función Ventricular Izquierda
5.
J Heart Lung Transplant ; 31(1): 67-72, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22071240

RESUMEN

BACKGROUND: Jugular venous pressure (JVP) is assessed to estimate volume status in patients with heart failure because right atrial pressure (RAP) reflects pulmonary capillary wedge pressure (PCWP). In a large cohort of heart failure patients spanning 14 years, we sought to further characterize the relationship between RAP and PCWP, including identifying temporal trends, to optimize estimates of PCWP by JVP. We also sought to determine whether the RAP to PCWP relationship impacts post-transplant mortality. METHODS: Hemodynamic data were obtained from 4,079 patients before cardiac transplantation. Elevated RAP was defined as ≥10 mm Hg and elevated PCWP ≥22 mm Hg. Hemodynamics were "concordant" when both RAP and PCWP were elevated or when both were not elevated. The frequency of concordant hemodynamics was assessed over 3 eras (1993 to 1997, 1998 to 2002, 2003 to 2007). Baseline characteristics were compared among quartiles of the ratio (RAP+1)/PCWP. The association of (RAP+1)/PCWP with 2-year mortality after cardiac transplantation was assessed using multivariate models. RESULTS: The frequency of concordant hemodynamics over time was stable (74%, 72%, 73%; p = 0.4). Increasing (RAP+1)/PCWP was associated with the following variables: female gender; cardiomyopathy etiology besides ischemic or non-ischemic; prior sternotomies; and lower creatinine clearance (p < 0.01 for all). Elevated (RAP+1)/PCWP was associated with post-transplant mortality (relative risk 1.2, 95% confidence interval 1.02 to 1.37, p = 0.02). CONCLUSIONS: [corrected] RAP and PCWP remain concordant in most heart failure patients, supporting the ongoing use of JVP to estimate PCWP. Easily identifiable patient characteristics were associated with an increased RAP/PCWP ratio, and their presence should alert clinicians that PCWP may be overestimated by JVP assessment. A higher RAP/PCWP ratio was an adverse risk factor for post-cardiac transplant survival.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Presión Esfenoidal Pulmonar/fisiología , Presión Ventricular/fisiología , Cateterismo Cardíaco , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA