Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Feline Med Surg ; 25(5): 1098612X231171434, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37226706

RESUMEN

OBJECTIVES: The aim of the study was to compare the diagnostic performances of a smartphone-based colorimetric method (SBCM) for urinalysis with a semi-automated point-of-care (POC) analyser using standardised solutions and cat urine. METHODS: Artificial solutions (negative and positive quality controls, and purposely designed artificial urine) and natural urine from 216 cats were used. Two urine reagent strips were simultaneously dipped in each sample. One dipstick was read by the SBCM and the other by the POC analyser at the same time. Results for pH, proteins, bilirubin, 'blood', glucose and ketones were considered. Overall agreement and sensitivity, specificity and accuracy of the SBCM were determined based on selected cut-offs. RESULTS: For the artificial solutions, 80 comparisons were obtained for each analyte and each expected concentration. The overall agreement (exactly the same result) between the two methods was 78.4%. SBCM sensitivity, specificity and accuracy were 99.0%, 100% and 99.3%, respectively. The correlation between the two methods was almost perfect (Cohen's kappa coefficient = 0.9851). For natural urine samples, the overall agreement (including pH) was 68.6%. Using optimal cut-offs for the SBCM determined from the results of analysis of artificial solutions, the sensitivity, specificity and accuracy of the SBCM were 100%, 76.02% and 80.5%, respectively. In this situation, the correlation between the two methods was moderate (Cohen's kappa coefficient = 0.5401). This was mostly due to a high rate of false-positive results for bilirubin (61.1%). CONCLUSIONS AND RELEVANCE: With proper cut-off use (ie, considering positive or negative results) the SBCM evaluated here has a perfect sensitivity and appropriate diagnostic performances for proteins, 'blood', glucose and ketones. Based on these experimental data, this method appears suitable for dipstick urinalysis but positive results for bilirubin and proteins have to be confirmed.


Asunto(s)
Colorimetría , Teléfono Inteligente , Gatos , Animales , Colorimetría/veterinaria , Urinálisis/veterinaria , Glucosa , Bilirrubina , Cetonas
2.
Pathogens ; 12(1)2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36678462

RESUMEN

Dogs and cats may suffer from a variety of diseases, mainly immune mediated, that require the administration of immunosuppressive drugs. Such therapies can cause adverse effects either by the toxicity of the drugs or as a consequence of immune suppression and associated opportunistic infections. Here we present an, yet unknown, association of Toxoplasma gondii and Alternaria fungus, within cutaneous lesions in a dog under long-term immunosuppressive therapy. The diagnosis of such infections is laborious and not obvious at first glance, since the clinical signs of cutaneous toxoplasmosis, neosporosis or alternariosis are not specific. A further laboratory confirmation is needed. Therefore, we currently recommend that dogs and cats should undergo serologic testing for toxoplasmosis or neosporosis prior to immunosuppressive therapy and a regular dermatological evaluation during the immunosuppressive therapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA