Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Liver Transpl ; 30(2): 182-191, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-37432891

RESUMEN

Computed tomography coronary angiography (CTCA) is increasingly utilized for preoperative risk stratification before liver transplantation (LT). We sought to assess the predictors of advanced atherosclerosis on CTCA using the recently developed Coronary Artery Disease-Reporting and Data System (CAD-RADS) score and its impact on the prediction of long-term major adverse cardiovascular events (MACE) following LT. We conducted a retrospective cohort study of consecutive patients who underwent CTCA for LT work-up between 2011 and 2018. Advanced atherosclerosis was defined as coronary artery calcium scores > 400 or CAD-RADS score ≥ 3 (≥50% coronary artery stenosis). MACE was defined as myocardial infarction, heart failure, stroke, or resuscitated cardiac arrest. Overall, 229 patients underwent CTCA (mean age 66 ± 5 y, 82% male). Of these, 157 (68.5%) proceeded with LT. The leading etiology of cirrhosis was hepatitis (47%), and 53% of patients had diabetes before transplant. On adjusted analysis, male sex (OR 4.6, 95% CI 1.5-13.8, p = 0.006), diabetes (OR 2.2, 95% CI 1.2-4.2, p = 0.01) and dyslipidemia (OR 3.1, 95% CI 1.3-6.9, p = 0.005) were predictors of advanced atherosclerosis on CTCA. Thirty-two patients (20%) experienced MACE. At a median follow-up of 4 years, CAD-RADS ≥ 3, but not coronary artery calcium scores, was associated with a heightened risk of MACE (HR 5.8, 95% CI 1.6-20.6, p = 0.006). Based on CTCA results, 71 patients (31%) commenced statin therapy which was associated with a lower risk of all-cause mortality (HR 0.48, 95% CI 0.24-0.97, p = 0.04). The standardized CAD-RADS classification on CTCA predicted the occurrence of cardiovascular outcomes following LT, with a potential to increase the utilization of preventive cardiovascular therapies.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Trasplante de Hígado , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Angiografía Coronaria/métodos , Estudios Retrospectivos , Trasplante de Hígado/efectos adversos , Calcio , Factores de Riesgo , Medición de Riesgo/métodos , Pronóstico , Valor Predictivo de las Pruebas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/etiología , Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X/métodos , Aterosclerosis/complicaciones
2.
Eur Radiol ; 2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38337070

RESUMEN

OBJECTIVES: To develop and share a deep learning method that can accurately identify optimal inversion time (TI) from multi-vendor, multi-institutional and multi-field strength inversion scout (TI scout) sequences for late gadolinium enhancement cardiac MRI. MATERIALS AND METHODS: Retrospective multicentre study conducted on 1136 1.5-T and 3-T cardiac MRI examinations from four centres and three scanner vendors. Deep learning models, comprising a convolutional neural network (CNN) that provides input to a long short-term memory (LSTM) network, were trained on TI scout pixel data from centres 1 to 3 to identify optimal TI, using ground truth annotations by two readers. Accuracy within 50 ms, mean absolute error (MAE), Lin's concordance coefficient (LCCC) and reduced major axis regression (RMAR) were used to select the best model from validation results, and applied to holdout test data. Robustness of the best-performing model was also tested on imaging data from centre 4. RESULTS: The best model (SE-ResNet18-LSTM) produced accuracy of 96.1%, MAE 22.9 ms and LCCC 0.47 compared to ground truth on the holdout test set and accuracy of 97.3%, MAE 15.2 ms and LCCC 0.64 when tested on unseen external (centre 4) data. Differences in vendor performance were observed, with greatest accuracy for the most commonly represented vendor in the training data. CONCLUSION: A deep learning model was developed that can identify optimal inversion time from TI scout images on multi-vendor data with high accuracy, including on previously unseen external data. We make this model available to the scientific community for further assessment or development. CLINICAL RELEVANCE STATEMENT: A robust automated inversion time selection tool for late gadolinium-enhanced imaging allows for reproducible and efficient cross-vendor inversion time selection. KEY POINTS: • A model comprising convolutional and recurrent neural networks was developed to extract optimal TI from TI scout images. • Model accuracy within 50 ms of ground truth on multi-vendor holdout and external data of 96.1% and 97.3% respectively was achieved. • This model could improve workflow efficiency and standardise optimal TI selection for consistent LGE imaging.

3.
AJR Am J Roentgenol ; 222(3): e2329418, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37315018

RESUMEN

MRI plays an important role in the evaluation of kidney allografts for vascular complications as well as parenchymal insults. Transplant renal artery stenosis, the most common vascular complication of kidney transplant, can be evaluated by MRA using gadolinium and nongadolinium contrast agents as well as by unenhanced MRA techniques. Parenchymal injury occurs through a variety of pathways, including graft rejection, acute tubular injury, BK polyomavirus infection, drug-induced interstitial nephritis, and pyelonephritis. Investigational MRI techniques have sought to differentiate among these causes of dysfunction as well as to assess the degree of interstitial fibrosis or tubular atrophy (IFTA)-the common end pathway for all of these processes-which is currently evaluated by invasively obtained core biopsies. Some of these MRI sequences have shown promise in not only assessing the cause of parenchymal injury but also assessing IFTA noninvasively. This review describes current clinically used MRI techniques and previews promising investigational MRI techniques for assessing complications of kidney grafts.


Asunto(s)
Enfermedades Renales , Riñón , Humanos , Constricción Patológica , Riñón/patología , Fibrosis , Enfermedades Renales/etiología , Rechazo de Injerto/diagnóstico por imagen , Aloinjertos/patología , Imagen por Resonancia Magnética/efectos adversos
4.
Skeletal Radiol ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755335

RESUMEN

OBJECTIVE: Osteoporosis and falls are both prevalent in the elderly, and CT brain (CTB) is frequently performed post head-strike. We aim to validate the relationship between frontal bone density (Hounsfield unit) from routine CTB and bone mineral density from dual-energy X-ray absorptiometry (DEXA) scan for opportunistic osteoporosis screening. MATERIALS AND METHODS: Patients who had a non-contrast CTB followed by a DEXA scan in the subsequent year were included in this multi-center retrospective study. The relationship between frontal bone density on CT and femoral neck T-score on DEXA was examined using ANOVA, Pearson's correlation, and receiver operating curve (ROC) analysis. Sensitivity, specificity, negative and positive predictive values, and area under the curve (AUC) were calculated. RESULTS: Three hundred twenty-six patients (205 females and 121 males) were analyzed. ANOVA analysis showed that frontal bone density was lower in patients with DEXA-defined osteoporosis (p < 0.001), while Pearson's correlation analysis demonstrated a fair correlation with femoral neck T-score (r = 0.3, p < 0.001). On subgroup analysis, these were true in females but not in males. On ROC analysis, frontal bone density weakly predicted osteoporosis (AUC 0.6, 95% CI 0.5-0.7) with no optimal threshold identified. HU < 610 was highly specific (87.5%) but poorly sensitive (18.9%). HU > 1200 in females had a strong negative predictive value for osteoporosis (92.6%, 95% CI 87.1-98.1%). CONCLUSION: Frontal bone density from routine CTB is significantly different between females with and without osteoporosis, but not between males. However, frontal bone density was a weak predictor for DEXA-defined osteoporosis. Further research is required to determine the role of CTB in opportunistic osteoporosis screening.

5.
Eur Heart J ; 44(35): 3311-3322, 2023 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-37350487

RESUMEN

Technological advancement and the COVID-19 pandemic have brought virtual learning and working into our daily lives. Extended realities (XR), an umbrella term for all the immersive technologies that merge virtual and physical experiences, will undoubtedly be an indispensable part of future clinical practice. The intuitive and three-dimensional nature of XR has great potential to benefit healthcare providers and empower patients and physicians. In the past decade, the implementation of XR into cardiovascular medicine has flourished such that it is now integrated into medical training, patient education, pre-procedural planning, intra-procedural visualization, and post-procedural care. This review article discussed how XR could provide innovative care and complement traditional practice, as well as addressing its limitations and considering its future perspectives.


Asunto(s)
COVID-19 , Realidad Virtual , Humanos , COVID-19/epidemiología , Pandemias/prevención & control
6.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33140551

RESUMEN

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Riñón , Imagen por Resonancia Magnética , Consenso , Técnica Delphi , Humanos , Estudios Multicéntricos como Asunto , Circulación Renal
7.
Eur Radiol ; 32(9): 5907-5920, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35368227

RESUMEN

OBJECTIVES: To develop an image-based automatic deep learning method to classify cardiac MR images by sequence type and imaging plane for improved clinical post-processing efficiency. METHODS: Multivendor cardiac MRI studies were retrospectively collected from 4 centres and 3 vendors. A two-head convolutional neural network ('CardiSort') was trained to classify 35 sequences by imaging sequence (n = 17) and plane (n = 10). Single vendor training (SVT) on single-centre images (n = 234 patients) and multivendor training (MVT) with multicentre images (n = 434 patients, 3 centres) were performed. Model accuracy and F1 scores on a hold-out test set were calculated, with ground truth labels by an expert radiologist. External validation of MVT (MVTexternal) was performed on data from 3 previously unseen magnet systems from 2 vendors (n = 80 patients). RESULTS: Model sequence/plane/overall accuracy and F1-scores were 85.2%/93.2%/81.8% and 0.82 for SVT and 96.1%/97.9%/94.3% and 0.94 MVT on the hold-out test set. MVTexternal yielded sequence/plane/combined accuracy and F1-scores of 92.7%/93.0%/86.6% and 0.86. There was high accuracy for common sequences and conventional cardiac planes. Poor accuracy was observed for underrepresented classes and sequences where there was greater variability in acquisition parameters across centres, such as perfusion imaging. CONCLUSIONS: A deep learning network was developed on multivendor data to classify MRI studies into component sequences and planes, with external validation. With refinement, it has potential to improve workflow by enabling automated sequence selection, an important first step in completely automated post-processing pipelines. KEY POINTS: • Deep learning can be applied for consistent and efficient classification of cardiac MR image types. • A multicentre, multivendor study using a deep learning algorithm (CardiSort) showed high classification accuracy on a hold-out test set with good generalisation to images from previously unseen magnet systems. • CardiSort has potential to improve clinical workflows, as a vital first step in developing fully automated post-processing pipelines.


Asunto(s)
Imagen por Resonancia Magnética , Redes Neurales de la Computación , Corazón/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
8.
Radiographics ; 41(5): E157-E158, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34469213

RESUMEN

Unlike CT angiography, which requires the use of contrast medium, MR angiography (MRA) can be performed without the use of contrast agents. This subfield of MRA is referred to as non-contrast-enhanced MRA (NC-MRA). While NC-MRA can be performed in many patients, it is especially useful in the imaging of pediatric and pregnant patients, as well as in patients with renal impairment. NC-MRA can also provide unique functional and hemodynamic information that is not obtainable with CT angiography or contrast-enhanced MRA. This module gives an overview of the predominant NC-MRA techniques that are currently available on modern clinical MRI systems, while also discussing some new and emerging topics in the field. This module is the second in a series created on behalf of the Society for Magnetic Resonance Angiography (SMRA), a group of researchers and clinicians who are passionate about the benefits of MRA but understand its challenges. The full digital presentation is available online. ©RSNA, 2021.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética , Niño , Angiografía por Tomografía Computarizada , Humanos , Angiografía por Resonancia Magnética
9.
J Comput Assist Tomogr ; 45(1): 37-51, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32976265

RESUMEN

ABSTRACT: Gadolinium-based contrast agents for clinical magnetic resonance imaging are overall safe. However, the discovery of nephrogenic systemic fibrosis in patients with severe renal impairment and gadolinium deposition in patients receiving contrast have generated developments in contrast-free imaging of the vasculature, that is, noncontrast magnetic resonance angiography. This article presents an update on noncontrast magnetic resonance angiography techniques, with comparison to other imaging alternatives. Potential benefits and challenges to implementation, and evidence to date for various clinical applications are discussed.


Asunto(s)
Medios de Contraste/efectos adversos , Gadolinio/efectos adversos , Dermopatía Fibrosante Nefrogénica/diagnóstico por imagen , Humanos , Angiografía por Resonancia Magnética , Dermopatía Fibrosante Nefrogénica/complicaciones
10.
J Comput Assist Tomogr ; 45(6): 849-855, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34581705

RESUMEN

BACKGROUND AND AIMS: Abdominal aortic calcification (AAC) is correlated with cardiovascular outcomes independent of traditional risk factors. Quantification of AAC on computed tomography (CT) has not been standardized. Reconstruction parameters have been shown to impact coronary calcium scores. The aim of our study was to assess the impact of abdominal CT reconstruction parameters, slice thickness (ST), and display field of view (DFOV) on AAC quantitative scoring on abdominal CT examinations. METHODS: We retrospectively measured AAC on noncontrast CT of 46 patients (mean age, 64.1 years; 35 males) using 5 different reconstruction protocols with a range of ST and DFOV: protocol A, 2.5 mm ST, 35 cm DFOV; protocol B, 2.5 mm ST, 50 cm DFOV; protocol C, 2.5 mm ST, 25 cm DFOV; protocol D, 5 mm ST, 35 cm DFOV; and protocol E: 0.625 mm ST, 35 cm DFOV. The AAC scores from each protocol were compared using concordance correlation coefficient and Bland-Altman agreement analyses. RESULTS: The AAC mean (SD) scores for each protocol were as follows: A, 2022 (2418); B, 2022 (2412); C, 1939 (2310); D, 2220 (2695); and E, 1862 (2234). The AAC mean score differences between protocols and reference protocol A were -0.47, 82.01, -198.94, and 160 for protocols B, C, D, and E, respectively, with differences between protocols C to E statistically significantly different (P < 0.05). The different protocols showed overall excellent correlation (concordance correlation coefficient, >0.9) between AAC scores. CONCLUSIONS: Slice thickness and DFOV can impact AAC score measurement. A description of reconstruction parameters is important to allow comparisons across different cohorts.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/diagnóstico por imagen , Aorta Abdominal/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
11.
J Comput Assist Tomogr ; 45(2): 218-223, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33661149

RESUMEN

ABSTRACT: Renal echo planar diffusion tensor imaging (DTI) has clinical potential but suffers from geometric distortion. We evaluated feasibility of reversed gradient distortion correction in 10 diabetic patients and 6 volunteers. Renal area, apparent diffusion coefficient, fractional anisotropy, and tensor eigenvalues were measured on uncorrected and distortion-corrected DTI. Corrected DTI correlated better than uncorrected DTI (r = 0.904 vs 0.840, P = 0.002) with reference anatomic T2-weighted imaging, with no significant difference in DTI metrics.


Asunto(s)
Imagen de Difusión Tensora/métodos , Interpretación de Imagen Asistida por Computador/métodos , Riñón/diagnóstico por imagen , Adulto , Nefropatías Diabéticas/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Persona de Mediana Edad , Adulto Joven
13.
MAGMA ; 33(1): 177-195, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31676990

RESUMEN

OBJECTIVES: Standardization is an important milestone in the validation of DWI-based parameters as imaging biomarkers for renal disease. Here, we propose technical recommendations on three variants of renal DWI, monoexponential DWI, IVIM and DTI, as well as associated MRI biomarkers (ADC, D, D*, f, FA and MD) to aid ongoing international efforts on methodological harmonization. MATERIALS AND METHODS: Reported DWI biomarkers from 194 prior renal DWI studies were extracted and Pearson correlations between diffusion biomarkers and protocol parameters were computed. Based on the literature review, surveys were designed for the consensus building. Survey data were collected via Delphi consensus process on renal DWI preparation, acquisition, analysis, and reporting. Consensus was defined as ≥ 75% agreement. RESULTS: Correlations were observed between reported diffusion biomarkers and protocol parameters. Out of 87 survey questions, 57 achieved consensus resolution, while many of the remaining questions were resolved by preference (65-74% agreement). Summary of the literature and survey data as well as recommendations for the preparation, acquisition, processing and reporting of renal DWI were provided. DISCUSSION: The consensus-based technical recommendations for renal DWI aim to facilitate inter-site harmonization and increase clinical impact of the technique on a larger scale by setting a framework for acquisition protocols for future renal DWI studies. We anticipate an iterative process with continuous updating of the recommendations according to progress in the field.


Asunto(s)
Biomarcadores/metabolismo , Imagen de Difusión por Resonancia Magnética , Riñón/diagnóstico por imagen , Investigación Biomédica Traslacional , Algoritmos , Consenso , Técnica Delphi , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Riñón/metabolismo , Modelos Estadísticos , Movimiento (Física) , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
14.
J Comput Assist Tomogr ; 43(2): 323-332, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30664117

RESUMEN

OBJECTIVE: The aim of this study was to evaluate agreement of measured thoracic aortic caliber in patients with aortic disease, using electrocardiographically-(ECG) and pulse-gated breath-hold noncontrast balanced steady-state free precession MRA (ECG-MRA, P-MRA) at 1.5 T, compared with ECG-gated computed tomographic angiography (CTA). METHODS: Thirty-one patients underwent ECG-MRA, P-MRA, and CTA. Two readers independently measured aortic caliber in 7 segments, with agreement between techniques and readers evaluated. Image quality was qualitatively assessed. RESULTS: There was overall excellent agreement among ECG-MRA, P-MRA, and CTA for measured aortic caliber (Lin's concordance correlation coefficient ≥0.94, all comparisons); however, lower concordance was noted at the annulus (Lin's concordance correlation coefficient <0.6) at segmental assessment. There was excellent interreader agreement for aortic caliber for all 3 techniques (intraclass correlation coefficient >0.94). Image quality was poorer for both MRA techniques compared with CTA, particularly at the aortic root. CONCLUSIONS: Electrocardiographically-gated MRA and P-MRA at 1.5 T achieve comparable thoracic aortic measurements to gated CTA in clinical patients, despite inferior image quality.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Electrocardiografía/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Enfermedades de la Aorta/fisiopatología , Contencion de la Respiración , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
15.
Magn Reson Med ; 79(2): 826-838, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28497486

RESUMEN

PURPOSE: A 5D whole-heart sparse imaging framework is proposed for simultaneous assessment of myocardial function and high-resolution cardiac and respiratory motion-resolved whole-heart anatomy in a single continuous noncontrast MR scan. METHODS: A non-electrocardiograph (ECG)-triggered 3D golden-angle radial balanced steady-state free precession sequence was used for data acquisition. The acquired 3D k-space data were sorted into a 5D dataset containing separated cardiac and respiratory dimensions using a self-extracted respiratory motion signal and a recorded ECG signal. Images were then reconstructed using XD-GRASP, a multidimensional compressed sensing technique exploiting correlations/sparsity along cardiac and respiratory dimensions. 5D whole-heart imaging was compared with respiratory motion-corrected 3D and 4D whole-heart imaging in nine volunteers for evaluation of the myocardium, great vessels, and coronary arteries. It was also compared with breath-held, ECG-gated 2D cardiac cine imaging for validation of cardiac function quantification. RESULTS: 5D whole-heart images received systematic higher quality scores in the myocardium, great vessels and coronary arteries. Quantitative coronary sharpness and length were always better for the 5D images. Good agreement was obtained for quantification of cardiac function compared with 2D cine imaging. CONCLUSION: 5D whole-heart sparse imaging represents a robust and promising framework for simplified comprehensive cardiac MRI without the need for breath-hold and motion correction. Magn Reson Med 79:826-838, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Corazón/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Algoritmos , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Adulto Joven
16.
Magn Reson Med ; 77(4): 1473-1484, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27052418

RESUMEN

PURPOSE: Free-breathing whole-heart coronary MR angiography (MRA) commonly uses navigators to gate respiratory motion, resulting in lengthy and unpredictable acquisition times. Conversely, self-navigation has 100% scan efficiency, but requires motion correction over a broad range of respiratory displacements, which may introduce image artifacts. We propose replacing navigators and self-navigation with a respiratory motion-resolved reconstruction approach. METHODS: Using a respiratory signal extracted directly from the imaging data, individual signal-readouts are binned according to their respiratory states. The resultant series of undersampled images are reconstructed using an extradimensional golden-angle radial sparse parallel imaging (XD-GRASP) algorithm, which exploits sparsity along the respiratory dimension. Whole-heart coronary MRA was performed in 11 volunteers and four patients with the proposed methodology. Image quality was compared with that obtained with one-dimensional respiratory self-navigation. RESULTS: Respiratory-resolved reconstruction effectively suppressed respiratory motion artifacts. The quality score for XD-GRASP reconstructions was greater than or equal to self-navigation in 80/88 coronary segments, reaching diagnostic quality in 61/88 segments versus 41/88. Coronary sharpness and length were always superior for the respiratory-resolved datasets, reaching statistical significance (P < 0.05) in most cases. CONCLUSION: XD-GRASP represents an attractive alternative for handling respiratory motion in free-breathing whole heart MRI and provides an effective alternative to self-navigation. Magn Reson Med 77:1473-1484, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Artefactos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Anciano , Algoritmos , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/patología , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Mecánica Respiratoria , Sensibilidad y Especificidad
17.
J Comput Assist Tomogr ; 41(2): 327-333, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27753721

RESUMEN

OBJECTIVE: The aim of this study was to evaluate image quality and accuracy of 64+ detector multidetector computed tomography angiography (MDCTA) for hemodynamically significant (≥50%) stenosis in patients with symptomatic peripheral arterial disease (PAD) using digital subtraction angiography as the reference standard. METHODS: This is a retrospective study of 29 patients with PAD (19 men, 10 women) who underwent lower limb MDCTA (64- or 80-detector) and digital subtraction angiography. Image quality and accuracy of MDCTA for hemodynamically significant stenosis were assessed in the infrarenal aorta and 15 lower extremity segments. RESULTS: Four hundred fifty-three segments were adequately visualized at both modalities. Multidetector CTA had 84.8% sensitivity, 87.7% specificity, and 86.3% accuracy for significant stenosis. Accuracy was decreased in the calf when compromising arterial wall calcifications were present versus absent (55.9% vs 82.4%, P < 0.0001). CONCLUSIONS: 64+ MDCTA is accurate in patients with symptomatic PAD. However, diagnostic accuracy in below-knee vessels remains relatively poorer. Alternative imaging modalities should be considered where below-knee disease is suspected.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada Multidetector/métodos , Enfermedad Arterial Periférica/diagnóstico por imagen , Atención Terciaria de Salud , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital/métodos , Femenino , Humanos , Extremidad Inferior/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
18.
J Comput Assist Tomogr ; 41(6): 854-860, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28708731

RESUMEN

OBJECTIVE: The purpose of this study is to evaluate feasibility, image quality (IQ), and accuracy of noncontrast hybrid arterial spin labeling (NoHASL) magnetic resonance angiography (MRA) compared with time of flight (TOF) MRA and contrast-enhanced (CE) MRA in patients with known/suspected cerebrovascular ischemia. METHODS: Thirty inpatients were imaged at 1.5 T. Two neuroradiologists assessed 630 intracranial arterial segments for IQ (1, nondiagnostic; 3, satisfactory for diagnosis; and 5, excellent). Hemodynamically significant stenosis (>50%) was assessed against all combined techniques as reference. RESULTS: The NoHASL MRA IQ was diagnostic (3.32 ± 0.86) but affected by signal to noise ratio and spatial resolution limitations and significantly inferior to TOF (3.48 ± 0.68) and CE MRA (3.44 ± 0.78) (P < 0.0001 in both comparisons). Fourteen (2.2%) of 630 segments had hemodynamically significant stenoses at the reference standard. Sensitivity/specificity was not significantly different between techniques: NoHASL MRA, 67.9%/90.0%; TOF MRA, 67.9%/97.7%; and CE MRA, 50.0%/98.7%. CONCLUSIONS: The NoHASL MRA is feasible, with diagnostic quality imaging of proximal intracranial vessels. Low disease prevalence limited the assessment of technique accuracy.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Neuroimagen/métodos , Marcadores de Spin , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
19.
MAGMA ; 29(2): 197-206, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26516082

RESUMEN

OBJECTIVE: To investigate the precision and accuracy of a new semi-automated method for kidney segmentation from single-breath-hold non-contrast MRI. MATERIALS AND METHODS: The user draws approximate kidney contours on every tenth slice, focusing on separating adjacent organs from the kidney. The program then performs a sequence of fully automatic steps: contour filling, interpolation, non-uniformity correction, sampling of representative parenchyma signal, and 3D binary morphology. Three independent observers applied the method to images of 40 kidneys ranging in volume from 94.6 to 254.5 cm(3). Manually constructed reference masks were used to assess accuracy. RESULTS: The volume errors for the three readers were: 4.4% ± 3.0%, 2.9% ± 2.3%, and 3.1% ± 2.7%. The relative discrepancy across readers was 2.5% ± 2.1%. The interactive processing time on average was 1.5 min per kidney. CONCLUSIONS: Pending further validation, the semi-automated method could be applied for monitoring of renal status using non-contrast MRI.


Asunto(s)
Algoritmos , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Nefropatías Diabéticas/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Riñón/diagnóstico por imagen , Adulto , Medios de Contraste , Diabetes Mellitus Tipo 2/patología , Nefropatías Diabéticas/patología , Femenino , Humanos , Aumento de la Imagen/métodos , Riñón/patología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Tamaño de los Órganos , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
20.
Eur Radiol ; 24(1): 19-25, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23884301

RESUMEN

OBJECTIVES: To evaluate the performance of diffusion-weighted imaging (DWI) against the reference standard of gadolinium-enhanced T1-weighted imaging (Gd-T1-WI) in children. METHODS: Thirty-nine consecutive patients (mean age 5.7 years) with suspected acute pyelonephritis underwent magnetic resonance imaging (MRI) including DWI and (the reference standard) Gd-T1-WI. Each study was read in double-blinded fashion by two radiologists. Each kidney was graded as normal or abnormal. Sensitivity and specificity of DWI were computed. Agreement between sequences and interobserver reproducibility were calculated (Cohen κ statistic and the McNemar tests). RESULTS: Thirty-two kidneys (41 %) had hypo-enhancing areas on Gd-T1-W images. The sensitivity and specificity of DWI were 100 % (32/32) and 93.5 % (43/46). DWI demonstrated excellent agreement (κ = 0.92,) with Gd-T1-W, with no significant difference (P = 0.25) in detection of abnormal lesions. Interobserver reproducibility was excellent with DWI (κ = 0.79). CONCLUSION: DWI enabled similar detection of abnormal areas to Gd-T1-WI and may provide an injection-free means of evaluation of acute pyelonephritis. KEY POINTS: • Diffusion weighted magnetic resonance imaging (DWI) can confirm acute pyelonepritis. • DWI provided comparable results to gadolinium enhanced T1-W MRI in acute pyelonepritis. • Contrast medium injection could be avoided for diagnosing acute pyelonephritis by MRI. • MRI with T2-WI and DWI provide a fast and comprehensive diagnostic tool.


Asunto(s)
Medios de Contraste , Imagen de Difusión por Resonancia Magnética/métodos , Gadolinio DTPA , Riñón/patología , Pielonefritis/diagnóstico , Enfermedad Aguda , Adolescente , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Lactante , Imagen por Resonancia Magnética/métodos , Masculino , Curva ROC , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA