Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circulation ; 145(13): 946-954, 2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35232217

RESUMEN

BACKGROUND: Undiagnosed atrial fibrillation (AF) may cause preventable strokes. Guidelines differ regarding AF screening recommendations. We tested whether point-of-care screening with a handheld single-lead ECG at primary care practice visits increases diagnoses of AF. METHODS: We randomized 16 primary care clinics 1:1 to AF screening using a handheld single-lead ECG (AliveCor KardiaMobile) during vital sign assessments, or usual care. Patients included were ages ≥65 years. Screening results were provided to primary care clinicians at the encounter. All confirmatory diagnostic testing and treatment decisions were made by the primary care clinician. New AF diagnoses during the 1-year follow-up were ascertained electronically and manually adjudicated. Proportions and incidence rates were calculated. Effect heterogeneity was assessed. RESULTS: Of 30 715 patients without prevalent AF (n=15 393 screening [91% screened], n=15 322 control), 1.72% of individuals in the screening group had new AF diagnosed at 1 year versus 1.59% in the control group (risk difference, 0.13% [95% CI, -0.16 to 0.42]; P=0.38). In prespecified subgroup analyses, new AF diagnoses in the screening and control groups were greater among those aged ≥85 years (5.56% versus 3.76%, respectively; risk difference, 1.80% [95% CI, 0.18 to 3.30]). The difference in newly diagnosed AF between the screening period and the previous year was marginally greater in the screening versus control group (0.32% versus -0.12%; risk difference, 0.43% [95% CI, -0.01 to 0.84]). The proportion of individuals with newly diagnosed AF who were initiated on oral anticoagulants was not different in the screening (n=194, 73.5%) and control (n=172, 70.8%) arms (risk difference, 2.7% [95% CI, -5.5 to 10.4]). CONCLUSIONS: Screening for AF using a single-lead ECG at primary care visits did not affect new AF diagnoses among all individuals aged 65 years or older compared with usual care. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03515057.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Electrocardiografía , Humanos , Tamizaje Masivo , Atención Primaria de Salud , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control
2.
Am Heart J ; 265: 92-103, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37451355

RESUMEN

BACKGROUND: Screening for atrial fibrillation (AF) using consumer-based devices capable of producing a single lead electrocardiogram (1L ECG) is increasing. There are limited data on the accuracy of physician interpretation of these tracings. The goal of this study is to assess the sensitivity, specificity, confidence, and variability of cardiologist interpretation of point-of-care 1L ECGs. METHODS: Fifteen cardiologists reviewed point-of-care handheld 1L ECGs collected from patients aged 65 years or older enrolled in the VITAL-AF clinical trial [NCT035115057] who underwent cardiac rhythm assessments with a 1L ECG using an AliveCor KardiaMobile device. Random sampling of 1L ECGs for cardiologist review was stratified by the AliveCor algorithm interpretation. A 12L ECG performed on the same day for clinical purposes was used as the gold standard. Cardiologists each reviewed a common sample of 200 1L ECG tracings and completed a survey associated with each tracing. Cardiologists were blinded to both the AliveCor algorithm and same day 12L ECG interpretation. For each tracing, study cardiologists were asked to assess the rhythm (sinus rhythm, AF, unclassifiable), report their assessment of the quality of the tracing, and rate their confidence in rhythm interpretation. The outcomes included the sensitivity, specificity, variability, and confidence in physician interpretation. Variables associated with each measure were identified using multivariable regression. RESULTS: The average sensitivity for AF was 77.4% (range 50%-90.6%, standard deviation [SD]=11.4%) and the average specificity was 73.0% (range 41.3%-94.6%, SD = 15.4%). The mean variability was 30.8% (range 0%-76.2%, SD = 23.2%). The average reviewer confidence of 1L ECG rhythm assessment was 3.6 out of 5 (range 2.5-4.2, SD = 0.6). Patient and tracing factors associated with sensitivity, specificity, variability, and confidence were identified and included age, body mass index, and presence of artifact. CONCLUSION: Cardiologist interpretation of point-of-care handheld 1L ECGs has modest diagnostic sensitivity and specificity with substantial variability for AF classification despite high confidence. Variability in cardiologist interpretation of 1L ECGs highlights the importance of confirmatory testing for diagnosing AF.

3.
Stroke ; 52(1): 181-189, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33297865

RESUMEN

BACKGROUND AND PURPOSE: Oral anticoagulation is generally indicated for cardioembolic strokes, but not for other stroke causes. Consequently, subtype classification of ischemic stroke is important for risk stratification and secondary prevention. Because manual classification of ischemic stroke is time-intensive, we assessed the accuracy of automated algorithms for performing cardioembolic stroke subtyping using an electronic health record (EHR) database. METHODS: We adapted TOAST (Trial of ORG 10172 in Acute Stroke Treatment) features associated with cardioembolic stroke for derivation in the EHR. Using administrative codes and echocardiographic reports within Mass General Brigham Biobank (N=13 079), we iteratively developed EHR-based algorithms to define the TOAST cardioembolic stroke features, revising regular expression algorithms until achieving positive predictive value ≥80%. We compared several machine learning-based statistical algorithms for discriminating cardioembolic stroke using the feature algorithms applied to EHR data from 1598 patients with acute ischemic strokes from the Massachusetts General Hospital Ischemic Stroke Registry (2002-2010) with previously adjudicated TOAST and Causative Classification of Stroke subtypes. RESULTS: Regular expression-based feature extraction algorithms achieved a mean positive predictive value of 95% (range, 88%-100%) across 11 echocardiographic features. Among 1598 patients from the Massachusetts General Hospital Ischemic Stroke Registry, 1068 had any cardioembolic stroke feature within predefined time windows in proximity to the stroke event. Cardioembolic stroke tended to occur at an older age, with more TOAST-based comorbidities, and with atrial fibrillation (82.3%). The best model was a random forest with 92.2% accuracy and area under the receiver operating characteristic curve of 91.1% (95% CI, 87.5%-93.9%). Atrial fibrillation, age, dilated cardiomyopathy, congestive heart failure, patent foramen ovale, mitral annulus calcification, and recent myocardial infarction were the most discriminatory features. CONCLUSIONS: Machine learning-based identification of cardioembolic stroke using EHR data is feasible. Future work is needed to improve the accuracy of automated cardioembolic stroke identification and assess generalizability of electronic phenotyping algorithms across clinical settings.


Asunto(s)
Accidente Cerebrovascular Embólico/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Automatización , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/diagnóstico , Bases de Datos Factuales , Registros Electrónicos de Salud , Accidente Cerebrovascular Embólico/etiología , Femenino , Humanos , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Fenotipo , Valor Predictivo de las Pruebas , Curva ROC , Sistema de Registros
4.
Am Heart J ; 215: 147-156, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31326680

RESUMEN

Given the preventable morbidity and mortality associated with atrial fibrillation (AF), increased awareness of undiagnosed AF, and advances in mobile electrocardiogram (ECG) technology, there is a critical need to assess the effectiveness of using such technology to routinely screen for AF in clinical practice. VITAL-AF is a pragmatic trial that will test whether screening for AF using a single-lead handheld ECG in individuals 65 years or older during primary care visits will lead to an increased rate of AF detection. The study is a cluster-randomized trial, with 8 primary care practices randomized to AF screening and 8 primary care practices randomized to usual care. We anticipate studying approximately 16,000 patients in each arm. During the 1-year enrollment period, practice medical assistants will screen eligible patients who agree to participate during office visits using a single-lead ECG device. Automated screening results are documented in the electronic health record, and patients can discuss screening results with their provider during the scheduled visit. All single-lead ECGs are overread by a cardiologist. Screen-detected AF is managed at the discretion of the patient's physician. The primary study end point is incident AF during the screening period. Key secondary outcomes include new oral anticoagulation prescriptions, incident ischemic stroke, and major hemorrhage during a 24-month period following the study start. Outcomes are ascertained based on electronic health record documentation and are manually adjudicated. The results of this pragmatic trial may help identify a model for widespread adoption of AF screening as part of routine clinical practice.


Asunto(s)
Fibrilación Atrial/diagnóstico , Electrocardiografía/métodos , Tamizaje Masivo/métodos , Visita a Consultorio Médico/estadística & datos numéricos , Atención Primaria de Salud/métodos , Anciano , Fibrilación Atrial/epidemiología , Registros Electrónicos de Salud , Femenino , Estudios de Seguimiento , Humanos , Masculino , Massachusetts/epidemiología , Morbilidad/tendencias
5.
Ann Neurol ; 80(3): 355-67, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27351289

RESUMEN

OBJECTIVE: Cerebrospinal fluid (CSF) tau is an excellent surrogate marker for assessing neuropathological changes that occur in Alzheimer's disease (AD) patients. However, whether the elevated tau in AD CSF is just a marker of neurodegeneration or, in fact, a part of the disease process is uncertain. Moreover, it is unknown how CSF tau relates to the recently described soluble high-molecular-weight (HMW) species that is found in the postmortem AD brain and can be taken up by neurons and seed aggregates. METHODS: We have examined seeding and uptake properties of brain extracellular tau from various sources, including interstitial fluid (ISF) and CSF from an AD transgenic mouse model and postmortem ventricular and antemortem lumbar CSF from AD patients. RESULTS: We found that brain ISF and CSF tau from the AD mouse model can be taken up by cells and induce intracellular aggregates. Ventricular CSF from AD patients contained a rare HMW tau species that exerted a higher seeding activity. Notably, the HMW tau species was also detected in lumbar CSF from AD patients, and its levels were significantly elevated compared to control subjects. HMW tau derived from CSF of AD patients was seed competent in vitro. INTERPRETATION: These findings suggest that CSF from an AD brain contains potentially bioactive HMW tau species, giving new insights into the role of CSF tau and biomarker development for AD. Ann Neurol 2016;80:355-367.


Asunto(s)
Enfermedad de Alzheimer/líquido cefalorraquídeo , Encéfalo/metabolismo , Proteínas tau/líquido cefalorraquídeo , Anciano , Animales , Biomarcadores/líquido cefalorraquídeo , Líquido Extracelular/metabolismo , Femenino , Humanos , Masculino , Ratones , Ratones Transgénicos , Persona de Mediana Edad
6.
Am J Cardiol ; 147: 44-51, 2021 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-33617814

RESUMEN

We characterized monitor utilization in stroke survivors and assessed associations with underlying clinical atrial fibrillation (AF) risk. We retrospectively analyzed consecutive patients with acute ischemic stroke 10/2018-6/2019 without prevalent AF and assessed the 6-month incidence of monitor utilization (Holter/ECG, event/patch, implantable loop recorder [ILR]) using Fine-Gray models accounting for the competing risk of death. We assessed for predictors of monitor utilization using cause-specific hazards regression adjusted for the Cohorts for Heart and Aging Research in Genomic Epidemiology AF (CHARGE-AF) score, stroke subtype, and discharge disposition. Of 493 patients with acute ischemic stroke (age 65±16; 47% women), the 6-month incidence of monitor utilization was 36.5% (95% CI 31.7, 41.3), and 6-month mortality was 13.6% (10.4, 16.8). Monitoring was performed with Holter/event (n = 107; 72.3%), ILR (n = 34; 23.0%) or both (n = 7; 4.7%). Monitoring was more likely after cryptogenic (hazard ratio [HR] 4.53 [3.22, 6.39]; 6-month monitor incidence 70.6%) and cardioembolic (HR 2.43 [1.28, 4.62]; incidence 47.7%) stroke, versus other/undocumented (incidence 22.7%). Among patients with cryptogenic stroke, the 6-month incidence of ILR was 27.5% [18.5, 36.5]. Monitoring was more likely after discharge home (HR 1.80 [1.29, 2.52]; incidence 46.1%) versus facility (incidence 24.9%). Monitoring was not associated with CHARGE-AF score (HR 1.08 per 1-SD increase [0.91, 1.27]), even though CHARGE-AF was associated with incident AF (HR 1.56 [1.03, 2.35]). In conclusion, rhythm monitors are utilized after one-third of ischemic strokes. Monitoring is more frequent after cryptogenic strokes, though ILR use is low. Monitor utilization is not associated with AF risk.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Electrocardiografía Ambulatoria/estadística & datos numéricos , Accidente Cerebrovascular Isquémico/complicaciones , Anciano , Anciano de 80 o más Años , Femenino , Hospitalización , Humanos , Incidencia , Accidente Cerebrovascular Isquémico/mortalidad , Accidente Cerebrovascular Isquémico/fisiopatología , Masculino , Persona de Mediana Edad , Utilización de Procedimientos y Técnicas , Estudios Retrospectivos , Tasa de Supervivencia , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA