Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
J Cardiovasc Electrophysiol ; 35(6): 1212-1216, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38650520

RESUMEN

BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.


Asunto(s)
Anticoagulantes , Estimulación Cardíaca Artificial , Heparina , Marcapaso Artificial , Humanos , Heparina/administración & dosificación , Heparina/efectos adversos , Masculino , Anciano , Femenino , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos , Factores de Tiempo , Factores de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad , Esquema de Medicación , Implantación de Prótesis/instrumentación , Implantación de Prótesis/efectos adversos , Diseño de Prótesis
3.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38450808

RESUMEN

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Asunto(s)
Remoción de Dispositivos , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Masculino , Femenino , Remoción de Dispositivos/efectos adversos , Anciano , Resultado del Tratamiento , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Desfibriladores Implantables , Factores de Tiempo , Marcapaso Artificial , Anciano de 80 o más Años , Dispositivos de Terapia de Resincronización Cardíaca
4.
J Cardiovasc Electrophysiol ; 35(1): 206-213, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38018417

RESUMEN

Left ventricular assist device (LVAD) implantation is an established treatment for patients with advanced heart failure refractory to medical therapy. However, the incidence of ventricular arrhythmias (VAs) is high in this population, both in the acute and delayed phases after implantation. About one-third of patients implanted with an LVAD will experience sustained VAs, predisposing these patients to worse outcomes and complicating patient management. The combination of pre-existing myocardial substrate and complex electrical remodeling after LVAD implantation account for the high incidence of VAs observed in this population. LVAD patients presenting VAs refractory to antiarrhythmic therapy and catheter ablation procedures are not rare. In such patients, treatment options are extremely limited. Stereotactic body radiation therapy (SBRT) is a technique that delivers precise and high doses of radiation to highly defined targets, reducing exposure to adjacent normal tissue. Cardiac SBRT has recently emerged as a promising alternative with a growing number of case series reporting the effectiveness of the technique in reducing the VA burden in patients with arrhythmias refractory to conventional therapies. The safety profile of cardiac SBRT also appears favorable, even though the current clinical experience remains limited. The use of cardiac SBRT for the treatment of refractory VAs in patients implanted with an LVAD are even more scarce. This review summarizes the clinical experience of cardiac SBRT in LVAD patients and describes technical considerations related to the implementation of the SBRT procedure in the presence of an LVAD.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Radiocirugia , Taquicardia Ventricular , Humanos , Radiocirugia/efectos adversos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Arritmias Cardíacas/cirugía , Insuficiencia Cardíaca/terapia , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirugía
5.
Biochem J ; 480(17): 1379-1395, 2023 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-37492947

RESUMEN

Gain-of-function missense variants in the cardiac ryanodine receptor (RyR2) are linked to catecholaminergic polymorphic ventricular tachycardia (CPVT), whereas RyR2 loss-of-function missense variants cause Ca2+ release deficiency syndrome (CRDS). Recently, truncating variants in RyR2 have also been associated with ventricular arrhythmias (VAs) and sudden cardiac death. However, there are limited insights into the potential clinical relevance and in vitro functional impact of RyR2 truncating variants. We performed genetic screening of patients presenting with syncope, VAs, or unexplained sudden death and in vitro characterization of the expression and function of RyR2 truncating variants in HEK293 cells. We identified two previously unknown RyR2 truncating variants (Y4591Ter and R4663Ter) and one splice site variant predicted to result in a frameshift and premature termination (N4717 + 15Ter). These 3 new RyR2 truncating variants and a recently reported RyR2 truncating variant, R4790Ter, were generated and functionally characterized in vitro. Immunoprecipitation and immunoblotting analyses showed that all 4 RyR2 truncating variants formed heteromers with the RyR2-wildtype (WT) protein. Each of these C-terminal RyR2 truncations was non-functional and suppressed [3H]ryanodine binding to RyR2-WT and RyR2-WT mediated store overload induced spontaneous Ca2+ release activity in HEK293 cells. The expression of these RyR2 truncating variants in HEK293 cells was markedly reduced compared with that of the full-length RyR2 WT protein. Our data indicate that C-terminal RyR2 truncating variants are non-functional and can exert a dominant negative impact on the function of the RyR2 WT protein through formation of heteromeric WT/truncation complex.


Asunto(s)
Canal Liberador de Calcio Receptor de Rianodina , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/genética , Calcio/metabolismo , Células HEK293 , Mutación , Fenotipo , Canal Liberador de Calcio Receptor de Rianodina/genética , Canal Liberador de Calcio Receptor de Rianodina/metabolismo , Taquicardia Ventricular/genética , Taquicardia Ventricular/metabolismo
6.
J Cardiovasc Electrophysiol ; 34(5): 1111-1118, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37036297

RESUMEN

INTRODUCTION: Hemodynamic decompensation during catheter ablation occurs due to prolonged procedure time and irrigant delivery directly into the cardiac chambers. Real-time hemodynamic monitoring of patients undergoing catheter ablation procedures may identify patients at risk of decompensation; we set out to assess the feasibility of a novel, real-time, intracardiac pressure monitoring system using a standard irrigated ablation catheter. METHODS: We studied 13 consecutive who underwent pressure measurement of the left atrium (LA) and left ventricle (LV) via transeptal access with a Swan Ganz (SG) catheter followed by two commercially available irrigated ablation catheters. Pressure waveform data was extracted to compare LA peak pressure, LV peak systolic pressure, LV end-diastolic pressure, and waveform analysis. RESULTS: Comparison between the SG and ablation catheters (AblA; AblB) demonstrated that LV systolic pressure (0.61-16.8 mmHg; 1.32-18.2 mmHg), and LV end-diastolic pressure (-3.4 to 2.8 mmHg; -3.0 to 3.35 mmHg) were well correlated and had accepted repeatability. Ablation waveforms demonstrated an 89.9 ± 6.4% correlation compared to SG waveforms. CONCLUSION: Pressure measurements derived from an irrigated ablation catheter are accurate and reliable when compared to an SG catheter. Further studies are needed to determine how real-time pressure monitoring can improve outcomes during ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Hemodinámica , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 34(11): 2216-2222, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37727925

RESUMEN

INTRODUCTION: Permanent pacing indications are common after cardiac surgery and transcatheter structural valve interventions. Leadless pacemakers (LPs) have emerged as a useful alternative to transvenous pacemakers. However, current commercially available LPs are unable to provide atrial pacing or cardiac resynchronization and relatively little is known about LP outcomes after cardiac surgery and transcatheter valve interventions. METHODS: This retrospective study included patients who received a Micra VR (MicraTM MC1VR01) or Micra AV (MicraTM MC1AVR1) (Medtronic) leadless pacemaker following cardiac surgery or transcatheter structural valve intervention between September 2014 and September 2022. Device performance and clinical outcomes, including ventricular pacing burden, ejection fraction, and need for conversion to transvenous pacing systems, were evaluated during follow-up. RESULTS: A total of 78 patients were included, of whom 40 received a Micra VR LP implant, and 38 received a Micra AV LP implant. The mean age of the cohort was 65.9 ± 17.9 years, and 48.1% were females. The follow-up duration for the entire cohort was 1.3 ± 1.1 years: 1.6 ± 1.3 years for the Micra VR group and 0.8 ± 0.5 years for the Micra AV group. Among the cohort, 50 patients had undergone cardiac surgery and 28 underwent transcatheter structural valve interventions. Device electrical performance was excellent during follow-up, with a small but clinically insignificant increase in ventricular pacing threshold and a slight decrease in pacing impedance. The mean right ventricle pacing (RVP) burden significantly decreased over time in the entire cohort (74.3% ± 37.2% postprocedure vs. 47.7% ± 40.6% at last follow-up, p < .001), and left ventricle ejection fraction (LVEF) showed a modest but significant downward trend during follow-up (55.0% ± 10.6% vs. 51.5% ± 11.2% p < .001). Patients with Micra VR implants had significantly reduced LVEF during follow-up (54.1% ± 11.9% vs. 48.8% ± 11.9%, p = .003), whereas LVEF appeared stable in the Micra AV group during follow-up (56.1% ± 9.0% vs. 54.6% ± 9.7%, p = .06). Six patients (7.7%) required conversion to transvenous pacing systems, four who required cardiac resynchronization for drop in LVEF with high RVP burden and two who required dual-chamber pacemakers for symptomatic sinus node dysfunction. CONCLUSION: Leadless pacemakers provide a useful alternative to transvenous pacemakers in appropriately selected patients after cardiac surgery and transcatheter structural valve interventions. Device performance is excellent over medium-term follow-up. However, a significant minority of patients require conversion to transvenous pacing systems for cardiac resynchronization or atrial pacing support, demonstrating the need for close electrophysiologic follow-up in this cohort.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Marcapaso Artificial , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Estudios Retrospectivos , Lipopolisacáridos , Resultado del Tratamiento , Diseño de Equipo , Estimulación Cardíaca Artificial/efectos adversos
8.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702135

RESUMEN

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
9.
Epilepsia ; 64(1): 184-195, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36300720

RESUMEN

OBJECTIVE: Childhood trauma has been implicated as a risk factor for the etiology of psychogenic nonepileptic seizures (PNES). Relatively little attention has been paid to whether profiles of specific trauma types differ between patients with epilepsy and PNES. Investigating childhood trauma profiles in these patient groups may identify psychological vulnerabilities that predispose to developing PNES, and aid early diagnoses, prevention, and treatment. METHODS: Data were collected from two cohorts (nRetrospective  = 203; nProspective  = 209) admitted to video-electroencephalography (EEG) monitoring units in Melbourne Australia. The differences in Childhood Trauma Questionnaire domain score between patient groups were investigated using standardized effect sizes and general linear mixed-effects models (GLMMs). Receiver-operating characteristic curves were used to investigate classification accuracy. RESULTS: In the retrospective cohort, patients diagnosed with PNES reported greater childhood emotional abuse, emotional neglect, physical abuse, sexual abuse, and physical neglect relative to patients with epilepsy. These differences were replicated in the prospective cohort, except for physical abuse. GLMMs revealed significant main effects for group in both cohorts, but no evidence for any group by domain interactions. Reported sexual abuse showed the best screening performance of PNES, although no psychometric scores were adequate as isolated measures. SIGNIFICANCE: Patients with PNES report a greater frequency of childhood trauma than patients with epilepsy. This effect appears to hold across all trauma types, with no strong evidence emerging for a particular trauma type that is more prevalent in PNES. From a practical perspective, inquiry regarding a history of sexual abuse shows the most promise as a screening measure.


Asunto(s)
Experiencias Adversas de la Infancia , Epilepsia , Convulsiones , Humanos , Experiencias Adversas de la Infancia/estadística & datos numéricos , Epilepsia/complicaciones , Epilepsia/epidemiología , Estudios Prospectivos , Estudios Retrospectivos , Convulsiones/epidemiología
10.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38000900

RESUMEN

AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.


Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Falla de Equipo , Estudios Retrospectivos
11.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38006390

RESUMEN

AIMS: The mechanisms of transition from regular rhythms to ventricular fibrillation (VF) are poorly understood. The concordant to discordant repolarization alternans pathway is extensively studied; however, despite its theoretical centrality, cannot guide ablation. We hypothesize that complex repolarization dynamics, i.e. oscillations in the repolarization phase of action potentials with periods over two of classic alternans, is a marker of electrically unstable substrate, and ablation of these areas has a stabilizing effect and may reduce the risk of VF. To prove the existence of higher-order periodicities in human hearts. METHODS AND RESULTS: We performed optical mapping of explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Signals recorded from the right ventricle endocardial surface were processed to detect global and local repolarization dynamics during rapid pacing. A statistically significant global 1:4 peak was seen in three of six hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of Periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. CONCLUSION: We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.


Asunto(s)
Ventrículos Cardíacos , Corazón , Humanos , Arritmias Cardíacas , Fibrilación Ventricular/cirugía , Potenciales de Acción/fisiología
12.
Cardiovasc Drugs Ther ; 37(3): 519-527, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35022950

RESUMEN

PURPOSE: Direct oral anticoagulants (DOACs) are not recommended in adult Fontan patients (Level of Evidence C). We hypothesized that DOACs are comparable to warfarin and do not increase thrombotic and embolic complications (TEs) or clinically significant bleeds. METHODS: We reviewed the medical records of adult Fontan patients on DOACs or warfarin at three major medical centers. We identified 130 patients: 48 on DOACs and 107 on warfarin. In total, they were treated for 810 months on DOACs and 5637 months on warfarin. RESULTS: The incidence of TEs in patients on DOACs compared to those on warfarin was not increased in a statistically significant way (hazard ratio [HR] 1.7 and p value 0.431). Similarly, the incidence of nonmajor and major bleeds in patients on DOACs compared to those on warfarin was also not increased in a statistically significant way (HR for nonmajor bleeds in DOAC patients was 2.8 with a p value of 0.167 and the HR for major bleeds was 2.0 with a p value 0.267). In multivariate analysis, congestive heart failure (CHF) was a risk factor for TEs across both groups (odds ratio [OR] = 4.8, 95% confidence interval [CI] = 1.3-17.6) and bleed history was a risk factor for clinically significant bleeds (OR = 6.8, 95% CI = 2.7-17.2). CONCLUSION: In this small, retrospective multicenter study, the use of DOACs did not increase the risk of TEs or clinically significant bleeds compared to warfarin in a statistically significant way.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Adulto , Warfarina/efectos adversos , Anticoagulantes/efectos adversos , Estudios Retrospectivos , Fibrilación Atrial/tratamiento farmacológico , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Administración Oral , Accidente Cerebrovascular/epidemiología , Estudios Multicéntricos como Asunto
13.
Ann Noninvasive Electrocardiol ; 28(5): e13073, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37515396

RESUMEN

BACKGROUND: The use of a Left Ventricular Assist Device (LVAD) in patients with advanced heart failure refractory to optimal medical management has progressed steadily over the past two decades. Data have demonstrated reduced LVAD efficacy, worse clinical outcome, and higher mortality for patients who experience significant ventricular tachyarrhythmia (VTA). We hypothesize that a novel prophylactic intra-operative VTA ablation protocol at the time of LVAD implantation may reduce the recurrent VTA and adverse events postimplant. METHODS: We designed a prospective, multicenter, open-label, randomized-controlled clinical trial enrolling 100 patients who are LVAD candidates with a history of VTA in the previous 5 years. Enrolled patients will be randomized in a 1:1 fashion to intra-operative VTA ablation (n = 50) versus conventional medical management (n = 50) with LVAD implant. Arrhythmia outcomes data will be captured by an implantable cardioverter defibrillator (ICD) to monitor VTA events, with a uniform ICD programming protocol. Patients will be followed prospectively over a mean of 18 months (with a minimum of 9 months) after LVAD implantation to evaluate recurrent VTA, adverse events, and procedural outcomes. Secondary endpoints include right heart function/hemodynamics, healthcare utilization, and quality of life. CONCLUSION: The primary aim of this first-ever randomized trial is to assess the efficacy of intra-operative ablation during LVAD surgery in reducing VTA recurrence and improving clinical outcomes for patients with a history of VTA.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Taquicardia Ventricular , Humanos , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Electrocardiografía , Arritmias Cardíacas , Taquicardia Ventricular/etiología , Resultado del Tratamiento
14.
J Appl Clin Med Phys ; 24(6): e13925, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36747376

RESUMEN

INTRODUCTION: Cardiac radioablation (CR) is a noninvasive treatment option for patients with refractory ventricular tachycardia (VT) during which high doses of radiation, typically 25 Gy, are delivered to myocardial scar. In this study, we investigate motion from cardiac cycle and evaluate the dosimetric impact in a cohort of patients treated with CR. METHODS: This retrospective study included eight patients treated at our institution who had respiratory-correlated and ECG-gated 4DCT scans acquired within 2 weeks of CR. Deformable image registration was applied between maximum systole (SYS) and diastole (DIAS) CTs to assess cardiac motion. The average respiratory-correlated CT (AVGresp ) was deformably registered to the average cardiac (AVGcardiac ), SYS, and DIAS CTs, and contours were propagated using the deformation vector fields (DVFs). Finally, the original treatment plan was recalculated on the deformed AVGresp CT for dosimetric assessment. RESULTS: Motion magnitudes were measured as the mean (SD) value over the DVFs within each structure. Displacement during the cardiac cycle for all chambers was 1.4 (0.9) mm medially/laterally (ML), 1.6 (1.0) mm anteriorly/posteriorly (AP), and 3.0 (2.8) mm superiorly/inferiorly (SI). Displacement for the 12 distinct clinical target volumes (CTVs) was 1.7 (1.5) mm ML, 2.4 (1.1) mm AP, and 2.1 (1.5) SI. Displacements between the AVGresp and AVGcardiac scans were 4.2 (2.0) mm SI and 5.8 (1.4) mm total. Dose recalculations showed that cardiac motion may impact dosimetry, with dose to 95% of the CTV dropping from 27.0 (1.3) Gy on the AVGresp to 20.5 (7.1) Gy as estimated on the AVGcardiac . CONCLUSIONS: Cardiac CTV motion in this patient cohort is on average below 3 mm, location-dependent, and when not accounted for in treatment planning may impact target coverage. Further study is needed to assess the impact of cardiac motion on clinical outcomes.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Taquicardia Ventricular , Humanos , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos , Tomografía Computarizada Cuatridimensional/métodos
15.
Epilepsy Behav ; 135: 108878, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35998513

RESUMEN

OBJECTIVE: Early differential diagnosis of psychogenic nonepileptic seizures (PNES) and epileptic seizures (ES) remains difficult. Self-reported psychopathology is often elevated in patients with PNES, although relatively few studies have examined multiple measures of psychopathology simultaneously. This study aimed to identify differences in multidimensional psychopathology profiles between PNES and ES patient groups. METHOD: This was a retrospective case-control study involving patients admitted for video-EEG monitoring (VEM) over a two-year period. Clinicodemographic variables and psychometric measures of depression, anxiety, dissociation, childhood trauma, maladaptive personality traits, and cognition were recorded. Diagnosis of PNES or ES was determined by multidisciplinary assessment and consensus opinion. General linear mixed models (GLMMs) were used to investigate profile differences between diagnostic groups across psychometric measures. A general psychopathology factor was then computed using principal components analysis (PCA) and differences between groups in this 'p' factor were investigated. RESULTS: 261 patients (77 % with ES and 23 % with PNES) were included in the study. The PNES group endorsed greater symptomatology with GLMM demonstrating a significant main effect of group (η2p = 0.05) and group by measure interaction (η2p = 0.03). Simple effects analysis indicated that the PNES group had particularly elevated scores for childhood trauma (ß = 0.78), dissociation (ß = 0.70), and depression (ß = 0.60). There was a high correlation between psychopathology measures, with a single p factor generated to explain 60 % variance in the psychometric scores. The p factor was elevated in the PNES group (ß = 0.61). ROC curve analysis indicated that these psychometric measures had limited usefulness when considered individually (AUC range = 0.63-0.69). CONCLUSION: Multidimensional psychopathological profile differences exist between patients with PNES and ES. Patients with PNES report more psychopathology overall, with particular elevations in childhood trauma, dissociation, and depression. Although not suitable to be used as a standalone screening tool to differentiate PNES and ES, understanding of these profiles at a construct level might help triage patients and guide further psychiatric examination and enquiry.


Asunto(s)
Epilepsia , Convulsiones Psicógenas no Epilépticas , Estudios de Casos y Controles , Trastornos Disociativos/complicaciones , Trastornos Disociativos/diagnóstico , Trastornos Disociativos/psicología , Electroencefalografía/métodos , Epilepsia/complicaciones , Epilepsia/diagnóstico , Epilepsia/psicología , Humanos , Estudios Retrospectivos
16.
Am J Emerg Med ; 52: 132-136, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34922232

RESUMEN

BACKGROUND: Hands-on defibrillation (HOD) could theoretically improve the efficacy of cardiopulmonary resuscitation (CPR) though a few mechanisms. Polyethylene drapes could potentially facilitate safe HOD, but questions remain about the effects of CPR on polyethylene's conductance and the magnitude of current looping through rescuers' arms in contact with patients. METHODS: This study measured the leakage current through 2 mil (0.002 in.) polyethylene through two different current pathways before and after 30 min of continuous compressions on a CPR mannequin. The two pathways analyzed were the standardized IEC (International Electrotechnical Commission) leakage current analysis and a setup analyzing a current pathway looping through a rescuer's arms and returning to the patient. First, ten measurements involving the two pathways were obtained on a single polyethylene drape. 30 min of continuous compressions were applied to the drape on a CPR mannequin after which the ten measurements were repeated. RESULTS: Twenty patients undergoing elective cardioversion for atrial fibrillation (18/20) or atrial flutter (2/20) at Emory University Hospital underwent analysis all receiving 200 J shocks (age 38-101, 35% female). Through the IEC measurement method the peak leakage current mean was 0.70 +/- 0.02 mA before compressions and 0.59 +/- 0.19 mA after compressions. Only three of the ten measurements assessing current passing through a rescuer's arms had detectable current and each was of low magnitude. All measurements were well below the maximum IEC recommendations of 3.5 mA RMS and 5.0 mA peak. CONCLUSIONS: Polyethylene may facilitate safe HOD even after long durations of compressions. Current looping through a rescuer's arms is likely of insignificant magnitude.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Cardioversión Eléctrica/métodos , Masaje Cardíaco/métodos , Adulto , Anciano , Anciano de 80 o más Años , Traumatismos por Electricidad/prevención & control , Femenino , Humanos , Masculino , Maniquíes , Persona de Mediana Edad , Polietileno/uso terapéutico
17.
J Cardiovasc Electrophysiol ; 32(2): 484-490, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33251698

RESUMEN

BACKGROUND: Data on the management of Micra transcatheter pacing system (TPS) at the time of an upgrade or during battery depletion is limited. OBJECTIVE: We sought to evaluate the management patterns of patients implanted with a Micra TPS during long-term follow-up. METHODS: We retrospectively identified patients who underwent Micra implantation from April 2014 to November 2019. We identified patients who underwent extraction (n = 11) or had an abandoned Micra (n = 12). RESULTS: We identified 302 patients who received a Micra during the period of the study. Mean age was 72.7 ± 15.4 years, 54.6% were men, and left ventricular ejection fraction was 51.9 ± 5.2%. Mean follow-up was 1105.5 ± 529.3 days. Procedural complications included pericardial tamponade (n = 1) treated with pericardiocentesis, significant rise in thresholds (n = 6) treated with reimplantation (n = 4), and major groin complications (n = 2). Indications for extraction included an upgrade to cardiac resynchronization therapy (CRT) device (n = 3), bridging after extraction of an infected transvenous system (n = 3), elevated thresholds (n = 3), and non-Micra-related bacteremia (n = 2). The median time from implantation to extraction was 78 days (interquartile range: 14-113 days), with the longest extraction occurring at 1442 days. All extractions were successful, with no procedural or long-term complications. Indications for abandonment included the need for CRT (n = 6), battery depletion (n = 2), increasing thresholds/failure to capture (n = 3), and pacemaker syndrome (n = 1). All procedures were successful, with no procedural or long-term complications. CONCLUSION: In this large single-center study, 6% of patients implanted with a Micra required a system modification during long-term follow-up, most commonly due to the requirement for CRT pacing. These patients were managed successfully with extraction or abandonment.


Asunto(s)
Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Animales , Diseño de Equipo , Humanos , Estadios del Ciclo de Vida , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
18.
Epilepsia ; 62(5): 1170-1183, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33735445

RESUMEN

OBJECTIVE: This study was undertaken to identify factors that predict discordance between the screening instruments Neurological Disorders Depression Inventory for Epilepsy (NDDI-E) and Generalized Anxiety Disorder scale (GAD-7), and diagnoses made by qualified psychiatrists among patients with seizure disorders. Importantly, this is not a validation study; rather, it investigates clinicodemographic predictors of discordance between screening tests and psychiatric assessment. METHODS: Adult patients admitted for inpatient video-electroencephalographic monitoring completed eight psychometric instruments, including the NDDI-E and GAD-7, and psychiatric assessment. Patients were grouped according to agreement between the screening instrument and psychiatrists' diagnoses. Screening was "discordant" if the outcome differed from the psychiatrist's diagnosis, including both false positive and false negative results. Bayesian statistical analyses were used to identify factors associated with discordance. RESULTS: A total of 411 patients met inclusion criteria; mean age was 39.6 years, and 55.5% (n = 228) were female. Depression screening was discordant in 33% of cases (n = 136/411), driven by false positives (n = 76/136, 56%) rather than false negatives (n = 60/136, 44%). Likewise, anxiety screening was discordant in one third of cases (n = 121/411, 29%) due to false positives (n = 60/121, 50%) and false negatives (n = 61/121, 50%). Seven clinical factors were predictive of discordant screening for both depression and anxiety: greater dissociative symptoms, greater patient-reported adverse events, subjective cognitive impairment, negative affect, detachment, disinhibition, and psychoticism. When the analyses were restricted to only patients with psychogenic nonepileptic seizures (PNES) or epilepsy, the rate of discordant depression screening was higher in the PNES group (n = 29, 47%) compared to the epilepsy group (n = 70, 30%, Bayes factor for the alternative hypothesis = 4.65). SIGNIFICANCE: Patients with seizure disorders who self-report a variety of psychiatric and other symptoms should be evaluated more thoroughly for depression and anxiety, regardless of screening test results, especially if they have PNES and not epilepsy. Clinical assessment by a qualified psychiatrist remains essential in diagnosing depressive and anxiety disorders among such patients.


Asunto(s)
Trastornos de Ansiedad/diagnóstico , Trastorno Depresivo/diagnóstico , Escalas de Valoración Psiquiátrica , Convulsiones/psicología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Neurourol Urodyn ; 40(1): 80-84, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33085772

RESUMEN

AIM: To determine the feasibility of commercially available multielectrode cardiac electrophysiology catheters to detect electrical activity in the human bladder. METHODS: Ten subjects requiring cystoscopy for the evaluation of lower urinary tract pathology were eligible for participation in our study. After routine rigid cystoscopy with a 70° cystoscope, various multielectrode cardiac electrophysiology catheters were introduced into the bladder. One of three catheters with different electrode configurations was used per subject. Electroanatomical images of the bladder were created and spontaneous electrical activity was recorded. Subjective response to electrical stimuli delivered across the electrodes (20 mA at 5 ms pulse width, rate 100 ms) was also recorded. The responses were qualitatively compared with that from a prior study. RESULTS: Electrical activity recorded at the dome of the bladder was less than 0.5 mV and low frequency. Myopotentials resembling smooth muscle were detected at electrodes near or within the trigone. A sensory response was reported with the use of pacing stimuli, with the sensation in the trigone being reported more often than the dome of the bladder. Stimulation in the trigone triggered sensory urgency and voiding in a patient with a history of overactive bladder. CONCLUSIONS: The use of multielectrode catheters to measure human bladder electrophysiologic activity is feasible. Issues with noise reduction still exist, though to a lesser extent with the multielectrode basket design than simple quadripolar one. Sensory responses to pacing stimuli may be useful for diagnostic and therapeutic purposes in the future.


Asunto(s)
Catéteres Cardíacos/normas , Fenómenos Electrofisiológicos/fisiología , Vejiga Urinaria/fisiopatología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
20.
Epilepsy Behav ; 120: 107987, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33979768

RESUMEN

OBJECTIVE: To compare the clinical, psychiatric, and cognitive characteristics of older with younger patients presenting to a video-EEG monitoring (VEM) unit. METHOD: This was a retrospective case-control study involving patients admitted for VEM over a two-year period (from April 2018 to April 2020) at two comprehensive epilepsy units. Patients were categorized into an older (≥60 years) and a younger (<60 years) group. Younger patients were individually matched to older adults to form a matched younger group. Diagnosis was determined by a consensus opinion of epileptologists, neurologists, and neuropsychiatrists. The main diagnostic categories were epilepsy, psychogenic nonepileptic seizures (PNES), and 'other' diagnosis (non-diagnostic and other nonepileptic diagnoses). Clinical psychiatric diagnoses were obtained from neuropsychiatric reports. Objective cognitive function was measured with the Neuropsychiatry Unit Cognitive Assessment Tool (NUCOG). Subjective cognitive function was assessed using the Quality of Life in Epilepsy Inventory-89 (QOLIE-89) cognitive subscales. RESULTS: Five-hundred and thirty three patients (71 older, 462 younger) aged 16-91 years were admitted to the VEM unit during the study period. There was a diagnosis of focal epilepsy in 55% of the older group and 48% of the younger group, generalized epilepsy in 3% of the older group and 10% of the younger group, and 'other' in 32% of the older group and 19% of the younger group. Ten percent (2 males and 5 females) of the older group were diagnosed with PNES compared to 22% of the younger group (p = 0.016). A depressive disorder was diagnosed in 34% of the older group and 24% of the younger group (p = 0.20). An anxiety disorder was diagnosed in 15% of the older group and 25% of the younger group (p = 0.15). Mild neurocognitive disorder was more common in the older group (34%) compared to the matched younger group (34% vs 3%, p < 0.001). The older group had lower mean NUCOG scores compared to the matched younger group (79.49 vs 87.73, p = <0.001). There was no evidence for a relationship between mean NUCOG score and overall subjective cognitive difficulties for the older group (r = 0.03, p = 0.83). Among older adults, those diagnosed with PNES had more experiences of childhood trauma. Measures of dissociation, depression, or general anxiety did not differ between PNES and non-PNES diagnoses in the older group. CONCLUSION: Psychiatric comorbidities are common among older adults admitted for VEM. The psychological impact of epilepsy and risk factors for PNES seen in younger patients are also applicable in the older group. The older group demonstrated more cognitive impairments than the younger group, although these were usually unrecognized by individuals. Older adults admitted to VEM will benefit from psychiatric and neuropsychological input to ensure a comprehensive care approach to evaluation and management.


Asunto(s)
Electroencefalografía , Calidad de Vida , Anciano , Estudios de Casos y Controles , Cognición , Femenino , Humanos , Masculino , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA