Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 32(2): 1276-1284, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34347156

RESUMEN

OBJECTIVES: Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort. METHODS: Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases. For vessel wall imaging (VWI), a high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo sequence (T1 CS-SPACE prototype) was applied post gadolinium with an isotropic resolution of 0.55 mm. Bilateral proximal intradural ICA and VA segments were evaluated for presence, morphology, and longitudinal extension of VWE. RESULTS: Concentric VWE of the proximal intradural ICA was found in 13 (30%) patients, and of the proximal intradural VA in 39 (91%) patients. Mean longitudinal extension of VWE after dural entry was 13 mm in the VA and 2 mm in the ICA. In 14 of 39 patients (36%) with proximal intradural VWE, morphology of VWE was suggestive of the mere presence of vasa vasorum. In 25 patients (64 %), morphology indicated atherosclerotic lesions in addition to vasa vasorum. CONCLUSIONS: Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in elderly subjects. Concentric VWE in these locations should not be confused with large artery vasculitis. Distal to these segments, VWE may be more likely related to pathologic conditions such as vasculitis. KEY POINTS: • Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in non-vasculitic elderly people. • Concentric enhancement within the proximal 2 mm of the intradural ICA and within the proximal 13 mm of the intradural VA portions should not be misinterpreted as vasculitis. • Distal of this, VWE is likely related to pathologic conditions, in case of concentric VWE suggestive of vasculitis.


Asunto(s)
Vasa Vasorum , Vasculitis , Anciano , Arterias Cerebrales , Humanos , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Vasa Vasorum/diagnóstico por imagen
2.
J Cardiovasc Magn Reson ; 22(1): 67, 2020 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-32912285

RESUMEN

BACKGROUND: The posterior wall of the proximal internal carotid artery (ICA) is the predilection site for the development of stenosis. To optimally prevent stroke, identification of new risk factors for plaque progression is of high interest. Therefore, we studied the impact of carotid geometry and wall shear stress on cardiovascular magnetic resonance (CMR)-depicted wall thickness in the ICA of patients with high cardiovascular disease risk. METHODS: One hundred twenty-one consecutive patients ≥50 years with hypertension, ≥1 additional cardiovascular risk factor and ICA plaque ≥1.5 mm thickness and < 50% stenosis were prospectively included. High-resolution 3D-multi-contrast (time of flight, T1, T2, proton density) and 4D flow CMR were performed for the assessment of morphological (bifurcation angle, ICA/common carotid artery (CCA) diameter ratio, tortuosity, and wall thickness) and hemodynamic parameters (absolute/systolic wall shear stress (WSS), oscillatory shear index (OSI)) in 242 carotid bifurcations. RESULTS: We found lower absolute/systolic WSS, higher OSI and increased wall thickness in the posterior compared to the anterior wall of the ICA bulb (p < 0.001), whereas this correlation disappeared in ≥10% stenosis. Higher carotid tortuosity (regression coefficient = 0.764; p < 0.001) and lower ICA/CCA diameter ratio (regression coefficient = - 0.302; p < 0.001) were independent predictors of increased wall thickness even after adjustment for cardiovascular risk factors. This association was not found for bifurcation angle, WSS or OSI in multivariate regression analysis. CONCLUSIONS: High carotid tortuosity and low ICA diameter were independent predictors for wall thickness of the ICA bulb in this cross-sectional study, whereas this association was not present for WSS or OSI. Thus, consideration of geometric parameters of the carotid bifurcation could be helpful to identify patients at increased risk of carotid plaque generation. However, this association and the potential benefit of WSS measurement need to be further explored in a longitudinal study.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Hemodinámica , Angiografía por Resonancia Magnética , Anciano , Enfermedades de las Arterias Carótidas/fisiopatología , Arteria Carótida Interna/fisiopatología , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Flujo Sanguíneo Regional , Factores de Riesgo , Estrés Mecánico
3.
Clin Oral Implants Res ; 31(8): 737-746, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32459868

RESUMEN

OBJECTIVES: The objective of this in vitro study was to assess the accuracy of fully guided implant placement following virtual implant planning based on MRI. MATERIAL AND METHODS: Sixteen human cadaver hemimandibles with single missing teeth (n = 3), partially edentulous (n = 6) and edentulous situations (n = 7) were imaged using MRI. MRI and optical scans obtained with an intraoral scanner, were imported into an implant planning software. Virtual prosthetic and implant planning were performed regarding hard- and soft-tissue anatomy. Drill guides were manufactured, and fully guided implant placement was performed. Buccal and lingual bone and implant nerve distance were measured by three examiners in preoperative MRI and postoperative CBCT. The implant position was assessed using a software for deviation of implant positions displayed in CBCT and optical scans, respectively. RESULTS: MRI displayed relevant structures for implant planning such as cortical and cancellous bone, inferior alveolar nerve and neighboring teeth. Implant planning, CAD/CAM of drill guides and guided implant placement were performed. Deviations between planned and actual implant positions in postoperative CBCT and optical scans were 1.34 mm (SD 0.84 mm) and 1.03 mm (SD 0.46 mm) at implant shoulder; 1.41 mm (SD 0.88 mm) and 1.28 mm (SD 0.52 mm) at implant apex, and 4.84° (SD 3.18°) and 4.21° (SD 2.01°). Measurements in preoperative MRI and postoperative CBCT confirmed the compliance with minimum distances of implants to anatomical structures. CONCLUSIONS: Relevant anatomical structures for imaging diagnostics in implant dentistry are displayed with MRI. The accuracy of MRI-based fully guided implant placement in vitro is comparable to the workflow using CBCT.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Mandíbula , Planificación de Atención al Paciente
4.
Clin Oral Implants Res ; 31(6): 575-583, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32105363

RESUMEN

OBJECTIVES: To present a workflow of virtual implant planning and guided implant surgery with magnetic resonance imaging (MRI) and virtual dental models without the use of ionizing radiation. METHODS: Five patients scheduled for implant placement underwent an MR examination at three Tesla using individualized 2D and 3D turbo spin-echo (TSE) sequences and dedicated head coils. The MRI data and virtual dental models derived from either optical model scans or intraoral scans were imported to a virtual implant planning software (coDiagnostiX, Dental Wings, Montreal, Canada). Virtual prosthetic planning and implant planning were performed regarding the hard and soft tissue anatomy. A drill guide was designed on the virtual dental model using computer-aided design (CAD) and manufactured in-house, using a 3D printer (Eden 260V, Stratasys, Eden Prairie, MN, USA). RESULTS: The MRI displayed all relevant anatomical structures for dental implant planning such as cortical and cancellous bone, floor of the nasal and maxillary sinus, inferior alveolar nerve and neighboring teeth. The manual alignment of virtual dental models with the MRI was possible using anatomical landmarks. Dental implant planning, CAD/CAM of a drill guide and fully guided implant placement were successfully performed. CONCLUSIONS: Guided implant surgery is feasible with MRI without ionizing radiation. Further studies will have to be conducted to study the accuracy of the presented protocol and compare it to the current workflow of guided surgery using CBCT.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Animales , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Planificación de Atención al Paciente
5.
Magn Reson Med ; 75(2): 701-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25752671

RESUMEN

PURPOSE: To compare the three different short-echo time (TE) pulse sequences ultrashort echo time (UTE), point-wise encoding time reduction with radial acquisition (PETRA), and single point imaging (SPI) for MRI of ancient remains. METHODS: MRI of mummies is challenging due to the extremely low water content and the very short transverse relaxation times T2 *. To overcome the signal loss associated with the short T2 *, three pulse sequences with very short TEs were compared. MR images of an ancient mummified human hand were acquired at field strengths of 1.5 Tesla (T) and 3T using home-made solenoid Tx/Rx radiofrequency (RF) coils. RESULTS: In all MR images, tissues could be differentiated and anatomical structures such as bones and tendons were clearly identified. Skin with embalming resin was hyperintense in MRI, whereas it appeared iso-intense in computed tomography. PETRA has the highest signal to noise ratio. With UTE, short scan times and a homogeneous RF excitation can be achieved, and blurring is less pronounced than with PETRA. SPI shows no blurring artifacts; however, it requires long scan times. CONCLUSION: This work provided an initial analysis for the optimization of imaging protocols for paleoradiology studies with MRI, and, ultimately, for MRI of tissue with extremely short T2 *.


Asunto(s)
Mano/anatomía & histología , Imagen por Resonancia Magnética/métodos , Momias , Egipto , Humanos , Aumento de la Imagen/métodos
6.
Eur Radiol ; 26(12): 4616-4623, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26910905

RESUMEN

OBJECTIVES: To ascertain the feasibility of MRI as a non-ionizing protocol for routine dentomaxillofacial diagnostic imaging. Wireless coils were used for MRI of intraoral hard and soft tissues. METHODS: FLASH MRI was applied in vivo with a mandible voxel size of 250 × 250 × 500 µm3, FOV of 64 × 64 × 28 mm3 and acquisition time of 3:57 min and with a maxilla voxel size of 350 µm3 and FOV of 34 cm3 in 6:40 min. Ex vivo imaging was performed in 4:38 min, with a resolution of 200 µm3 and FOV of 36.5 cm3. Cone beam (CB) CT of the mandible and subjects were acquired. MRI was compared to CBCT and histological sections. Deviations were calculated with intraclass correlation coefficient (ICC) and coefficient of variation (cv). RESULTS: A high congruence between CBCT, MRI and specimens was demonstrated. Hard and soft tissues including dental pulp, periodontium, gingiva, cancellous bone and mandibular canal contents were adequately displayed with MRI. CONCLUSIONS: Imaging of select intraoral tissues was achieved using custom MRI protocols with an easily applicable intraoral coil in a clinically acceptable acquisition time. Comparison with CBCT and histological sections helped demonstrate dimensional accuracy of the MR images. The course of the mandibular canal was accurately displayed with CBCT and MRI. KEY POINTS: • MRI is a clinically available diagnostic tool in dentistry • Intraoral hard and soft tissues can be imaged with a high resolution with MRI • The dimensional accuracy of MRI is comparable to cone beam CT.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Mandíbula/diagnóstico por imagen , Boca/diagnóstico por imagen , Adulto , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados
7.
J Magn Reson Imaging ; 40(6): 1437-44, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24449401

RESUMEN

PURPOSE: To demonstrate the feasibility of an algorithm for MRI whole-body quantification of internal and subcutaneous fat and quantitative comparison of total adipose tissue to air displacement plethysmography (ADP). MATERIALS AND METHODS: For comparison with ADP, whole-body MR data of 11 volunteers were obtained using a continuously moving table Dixon sequence. Resulting fat images were corrected for B1 related intensity inhomogeneities before fat segmentation. RESULTS: The performed MR measurements of the whole body provided a direct comparison to ADP measurements. The segmentation of subcutaneous and internal fat in the abdomen worked reliably with an accuracy of 98%. Depending on the underlying model for fat quantification, the resultant MR fat masses represent an upper and a lower limit for the true fat masses. In comparison to ADP, the results were in good agreement with ρ ≥ 0.97, P < 0.0001. CONCLUSION: Whole-body fat quantities derived noninvasively by using a continuously moving table Dixon acquisition were directly compared with ADP. The accuracy of the method and the high reproducibility of results indicate its potential for clinical applications.


Asunto(s)
Tejido Adiposo/anatomía & histología , Tejido Adiposo/fisiología , Adiposidad/fisiología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Pletismografía Total/métodos , Imagen de Cuerpo Entero/métodos , Adulto , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Dentomaxillofac Radiol ; 52(4): 20220333, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36988090

RESUMEN

MRI is increasingly used as a diagnostic tool for visualising the dentoalveolar complex. A comprehensive review of the current indications and applications of MRI in the dental specialities of orthodontics (I), endodontics (II), prosthodontics (III), periodontics (IV), and oral surgery (V), pediatric dentistry (VI), operative dentistry is still missing and is therefore provided by the present work.The current literature on dental MRI shows that it is used for cephalometry in orthodontics and dentofacial orthopaedics, detection of dental pulp inflammation, characterisation of periapical and marginal periodontal pathologies of teeth, caries detection, and identification of the inferior alveolar nerve, impacted teeth and dentofacial anatomy for dental implant planning, respectively. Specific protocols regarding the miniature anatomy of the dentofacial complex, the presence of hard tissues, and foreign body restorations are used along with dedicated coils for the improved image quality of the facial skull.Dental MRI poses a clinically useful radiation-free imaging tool for visualising the dentoalveolar complex across dental specialities when respecting the indications and limitations.


Asunto(s)
Endodoncia , Ortodoncia , Niño , Humanos , Nivel de Atención , Operatoria Dental , Imagen por Resonancia Magnética/métodos
9.
Crit Care Med ; 40(5): 1478-86, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22511130

RESUMEN

OBJECTIVES: Sepsis-associated changes of the arachidonic acid metabolism and the utility of arachidonic acid metabolites for the diagnosis of sepsis have been poorly investigated so far. Therefore, the primary objective of our study was to screen for differentially regulated arachidonic acid metabolites in septic patients using a lipopolysaccharide whole-blood model and to investigate their diagnostic potential. DESIGN: Prospective, observational, single-center, clinical study. SETTING: Intensive care unit at University Hospital Leipzig. PATIENTS: Thirty-five patients (first cohort 25 patients, second cohort 10 patients) meeting the criteria for severe sepsis or septic shock were enrolled. Eighteen healthy volunteers (first cohort 15 subjects, second cohort 3 subjects) were enrolled as controls. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Arachidonic acid and its metabolites were investigated in supernatants of nonactivated (baseline) and lipopolysaccharide-activated heparinized whole blood of healthy subjects (n=15) and septic patients (n=25) by solid phase extraction and subsequent liquid chromatography-tandem mass spectrometry. Arachidonic acid, arachidonic acid analogues, and the cyclooxygenase-associated metabolites prostaglandin E2, 11-hydroxyeicosatetraenoic acid, and thromboxane B2 were identified as differentiating metabolites between septic patients and healthy subjects. Some of these compounds, including arachidonic acid, its analogues, and the cyclooxygenase metabolites prostaglandin E2 and thromboxane B2 differed at baseline. The inducibility of arachidonic acid and the cyclooxygenase metabolites 11-hydroxyeicosatetraenoic and prostaglandin E2 were reduced by 80% to 90% in septic patients. The degree of the inducibility was associated with severity of sepsis and clinical outcome. A reduced inducibility of COX-2 but preserved inducibility of mPGES-1 on gene expression level were confirmed in an independent cohort of septic patients (n=10) by quantitative reverse-transcription polymerase chain reaction compared to healthy controls (n=3). CONCLUSIONS: Arachidonic acid metabolism is markedly affected in patients with sepsis. Our data suggest that the analysis of arachidonic acid metabolites in an in vitro whole blood activation model may be a promising approach for risk estimation in septic patients that has to be further evaluated in subsequent large-scale clinical studies.


Asunto(s)
Ácido Araquidónico/metabolismo , Sepsis/metabolismo , Adulto , Anciano , Ácido Araquidónico/sangre , Cromatografía Liquida , Dinoprostona/sangre , Femenino , Humanos , Ácidos Hidroxieicosatetraenoicos/sangre , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sepsis/sangre , Sepsis/diagnóstico , Choque Séptico/sangre , Choque Séptico/diagnóstico , Choque Séptico/metabolismo , Espectrometría de Masas en Tándem , Tromboxano B2/sangre , Adulto Joven
10.
J Magn Reson Imaging ; 36(4): 841-6, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22707436

RESUMEN

PURPOSE: To evaluate the ability of conventional and ultra-short or zero echo time MRI for imaging of soft and solid dental components in and ex vivo. MATERIALS AND METHODS: Turbo spin echo (TSE), ultra-short echo time (UTE), and zero echo time (ZTE) MRI were performed on extracted (human and equine) teeth and in vivo using whole-body and small-bore MR systems at 3 T, 7T, and 9.4T, respectively. RESULTS: At an isotropic resolution of (600 µm)(3) , strong signal of soft-tissue, e.g., mucosa and nerves with excellent contrast was achieved using TSE at 3T in vivo. No signal, though, was obtained from solid components, e.g., teeth (due to short T(2) ). In contrast, dentin, cementum as well as enamel of extracted teeth were readily depicted using UTE and ZTE at a resolution of ≈ (150 µm)(3) at 7T and 9.4T. In particular, ZTE provided higher signal in enamel. CONCLUSION: As an alternative to X-ray based methods like cone-beam computed tomography (CT) or conventional CT, the presented results demonstrate the potential of ZTE and UTE MRI as a radiation-free imaging modality, delivering contrast of soft and solid components at the same time.


Asunto(s)
Tejido Conectivo/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Diente Molar/patología , Enfermedades Dentales/patología , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
J Comput Assist Tomogr ; 36(5): 591-5, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22992611

RESUMEN

A fast and spatially seamless peripheral vessel scout is desirable for subsequent planning of magnetic resonance (MR) angiography. We implemented a continuously moving table sequence providing projection data with time-of-flight contrast of the entire lower extremities in less than 2 minutes. Variation of arterial signal during the cardiac cycle and autocorrelation were exploited to enhance vessel-to-background contrast. Subjective image analysis revealed excellent vessel depiction, indicating that the proposed scout allows for seamless expedited visualization of major arterial structures.


Asunto(s)
Extremidad Inferior/irrigación sanguínea , Angiografía por Resonancia Magnética/métodos , Adulto , Arteriopatías Oclusivas/diagnóstico , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Enfermedades Vasculares Periféricas/diagnóstico , Estadísticas no Paramétricas
12.
Phys Med ; 97: 59-65, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35413606

RESUMEN

BACKGROUND: MRI is a frequently used tool in radiation therapy planning. For MR-based tumor segmentation, diffusion weighted imaging plays a major role, which can fail due to excessive image artifacts for head and neck cancer imaging. Here, an easy-to-use setup is presented for imaging of head and neck cancer patients in a radiotherapy thermoplastic fixation mask. METHODS: In a prospective head and neck cancer study, MRI data of 29 patients has been acquired at 3 different time points during radiation treatment. The data was analyzed with respect to Nyquist ghosting artifacts in the diffusion images in conventional single shot and readout segmented EPI sequences. For 9 patients, an improved setup with water bags for B0 homogenization was used, and the impact on artifact frequency was analyzed. Additionally, volunteer measurements with B0 fieldmaps are presented. RESULTS: The placement of water bags to the sides of the head during MRI measurements significantly reduces artefacts in diffusion MRI. The number of artifact-free images in readout segmented EPI increased from 74% to 95% of the cases. Volunteer measurements showed a significant increase in B0 homogeneity across slices (head foot direction) as well as within each slice. CONCLUSIONS: The placement of water bags for B0 homogenization is easy to implement, cost-efficient and does not impact patient comfort. Therefore, if very sophisticated soft- or hardware solutions are not present at a given site, or cannot be implemented due to restrictions from the thermoplastic mask, this is an excellent alternative to reduce artifacts in diffusion weighted imaging.


Asunto(s)
Imagen Eco-Planar , Neoplasias de Cabeza y Cuello , Artefactos , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Estudios Prospectivos , Agua
13.
Invest Radiol ; 57(3): 163-170, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34510099

RESUMEN

OBJECTIVES: Accurate visualization of dental root canals is vital for the correct diagnosis and subsequent treatment. This work assesses the improvement of a dedicated new coil for dental magnetic resonance imaging (MRI) in comparison to conventional ones in terms of signal-to-noise ratio (SNR) and visibility. MATERIALS AND METHODS: A newly developed intraoral flexible coil was used to display dental roots with MRI, and it provides improved sensitivity with a loop design and size adjusted to a single tooth anatomy. Ex vivo and in vivo measurements were performed on a 3 T clinical MR system, and results were compared with conventional head and surface coil images. Additional comparison was performed with a modified fast spin echo sequence and a constructive interference in steady-state sequence. RESULTS: Ex vivo, an SNR gain of 6.3 could be achieved with the intraoral flexible coil setup, and higher visibility down to 200 µm was possible, whereas the external loop coil is limited to 400 µm. In vivo measurements in a volunteer resulted in an SNR gain of up to 4.5 with an improved delineation of the root canals, especially for the branch tissue splitting of the mesial root canal into mesial-buccal and mesial-lingual. CONCLUSIONS: In summary, we showed the feasibility of implementing a wireless coil approach with readily available dental practice materials for sealing and placement. Highly improved MRI scans can be acquired within clinically feasible scan times, and this might provide additional medical findings to supplement available x-ray images.


Asunto(s)
Cavidad Pulpar , Imagen por Resonancia Magnética , Cavidad Pulpar/diagnóstico por imagen , Diseño de Equipo , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Relación Señal-Ruido
14.
Invest Radiol ; 57(11): 720-727, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35640007

RESUMEN

OBJECTIVES: The aims of this study were to quantify T1/T2-relaxation times of the dental pulp, develop a realistic tooth model, and compare image quality between cone-beam computed tomography (CBCT) and high-resolution magnetic resonance imaging (MRI) of single teeth using a wireless inductively coupled intraoral coil. METHODS: T1/T2-relaxometry was performed at 3 T in 10 healthy volunteers (283 teeth) to determine relaxation times of healthy dental pulp and develop a realistic tooth model using extracted human teeth. Eight MRI sequences (DESS, CISS, TrueFISP, FLASH, SPACE, TSE, MSVAT-SPACE, and UTE) were optimized for clinically applicable high-resolution imaging of the dental pulp. In model, image quality of all sequences was assessed quantitatively (contrast-to-noise ratio) and qualitatively (visibility of anatomical structures and extent of susceptibility artifacts using a 5-point scoring scale). Cone-beam computed tomography served as the reference modality for qualitative assessment. Statistical analysis was performed using 2-way analysis of variance, Fisher exact test, and Cohen κ. RESULTS: In vivo, relaxometry of dental pulps revealed T1/T2 relaxation times at 3 T of 738 ± 100/171 ± 36 milliseconds. For all sequences, an isotropic resolution of (0.21 mm) 3 was achieved, with acquisition times ranging from 6:19 to 8:02 minutes. In model, the highest contrast-to-noise ratio values were observed for UTE, followed by TSE and CISS. The best image/artifact quality, however, was found for DESS (mean ± SD: 1.3 ± 0.3/2.2 ± 0.0), FLASH (1.5 ± 0.3/2.4 ± 0.1), and CISS (1.5 ± 0.4/2.5 ± 0.1), at a level comparable to CBCT (1.2 ± 0.3/2.1 ± 0.1). CONCLUSIONS: Optimized MRI protocols using an intraoral coil at 3 T can achieve an image quality comparable to reference modality CBCT within clinically applicable acquisition times. Overall, DESS revealed the best results, followed by FLASH and CISS.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Imagen por Resonancia Magnética/métodos
15.
Magn Reson Med ; 65(6): 1557-63, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21432899

RESUMEN

In this study, a method for whole-body diffusion-weighted imaging (wbDWI) during continuous table motion has been developed and implemented on a clinical scanner based on a short-Tau inversion recovery echo-planar DWI sequence. Unlike currently available multistation wbDWI, which has disadvantages such as long scanning times, poor image quality, and troublesome data realignment, continuously moving table wbDWI can overcome these technical problems while extending the longitudinal field of view in MRI systems. In continuously moving table wbDWI, images are acquired consecutively at the isocenter of the magnet, having less geometric distortions and various possibilities of spatial and temporal coverage of an extended field of view. The acquired images, together with an apparent diffusion coefficient analysis, show that continuously moving table wbDWI can be used by appropriately adapting the table velocity, scan range, radiofrequency coils, slice resolutions, and spatio-temporal acquisition schemes according to various clinical demands.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/instrumentación , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Cuerpo Entero/instrumentación , Imagen de Cuerpo Entero/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Fantasmas de Imagen
16.
Dentomaxillofac Radiol ; 50(2): 20200068, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201739

RESUMEN

OBJECTIVES: Autologous bone grafts are the gold standard to augment deficient alveolar bone. Dimensional graft alterations during healing are not known as they are not accessible to radiography. Therefore, MRI was used to display autologous onlay bone grafts in vivo during early healing. METHODS AND MATERIALS: Ten patients with alveolar bone atrophy and autologous onlay grafts were included. MRI was performed with a clinical MR system and an intraoral coil preoperatively (t0), 1 week (t1), 6 weeks (t2) and 12 weeks (t3) postoperatively, respectively. The graft volumes were assessed in MRI by manual segmentation by three examiners. Graft volumes for each time point were calculated and dimensional alteration was documented. Cortical and cancellous proportions of bone grafts were assessed. The intraobserver and interobserver variability were calculated. Statistical analysis was performed using a mixed linear regression model. RESULTS: Autologous onlay bone grafts with cortical and cancellous properties were displayed in vivo in eight patients over 12 weeks. The fixation screws were visible as signal voids with a thin hyperintense fringe. The calculated volumes were between 0.12-0.74 cm3 (t1), 0.15-0.73 cm3 (t2), and 0.17-0.64 cm3 (t3). Median changes of bone graft volumes of -15% were observed. There was no significant difference between the examiners (p = 0.3). CONCLUSIONS: MRI is eligible for the display and longitudinal observation of autologous onlay bone grafts. Image artifacts caused measurements deviations in some cases and minimized the precise assessment of graft volume. To the knowledge of the authors, this is the first study that used MRI for the longitudinal observation of autologous onlay bone grafts.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Trasplante Óseo , Huesos , Humanos , Imagen por Resonancia Magnética , Cicatrización de Heridas
17.
Front Cardiovasc Med ; 8: 723860, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34765650

RESUMEN

Introduction: Carotid geometry and wall shear stress (WSS) have been proposed as independent risk factors for the progression of carotid atherosclerosis, but this has not yet been demonstrated in larger longitudinal studies. Therefore, we investigated the impact of these biomarkers on carotid wall thickness in patients with high cardiovascular risk. Methods: Ninety-seven consecutive patients with hypertension, at least one additional cardiovascular risk factor and internal carotid artery (ICA) plaques (wall thickness ≥ 1.5 mm and degree of stenosis ≤ 50%) were prospectively included. They underwent high-resolution 3D multi-contrast and 4D flow MRI at 3 Tesla both at baseline and follow-up. Geometry (ICA/common carotid artery (CCA)-diameter ratio, bifurcation angle, tortuosity and wall thickness) and hemodynamics [WSS, oscillatory shear index (OSI)] of both carotid bifurcations were measured at baseline. Their predictive value for changes of wall thickness 12 months later was calculated using linear regression analysis for the entire study cohort (group 1, 97 patients) and after excluding patients with ICA stenosis ≥10% to rule out relevant inward remodeling (group 2, 61 patients). Results: In group 1, only tortuosity at baseline was independently associated with carotid wall thickness at follow-up (regression coefficient = -0.52, p < 0.001). However, after excluding patients with ICA stenosis ≥10% in group 2, both ICA/CCA-ratio (0.49, p < 0.001), bifurcation angle (0.04, p = 0.001), tortuosity (-0.30, p = 0.040), and WSS (-0.03, p = 0.010) at baseline were independently associated with changes of carotid wall thickness at follow-up. Conclusions: A large ICA bulb and bifurcation angle and low WSS seem to be independent risk factors for the progression of carotid atherosclerosis in the absence of ICA stenosis. By contrast, a high carotid tortuosity seems to be protective both in patients without and with ICA stenosis. These biomarkers may be helpful for the identification of patients who are at particular risk of wall thickness progression and who may benefit from intensified monitoring and treatment.

18.
Dentomaxillofac Radiol ; 50(3): 20200290, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32915672

RESUMEN

OBJECTIVE: To evaluate a novel liquid fiducial marker for intraoperative marking of the tumour resection surface in oral cancer patients to facilitate precise postoperative delineation of the interface between the tumour resection border and reconstructed tissue for intensity-modulated radiation therapy. METHODS: A total of 200 markers were created by injecting the volumes of 10 µl, 20 µl, 30 µl, 40 µl and 50 µl of a liquid marker composed of sucrose acetoisobutyrate (SAIB) and iodinated sucrose acetoisobutyrate (x-SAIB) into the soft tissue of porcine mandible segments. Visibility of the resulting markers was quantified by threshold-based segmentation of the marker volume in CT- and CBCT imaging and by a comparison of signal intensities in MRI. RESULTS: Even the lowest volume of SAIB-/x-SAIB investigated (10 µl) resulted in a higher visibility (CTSoft tissue: 88.18 ± 13.23 µl; CTBone: 49.55 ± 7.62 µl; CBCT: 54.65 ± 12.58 µl) than observed with the incorporation of titanium ligature clips (CTSoft tissue: 50.15 ± 7.50 mm3; CTBone: 23.90 ± 3.39 mm3; CBCT: 33.80 ± 9.20 mm3). Markers created by the injection of 10 µl and 20 µl could reliably be delineated from markers created by the injection of higher volumes. CONCLUSION: SAIB/x-SAIB, which has recently become available as a Conformité Européenne (CE)-marked fiducial marker, provides an option for fast and reliable production of markers with excellent visibility in imaging modalities used in oral cancer radiation therapy (RT) planning routine.


Asunto(s)
Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Radioterapia Guiada por Imagen , Animales , Marcadores Fiduciales , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Imagen por Resonancia Magnética , Porcinos
19.
Magn Reson Imaging ; 83: 114-124, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34403760

RESUMEN

OBJECTIVE: Assessment of vessel walls is an integral part in diagnosis and disease monitoring of vascular diseases such as vasculitis. Vessel wall imaging (VWI), in particular of intracranial arteries, is the domain of Magnetic Resonance Imaging (MRI) - but still remains a challenge. The tortuous anatomy of intracranial arteries and the need for high resolution within clinically acceptable scan times require special technical conditions regarding the hardware and software environments. MATERIALS AND METHODS: In this work a dedicated framework for intracranial VWI is presented offering an optimized, black-blood 3D T1-weighted post-contrast Compressed Sensing (CS)-accelerated MRI sequence prototype combined with dedicated 3D-GUI supported post-processing tool for the CPR visualization of tortuous arbitrary vessel structures. RESULTS: Using CS accelerated MRI sequence, the scanning time for high-resolution 3D black-blood CS-space data could be reduced to under 10 min. These data are adequate for a further processing to extract straightened visualizations (curved planar reformats - CPR). First patient data sets could be acquired in clinical environment. CONCLUSION: A highly versatile framework for VWI visualization was demonstrated utilizing a post-processing tool to extract CPR reformats from high-resolution 3D black-blood CS-SPACE data, enabling simplified and optimized assessment of intracranial arteries in intracranial vascular disorders, especially in suspected intracranial vasculitis, by stretching their tortuous course. The processing time from about 15-20 min per patient (data acquisition and further processing) allows the integration into clinical routine.


Asunto(s)
Trastornos Cerebrovasculares , Imagenología Tridimensional , Trastornos Cerebrovasculares/diagnóstico por imagen , Humanos , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética
20.
Clin Neuroradiol ; 31(1): 207-216, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31853612

RESUMEN

BACKGROUND AND PURPOSE: In vasculopathies of the central nervous system, reliable and timely diagnosis is important against the background of significant morbidity and sequelae in cases of incorrect diagnosis or delayed treatment. Magnetic resonance imaging (MRI) plays a major role in the detection and monitoring of intracranial and extracranial vascular pathologies of different etiologies, in particular for evaluation of the vessel wall in addition to luminal information, thus allowing differentiation between various vasculopathies. Compressed-sensing black-blood MRI combines high image quality with relatively short acquisition time and offers promising potential in the context of neurovascular vessel wall imaging in clinical routine. This case review gives an overview of its application in the diagnosis of various intracranial and extracranial entities. METHODS: An optimized high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo technique (T1 CS-SPACE prototype) precontrast and postcontrast application at 3T was used for the evaluation of various vascular conditions in neuroradiology. RESULTS: In this article seven cases of intracranial and extracranial arterial and venous vasculopathies with representative imaging findings in high-resolution compressed-sensing black-blood MRI are presented. CONCLUSION: High-resolution 3D T1 CS-SPACE black-blood MRI is capable of imaging various vascular entities in high detail with whole head coverage and low susceptibility for motion artifacts and within acceptable scan times. It represents a highly versatile, non-invasive technique for the visualization and differentiation of a wide variety of neurovascular arterial and venous disorders.


Asunto(s)
Angiografía por Resonancia Magnética , Neuroimagen , Artefactos , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Movimiento (Física)
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA