RESUMEN
INTRODUCTION: The Pavlik harness is a commonly used treatment for developmental dysplasia of the hip (DDH) of types IIc or worse, based on the Graf classification. This study aimed to assess the long-term follow-up outcomes after treating DDH with the Pavlik harness. METHODS: Between 1995 and 2006, ultrasound screening was conducted on 7372 newborns within the first days of life. Among them, 203 dysplastic hips in 152 patients, whose sonograms were Graf type IIc or worse, were treated with Pavlik harness. Treatment was discontinued if the measurement indicated Graf type Ia/b. More than 20 years later (mean: 20.46 y), patients were invited for clinical evaluation (Oxford Hips Score, Schulthess Hip Score, Harris Hip Score) and radiologic examination (center-edge angle according to Wiberg and the Severis classification, the rate of roofing of the femoral head via the Reimers migration percentage, and the Sharp angle). RESULTS: Of the 152 patients, 60 (39.5%) participants with 80 (39.4%) affected hips (57.7% type IIc, 7.9% type D, and 15.6% type IIIa/b) were reexamined. The average follow-up duration was 20.5 years, with a maximum of 25.9 years. According to the Severin's classification, only 2 (3.77%) patients, each with one affected hip, showed slight residual dysplasia. The Reimer's migration percentage indicated an average of almost 90% canopy cover in the patient collective studied. No avascular necrosis was found, and the Sharp angle showed an average of almost 38 degrees. Only 4 participants with each one affected hip showed residual dysplasia according to the Sharp angle. The clinical results were quite satisfying, as none of the patients experienced hip pain that significantly limited their everyday activities or sports engagement, requiring medical attention before this study.Conclusions:Conservative therapy of DDH (Graf type IIc, D, III) with the Pavlik harness has demonstrated very good therapeutic success and a very low rate of residual dysplasia (2.81%). Both the radiologic and clinical outcomes were highly satisfactory. LEVEL OF EVIDENCE: Level IV.
Asunto(s)
Displasia del Desarrollo de la Cadera , Luxación Congénita de la Cadera , Humanos , Recién Nacido , Lactante , Articulación de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/terapia , Aparatos Ortopédicos , Estudios Retrospectivos , Resultado del Tratamiento , UltrasonografíaRESUMEN
BACKGROUND: In recent years, the indication for cementless short stem total hip arthroplasty (THA) has been widened to elderly patients as they might profit by the advantages of the short-curved implant design as well. Therefore, this study was conducted to evaluate the clinical and radiological outcome of a cementless short stem in elderly patients (≥ 75 years) compared to a young control group (≤ 60 years). METHODS: A retrospective cohort of 316 THAs performed between 2014 and 2017 was prospectively examined. In all patients a cementless, curved short stem and press-fit cup (Fitmore® stem; Allofit®/-S cup; both ZimmerBiomet, Warsaw, IN, USA) were implanted via a minimally-invasive anterolateral approach. Clinical and radiological outcome as well as rate of complications and revision were assessed. RESULTS: In total, 292 patients have been included for analysis of complications and revisions (Øfollow-up: 4.5 years) and 208 patients for clinical and radiological outcome (Øfollow-up: 4.4 years). Complication rate was significantly increased in elderly patients (13.7% vs. 5.8%, p = 0.023), while the revision rate was increased without statistical significance (5.2% vs. 2.2%, p = 0.169). Periprosthetic fractures occurred significantly higher in the elderly patients (5.2% vs. 0.7%; p = 0.026). Both groups showed a comparable clinical outcome in the Harris Hip Score (93.7 vs. 91.9; p = 0.224), Oxford Hip Score (44.5 vs. 43.7; p = 0.350), Forgotten Joint Score (81.7 vs. 81.5; p = 0.952) and WOMAC (7.4 vs. 9.3; p = 0.334). CONCLUSION: Cementless short stem total hip arthroplasty shows a comparable clinical and radiological outcome in patients over 75 years of age compared to younger patients under 60 years of age. However, cementless shorts stem THA shows an increased rate of overall complications and periprosthetic fractures in elderly patients over 75 years of age. Cemented fixation of the femoral component should be considered in patients over 75 years of age. LEVEL OF EVIDENCE: III Case-controlled study. TRIAL REGISTRATION: Observational study without need for trial registration due to ICMJE criteria.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Diseño de Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Anciano , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Reoperación/estadística & datos numéricos , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Factores de Edad , Estudios de Factibilidad , Resultado del TratamientoRESUMEN
INTRODUCTION: Implementing new approaches or new implants is always related with a certain learning curve in total hip arthroplasty (THA). Currently, many surgeons are switching to minimally invasive approaches combined with short stems for performing THA. Therefore, we aimed to asses and compare the learning curve of switching from an anterolateral Watson Jones approach (ALA) to a direct anterior approach (DAA) with the learning curve of switching from a neck-resecting to a partially neck-sparing short stem in cementless THA. MATERIALS AND METHODS: The first 150 consecutive THA performed through a DAA (Group A) and the first 150 consecutive THA using a partially neck-sparing short stem (Group B) performed by a single surgeon were evaluated within this retrospective cohort study. All cases were screened for surgery related adverse events (AE). Furthermore, the operative time of each surgery was evaluated and the learning curve assessed performing a cumulative sum (CUSUM) analysis. RESULTS: Overall, significantly more AE occurred in Group A compared to Group B (18.0% vs. 10.0%; p = 0.046). The sub-analysis of the AE revealed higher rates of periprosthetic joint infections (2.7% vs. 0.7%; p = 0.176), periprosthetic fractures (4.0% vs. 2.0%; p = 0.310) and overall revisions (4.7% vs. 1.3% p = 0.091) within Group A without statistical significance. The CUSUM analysis revealed a consistent reduction of operative time after 97 cases in Group A and 79 cases in Group B. CONCLUSION: A significantly higher overall rate of AE was detected while switching approach compared to switching implant for performing THA. However, according to the results of this study, surgeons should be aware of the learning curve of the adoption to a new implant with different fixation philosophy as well.
RESUMEN
BACKGROUND: The pelvic and femoral morphology are associated with the occurrence of early periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA). Differences exist depending on the performed approach and implanted stem design. Therefore, this study was conducted to analyze the pelvic and femoral morphology in cementless short stem THA via a minimally-invasive (MIS) anterolateral approach. METHODS: A retrospective, single-center, multi-surgeon, comparative propensity-score matched study of a cohort of 1826 short stem THAs was conducted. A total of 39 PFFs within the first 90 days after surgery was matched on a 2:1 ratio to non-fracture patients. The morphology of the proximal femur was analyzed with canal flare index (CFI), canal-calcar ratio (CCR), canal-bone ratio (CBR), morphological cortical index (MCI), and femoral cortical index (CI). The pelvic morphology was analyzed with ilium-ischial ratio (IR), distance anterior superior iliac spine to the tip of the greater trochanter (AGT). Both groups were analyzed regarding several parameters for femoral and pelvic morphology in non-parametric testing and univariate regression analysis. RESULTS: A significantly higher AGT was detected in the fracture group (104.5 mm ± 18 versus 97.4 mm ± 9.8; p = 0.016). All other femoral and pelvic parameters did not differ between both groups, also when compared depending on the Vancouver type of the PFF. CONCLUSIONS: The morphology of the proximal femur and the pelvis do not differ in several radiological parameters in patients sustaining a PFF in cementless short stem THA via an anterolateral approach compared with matched non-fracture group. The findings are controversial to other studies with different stem types and approaches. Future studies should focus on analyzing the influence of the pelvic geometry and the shape of the proximal femur in the occurrence of PFFs in different approaches with the same stem type and vice versa. Level of Evidence Level III case-controlled study.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Huesos Pélvicos , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Masculino , Estudios Retrospectivos , Femenino , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/diagnóstico por imagen , Anciano , Persona de Mediana Edad , Huesos Pélvicos/lesiones , Diseño de Prótesis , Puntaje de Propensión , Fémur/cirugía , Fémur/diagnóstico por imagen , Procedimientos Quirúrgicos Mínimamente Invasivos/métodosRESUMEN
PURPOSE: The purpose of this study was to investigate the learning curve associated with robotic assisted knee arthroplasty (RAS KA). Therefore, the evaluation of the influence of an experienced surgeon on the overall team performance of three surgeons regarding the learning curve in RAS KA was investigated. It was hypothesized that the presence of an experienced surgeon flattens the learning curve and that there was no inflection point for the learning curve of the surgical team. METHODS: Fifty-five cases consisting of 31 total knee arthroplasties (TKA) and 24 unicompartmental arthroplasties (UKA) performed by three surgeons during 2021 were prospectively investigated. Single surgeon and team performance for operation time learning curve and inflection points were investigated using cumulative sum analysis (CUSUM). RESULTS: A downward trend line for individual surgeons and the team performance regarding the operation time learning curve was observed. No inflexion point was observed for the overall team performance regarding TKA and UKA. The surgeon that performed all cases with the assistance of the experienced surgeon had significantly shorter surgical times than the surgeon that only occasionally received assistance from the experienced surgeon (p = 0.004 TKA; p = 0.002 UKA). CONCLUSION: The presence of an experienced surgeon in robotically assisted knee arthroplasty can flatten the learning curve of the surgical team formerly unexperienced in robotic assisted systems. Manufacturers should provide expanded support during initial cases in centres without previous experience to robotic assisted knee arthroplasty. LEVEL OF EVIDENCE: III.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Cirujanos , Humanos , Curva de Aprendizaje , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Resultado del TratamientoRESUMEN
BACKGROUND: Recent studies indicate a decreased risk of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) for short compared to straight stems. However, the results are still inconclusive. Therefore, we retrospectively investigated the rate of PFFs within the first year between cementless short and straight stem THA. METHODS: A 1:1 propensity score matching of 3,053 THAs was performed. Two groups including 1,147 short stem THAs implanted through a minimally invasive antero-lateral approach and 1,147 straight stem THAs implanted through a transgluteal Hardinge approach were matched. The rates of PFFs and fracture patterns were compared between both stem types. Risk factors for PFFs were analyzed by multivariate regression analyses. RESULTS: The overall rate of PFFs was 1.7% in short stem THA and 3.2% in straight stem THA (P = .015). Postoperatively detected Vancouver A fractures occurred significantly more often in straight stem THA (P = .002), while the occurrence Vancouver B fractures did not differ significantly (P = .563). The risk of PFFs was significantly increased for women in straight stem THA (Odds ratio (OR) 2.620; Confidence Interval (CI) 1.172-5.856; P = .019). Increasing age showed a significantly increased odds ratio in short stem (OR 1.103; CI 1.041-1.169, P < .001) and straight stem THA (OR 1.057; CI 1.014-1.101, P = .008). CONCLUSION: Short stem THA reduces Vancouver Type A PFFs in the trochanteric region compared to straight stem THA, while Vancouver Type B fractures are comparable. Increasing age is a significant risk factor for both stem types, while the risk for PFFs in women was only significantly increased in the straight stem group.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Femenino , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Puntaje de Propensión , Diseño de Prótesis , Fracturas del Fémur/cirugía , Fracturas Periprotésicas/cirugía , Factores de Riesgo , Reoperación/efectos adversosRESUMEN
INTRODUCTION: Increased risk of periprosthetic joint infection (PJI) in minimally invasive (MIS) total hip arthroplasty (THA) is still debated. This study aimed to identify differences in surgical and patient-related risk factors for PJI between an MIS anterolateral approach and transgluteal-modified Hardinge approach. METHODS: A retrospective cohort of 5315 THAs performed between 2006 and 2019 at a single institution was screened. Short stem THAs performed via an MIS anterolateral approach in the supine position and standard straight stem THAs performed via a transgluteal modified Hardinge approach were included. Propensity score matching was performed to control for selection bias. After matching, 1405 (34.3%) short stem THAs implanted via MIS anterolateral approach and 2687 (65.7%) straight stem THAs implanted via a transgluteal modified Hardinge approach were included. The risk of PJI due to patient-specific and surgical factors was retrospectively analyzed using chi-square test and multivariate regression analysis. RESULTS: PJI occurred in 1.1% in both MIS anterolateral and transgluteal approach (p = 0.823). Multivariate regression showed an increased infection risk for patients with a BMI between 35 and 39.99 kg/m2 (OR 6.696; CI 1.799-24.923; p = 0.005), which could not be demonstrated for transgluteal approach (OR 0.900; CI 0.900-4.144; p = 0.93). A BMI ≥ 40 kg/m2 (OR 14.150; CI 2.416-82.879; p = 0.003) was detected as a risk factor for PJI only in anterolateral approach. Increased operation time ≥ 121 min showed a significantly increased risk for PJI in the general cohort (OR 6.989; CI1.286-37.972; p = 0.024). CONCLUSION: Minimally invasive anterolateral and transgluteal THA show a comparable rate of early PJI within the first year of index surgery. A BMI of ≥ 35 kg/m2 was detected as a clear risk factor for infection in the anterolateral approach. Prolonged operation time ≥ 121 min increases the risk of PJI regardless of approach.
Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios Retrospectivos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Puntaje de Propensión , Prótesis de Cadera/efectos adversos , Factores de Riesgo , Artritis Infecciosa/cirugíaRESUMEN
PURPOSE: Short stems are increasingly used in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Digital templating is essential in determining the correct offset option and stem size in THA. However, the preoperative template sizes might be intraoperatively overruled. PATIENTS AND METHODS: We evaluated the effect of intraoperative overruling of the preoperatively templated offset option of a short curved stem on hip offset, leg length, implant positioning, and femoral canal fill index. The overruling was performed in case of intraoperative instability, telescoping, or both. A series of 1052 consecutive THAs with a cementless short curved stem and press-fit cup was retrospectively screened. One hundred patients with unilateral THA and a contralateral native and morphologically healthy hip as a reference met the inclusion criteria. Measurements were carried out on preoperative and 3 months anterior-posterior postoperative radiographs. Patients were divided according to the overruling by offset option or stem size. RESULTS: Hip offset was increased in all groups, but only with significant increase if an offset option + 1 was used intraoperatively (p = 0.025). LLD was restored without significance in all groups (p = 0.323; p = 0.157). CONCLUSION: Intraoperative overruling of the preoperative digital template in cementless short stem total hip arthroplasty results in an increase of hip offset compared to a contralateral healthy hip. However, the increase is marginal and clearly under 5 mm compared to the contralateral healthy hip.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Radiografía , Huesos/cirugía , Articulación de la Cadera/cirugíaRESUMEN
PURPOSE: Varus positioning of the femoral stem can affect the hip offset (HO). The critical trochanter angle (CTA) was introduced in 2019 as a novel geometric angle, to predict varus stem alignment in cementless straight stem THA. The aim of this study was to evaluate the applicability of the CTA as a predictor for stem alignment in THA with a cementless neck resecting short stem. PATIENTS AND METHODS: In this retrospective study, 106 patients (index surgery 2014-2019) with unilateral THA and a morphologically healthy contralateral hip as a reference (Kellgren-Lawrence ≤ 1) were included. A cementless short stem with meta-diaphyseal fixation and press-fit cup was implanted in all cases. Stem alignment, CCD angle, CTA and offset reconstruction were measured on preoperative and 3 months postoperative AP radiographs of the pelvis. RESULTS: Preoperative lower CTA and lower CCD angle were positively correlated (r = 0.472; p < 0.001). Higher varus stem alignment is correlated with lower CTA (r = - 0.384; p < 0.001) and lower CCD angle (r = - 0.474; p < 0.001). A CTA of 23.1° or lower showed a sensitivity of 59.1% and a specificity of 87.1% (AUC: 0.733) and a CCD angle of 132.75° or lower a sensitivity of 68.2% and a specificity of 80.6% (AUC: 0.77) for a varus stem alignment > 3°. CONCLUSION: The CTA is also applicable in cementless THA with a neck resecting short stem to evaluate risk of intraoperative varus stem positioning. The CCD angle shows higher sensitivity with marginally lower specificity. Therefore, the CTA is not superior in predicting varus stem alignment in short-stem THA. LEVEL OF EVIDENCE: IV.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Radiografía , Diseño de PrótesisRESUMEN
PURPOSE: Minimally invasive approaches (MIS) in total hip arthroplasty (THA) show inconsistent findings regarding planning adherence in digital templating. The purpose of this study is to evaluate any difference in planning adherence between the direct anterior approach (DAA) and an anterolateral MIS approach (AL MIS) in cementless short stem THA. METHODS: A single surgeon series of 222 THAs in 208 patients with an uncemented short curved stem and a bi-hemispherical acetabular cup were screened for inclusion. A total of 118 THAs were implanted via the DAA and 72 THAs via the AL MIS were included. The planning adherence for the offset option, stem size and the acetabular cup were retrospectively evaluated. RESULTS: Planning adherence for cup size (perfect match: p = 0.763; ± 1 size: p = 0.124), offset option (0.125) and stem size (perfect match: p = 0.275; ± 1 size: p = 0.552) did not show any statistical significance. Preoperative diagnosis of avascular necrosis of the femoral head in AL MIS approach (OR 6.045; CI 1.153-31.696) or mild hip dysplasia in the general cohort poses (OR 11.789; CI 1.386-100.293) a significant risk for inadequate prediction of the offset option. CONCLUSION: digital templating for THA with an uncemented short curved stem and a bi-hemispherical acetabular cup show comparable results between a direct anterior approach and a minimally invasive anterolateral approach in supine position. Surgeons should be aware of a low planning adherence for this type of short stem in minimally invasive approaches. CONCLUSION: Digital templating for THA with an uncemented short curved stem and a bi-hemispherical acetabular cup show comparable results between a direct anterior approach and a minimally invasive anterolateral approach in supine position. Surgeons should be aware of a low planning adherence for this type of short stem in minimally invasive approaches.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación Congénita de la Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , AcetábuloRESUMEN
Background and Objectives: Noise exposure during total knee arthroplasty (TKA) has been demonstrated to exceed thresholds that are deemed as over-exposure by industry noise level standards. With orthopedic surgeons being at risk of suffering from Noise Induced Hearing Loss, the purpose of this pilot study was to evaluate the viability of the use of industry grade active noise cancelling headphones (ANCH) during TKA. Material and Methods: In this prospective pilot study, 10 TKA were performed. In five of these cases, surgeon, assistant, scrub nurse and anesthetist wore ANCH with automatic noise level dependent noise attenuation above 82 dB. A validated 14-item questionnaire was used after each case to evaluate the quality of communication, performance, teamwork and mental load. In seven cases a calibrated sound level meter was used to measure the operating theatre noise. Peak sound level (LApeak), A-weighted continuous sound level (LAeq) and A-weighted noise exposure averaged for an 8-h time-period (LEPd) were calculated. Results: There was no perceived benefit of ANCH for the surgeons (p = 0.648), assistants (p = 0.908) and scrub nurses (p = 0.251). There was an overall improvement observed by anesthetists (p = 0.001). A worse communication while wearing ANCH was reported by surgeons but not by the rest of the team. Average LApeak was 90.6 ± 3.2 dB(C), LAeq was 61.9 ± 1.0 dB(A) and LEPd was 53.2 ± 1.2 dB(A). Conclusions: Industry grade ANCH seem to provide no benefit for surgeons, assistants and scrub nurses during TKA, while anesthesiologists seem to benefit from the use of ANCH during TKA. Due to the limitations of this pilot study, further studies with larger study populations are necessary to adequately investigate the use of ANCH during TKA.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Cirujanos , Humanos , Proyectos Piloto , Estudios Prospectivos , RuidoRESUMEN
BACKGROUND: The Oxford Knee Score (OKS) has been designed for patients with knee osteoarthritis and has a widespread use. It has 12 questions, with each question having the same weight for the overall score. Some authors have observed a significant ceiling effect, especially when distinguishing slight postoperative differences. We hypothesized that each questions' weight will depend significantly on the patient's sociodemographic data and lifestyle. METHODS: In this international multicentric prospective study, we included patients attending a specialist outpatient knee clinic. Each patient filled out 3 questionnaires: (a) demographic data and data pertaining to the OKS, (b) the standard OKS, and (c) the patient gave a mark on the weight of the importance of each question, using a 5-point Likert scale (G OKS). Linear regression models were used for the analysis. RESULTS: In total 203 patients (106 female and 97 male) with a mean age of 64.5 (±12.7) years and a mean body mass index (BMI) of 29.34 (±5.45) kg/m2 were included. The most important questions for the patients were the questions for pain, washing, night pain, stability, and walking stairs with a median of 5. In the regression models, age, gender, and driving ability were the most important factors for the weight of each of the question. CONCLUSION: The questions in the OKS differ significantly in weight for each patient, based on sociodemographic data, such as age, self-use of a car, and employment. With these differences, the Oxford Knee Score might be limited as an outcome measure. Adjustment of the OKS that incorporates the demographic differences into the final score might be useful if the ceiling effect is to be mitigated. LEVEL OF EVIDENCE: Level II prospective prognostic study.
Asunto(s)
Empleo , Osteoartritis de la Rodilla , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Articulación de la Rodilla , Osteoartritis de la Rodilla/cirugía , DolorRESUMEN
BACKGROUND: Periprosthetic femoral fractures (PFFs) represent a major cause for surgical revision after hip arthroplasty with detrimental consequences for patients. The Vancouver classification has been traditionally used since its introduction in 1995. The Unified Classification System (UCS) was described in 2014, to widen the spectrum by aiming for a more comprehensive approach. The UCS also aimed to replace the Vancouver classification by expanding the idea of the Vancouver classification to the whole musculoskeletal apparatus. After introduction of the UCS, the question was raised, whether the UCS found its place in the field of analysing PFFs. Therefore, this systematic review was performed to investigate, the use of the UCS compared to the established Vancouver classification. METHODS: Medline was searched for reports published between 1 January 2016 and 31 November 2020, without language restriction. Included were original articles, irrespective of the level of evidence and case reports reporting on a PFF and using either the Vancouver or the UCS to classify the fractures. Excluded were reviews and systematic reviews. RESULTS: One hundred forty-six studies were included in the analysis. UCS has not been used in a single registry study, giving a pooled cohort size of 3299 patients, compared to 59,178 patients in studies using the Vancouver classification. Since 2016, one study using UCS was published in a top journal, compared to 37 studies using the Vancouver classification (p=0.29). During the study period, the number of yearly publications remained stagnant (p=0.899). CONCLUSIONS: Despite valuable improvement and expansion of the latter UCS, to date, the Vancouver system clearly leads the field of classifying PFFs in the sense of the common use.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/etiología , Fémur/cirugía , Humanos , Fracturas Periprotésicas/diagnóstico , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Estudios RetrospectivosRESUMEN
PURPOSE: Indications for unicompartmental knee arthroplasty (UKA) are controversial. Studies based solely on radiographic criteria suggest up to 49% of patients with knee osteoarthritis (OA) are suitable for UKA. In contrast, the 'Appropriate use criteria' (AUC), developed by the AAOS, apply clinical and radiographic criteria to guide surgical treatment of knee OA. The aim of this study was to analyze patient suitability for TKA, UKA and osteotomy using both radiographic criteria and AUC in a cohort of 300 consecutive knee OA patients. METHODS: Included were consecutive patients with clinical and radiographic signs of knee OA referred to a specialist clinic. Collected were demographic data, radiographic wear patterns and clinical findings that were analyzed using the AUC. A comparison of the radiographic wear patterns with the treatment suggested by the AUC as well as the Surgeon Treatment Decision was performed. RESULTS: There were 397 knees in 300 patients available for analysis. Median age was 68 [IQR 15], BMI 30 [6] with 55% females. Excellent consistency for both the radiographic criteria and the AUC criteria was found. Based on radiological criteria, 41% of knees were suitable for UKA. However, when using the AUC criteria, UKA was the appropriate treatment in only 13.3% of knees. In 19.1% of knees, no surgical treatment was appropriate at the visit, based on the collected data. CONCLUSION: Application of isolated radiologic criteria in patients with knee OA results in a UKA candidacy is misleadingly high. AUC that are based on both radiological and clinical criteria suggest UKA is appropriate in less than 15% of patients. LEVEL OF EVIDENCE: III retrospective study.
Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Anciano , Femenino , Humanos , Articulación de la Rodilla , Masculino , Osteotomía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
PURPOSE: Short stems are increasingly used in in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Short stems can be inserted in a more varus position compared to conventional straight stems. This poses the risk of final varus misplacement of the femoral component, which is not intended in all femoral short stems. METHODS: We wanted to evaluate the effect of a high varus stem positioning in MIS THA on hip offset, leg length and femoral canal fill index. A series of 1052 consecutive THAs with a singular cementless femoral short stem and press-fit cup was retrospectively screened for inclusion. One hundred six patients with unilateral THA and a contralateral healthy hip met the inclusion criteria. Measurements were carried out on preoperative and 3 months anterior-posterior postoperative radiographs. Patients were divided into Group A (varus stem alignment ≤ 3°) and Group B (varus stem alignment > 3°). RESULTS: Hip offset (HO) increased significantly in Group B by 4 mm (p = 0.013). No influence on leg length difference was detected in both groups. Preoperative CCD angle was significantly lower in Group B (p < 0.001). Canal Fill Indices (CFI) were significantly lower in Group B (CFI I: p < 0.001; CFI II p = 0.003; CF III p = 0.002). CONCLUSION: High varus stem alignment > 3° leads to a statistically significant but minor increase in HO and poses the risk of stem undersizing. A preoperatively low genuine CCD angle pose a risk for varus stem positioning.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Pierna , Diferencia de Longitud de las Piernas/etiología , Diferencia de Longitud de las Piernas/cirugía , Estudios RetrospectivosRESUMEN
PURPOSE: Digital templating shows reliable accuracy for straight stem systems. In recent years, the implantation of short stems through minimally invasive approaches has gained more popularity. Minimally invasive approaches (MIS) show the risk of undersizing femoral components. Therefore, we questioned the planning adherence for a curved short stem and a bi-hemispherical acetabular cup implanted through an anterolateral MIS approach. METHODS: A consecutive series of 964 hips (index surgery between 2014 and 2019) with Fitmore® curved short stem and Allofit/-S® acetabular cup (both ZimmerBiomet Inc, Warsaw, IN) were included. Preoperative digital templating was conducted anterior-posterior (AP) digital radiographs of the hip using mediCAD® version 5.1 (Hectec GmbH, Altdorf, Germany). The templates of acetabular and femoral components (offset option and stem size) were retrospectively evaluated for general adherence, and according to sex, BMI and planner's experience. RESULTS: Planning adherence for the exact offset option was 70.6 and 21.6% for exact offset option and stem size. Adherence for acetabular cup ± 1 size was 74.8%. A significant difference between male and female patients for the offset option could be found (p = 0.03, z = -2983). In 22.5% of male patients, an offset option one size higher and in 12.3% of female patients an offset option one size smaller than templated was used intraoperatively CONCLUSION: Digital templating for the Fitmore® stem in cementless THA with a minimally invasive anterolateral approach shows comparable planning adherence to the existing literature for this cementless short stem. However, a lower planning adherence was detected compared to conventional straight stem systems. In male patients, the femoral offset is frequently undersized and in female patients frequently oversized compared to the preoperative plan. Surgeons should be aware of this difficulty in digital templating for Fitmore® hip stem.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Femenino , Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Masculino , Estudios Retrospectivos , Factores SexualesRESUMEN
PURPOSE: Minimally invasive surgery using short stems in total hip arthroplasty gained more popularity. The differences in change of hip offset and implant positioning in minimally invasive approaches are not fully known. Therefore, this study was conducted to evaluate the difference in reconstruction of hip offset and implant positioning in direct anterior approach (DAA) and minimally invasive anterolateral approach (AL MIS). METHODS: A single surgeon series of 117 hips (117 patients; mean age 65.54 years ± 11.47; index surgery 2014-2018) were included and allocated into two groups: group A (DAA) with 70 hips and Group B (AL MIS) with 47 patients operated. In both groups the same type of cementless curved short hip stem and press fit cup was used. RESULTS: Both groups showed an equal statistically significant increase of femoral (p < 0.001) and decrease of acetabular offset (p < 0.001). Between both groups no statistically significant difference in offset reconstruction, leg length difference or implant positioning could be found. Leg length increased in both groups significantly and leg length discrepancy showed no difference (group A: - 0.06 mm; group B: 1.11 mm; p < 0.001). A comparable number of cups were positioned outside the target zone regarding cup anteversion. CONCLUSION: The usage of a curved short stem shows an equal reconstruction of femoro-acetabular offset, leg length and implant positioning in both MIS approaches. The results of this study show comparable results to the existing literature regarding change of offset and restoration of leg length. Malposition of the acetabular component regarding anteversion poses a risk.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/cirugía , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Diferencia de Longitud de las Piernas/cirugíaRESUMEN
Background and Objectives: Due to inferior survival rates compared to hip and knee arthroplasty, total ankle arthroplasty (TAA) was previously mainly recommended for older and less active patients. However, given the encouraging survival rates and clinical outcomes of modern generations of TAA, some authors have also advocated TAA in young patients. Thus, the aim of this study was to evaluate age related reoperation, revision and survival rates of third-generation mobile-bearing TAAs. Materials andMethods: In this retrospective study, 224 consecutive TAA patients with a minimum follow up (FU) of 2 years were analyzed. Patients were retrospectively assigned to two study groups (Group A: age < 50 years; Group B: age ≥ 50 years). Revision was defined as secondary surgery with prothesis component removal, while reoperation was defined as a non-revisional secondary surgery involving the ankle. Results: After a mean FU of 7.1 ± 3.2 years, the reoperation rate (Group A: 22.2%; Group B: 5.3%; p = 0.003) and revision rate (Group A: 36.1%; Group B: 13.8%; p = 0.003) were higher within Group A. An age of under 50 years at time of surgery was associated with higher reoperation (odds ratio (OR): 6.54 (95% CI: 1.96-21.8); p = 0.002) and revision rates (OR: 3.13 (95% CI: 1.22-8.04); p = 0.018). Overall, lower patient age was associated with higher reoperation (p = 0.009) and revision rates (p = 0.001). Conclusions: The ideal indication for TAA remains controversial, especially regarding patient age. The findings of this study show high reoperation and revision rates in patients aged under 50 years at time of surgery. Therefore, the outcomes of this study suggest that the indication for TAA in young patients should be considered very carefully and that the association between low patient age and high reoperation rate should be disclosed to all eligible patients.
Asunto(s)
Tobillo , Artroplastia de Reemplazo de Tobillo , Anciano , Articulación del Tobillo , Artroplastia de Reemplazo de Tobillo/efectos adversos , Humanos , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
PURPOSE: Obesity is associated with increased risk for surgical complications in total hip arthroplasty (THA). The impact of obesity on short-term complication in minimally invasive (MIS) anterolateral approach is not well known. Therefore, this study was conducted to evaluate the early complications within the first 90 days after THA using a MIS anterolateral approach with a short-curved stem stratified by Body Mass Index (BMI). PATIENTS AND METHODS: A single centre consecutive series of 1052 hips in 982 patients (index surgery 2014-2019) with a short-curved stem and press fit cup implanted using a MIS anterolateral approach in supine position were screened for inclusion. Inclusion criteria were defined as end-stage primary osteoarthritis of the hip. Eventually, 878 implantations in 808 patients were included and stratified by body mass index (BMI). Peri-operative complications, within the first 90 days after surgery, were retrospectively evaluated. RESULTS: Severely obese patients (BMI ≥ 35 kg/m2) and morbidly obese patients (BMI ≥ 40 kg/m2) demonstrated a significantly increased operation time (p < 0.001) and a higher risk for general surgical complications (p = 0.015) (odds ratio (OR) = 4.365; OR = 4.985), periprosthetic joint infection (PJI) (p = 0.001) (OR = 21.687; OR = 57.653), and revision (OR = 8.793; OR = 20.708). CONCLUSION: The risk for early PJI and overall surgical complications in MIS anterolateral approach is significantly increased in severely and morbidly obese patients. This leads to a significantly higher risk for revision surgery after index surgery within the first 90 days. A BMI above 35 kg/m2 is the clear threshold for increased risk of PJI in MIS anterolateral THA with a short curved stem. As the surgical complications are comparable to other approaches, MIS anterolateral short stem THA is also feasible with increasing BMI.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Obesidad Mórbida , Complicaciones Posoperatorias/epidemiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Obesidad Mórbida/complicaciones , Reoperación , Estudios Retrospectivos , Factores de RiesgoRESUMEN
Background and objectives: Based on the preparation of 20 formalin-fixed anatomical cadavers, the feasibility of the anterior, minimally invasive approach to the hip joint was investigated in each side of the body. The hypothesis of the study was that the Lateral Femoral Cutaneous Nerve can be spared under the use of this approach. Materials and Methods: The anterior approach to the hip was performed via an incision of 8 cm. The position of the nerve was noticed in relation to the skin incision, and the distance was measured in millimeters. The nerves main, gluteal and femoral trunk were distinguished and investigated for injury. Results: No injury of the main trunk was noticed. The average distance of the main trunk to the skin incision was 14.9 and 15.05 mm in the medial direction, respectively (p < 0.001). Injury of the gluteal branch has to be considered at an overall rate of 40%. Conclusions: The anterior, minimally invasive approach to the hip joint can be performed without injury of the Lateral Femoral Cutaneous Nerve.