Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Genomics ; 17: 486, 2016 07 09.
Artículo en Inglés | MEDLINE | ID: mdl-27393338

RESUMEN

BACKGROUND: The ability to capture and sequence large contiguous DNA fragments represents a significant advancement towards the comprehensive characterization of complex genomic regions. While emerging sequencing platforms are capable of producing several kilobases-long reads, the fragment sizes generated by current DNA target enrichment technologies remain a limiting factor, producing DNA fragments generally shorter than 1 kbp. The DNA enrichment methodology described herein, Region-Specific Extraction (RSE), produces DNA segments in excess of 20 kbp in length. Coupling this enrichment method to appropriate sequencing platforms will significantly enhance the ability to generate complete and accurate sequence characterization of any genomic region without the need for reference-based assembly. RESULTS: RSE is a long-range DNA target capture methodology that relies on the specific hybridization of short (20-25 base) oligonucleotide primers to selected sequence motifs within the DNA target region. These capture primers are then enzymatically extended on the 3'-end, incorporating biotinylated nucleotides into the DNA. Streptavidin-coated beads are subsequently used to pull-down the original, long DNA template molecules via the newly synthesized, biotinylated DNA that is bound to them. We demonstrate the accuracy, simplicity and utility of the RSE method by capturing and sequencing a 4 Mbp stretch of the major histocompatibility complex (MHC). Our results show an average depth of coverage of 164X for the entire MHC. This depth of coverage contributes significantly to a 99.94 % total coverage of the targeted region and to an accuracy that is over 99.99 %. CONCLUSIONS: RSE represents a cost-effective target enrichment method capable of producing sequencing templates in excess of 20 kbp in length. The utility of our method has been proven to generate superior coverage across the MHC as compared to other commercially available methodologies, with the added advantage of producing longer sequencing templates amenable to DNA sequencing on recently developed platforms. Although our demonstration of the method does not utilize these DNA sequencing platforms directly, our results indicate that the capture of long DNA fragments produce superior coverage of the targeted region.


Asunto(s)
Variación Genética , Genoma Humano , Genómica/métodos , Secuenciación de Nucleótidos de Alto Rendimiento , Hibridación Genómica Comparativa/métodos , Cartilla de ADN , Bases de Datos Genéticas , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Complejo Mayor de Histocompatibilidad/genética , Hibridación de Ácido Nucleico , Reacción en Cadena en Tiempo Real de la Polimerasa , Análisis de Secuencia de ADN
2.
Hum Immunol ; 78(10): 642-648, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28732721

RESUMEN

BACKGROUND: A simplified protocol for HLA-typing -by NGS, developed for use with the Illumina MiSeq, was performed by technologists with varying NGS experience to assess accuracy and reproducibility. METHODS: Technologists from six laboratories typed the same 16 samples at HLA-A, B, C, DRB1, and DQB1. The protocol includes long range PCR, library preparation, and paired-end 250bp sequencing. Two indexing strategies were employed: locus-specific indexing whereby each locus was tagged uniquely and sample-specific indexing whereby all 5 loci for a sample were pooled prior to library preparation. Sequence analysis was performed with two software packages, Target HLA (Omixon) and NGSengine (GenDx). RESULTS: The average number of sequence reads per library was 387,813; however, analysis was limited to 40,000 reads for locus-indexed libraries and 200,000 reads for sample-indexed libraries resulting in an average depth of coverage of 1444 reads per locus. Sufficient reads for genotype analysis were obtained for 98.4% of libraries. Genotype accuracy was >97% in pooled amplicons and >99% in individual amplicons by both software analysis. Inter-laboratory reproducibility was 99.7% and only cause of discordance was cross-contamination of a single amplicon. CONCLUSIONS: This NGS HLA-typing protocol is simple, reproducible, scalable, highly accurate and amenable to clinical testing.


Asunto(s)
Genotipo , Antígenos HLA/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Prueba de Histocompatibilidad/métodos , Alelos , Estudios de Factibilidad , Biblioteca de Genes , Técnicas de Genotipaje , Interoperabilidad de la Información en Salud , Humanos , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA