Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Phys Rev Lett ; 120(15): 155001, 2018 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-29756884

RESUMEN

We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic radiation into the continuous-wave regime of a cyclotron maser formed in magnetically confined nonequilibrium plasma. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulting from electron cyclotron plasma heating in a MHD-stable minimum-B open magnetic trap.

2.
Biofizika ; 59(3): 545-51, 2014.
Artículo en Ruso | MEDLINE | ID: mdl-25715599

RESUMEN

Non-invasive deep brain acoustic thermometry is carried out for two patients at Burdenko Neurosurgery Institute. This method is based on the measurements of the own thermal acoustic radiation of the investigated object. These two patients have got the brain injury. Some of their skull bones are absent. Infrared thermometry was also used to measure the surface temperature of the forehead skin. On the basis of the experimental data the temperatures deep within the brain were reconstructed. The values for the two patients are equal to 37.3 0.7 and 37.0 0.3 degrees C.


Asunto(s)
Acústica/instrumentación , Lesiones Encefálicas/fisiopatología , Temperatura Cutánea , Termometría , Adulto , Lesiones Encefálicas/patología , Femenino , Humanos , Masculino , Termometría/instrumentación , Termometría/métodos
3.
Rev Sci Instrum ; 79(2 Pt 2): 02B304, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315170

RESUMEN

A high current, multi charged, metal ion source using electron heating of vacuum arc plasma by high power gyrotron radiation has been developed. The plasma is confined in a simple mirror trap with peak magnetic field in the plug up to 2.5 T, mirror ratio of 3-5, and length variable from 15 to 20 cm. Plasma formed by a cathodic vacuum arc is injected into the trap either (i) axially using a compact vacuum arc plasma gun located on axis outside the mirror trap region or (ii) radially using four plasma guns surrounding the trap at midplane. Microwave heating of the mirror-confined, vacuum arc plasma is accomplished by gyrotron microwave radiation of frequency 75 GHz, power up to 200 kW, and pulse duration up to 150 micros, leading to additional stripping of metal ions by electron impact. Pulsed beams of platinum ions with charge state up to 10+, a mean charge state over 6+, and total (all charge states) beam current of a few hundred milliamperes have been formed.

4.
Aviakosm Ekolog Med ; 33(3): 34-7, 1999.
Artículo en Ruso | MEDLINE | ID: mdl-10485030

RESUMEN

Presented are results of gas bubbles monitoring in decompressed humans with the use of an ultrasonic pulse-Doppler locator (PDL). Unlike the classic Doppler bubbles detectors with continuous US emission, PDL is adjusted for reception of echo from a chosen volume of the right ventricle cavity; thus, the clutter due to cardiac beats and human locomotion is successfully rejected. During simulation of Russian EVAs, venous gas bubbles were detected in 3 out of 5 experiments with test-subjects clothed in everyday wear and in 2 out of 3 experiments with suited test-subjects.


Asunto(s)
Enfermedad de Descompresión/diagnóstico por imagen , Actividad Extravehicular/fisiología , Trajes Espaciales , Ultrasonografía Doppler de Pulso/métodos , Adulto , Descompresión/estadística & datos numéricos , Enfermedad de Descompresión/sangre , Estudios de Evaluación como Asunto , Humanos , Masculino , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/estadística & datos numéricos , Federación de Rusia , Simulación del Espacio/instrumentación , Simulación del Espacio/métodos , Simulación del Espacio/estadística & datos numéricos , Factores de Tiempo , Ultrasonografía Doppler de Pulso/instrumentación , Ultrasonografía Doppler de Pulso/estadística & datos numéricos , Vacio
5.
Rev Sci Instrum ; 83(2): 02A325, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380172

RESUMEN

We suggest a Penning-type discharge as a trigger discharge for fast development of pulsed electron cyclotron resonance plasma. The Penning-type discharge glows at a low pressure as needed. Gyrotron radiation (75 GHz, 200 kW, 1 ms) was used for plasma heating. Fully striped helium ions were demonstrated, average charge of ions in the plasma was ≈ 2. Experiment and calculations show that high charge states of heavier gases require lower initial pressure and longer development time. Only moderate charge states are achievable in this pulsed scheme.

6.
Rev Sci Instrum ; 83(2): 02B504, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380303

RESUMEN

Experimental investigation is undertaken to study formation of electron energy distribution function (EEDF) at the initial stage of electron cyclotron resonance (ECR) discharge inside magnetic mirror trap. In experiment, where discharge was initiated by high power radiation of gyrotron operated in the mm-wavelength range, electrons were revealed to leave the trap having EEDF be quite different from Maxwellian one. Specifically, the EEDF was found to decrease slowly with energy up to 400-500 keV and drops abruptly further. The possible physical mechanisms are discussed to explain losses of high energy electrons from the trap and a limitation of their energy.

7.
Rev Sci Instrum ; 83(2): 02A309, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380156

RESUMEN

A method for generating high charge state heavy metal ion beams based on high power microwave heating of vacuum arc plasma confined in a magnetic trap under electron cyclotron resonance conditions has been developed. A feature of the work described here is the use of a cusp magnetic field with inherent "minimum-B" structure as the confinement geometry, as opposed to a simple mirror device as we have reported on previously. The cusp configuration has been successfully used for microwave heating of gas discharge plasma and extraction from the plasma of highly charged, high current, gaseous ion beams. Now we use the trap for heavy metal ion beam generation. Two different approaches were used for injecting the vacuum arc metal plasma into the trap--axial injection from a miniature arc source located on-axis near the microwave window, and radial injection from sources mounted radially at the midplane of the trap. Here, we describe preliminary results of heating vacuum arc plasma in a cusp magnetic trap by pulsed (400 µs) high power (up to 100 kW) microwave radiation at 37.5 GHz for the generation of highly charged heavy metal ion beams.

8.
Rev Sci Instrum ; 82(6): 063503, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21721687

RESUMEN

The results of first experiments on the investigation of plasma of electron cyclotron resonance (ECR) discharge, sustained by CW radiation of technological gyrotron with frequency 24 GHz are considered. The parameters of nitrogen plasma of ECR discharge in magnetic field up to 1 T were investigated by Langmuir probe in the pressure range 10(-4)-10(-2) mbar under different values of microwave power. Depending on gas pressure and power of microwave radiation, the typical temperature and density of electrons could attain values of 1-5 eV and 10(11)-10(12) cm(-3), respectively. The prospects for using of ECR discharge for plasma chemical decomposition of silicon tetrafluoride (SiF(4)) have been experimentally demonstrated. Plasma was created from SiF(4) and hydrogen (H(2)) gas mixture and heated by microwave radiation in ECR conditions. Using the method of mass-spectrometry analysis of the gas at the outlet from the reactor and the weighting method, the content of the resultants of SiF(4) decomposition as a function of process parameters was investigated. It was shown that SiF(4) decomposition degree strongly depends on the microwave power, gas pressure in the reactor, gas flow rates, and can attain the value of 50%. The possible applications of PECVD method based on ECR discharge for production of isotopically pure elements with high deposition rate are discussed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA