Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 24(6): e13919, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37278646

RESUMEN

To evaluate the image quality, dosimetric properties, setup reproducibility, and planar cine motion detection of a high-resolution brain coil and integrated stereotactic brain immobilization system that constitute a new brain treatment package (BTP) on a low-field magnetic resonance imaging (MRI) linear accelerator (MR-linac). Image quality of the high-resolution brain coil was evaluated with the 17 cm diameter spherical phantom and the American College of Radiology (ACR) Large MRI Phantom. Patient imaging studies approved by the institutional review board (IRB) assisted in selecting image acquisition parameters. Radiographic and dosimetric evaluation of the high-resolution brain coil and the associated immobilization devices was performed using dose calculations and ion chamber measurements. End-to-end testing was performed simulating a cranial lesion in a phantom. Inter-fraction setup variability and motion detection tests were evaluated on four healthy volunteers. Inter-fraction variability was assessed based on three repeat setups for each volunteer. Motion detection was evaluated using three-plane (axial, coronal, and sagittal) MR-cine imaging sessions, where volunteers were asked to perform a set of specific motions. The images were post-processed and evaluated using an in-house program. Contrast resolution of the high-resolution brain coil is superior to the head/neck and torso coils. The BTP receiver coils have an average HU value of 525 HU. The most significant radiation attenuation (3.14%) of the BTP, occurs through the lateral portion of the overlay board where the high-precision lateral-profile mask clips attach to the overlay. The greatest inter-fraction setup variability occurred in the pitch (average 1.08 degree) and translationally in the superior/inferior direction (average 4.88 mm). Three plane cine imaging with the BTP was able to detect large and small motions. Small voluntary motions, sub-millimeter in magnitude (maximum 0.9 mm), from motion of external limbs were detected. Imaging tests, inter-fraction setup variability, attenuation, and end-to-end measurements were quantified and performed for the BTP. Results demonstrate better contrast resolution and low contrast detectability that allows for better visualization of soft tissue anatomical changes relative to head/neck and torso coil systems.


Asunto(s)
Neoplasias Encefálicas , Humanos , Reproducibilidad de los Resultados , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Encéfalo , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
2.
Ecotoxicol Environ Saf ; 211: 111952, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33513523

RESUMEN

The accumulation of cadmium (Cd) in Oryza sativa L., the world's most significant staple crop, is a health threat to millions of people. The objective of this study was to evaluate the effectiveness of commercially available biofertilizers (with high (BF2) and low organic matter (OM) content (BF1)) on Cd accumulation in two types of soils and to determine the bacterial community responses by high-throughput sequencing. The study was conducted in the form of pot experiment in greenhouse in 2018. Four treatments were set: BF1, BF2, organic fertilizer (OF), and control (CK) and the amendments were applied before the rice cultivation. The results showed that the addition of biofertilizers immobilized or mobilized Cd in soils, depending on the soil type and the OM content in biofertilizers. The exogenous OM in biofertilizers was the driving factor for the difference in pH and Cd accumulation in rice grains. The application of biofertilizers with high OM content was effective in reducing Cd accumulation in the rice grains (19.7% lower than CK) by significantly increasing soil pH (from 6.02 to 6.67) in acid silt loam soil (TZ). The consumption of acid fermentation products by soil chemoorganotrophs and the complexation of organic anions in the biofertilizer treatment tended to buffer the pH drop in the drainage and decrease the Cd availability. However, in the weak acid silty clay loam soil (SX), the addition of biofertilizer with high OM significantly increased Cd accumulation in rice grains (21.9% higher than CK), probably owing to the release of acid substances, resulting from the significant increase of the predominant bacteria Chloroflexi. The addition of biofertilizer with low OM content did not significantly change Cd accumulation in rice grains or affect the soil microbial structures in both soils. In conclusion, the effects of biofertilizer on rice Cd accumulation were related to the OM content and soil bacterial community. Biofertilizers with high organic matter may not be suitable for amendments in the paddy soils with high clay content to reduce Cd accumulation in rice grains.


Asunto(s)
Cadmio/metabolismo , Oryza/metabolismo , Contaminantes del Suelo/metabolismo , Bacterias , Cadmio/análisis , Fertilizantes/análisis , Oryza/efectos de los fármacos , Estructuras de las Plantas/química , Suelo/química , Contaminantes del Suelo/análisis
3.
J Appl Clin Med Phys ; 22(9): 37-48, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34378308

RESUMEN

PURPOSE: We performed quantitative analysis of differences in deformable image registration (DIR) and deformable dose accumulation (DDA) computed on CBCT datasets reconstructed using the standard (Feldkamp-Davis-Kress: FDK_CBCT) and a novel iterative (iterative_CBCT) CBCT reconstruction algorithms. METHODS: Both FDK_CBCT and iterative_CBCT images were reconstructed for 323 fractions of treatment for 10 prostate cancer patients. Planning CT images were deformably registered to each CBCT image data set. After daily dose distributions were computed, they were mapped to planning CT to obtain deformed doses. Dosimetric and image registration results based CBCT images reconstructed by two algorithms were compared at three levels: (A) voxel doses over entire dose calculation volume, (B) clinical constraint results on targets and sensitive structures, and (C) contours propagated to CBCT images using DIR results based on three algorithms (SmartAdapt, Velocity, and Elastix) were compared with manually delineated contours as ground truth. RESULTS: (A) Average daily dose differences and average normalized DDA differences between FDK_CBCT and iterative_CBCT were ≤1 cGy. Maximum daily point dose differences increased from 0.22 ± 0.06 Gy (before the deformable dose mapping operation) to 1.33 ± 0.38 Gy after the deformable dose mapping. Maximum differences of normalized DDA per fraction were up to 0.80 Gy (0.42 ± 0.19 Gy). (B) Differences in target minimum doses were up to 8.31 Gy (-0.62 ± 4.60 Gy) and differences in critical structure doses were 0.70 ± 1.49 Gy. (C) For mapped prostate contours based on iterative_CBCT (relative to standard FDK_CBCT), dice similarity coefficient increased by 0.10 ± 0.09 (p < 0.0001), mass center distances decreased by 2.5 ± 3.0 mm (p < 0.00005), and Hausdorff distances decreased by 3.3 ± 4.4 mm (p < 0.00015). CONCLUSIONS: The new iterative CBCT reconstruction algorithm leads to different mapped volumes of interest, deformed and cumulative doses than results based on conventional FDK_CBCT.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Algoritmos , Tomografía Computarizada de Haz Cónico , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Radiometría , Planificación de la Radioterapia Asistida por Computador
4.
J Appl Clin Med Phys ; 21(11): 288-294, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33044040

RESUMEN

PURPOSE: To investigate the differences between internal target volumes (ITVs) contoured on the simulation 4DCT and daily 4DCBCT images for lung cancer patients treated with stereotactic body radiotherapy (SBRT) and determine the dose delivered on 4D planning technique. METHODS: For nine patients, 4DCBCTs were acquired before each fraction to assess tumor motion. An ITV was contoured on each phase of the 4DCBCT and a union of the 10 ITVs was used to create a composite ITV. Another ITV was drawn on the average 3DCBCT (avgCBCT) to compare with current clinical practice. The Dice coefficient, Hausdorff distance, and center of mass (COM) were averaged over four fractions to compare the ITVs contoured on the 4DCT, avgCBCT, and 4DCBCT for each patient. Planning was done on the average CT, and using the online registration, plans were calculated on each phase of the 4DCBCT and on the avgCBCT. Plan dose calculations were tested by measuring ion chamber dose in the CIRS lung phantom. RESULTS: The Dice coefficients were similar for all three comparisons: avgCBCT-to-4DCBCT (0.7 ± 0.1), 4DCT-to-avgCBCT (0.7 ± 0.1), and 4DCT-to-4DCBCT (0.7 ± 0.1); while the mean COM differences were also comparable (2.6 ± 2.2mm, 2.3 ± 1.4mm, and 3.1 ± 1.1mm, respectively). The Hausdorff distances for the comparisons with 4DCBCT (8.2 ± 2.9mm and 8.1 ± 3.2mm) were larger than the comparison without (6.5 ± 2.5mm). The differences in ITV D95% between the treatment plan and avgCBCT calculations were 4.3 ± 3.0% and -0.5 ± 4.6%, between treatment plan and 4DCBCT plans, respectively, while the ITV V100% coverages were 99.0 ± 1.9% and 93.1 ± 8.0% for avgCBCT and 4DCBCT, respectively. CONCLUSION: There is great potential for 4DCBCT to evaluate the extent of tumor motion before treatment, but image quality challenges the clinician to consistently delineate lung target volumes.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Tomografía Computarizada de Haz Cónico Espiral , Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Humanos , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Planificación de la Radioterapia Asistida por Computador , Respiración
5.
J Appl Clin Med Phys ; 19(6): 177-184, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30294838

RESUMEN

PURPOSE: We explore the optimal cone-beam CT (CBCT) acquisition parameters to improve CBCT image quality to enhance intracranial stereotactic radiosurgery (SRS) localization and also assess the imaging dose levels associated with each imaging protocol. METHODS: Twenty-six CBCT acquisition protocols were generated on an Edge® linear accelerator (Varian Medical Systems, Palo Alto, CA) with different x-ray tube current and potential settings, gantry rotation trajectories, and gantry rotation speeds. To assess image quality, images of the Catphan 504 phantom were analyzed to evaluate the following image quality metrics: uniformity, HU constancy, spatial resolution, low contrast detection, noise level, and contrast-to-noise ratio (CNR). To evaluate the imaging dose for each protocol, the cone-beam dose index (CBDI) was measured. To validate the phantom results, further analysis was performed with an anthropomorphic head phantom as well as image data acquired for a clinical SRS patient. RESULTS: The Catphan data indicates that adjusting acquisition parameters had direct effects on the image noise level, low contrast detection, and CNR, but had minimal effects on uniformity, HU constancy, and spatial resolution. The noise level was reduced from 34.5 ± 0.3 to 18.5 ± 0.2 HU with a four-fold reduction in gantry speed, and to 18.7 ± 0.2 HU with a four-fold increase in tube current. Overall, the noise level was found to be proportional to inverse square root of imaging dose, and imaging dose was proportional to the product of total tube current-time product and the cube of the x-ray potential. Analysis of the anthropomorphic head phantom data and clinical SRS imaging data also indicates that noise is reduced with imaging dose increase. CONCLUSIONS: Our results indicate that optimization of the imaging protocol, and thereby an increase in the imaging dose, is warranted for improved soft-tissue visualization for intracranial SRS.


Asunto(s)
Huesos/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Cabeza/diagnóstico por imagen , Fantasmas de Imagen , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de los Tejidos Blandos/cirugía , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Pronóstico , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Neoplasias de los Tejidos Blandos/diagnóstico por imagen
6.
J Appl Clin Med Phys ; 18(1): 157-163, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28291932

RESUMEN

PURPOSE: We have initiated a multi-institutional phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for Stage III-IVa laryngeal cancer. We conducted this pilot dosimetric study to confirm potential utility of online adaptive replanning to preserve treatment quality. METHODS: We evaluated ten cases: five patients enrolled onto the current trial and five patients enrolled onto a separate phase I SBRT trial for early-stage glottic larynx cancer. Baseline SBRT treatment plans were generated per protocol. Daily cone-beam CT (CBCT) or diagnostic CT images were acquired prior to each treatment fraction. Simulation CT images and target volumes were deformably registered to daily volumetric images, the original SBRT plan was copied to the deformed images and contours, delivered dose distributions were re-calculated on the deformed CT images. All of these were performed on a commercial treatment planning system. In-house software was developed to propagate the delivered dose distribution back to reference CT images using the deformation information exported from the treatment planning system. Dosimetric differences were evaluated via dose-volume histograms. RESULTS: We could evaluate dose within 10 minutes in all cases. Prescribed coverage to gross tumor volume (GTV) and clinical target volume (CTV) was uniformly preserved; however, intended prescription dose coverage of planning treatment volume (PTV) was lost in 53% of daily treatments (mean: 93.9%, range: 83.9-97.9%). Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. CONCLUSIONS: Although GTV and CTV SBRT dose coverage is preserved with in-room three-dimensional image guidance, PTV coverage can vary significantly from intended plans and dose to critical structures may exceed tolerances. Online adaptive treatment re-planning is potentially necessary and clinically applicable to fully preserve treatment quality. Confirmatory trial accrual and analysis remains ongoing.


Asunto(s)
Carcinoma de Células Escamosas/cirugía , Tomografía Computarizada de Haz Cónico/métodos , Neoplasias Laríngeas/cirugía , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/diagnóstico por imagen , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Neoplasias Laríngeas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Sistemas en Línea , Proyectos Piloto , Pronóstico , Estudios Prospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
7.
J Appl Clin Med Phys ; 16(4): 306-310, 2015 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-26218992

RESUMEN

Geometric or mechanical accuracy of kV and MV imaging systems of two Varian TrueBeam linacs have been monitored by two geomertirc calibration systems, Varian IsoCal geometric calibration system and home-developed gQA system. Results of both systems are cross-checked and the long-term geometric stabilities of linacs are evaluated. Two geometric calibration methodologies have been used to assess kV and MV imaging systems and their coincidence periodically on two TrueBeam linacs for about one year. Both systems analyze kV or MV projection images of special designed phantoms to retrieve geometric parameters of the imaging systems. The isocenters ­ laser isocenter and centers of rotations of kV imager and EPID ­ are then calculated, based on results of multiple projections from different angles. Long-term calibration results from both systems are compared for cross-checking. There are 24 sessions of side-by-side calibrations performed by both systems on two TrueBeam linacs. All the disagreements of isocenters between two calibrations systems are less than 1 mm with ± 0.1 mm SD. Most of the large disagreements occurred in vertical direction (AP direction), with an averaged disagreement of 0.45 mm. The average disagreements of isocenters are 0.09 mm in other directions. Additional to long-term calibration monitoring, for the accuracy test, special tests were performed by misaligning QA phantoms on purpose (5 mm away from setup isocenter in AP, SI, and lateral directions) to test the liability performance of both systems with the known deviations. The errors are within 0.5 mm. Both geometric calibration systems, IsoCal and gQA, are capable of detecting geometric deviations of kV and MV imaging systems of linacs. The long-term evaluation also shows that the deviations of geometric parameters and the geometric accuracies of both linacs are small and very consistent during the one-year study period.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Aceleradores de Partículas/normas , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/métodos , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Calibración , Humanos , Aceleradores de Partículas/instrumentación , Programas Informáticos
8.
J Appl Clin Med Phys ; 16(3): 5200, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103480

RESUMEN

In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, global image intensity discrepancies exist between DRRs and projections due to their different image orientations, scattering, and noises. This adversely affects comparison accuracy. A simple but efficient comparison algorithm is reported to match imperfectly matched projection images and DRRs. The kV projection images were matched with different DRRs in two steps. Preprocessing was performed in advance to generate two sets of DRRs. The tumors were removed from the planning 3D CT for a single phase of planning 4D CT images using planning contours of tumors. DRRs of background and DRRs of tumors were generated separately for every projection angle. The first step was to match projection images with DRRs of background signals. This method divided global images into a matrix of small tiles and similarities were evaluated by calculating normalized cross-correlation (NCC) between corresponding tiles on projections and DRRs. The tile configuration (tile locations) was automatically optimized to keep the tumor within a single projection tile that had a bad matching with the corresponding DRR tile. A pixel-based linear transformation was determined by linear interpolations of tile transformation results obtained during tile matching. The background DRRs were transformed to the projection image level and subtracted from it. The resulting subtracted image now contained only the tumor. The second step was to register DRRs of tumors to the subtracted image to locate the tumor. This method was successfully applied to kV fluoro images (about 1000 images) acquired on a Vero (BrainLAB) for dynamic tumor tracking on phantom studies. Radiation opaque markers were implanted and used as ground truth for tumor positions. Although other organs and bony structures introduced strong signals superimposed on tumors at some angles, this method accurately located tumors on every projection over 12 gantry angles. The maximum error was less than 2.2 mm, while the total average error was less than 0.9mm. This algorithm was capable of detecting tumors without markers, despite strong background signals.


Asunto(s)
Algoritmos , Artefactos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Técnica de Sustracción , Marcadores Fiduciales , Humanos , Aumento de la Imagen/métodos , Neoplasias Pulmonares/radioterapia , Radioterapia Guiada por Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Plant J ; 74(1): 86-97, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23289750

RESUMEN

Auxin plays a pivotal role in many facets of plant development. It acts by inducing the interaction between auxin-responsive [auxin (AUX)/indole-3-acetic acid (IAA)] proteins and the ubiquitin protein ligase SCF(TIR) to promote the degradation of the AUX/IAA proteins. Other cofactors and chaperones that participate in auxin signaling remain to be identified. Here, we characterized rice (Oryza sativa) plants with mutations in a cyclophilin gene (OsCYP2). cyp2 mutants showed defects in auxin responses and exhibited a variety of auxin-related growth defects in the root. In cyp2 mutants, lateral root initiation was blocked after nuclear migration but before the first anticlinal division of the pericycle cell. Yeast two-hybrid and in vitro pull-down results revealed an association between OsCYP2 and the co-chaperone Suppressor of G2 allele of skp1 (OsSGT1). Luciferase complementation imaging assays further supported this interaction. Similar to previous findings in an Arabidopsis thaliana SGT1 mutant (atsgt1b), degradation of AUX/IAA proteins was retarded in cyp2 mutants treated with exogenous 1-naphthylacetic acid. Our results suggest that OsCYP2 participates in auxin signal transduction by interacting with OsSGT1.


Asunto(s)
Ciclofilinas/metabolismo , Ácidos Indolacéticos/farmacología , Oryza/genética , Proteínas de Plantas/metabolismo , Raíces de Plantas/crecimiento & desarrollo , Clonación Molecular , Ciclofilinas/genética , Regulación de la Expresión Génica de las Plantas , Datos de Secuencia Molecular , Mutación , Oryza/crecimiento & desarrollo , Reguladores del Crecimiento de las Plantas/farmacología , Proteínas de Plantas/genética , Transducción de Señal , Técnicas del Sistema de Dos Híbridos
10.
Shanghai Kou Qiang Yi Xue ; 33(2): 211-218, 2024 Apr.
Artículo en Zh | MEDLINE | ID: mdl-39005102

RESUMEN

PURPOSE: To investigate the effects of different cortical bone thickness and jaw bone density at implant sites on intraoperative pain during implant surgery. METHODS: One hundred and eighty-seven patients(263 implant sites) who underwent implant placement surgery at the Fourth Affiliated Hospital of Nanchang University from August 2021 to August 2022 were selected to investigate the effects of different cortical bone thickness and jaw bone density HU values at implant sites on the anesthetic effect under local infiltration anesthesia with epinephrine in articaine. SPSS 26.0 software package was used for data analysis. RESULTS: The mean cortical bone thickness at the painful sites[(3.90±1.36) mm] was significantly greater than that at the non-painful sites [(2.24±0.66) mm], and the difference was statistically significant(P<0.05). The differences in cortical bone thickness in the mandibular anterior, premolar, and molar regions were statistically significant in the comparison of pain and non-pain sites. The mean HU value of bone density was (764.46±239.75) for the painful sites and (612.23±235.31) for the non-painful sites, with significant difference(P<0.05). The difference was not significant(P>0.05) when comparing the HU values of painful sites with non-painful sites in the mandibular anterior teeth and anterior molar region, while the difference was significant(P<0.05) when comparing the HU values of painful sites with non-painful sites in the mandibular molar region. CONCLUSIONS: Sites with large cortical bone thickness have a greater effect on blocking infiltrative anesthetic penetration and are more prone to intraoperative pain during implantation. In the mandibular anterior and premolar regions, the HU value of the implant sites had less effect on infiltrative anesthetic penetration, and the effect was greater in the mandibular molar region, and the implant sites with high HU values in the mandibular molar region were more likely to have intraoperative pain. When the cortical bone thickness in the planned implant site is greater than 3.9 mm and the mean bone density in the mandibular molar region is greater than 665 HU. If there is sufficient safe distance for hole operation, it is recommended to apply mandibular nerve block anesthesia combined with articaine infiltration anesthesia to avoid intraoperative pain and bad surgical experience for the patients.


Asunto(s)
Densidad Ósea , Hueso Cortical , Mandíbula , Humanos , Densidad Ósea/efectos de los fármacos , Mandíbula/cirugía , Mandíbula/anatomía & histología , Hueso Cortical/anatomía & histología , Implantes Dentales , Anestesia Local/métodos , Dolor/etiología , Carticaína/administración & dosificación
11.
Integr Zool ; 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39350496

RESUMEN

The Yarlung Tsangpo River on the Tibetan Plateau provides a unique natural environment for studying fish evolution and ecology. However, the genomes and genetic diversity of plateau fish species have been rarely reported. Schizopygopsis younghusbandi, a highly specialized Schizothoracine species and economically important fish inhabiting the Yarlung Tsangpo River, is threatened by overfishing and biological invasion. Herein, we generated a chromosome-level genome of S. younghusbandi and whole-genome resequencing data for 59 individuals from six locations of the river. The results showed that the divergence time between S. younghusbandi and other primitive Schizothoracine species was ∼4.2 Mya, coinciding with the major phase of the Neogene Tibetan uplift. The expanded gene families enriched in DNA integration and replication, ion binding and transport, energy storage, and metabolism likely contribute to the adaption of this species. The S. younghusbandi may have diverged from other highly specialized Schizothoracine species in the Zanda basin during the Pliocene epoch, which underwent major population reduction possibly due to the drastic climate change during the last glacial period. Population analysis indicated that the ancient population might have originated upstream before gradually adapting to evolve into the populations inhabiting the mid-stream and downstream regions of the Yarlung Tsangpo River. In conclusion, the chromosome-level genome and population diversity of S. younghusbandi provide valuable genetic resources for the evolution, ecology, and conservation studies of endemic fishes on the Tibetan Plateau.

12.
Physiol Plant ; 148(1): 133-45, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-22998725

RESUMEN

The aim of this study was to examine the role of brassinosteroids (BRs) in protecting the photosynthetic apparatus from cold-induced damage in cucumber (Cucumis sativus) plants. Recovery at both high light (HL) and low light (LL) after a cooling at 10/7°C induced irreversible inhibition of CO2 assimilation, photoinhibition at photosystem I (PSI) and inhibition of enzyme activities of Calvin cycle and ascorbate (AsA)-reduced glutathione (GSH) cycle, followed by accumulation of H2 O2 and malondialdehyde. However, cold-induced photoinhibition at PSII was fully recovered at LL but not at HL. Meanwhile, recovery at HL increased electron flux to O2 -dependent alternative pathway [Ja(O2 -dependent)]. Foliar application of 24-epibrassinolide (EBR) accelerated recovery from photoinhibition of PSII but not of PSI. EBR also significantly increased CO2 assimilation, activity of Calvin cycle enzymes and electron flux to carbon reduction [Je(PCR)], with a concomitant decrease in Ja(O2 -dependent); meanwhile EBR increased the activity of enzymes in AsA-GSH cycle and cellular redox states. However, the positive effect of EBR on plant recovery was observed only at HL, but not LL. These results indicate that BR accelerates the recovery of photosynthetic apparatus at HL by activation of enzymes in Calvin cycle and increasing the antioxidant capacity, which in turn mitigate the photooxidative stress and the inhibition of plant growth during the recovery.


Asunto(s)
Brasinoesteroides/metabolismo , Frío , Cucumis sativus/metabolismo , Homeostasis , Fotosíntesis , Estrés Fisiológico , Antioxidantes/metabolismo , Dióxido de Carbono/metabolismo , Cucumis sativus/crecimiento & desarrollo , Transporte de Electrón , Luz , Peroxidación de Lípido , Oxidación-Reducción
13.
J Chem Ecol ; 39(2): 232-42, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23385367

RESUMEN

Negative plant-soil feedbacks play an important role in soil sickness, which is one of the factors limiting the sustainable development of intensive agriculture. Various factors, such as the buildup of pests in the soil, disorder in physico-chemical soil properties, autotoxicity, and other unknown factors may contribute to soil sickness. A range of autotoxins have been identified, and these exhibit their allelopathic potential by influencing cell division, water and ion uptake, dark respiration, ATP synthesis, redox homeostasis, gene expression, and defense responses. Meanwhile, there are great interspecific and intraspecific differences in the uptake and accumulation of autotoxins, which contribute to the specific differences in growth in response to different autotoxins. Importantly, the autotoxins also influence soil microbes and vice versa, leading to an increased or decreased degree of soil sickness. In many cases, autotoxins may enhance soilborne diseases by predisposing the roots to infection by soilborne pathogens through a direct biochemical and physiological effect. Some approaches, such as screening for low autotoxic potential and disease-resistant genotypes, proper rotation and intercropping, proper soil and plant residue management, adoption of resistant plant species as rootstocks, introduction of beneficial microbes, physical removal of phytotoxins, and soil sterilization, are proposed. We discuss the challenges that we are facing and possible approaches to these.


Asunto(s)
Feromonas/metabolismo , Fenómenos Fisiológicos de las Plantas , Microbiología del Suelo , Suelo/química , Agricultura , Enfermedades de las Plantas/etiología , Enfermedades de las Plantas/microbiología , Plantas/metabolismo , Plantas/microbiología , Rizosfera
14.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 41(4): 478-482, 2023 Aug 01.
Artículo en Inglés, Zh | MEDLINE | ID: mdl-37474481

RESUMEN

Epidermoid cysts are generally benign neoplastic lesions, the etiology of which is unclear and is mainly related to epithelial cells left in the tissues during the embryonic period and traumatically implanted in the tissues. The most common intraosseous sites are the phalanges and the skull. Epidermoid cysts occurring in the jaws are clinically rare. In this paper, we report a case of epidermoid cyst occurring in the mandible with embedded teeth and discuss the etiology, clinical manifestations, diagnosis, and treatment of epidermoid cysts in the jaws in the context of the relevant literature.


Asunto(s)
Quiste Epidérmico , Humanos , Quiste Epidérmico/diagnóstico , Quiste Epidérmico/cirugía , Cráneo , Mandíbula , Diagnóstico Diferencial , Células Epiteliales
15.
Shanghai Kou Qiang Yi Xue ; 32(2): 214-219, 2023 Apr.
Artículo en Zh | MEDLINE | ID: mdl-37154007

RESUMEN

PURPOSE: To evaluate the long-term clinical efficacy of short implants and analyze the influencing factors of the survival rate. METHODS: A total of 178 patients who received implant therapy in the Department of Stomatology, the Fourth Affiliated Hospital of Nanchang University from January 2010 to December 2014 were selected, including 334 short implants of Bicon (implant length ≤6 mm). The basic condition, restoration design, short implant survival rate and complications were observed and analyzed. SPSS 24.0 software package was used for data analysis. RESULTS: The average follow-up time of short implants was 96±17 months. During the observation period, 20 implants failed, 1 implant had mechanical complications and 6 implants had biological complications. Based on the analysis of implants and patients, the long-term cumulative survival rate of short implants was 94.0%(over 5 years survival rate was 96.4%) and 90.4% respectively. There was no significant difference between the survival rate of short implants and the patient's gender, age, whether to use special operation and the type of jaw teeth(P<0.05). Smoking and periodontitis were risk factors for failure of short implants(P<0.05).The difference of short implant survival rate between short implants restoration with combined crowns and single crowns was statistically significant(P<0.05). The survival rate of short implant in mandible was higher than that in maxilla(P<0.05). CONCLUSIONS: Under the standards clinical program and operation, short implant can be used to shorten the implant restoration cycle and avoid complicated bone augmentation which can achieve good long-term clinical effect. Short implant should be used to strictly control the risk factors that affect the survival of short implant.


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental , Humanos , Prótesis Dental de Soporte Implantado/efectos adversos , Resultado del Tratamiento , Coronas , Factores de Riesgo , Fracaso de la Restauración Dental , Implantes Dentales/efectos adversos , Estudios de Seguimiento , Estudios Retrospectivos
16.
New Phytol ; 194(4): 932-943, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22432590

RESUMEN

Brassinosteroids (BRs) play a vital role in plant growth, stress tolerance and productivity. Here, the involvement of BRs in the regulation of CO(2) assimilation and cellular redox homeostasis was studied. The effects of BRs on CO(2) assimilation were studied in cucumber (Cucumis sativus) through the analysis of the accumulation of H(2)O(2) and glutathione and photosynthesis-related enzyme activities using histochemical and cytochemical detection or a spectrophotometric assay, and Rubisco activase (RCA) using western blot analysis and immunogold labeling. Exogenous BR increased apoplastic H(2)O(2) accumulation, the ratio of reduced to oxidized glutathione (GSH:GSSG) and CO(2) assimilation, whereas a BR biosynthetic inhibitor had the opposite effects. BR-induced CO(2) assimilation was decreased by a H(2)O(2) scavenger or inhibition of H(2)O(2) generation, GSH biosynthesis and the NADPH-generating pentose phosphate pathway. BR-, H(2)O(2) - or GSH-induced CO(2) assimilation was associated with increased activity of enzymes in the Benson-Calvin cycle. Immunogold labeling and western blotting showed that BR increased the content of RCA and this effect was blocked by inhibitors of redox homeostasis. These results strongly suggest that BR-induced photosynthesis involves an H(2)O(2) -mediated increase in the GSH:GSSG ratio, which may positively regulate the synthesis and activation of redox-sensitive enzymes in carbon fixation.


Asunto(s)
Brasinoesteroides/farmacología , Dióxido de Carbono/metabolismo , Colestanonas/farmacología , Cucumis sativus/efectos de los fármacos , Glutatión/metabolismo , Reguladores del Crecimiento de las Plantas/farmacología , Esteroides Heterocíclicos/farmacología , Cucumis sativus/metabolismo , Homeostasis , Peróxido de Hidrógeno/metabolismo , Oxidación-Reducción , Fotosíntesis
17.
Am J Bot ; 99(4): e149-53, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22447986

RESUMEN

PREMISE OF THE STUDY: Expressed sequence tag (EST)-derived simple sequence repeat (SSR) markers were developed in Pisum sativum for further use in genetic studies and breeding programs. METHODS AND RESULTS: Forty-one novel EST-SSR primers were developed and characterized for size polymorphism in 32 Pisum sativum individuals from four populations from China. In each population, the number of alleles per locus ranged from one to seven, with observed heterozygosity and expected heterozygosity ranging from 0 to 0.8889 and 0 to 0.8400, respectively. Furthermore, 53.7% of these markers could be transferred to the related species, Vicia faba. CONCLUSIONS: The developed markers have potential for application in the study of genetic diversity, germplasm appraisal, and marker-assisted breeding in pea and other legume species.


Asunto(s)
Etiquetas de Secuencia Expresada , Repeticiones de Microsatélite/genética , Pisum sativum/genética , China , Cartilla de ADN/metabolismo , Marcadores Genéticos , Geografía
18.
Ecotoxicol Environ Saf ; 80: 28-36, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22364830

RESUMEN

Polycyclic aromatic hydrocarbons (PAHs) are toxic to both plants and animals. The enhancement of plant tolerance and detoxification capacity is important for the plant-based remediation of PAHs. Therefore, we investigated the effects of 24-epibrassinolide (EBR) on the metabolism of a three-ringed PAH (phenanthrene-PHE) and subsequent stress tolerance in tomato (Solanum lycopersicum L.) plants. Exposure to PHE (300 µM) for 21 d significantly decreased biomass and net CO(2) assimilation (P(n)) but induced photoinhibition, malondialdehyde (MDA), H(2)O(2) and antioxidant enzymes. Obvious ultrastructural alterations were observed in the PHE-treated root tip cells. Importantly, the foliar application of EBR (0.1 µM) significantly increased biomass, P(n) and antioxidant enzyme activities but decreased MDA and H(2)O(2) compared with PHE alone and saved the root cells from severe damage. The expression of detoxification genes (CYP90b3, GSH1, GST1), reduced glutathione (GSH) content and glutathione S-transferase activity in the EBR+PHE-treated plants were higher than those of PHE alone. Additionally, lower levels of PHE residues in the roots were observed as a result of EBR+PHE treatment. Taken together, our results strongly suggest an enhanced and coordinated detoxification and degradation of PHE by EBR.


Asunto(s)
Brasinoesteroides/farmacología , Hidrocarburos Policíclicos Aromáticos/metabolismo , Solanum lycopersicum/metabolismo , Adaptación Fisiológica , Biodegradación Ambiental , Glutatión/metabolismo , Peróxido de Hidrógeno/metabolismo , Solanum lycopersicum/efectos de los fármacos , Solanum lycopersicum/crecimiento & desarrollo , Solanum lycopersicum/fisiología , Malondialdehído/metabolismo , Raíces de Plantas/metabolismo
19.
Ecotoxicol Environ Saf ; 80: 132-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22401953

RESUMEN

Polycyclic aromatic hydrocarbons (PAHs) are global environmental problem. To better understand the growth and physiological responses to atmospheric PAHs, we investigated biomass, photosynthetic machinery and antioxidant system in pakchoi, cucumber, flowering chinese cabbage, tomato and lettuce under various levels of phenanthrene (PHE) stress. Foliar exposure to PHE for 14d resulted in a dose dependent decrease in growth, photosynthesis and chlorophyll contents. With few exceptions, antioxidant enzymes (superoxide dismutase, guaicol peroxidase, catalase, ascorbate peroxidase and glutathione reductase) were upregulated following exposure to PHE. Dose dependent increase in malondialdehyde contents together with H(2)O(2) accumulation suggested an occurrence of oxidative stress following PHE exposure. However, to some extent, growth and antioxidant defense responses differ from species to species. Difference in defense capacity might result in different tolerance and phytotoxicity among the studied vegetables. Taken together, phytotoxicity of PHE to five vegetables could be sequenced in the following order: pakchoi>cucumber>lettuce>tomato>flowering chinese cabbage.


Asunto(s)
Fenantrenos/toxicidad , Fotosíntesis/efectos de los fármacos , Contaminantes del Suelo/toxicidad , Verduras/efectos de los fármacos , Ascorbato Peroxidasas/metabolismo , Catalasa/metabolismo , Clorofila/metabolismo , Glutatión Reductasa/metabolismo , Peróxido de Hidrógeno/metabolismo , Malondialdehído/metabolismo , Estrés Oxidativo , Peroxidasas/metabolismo , Hojas de la Planta/metabolismo , Superóxido Dismutasa/metabolismo , Verduras/crecimiento & desarrollo , Verduras/metabolismo
20.
Front Oncol ; 12: 868076, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35847890

RESUMEN

Purposes/Objectives: Historically, motion correlation between internal tumor and external surrogates have been based on limited sets of X-ray or magnetic resonance (MR) images. With the recent clinical implementation of MR-guided linear accelerators, a vast quantity of continuous planar real-time MR imaging data is acquired. In this study, information was extracted from MR cine imaging during liver cancer treatments to establish associations between internal tumor/diaphragm and external surface/skin movement. Methods and Materials: This retrospective study used 305,644 MR image frames acquired over 118 treatment/imaging sessions of the first 23 liver cancer patients treated on an MRI-linac. 9 features were automatically determined on each MR image frame: Lung_Area, the posterior (Dia_Post), dome (Dia_Dome), and anterior (Dia_Ant) points of a diaphragmatic curve and the diaphragm curve point (Dia_Max), the chest (Chest) and the belly (Belly) skin points experiencing the maximum motion ranges; the superior-interior (SI) and posterior-anterior (PA) positions of a target. For every session, correlation analyses were performed twice among the 9 features: 1) over a breath-hold (BH) set and 2) on a pseudo free-breathing (PFB) generated by removing breath-holding frames. Results: 303,123 frames of images were successfully analyzed. For BH set analysis, correlation coefficients were as follows: 0.94 ± 0.07 between any two features among Dia_Post, Dia_Dome, Dia_Max, and Lung_Area; 0.95 ± 0.06 between SI and any feature among Dia_Post, Dia_Dome, Dia_Max, or Lung_Area; 0.76 ± 0.29 between SI and Belly (with 50% of correlations ≥ 0.87). The PFB set had 142,862 frames of images. For this set, correlation coefficients were 0.96 ± 0.06 between any two features among Dia_Post, Dia_Dome, Dia_Max, and Lung_Area; 0.95 ± 0.06 between SI and any feature among Dia_Post, Dia_Dome, Dia_Max, or Lung_Area; 0.80 ± 0.26 between SI and Belly (with 50% of correlations ≥ 0.91). Conclusion: Diaphragmatic motion as assessed by cine MR imaging is highly correlated with liver tumor motion. Belly vertical motion is highly correlated with liver tumor longitudinal motion in approximately half of the cases. More detailed analyses of those cases displaying weak correlations are in progress.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA