Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Dairy Sci ; 99(7): 5230-5243, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27132105

RESUMEN

Microfiltration (MF) is a well-known process that can be used in the dairy industry to separate caseins from serum proteins (SP) in skim milk using membranes with a pore diameter of 0.1µm. Graded permeability ceramic membranes have been studied widely as means of improving milk fractionation by overcoming problems encountered with other MF membranes. The ideal operating parameters for process efficiency in terms of membrane selectivity, permeate flux, casein loss, SP transmission, energy consumption, and dilution with water remain to be determined for this membrane. Our objective was to evaluate the effects of transmembrane pressure (TMP), volumetric concentration factor (VCF), and diafiltration on overall process efficiency. Skim milk was processed using a pilot-scale MF system equipped with 0.72-m(2) graded permeability membranes with a pore size of 0.1µm. In the first experiment, in full recycle mode, TMP was set at 124, 152, 179, or 207 kPa by adjusting the permeate pressure at the outlet. Whereas TMP had no significant effect on permeate and retentate composition, 152 kPa was found to be optimal for SP removal during concentration and concentration or diafiltration experiments. When VCF was increased to 3×, SP rejection coefficient increased along with energy consumption and total casein loss, whereas SP removal rate decreased. Diafiltering twice allowed an increase in total SP removal but resulted in a substantial increase in energy consumption and casein loss. It also reduced the SP removal rate by diluting permeate. The membrane surface area required for producing cheese milk by blending whole milk, cream, and MF retentate (at different VCF) was estimated for different cheese milk casein concentrations. For a given casein concentration, the same quantity of permeate and SP would be produced, but less membrane surface area would be needed at a lower retentate VCF. Microfiltration has great potential as a process of adding value to conventional cheesemaking processes, but its cost-effectiveness at a large scale remains to be demonstrated.


Asunto(s)
Filtración , Leche/química , Animales , Proteínas Sanguíneas , Cerámica , Manipulación de Alimentos , Membranas Artificiales , Proteínas de la Leche , Permeabilidad
2.
Phys Rev Lett ; 105(26): 266605, 2010 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-21231696

RESUMEN

We study a single polaron in the Su-Schrieffer-Heeger (SSH) model using four different techniques (three numerical and one analytical). Polarons show a smooth crossover from weak to strong coupling, as a function of the electron-phonon coupling strength λ, in all models where this coupling depends only on phonon momentum q. In the SSH model the coupling also depends on the electron momentum k; we find it has a sharp transition, at a critical coupling strength λ(c), between states with zero and nonzero momentum of the ground state. All other properties of the polaron are also singular at λ=λ(c). This result is representative of all polarons with coupling depending on k and q, and will have important experimental consequences (e.g., in angle-resolved photoemission spectroscopy and conductivity experiments).

3.
Sci Rep ; 9(1): 13708, 2019 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-31548549

RESUMEN

Discovering the low-energy conformations of a molecule is of great interest to computational chemists, with applications in in silico materials design and drug discovery. In this paper, we propose a variable neighbourhood search heuristic for the conformational search problem. Using the structure of a molecule, neighbourhoods are chosen to allow for the efficient use of a binary quadratic optimizer for conformational search. The method is flexible with respect to the choice of molecular force field and the number of discretization levels in the search space, and can be further generalized to take advantage of higher-order binary polynomial optimizers. It is well-suited for the use of devices such as quantum annealers. After carefully defining neighbourhoods, the method easily adapts to the size and topology of these devices, allowing for seamless scaling alongside their future improvements.

4.
J Chromatogr A ; 1209(1-2): 104-10, 2008 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-18822417

RESUMEN

Some alkylsilica columns carry a positive charge at low pH, as determined by anion-exchange with nitrate ion. In the present study, the relative positive charge for 14 alkylsilica columns was measured for a mobile-phase pH 3.0. All but 3 of these columns were found to carry a significant positive charge under these conditions. The relative positive charge on these columns was found to correlate approximately with two other column characteristics: relative cation-exchange behavior as measured by the hydrophobic-subtraction model (values of C-2.8), and slow equilibration of the column to changes in the mobile-phase-as evidenced by a slow change in the retention of anionic and cationic solutes with time. The origin of this positive charge may arise from the bonding process, with incorporation of some cationic entity into the stationary phase.


Asunto(s)
Resinas de Intercambio Aniónico/química , Cromatografía por Intercambio Iónico/métodos , Dióxido de Silicio/química
5.
J Chromatogr A ; 1191(1-2): 2-20, 2008 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-18036535

RESUMEN

A total of 371 reversed-phase columns have now been characterized in terms of selectivity, based on five solute-column interactions (the hydrophobic-subtraction model). The present study illustrates the use of these data for interpreting peak-tailing and column stability. New insights are also provided concerning column selectivity as a function of ligand and silica type, and the selection of columns for orthogonal separations is re-examined. Some suggestions for the quality control of reversed-phase columns during manufacture are offered.


Asunto(s)
Cromatografía Liquida/métodos , Enlace de Hidrógeno , Interacciones Hidrofóbicas e Hidrofílicas , Modelos Químicos , Sensibilidad y Especificidad
6.
Rev Mal Respir ; 25(9): 1087-93, 2008 Nov.
Artículo en Francés | MEDLINE | ID: mdl-19106904

RESUMEN

INTRODUCTION: Exhaled nitric oxide (FeNO) is a putative non-invasive marker of eosinophilic airway inflammation with a good predictive value for allergic asthma in preschool children. The aim of the present study was to compare FeNO after acute viral bronchiolitis (AVB) in children aged less than 2 years without atopic dermatitis (AD) vs those with atopic dermatitis, as well as children with AD without any history of AVB. METHODS: Forty-two children (mean age +/- SD: 12.3 +/- 5.2 months; range 5.0-23.5; sex-ratio M: F=1.3: 1) were included in this prospective study, > 8 wks after an episode of AVB. The patients' atopic status was assessed both by clinical phenotype and IgE- mediated response to inhaled and/or food allergens. FeNO (ppb) was measured off-line by the chemoluminescence method on samples obtained from gas collected in a balloon during tidal breathing. RESULTS: There was a significant difference between the AVB/AD (23.4 +/- 14.3 ppb, n=15) vs the AVB without AD group (13.5 +/- 10. 1 ppb, n=13) or the AD without AVB group (11.0 +/- 8.3 ppb, n=14). Maternal feeding for more than 2 months decreased FeNO by 50%. CONCLUSION: Atopic children below 2 years with AD produce more NO after AVB than non-atopic children or atopic children without any history of AVB. Maternal feeding decreases FeNO.


Asunto(s)
Bronquiolitis Viral/metabolismo , Dermatitis Atópica/complicaciones , Óxido Nítrico/metabolismo , Enfermedad Aguda , Biomarcadores/metabolismo , Estudios Transversales , Femenino , Humanos , Lactante , Inflamación/metabolismo , Masculino , Proyectos Piloto , Estudios Prospectivos
7.
Curr Opin Biotechnol ; 5(1): 72-6, 1994 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-7764647

RESUMEN

Recent advances in biochromatography have focused on improvements in the design of stationary supports for liquid chromatography. During the past year, the innovative use of columns packed with small non-porous particles has significantly improved the efficiency of chromatographic separations. Bioseparations that previously took hours are now possible in only a few minutes.


Asunto(s)
Biotecnología/métodos , Cromatografía Liquida/métodos , Biotecnología/instrumentación , Cromatografía de Afinidad/instrumentación , Cromatografía de Afinidad/métodos , Cromatografía Liquida/instrumentación , Ligandos , Tamaño de la Partícula , Proteínas/aislamiento & purificación
8.
J Chromatogr A ; 1098(1-2): 123-30, 2005 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-16314168

RESUMEN

Previous work suggests that pi-pi interactions between certain solutes and both phenyl and cyano columns can contribute to sample retention and the selectivity of these two column types versus alkylsilica columns. Recent studies also suggest that dipole-dipole interactions are generally unimportant for retention on cyano columns. The present study presents data for 44 solutes, three columns and two different mobile phases that were selected to further test these conclusions. We find that pi-pi interactions can contribute to retention on both cyano and phenyl columns, while dipole-dipole interactions are likely to be significant for the retention of polar aliphatic solutes on cyano columns. When acetonitrile/water mobile phases are used, both pi-pi and dipole-dipole interactions are suppressed, compared to the use of methanol/water.


Asunto(s)
Cromatografía Liquida/métodos , Compuestos Orgánicos/química , Resinas Sintéticas/química , Dióxido de Silicio/química , Acetonitrilos/química , Adsorción , Cromatografía Liquida/instrumentación , Metanol/química , Sensibilidad y Especificidad , Solubilidad , Solventes/química , Factores de Tiempo , Agua/química
9.
J Chromatogr A ; 1062(1): 57-64, 2005 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-15679143

RESUMEN

Eleven cyanopropyl ("cyano") columns were characterized by means of a relationship developed originally for alkyl-silica columns. Compared to type-B alkyl-silica columns (i.e., made from pure silica), cyano columns are much less hydrophobic (smaller H), less sterically restricted (smaller S*), and have lower hydrogen-bond acidity (smaller A). Because sample retention is generally much weaker on cyano versus other columns (e.g., C8, C18), a change to a cyano column usually requires a significantly weaker mobile phase in order to maintain comparable values of k for both columns. For this reason, practical comparisons of selectivity between cyano and other columns (i.e., involving different mobile phases for each column) must take into account possible changes in separation due to the change in mobile phase, as well as change in the column.


Asunto(s)
Cromatografía Liquida/instrumentación , Enlace de Hidrógeno , Sensibilidad y Especificidad
10.
J Chromatogr A ; 1062(1): 65-78, 2005 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-15679144

RESUMEN

As reported previously, five solute-column interactions (hydrophobicity, steric resistance, hydrogen-bond acidity and basicity, ionic interaction) quantitatively describe column selectivity for 163 alkyl-silica, polar-group and cyano columns. In the present study, solute retention and column selectivity for 11 phenyl and 5 fluoro-substituted columns were compared with alkyl-silica columns of similar ligand length. It is concluded that two additional solute-column interactions may be significant in affecting retention and selectivity for the latter columns: (a) dispersion interactions of varying strength as a result of significant differences in bonded-phase polarizability or refractive index and (b) pi-pi interactions in the case of phenyl columns and aromatic solutes. These 16 phenyl and fluoro columns were also characterized in terms of hydrophobicity, steric resistance, hydrogen-bond acidity and basicity, and ionic interaction.


Asunto(s)
Cromatografía Liquida/instrumentación , Enlace de Hidrógeno , Refractometría , Sensibilidad y Especificidad
11.
Immunol Lett ; 48(1): 1-9, 1995 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8847083

RESUMEN

First described as an interface between blood and tissues, the endothelial cells are now known to be also involved in haemostasis, inflammatory and immune responses. Recent studies have reported that the endothelial cells represent a heterogeneous population of cells with organ-specific properties. This report describes the phenotype analyzed by flow cytometry of human umbilical vascular endothelial cells (HUVEC). For this purpose, we use monoclonal antibodies (Mabs) recognizing B cell antigens (CD10, 19, 20, 21, 22, 23, 24, 38, 40), T cell antigens (CD1, 2, 3, 4, 5, 6, 7, 8), myeloid antigens (CD13, 14, 15, 34, 35, 64), platelet antigens (CD9, 31, 51, 62P), NK and non-lineage cell antigens (CD16, 45, 56, 57), activation antigens (CD25, 30, 69, 71) and adhesion molecules (CD11a, CD11b, 29, 44, 54, 62E, 102, 106). Mabs recognizing MHC ClI or ClII molecules are also tested. Firstly, we show that HUVEC co-express some haemopoietic antigens with different levels of expression. Secondly, this study reveals that the HUVEC population does not represent a homogeneous cell population. Different endothelial cell subsets are identified. These phenotypical differences could reflect specialization of HUVEC performing different functions. The significant of haemopoietic antigen expression on the HUVEC surface will be discussed.


Asunto(s)
Antígenos CD/biosíntesis , Endotelio Vascular/inmunología , Cordón Umbilical/citología , Antígenos de Diferenciación de Linfocitos B/biosíntesis , Antígenos de Diferenciación Mielomonocítica/biosíntesis , Antígenos de Diferenciación de Linfocitos T/biosíntesis , Antígenos de Plaqueta Humana/biosíntesis , Antígenos de Superficie/biosíntesis , Moléculas de Adhesión Celular/biosíntesis , Células Cultivadas , Endotelio Vascular/citología , Citometría de Flujo , Genes MHC Clase I/inmunología , Genes MHC Clase II/inmunología , Humanos , Células Asesinas Naturales/inmunología
12.
Biochem Pharmacol ; 42(11): 2171-80, 1991 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-1958235

RESUMEN

1-Naphthylisothiocyanate (ANIT) is a model compound which causes cholestasis in laboratory animals. Various biochemical and morphological changes including biliary epithelial and parenchymal cell necrosis occur in the liver of animals treated with ANIT. Although the mechanism(s) for these effects is not understood, a role for glutathione (GSH) in toxicity has been implicated. The possible role of GSH in hepatocellular toxicity caused by ANIT was investigated in this study. Treatment of freshly isolated rat hepatocytes with ANIT caused a concentration- and time-dependent depletion of cellular GSH that preceded lactate dehydrogenase (LDH) leakage. Analysis of the incubation medium indicated that the majority of the cellular GSH which was lost was present extracellularly as GSH or as a GSH-releasing compound. Mixing ANIT with GSH at pH 7.5 yielded a compound that was characterized by HPLC and fast atom bombardment-mass spectrometry (FAB-MS) S-(N-naphthyl-thiocarbamoyl)-L-glutathione (GS-ANIT). When dissolved in aqueous solutions at neutral pH, 95% of GS-ANIT dissociated to yield free ANIT and GSH. Under conditions designed to maximize formation and stability of GS-ANIT, GS-ANIT was found in the extracellular medium of hepatocytes treated with ANIT. Treatment of hepatocytes with the GS-ANIT caused GSH depletion and LDH leakage similar to that observed with equimolar amounts of ANIT. These data suggest that ANIT depletes hepatocytes of GSH through a reversible conjugation process. Such a process may play a role in the toxicity of ANIT.


Asunto(s)
1-Naftilisotiocianato/metabolismo , Glutatión/metabolismo , Hígado/citología , Hígado/metabolismo , 1-Naftilisotiocianato/efectos adversos , Animales , Células Cultivadas , Cinética , Hígado/efectos de los fármacos , Masculino , Ratas , Ratas Endogámicas
13.
J Chromatogr A ; 1015(1-2): 53-64, 2003 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-14570319

RESUMEN

Reversed-phase columns that have been stored in buffer-free solvents can exhibit pronounced retention-time drift when buffered, low-pH mobile phases are used with ionized solutes. Whereas non-ionized compounds exhibit constant retention times within 20 min of the beginning of mobile phase flow, the retention of ionized compounds can continue to change (by 20% or more) for several hours. If mobile phase pH is changed from low to high and back again, an even longer time may be required before the column reaches equilibration at low pH. The speed of column equilibration for ionized solutes can vary significantly among different reversed-phase columns and is not affected by flow rate.


Asunto(s)
Cromatografía Liquida/instrumentación , Concentración de Iones de Hidrógeno , Iones
14.
Appl Ergon ; 32(6): 573-82, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11703043

RESUMEN

The majority of injuries to truckers are caused by falls during the descent from the cab of the truck. Several studies have shown that the techniques used to descend from the truck and the layout of the truck's cabin are the principal cause of injury. The goal of the present study was to measure the effects of the descent techniques used by the trucker and the layout of the truck's cabin on the impact forces absorbed by the lower limbs and the back. Kinematic data, obtained with the aid of a video camera, were combined with the force platform data to allow for calculation of the lower limb and L5-S1 torques as well as L5-S1 compressive forces. The trucker descended from two different conventional tractor cabin layouts. Each trucker descended from cabin using either "facing the truck" (FT) or "back to the truck" (BT) techniques. The results demonstrate that the BT technique produces greater ground impact forces than the FT technique, particularly when the truck does not have a handrail. The BT technique also causes an increase in the compressive forces exerted on the back. In conclusion, the use of the FT technique along with the aids (i.e., handrails and all the steps) help lower the landing impact forces as well as the lumbosacral compressive forces.


Asunto(s)
Vehículos a Motor , Ocupaciones , Heridas y Lesiones/fisiopatología , Adulto , Anciano , Dorso/fisiopatología , Fenómenos Biomecánicos , Humanos , Pierna/fisiopatología , Persona de Mediana Edad , Heridas y Lesiones/etiología
15.
Int J Occup Saf Ergon ; 5(1): 3-29, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10602636

RESUMEN

The issue of climbability has been raised on several occasions for more than a decade in North America. Presently, climbability is estimated from the pole hardness measured by the Pilodyn measurements (6 J). However, the use of Pilodyn measurements to discriminate the pole hardness value is criticized by climbers, who claim that the Pilodyn hardness measurement is affected by species-treatment combinations and that it does not reflect gaff penetration or climbability. Furthermore, climbability evaluations have been conducted in which test poles were climbed by linemen, and corresponding subjective ratings were recorded. However, the ability of psychophysical measurements to accurately discriminate close hardness pole values and to differentiate species-treatment combinations at specific hardness levels have not yet been fully documented. The aim of this study is to evaluate the psychophysical perception of linemen and the mechanical measurements of gaff penetration and gaff impact during the climbing of different wood species and treatment combinations in order to compare these results with Pilodyn measurements within a precise range of pole hardnesses, to study the relationships between these variables, and, finally, to propose various design guidelines for the development of a better tool for the evaluation of climbability.


Asunto(s)
Salud Laboral , Seguridad , Adulto , Humanos , Masculino , Destreza Motora , Competencia Profesional , Zapatos , Teléfono
16.
J Chromatogr A ; 1218(40): 7110-29, 2011 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-21872865

RESUMEN

The contribution of cation exchange to solute retention for type-B alkylsilica columns (made from high-purity silica) has been examined in terms of the hydrophobic-subtraction (H-S) model of reversed-phase column selectivity. The relative importance of cation exchange in the separation of ionized bases by reversed-phase chromatography (RPC) varies with (a) column acidity (values of the column cation-exchange capacity C), (b) mobile-phase pH and buffer concentration, and (c) the nature of the buffer cation. The effects of each of these separation variables on cation retention were examined. The contribution of cation exchange (and other ionic interactions) to solute retention is represented in the H-S model by properties of the solute (κ') and column (C), respectively. Values of κ' for 87 solutes have been examined as a function of solute molecular structure, and values of C for 167 type-B alkylsilica columns have been related to various column properties: ligand length (e.g., C(8) vs. C(18)) and concentration (µmol/m(2)), pore diameter (nm), and end-capping. These results contribute to a more detailed picture of the retention of cationic solutes in RPC as a function of separation conditions. While previous work suggests that the ionization of type-B alkylsilica columns is generally negligible with mobile-phase pH<7 (as a result of which cation exchange then becomes insignificant), the present study provides evidence for cation exchange (and presumably silanol ionization) at a pH as low as 3 for most columns.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cromatografía de Fase Inversa/métodos , Cationes/química , Concentración de Iones de Hidrógeno , Interacciones Hidrofóbicas e Hidrofílicas , Intercambio Iónico , Modelos Químicos , Análisis de Regresión , Dióxido de Silicio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA