Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ultrasound Obstet Gynecol ; 63(4): 472-480, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-37743665

RESUMEN

OBJECTIVES: Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) facilitates the non-invasive in-vivo evaluation of placental oxygenation. The aims of this study were to identify and quantify a relative BOLD effect in response to hyperoxia in the human placenta and to compare it between pregnancies with and those without fetal growth restriction (FGR). METHODS: This was a prospective multicenter study (NCT02238301) of 19 pregnancies with FGR (estimated fetal weight (EFW) on ultrasound < 5th centile) and 75 non-FGR pregnancies (controls) recruited at two centers in Paris, France. Using a 1.5-Tesla MRI system, the same multi-echo gradient-recalled echo (GRE) sequences were performed at both centers to obtain placental T2* values at baseline and in hyperoxic conditions. The relative BOLD effect was calculated according to the equation 100 × (hyperoxic T2* - baseline T2*)/baseline T2*. Baseline T2* values and relative BOLD effect were compared according to EFW (FGR vs non-FGR), presence/absence of Doppler anomalies and birth weight (small-for-gestational age (SGA) vs non-SGA). RESULTS: We observed a relative BOLD effect in response to hyperoxia in the human placenta (median, 33.8% (interquartile range (IQR), 22.5-48.0%)). The relative BOLD effect did not differ significantly between pregnancies with and those without FGR (median, 34.4% (IQR, 24.1-48.5%) vs 33.7% (22.7-47.4%); P = 0.95). Baseline T2* Z-score adjusted for gestational age at MRI was significantly lower in FGR pregnancies compared with non-FGR pregnancies (median, -1.27 (IQR, -4.87 to -0.10) vs 0.33 (IQR, -0.81 to 1.02); P = 0.001). Baseline T2* Z-score was also significantly lower in those pregnancies that subsequently delivered a SGA neonate (n = 23) compared with those that delivered a non-SGA neonate (n = 62) (median, -0.75 (IQR, -3.48 to 0.29) vs 0.35 (IQR, -0.79 to 1.05); P = 0.01). CONCLUSIONS: Our study confirms a BOLD effect in the human placenta and that baseline T2* values are significantly lower in pregnancies with FGR. Further studies are needed to evaluate whether such parameters may detect placental insufficiency before it has a clinical impact on fetal growth. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Hiperoxia , Placenta , Recién Nacido , Embarazo , Femenino , Humanos , Placenta/diagnóstico por imagen , Estudios Prospectivos , Retardo del Crecimiento Fetal/diagnóstico por imagen , Recién Nacido Pequeño para la Edad Gestacional , Peso Fetal , Edad Gestacional , Ultrasonografía Prenatal/métodos
2.
J Environ Radioact ; 182: 174-176, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29203328

RESUMEN

Elements to answer the points raised in the Letter in question are proposed, notably about exposure metrics and their influence on the results and statistical power of epidemiological studies.


Asunto(s)
Exposición a Riesgos Ambientales , Rayos gamma , Francia , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA