Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 60(5)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38793002

RESUMEN

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Monitoreo Fisiológico/métodos , Telemedicina/tendencias , Desfibriladores Implantables/normas
2.
J Cardiovasc Electrophysiol ; 34(3): 728-737, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36477909

RESUMEN

INTRODUCTION: Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS: A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS: The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION: Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Remoción de Dispositivos/métodos , Electrodos Implantados , Estudios Retrospectivos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 101(6): 1144-1153, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36924020

RESUMEN

AIMS: To compare outcomes of patients who underwent left atrial appendage occlusion (LAAO) for nonvalvular atrial fibrillation (NVAF) and contraindication to anticoagulants due to history of either gastrointestinal (GI) or intracranial (IC) bleeding. METHODS: Patients with NVAF that underwent LAAO for GI or IC bleeding from seven centers were included in this observational study. Baseline characteristics, procedural features, and follow-up data were collected, and compared between the two groups. The primary outcomes were incidence of ischemic and hemorrhagic events at 12-month. RESULTS: Six hundred twenty-eight patients were included, 57% with previous GI-bleeding, and 43% with previous IC-bleeding. Median CHA 2 DS 2-VASc score was 4 (interquartile range [IQRs]: 3-5) for both GI-bleeding and IC-bleeding patients, while GI-bleeding patients had a higher HAS-BLED score (4 [IQRs: 3-4] vs. 3 [IQRs]: 2-3]; p = 0.001). At 12-month follow-up, relative risk reduction for stroke was similar between the two groups. The GI-bleeding group had more hemorrhagic events compared to IC-bleeding group (any bleeding 8.4% vs. 3.2%; p = 0.012; major bleeding BARC 3-5: 4.3% vs. 1.8; p = 0.010). At multivariate analysis history of GI bleeding was an independent predictor of hemorrhagic events (adjusted HR: 2.39, 95% confidence interval: 1.02-5.63; p = 0.047). CONCLUSIONS: Outcomes after LAAO may be affected by the different indications for the procedure. In our study, GI-bleeding and IC-bleeding as indication to LAAO differ in their baseline characteristics. LAAO confirms its efficacy in ischemic risk reduction in both groups, while GI bleeding seems to be an independent predictor of bleeding recurrence at 12 months behind the antithrombotic regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/prevención & control , Hemorragias Intracraneales/etiología , Sistema de Registros , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Lógica
4.
Nutr Metab Cardiovasc Dis ; 33(7): 1323-1329, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37248142

RESUMEN

BACKGROUND AND AIMS: Interest in the role of atrial substrate in maintaining Atrial Fibrillation (AF) is growing. Fibrosis is the culprit in the electrical derangement of the myocytes. Many cardiovascular risk factors are known to be linked to atrial scarring; among them Uric Acid (UA) is emerging. The purpose of our study is to find whether UA is associated with Left Atrium (LA) with pathological substrate. METHODS AND RESULTS: 81 patients who underwent radiofrequency transcatheter ablation for nonvalvular AF at the cardiological department of the Niguarda Hospital were enrolled in an observational, cross-sectional, single-center study. UA levels were analysed before the procedure. High density electroanatomic mapping of the LA was performed and patients were divided according to the presence or not of areas of pathological substrate (bipolar voltage <0.5 mV in sinus rhythm). 19 patients showed a LA with pathological substrate. These subjects showed a significant higher prevalence of persistent phenotype of AF (84.2 vs. 25.8%, p < 0.001). UA levels were significantly higher in the group of patients with LA with pathological substrate (6.8 ± 1.9 vs 5.3 ± 1.4 mg/dL, p < 0.001) as well as the prevalence of hyperuricemia (26.5 vs. 6.5%, p = 0.021). The association between uric acid LA with pathological substrate remains significant even after correction for confounding factors (age, left ventricular dysfunction, valvular disease, arrythmia phenotype and furosemide use) and also when the ratio UA/creatinine was evaluated. CONCLUSIONS: In a population of patients who underwent AF ablation, higher UA levels were significantly associated with pathological LA substrate at electro-anatomical mapping.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ácido Úrico , Estudios Transversales , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Fibrosis
5.
Medicina (Kaunas) ; 59(2)2023 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-36837606

RESUMEN

Electrical storm is a medical emergency characterized by ventricular arrythmia recurrence that can lead to hemodynamic instability. The incidence of this clinical condition is rising, mainly in implantable cardioverter defibrillator patients, and its prognosis is often poor. Early acknowledgment, management and treatment have a key role in reducing mortality in the acute phase and improving the quality of life of these patients. In an emergency setting, several measures can be employed. Anti-arrhythmic drugs, based on the underlying disease, are often the first step to control the arrhythmic burden; besides that, new therapeutic strategies have been developed with high efficacy, such as deep sedation, early catheter ablation, neuraxial modulation and mechanical hemodynamic support. The aim of this review is to provide practical indications for the management of electrical storm in acute settings.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Humanos , Calidad de Vida , Arritmias Cardíacas , Antiarrítmicos/uso terapéutico , Pronóstico
6.
J Cardiovasc Electrophysiol ; 33(1): 102-108, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34783107

RESUMEN

BACKGROUND: Transvenous lead extraction (TLE) is rising in parallel to cardiac implantable electronic device implantations. Persistent left side superior vena cava (PLSVC) is a relatively common anatomical variant in the healthy population; TLE in patients with a PLSVC is rare. METHOD: Data were collated from 6 European TLE institutes of 10 patients who had undergone lead extraction with a PLSVC. Patient demographics, procedural challenges and outcomes were reported. RESULTS: Ten patients aged 73.4 ± 7.8 years (60% male) underwent TLE of 20 leads (3 left ventricle, 10 right ventricle, 7 right atrium) with dwell time of 82.95 ± 39.1 months. Of the 10 cases, 4 had an infection indication and 5 were biventricular system extractions; 25% of the extracted leads were defibrillator leads. The majority of the procedures were completed in the cardiac catheterization suite (80%) under general anaesthesia (60%) by cardiologists (80%) using a rotational powered sheath (65%). The Tandem approach was used successfully in 3 cases. Complete procedural success was obtained in 100% of cases in the absence of complications within 127.4 ± 74.7 min. There was no 30-day mortality. CONCLUSION: TLE in PLSVC is feasible albeit rare. Standard extraction techniques in experienced hands are associated with favorable outcomes; the Tandem procedure may be an additional technique to improve the safety and efficacy of TLE in PLSVC.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Vena Cava Superior Izquierda Persistente , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Femenino , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
7.
Eur J Clin Invest ; 52(1): e13658, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34310688

RESUMEN

BACKGROUND: Limited clinical data exist describing the use of direct oral anticoagulants (DOACs) in patient with extreme body weight. Thus, the International Society of Thrombosis and Haemostasis (ISTH) recommends avoiding DOACs in patients with weight >120 Kg, and on the contrary, no restrictions exist for underweight patients. OBJECTIVE: To evaluate the effects of extreme body weight on DOAC activity and to compare the clinical outcomes of patients with an extreme body weight versus patients with a normal weight (61-119 Kg) treated with DOACs. METHODS: Single tertiary care Italian centre multidisciplinary registry including nonvalvular atrial fibrillation (NVAF) patients treated with DOACs. Based on weight, three subcohorts were defined: (i) underweight patients (≤60 Kg); (ii) patients with a normal weight (61-119 Kg, as control group); and (iii) overweight patients (≥120 Kg). Primary efficacy endpoint was 2-year rate of thromboembolic events. Primary safety endpoint was 2-year rate of major bleeding. Event-free survival curves among groups were compared using Cox-Mantel test. RESULTS: 812 NVAF patients were included, 108 patients weighed ≤60 Kg (13%, underweight), 688 weighed between 61 and 119 Kg (85%, normal weight), and 16 weighed ≥120 Kg (2%, overweight). In particular, among underweight patients, dabigatran was prescribed in 26% patients, apixaban in 27%, rivaroxaban in 28% and edoxaban in 22% ones. Instead, among overweight patients, 44% were treated with dabigatran, 25% with apixaban, 25% with rivaroxaban and 4% with edoxaban. Underweight patients were older, more frequently women, with lower creatinine clearance and a history of previous strokes, resulting in higher CHA2DS2-VASc score than in both remaining groups. Up to 2 years, no statistically significant difference was observed between the three groups of weight for thromboembolic events (P = .765) and for overall bleeding (P = .125), but a trend towards decreased overall bleeding rates was noticed as weight increased (24.1% vs 16.7% vs 12.5%, respectively). CONCLUSION: In this tertiary care centre registry, 15% of patients treated with DOACs presented an extreme weight. Compared to patients with a normal weight, no significant rates of thromboembolic events were observed for underweight or overweight patients. A trend towards decreased overall bleeding frequency as weight increased was highlighted up to 2 years. The present results should be considered as preliminary and hypothesis generating.


Asunto(s)
Anticoagulantes/administración & dosificación , Peso Corporal , Tromboembolia/prevención & control , Administración Oral , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tromboembolia/etiología
8.
Pacing Clin Electrophysiol ; 45(6): 752-760, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35403246

RESUMEN

BACKGROUND: Little is known regarding the characterization of electrical substrate in both atria in patients with atrial fibrillation (AF). METHODS: Eight consecutive patients undergoing AF ablation (five paroxysmal, three persistent) underwent electrical substrate characterization during sinus rhythm. Mapping of the left (LA) and right atrium (RA) was performed with the use of the HD Grid catheter (Abbott). Bipolar voltage maps were analyzed to search for low voltage areas (LVA), the following electrophysiological phenomena were assessed: (1) slow conduction corridors, and (2) lines of block. EGMs were characterized to search for fractionation. Electrical characteristics were compared between atria and between paroxysmal versus persistent AF patients. RESULTS: In the RA, LVAs were present in 60% of patients with paroxysmal AF and 100% of patients with persistent AF. In the LA, LVAs were present in 40% of patients with paroxysmal AF and 66% of patients with persistent AF. The areas of LVA in the RA and LA were 4.8±7.3 cm2 and 7.8±13.6 cm2 in patients with paroxysmal AF versus 11.7±3.0 cm2 and 2.1±1.8 cm2 in patients with persistent AF. In the RA, slow conduction corridors were present in 40.0% (paroxysmal AF) versus 66.7% (persistent AF) whereas in the LA, slow conduction corridors occurred in 20.0% versus 33.3% respectively (p = ns). EGM analysis showed more fractionation in persistent AF patients than paroxysmal (RA: persistent AF 10.8 vs. paroxysmal AF 4.7%, p = .036, LA: 10.3 vs. 4.1%, p = .108). CONCLUSION: Bi-atrial involvement is present in patients with paroxysmal and persistent AF. This is expressed by low voltage areas and slow conduction corridors whose extension progresses as the arrhythmia becomes persistent. This electrophysiological substrate demonstrates the important interplay with the pulmonary vein triggers to constitute the substrate for persistent arrhythmia.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía
9.
Pacing Clin Electrophysiol ; 45(5): 658-665, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35417049

RESUMEN

BACKGROUND: With an increasing number of cardiac implantable electronic devices (CIEDs), there has been a paralleled increase in demand for transvenous lead extraction (TLE). Cardiac surgeons (CS) and cardiologists perform TLE; however, data comparing the two groups of operators is scarce. OBJECTIVE: We compared the outcomes of TLE performed by cardiologists and CS from six European lead extraction units. METHOD: Data was collected retrospectively of 2205 patients who had 3849 leads extracted (PROMET) between 2005 and 2018. Patient demographics and procedural outcomes were compared between the CS and cardiologist groups, using propensity score matching. A multivariate regression analysis was also performed for variables associated with 30-day mortality. RESULTS: CS performed the majority of extractions (59.8%), of leads with longer dwell times (90 [57-129 interquartile range (IQR)] vs. 62 [31-102 IQR] months, CS vs. cardiologists, p < .001) and with pre-dominantly non-infectious indications (57.4% vs. 50.2%, CS vs. cardiologists, p < .001). CS achieved a higher complete success per lead than the cardiologists (98.1% vs. 95.7%, respectively, p < .01), with a higher number of minor complications (5.51% vs. 2.1%, p < .01) and similar number of major complications (0.47% vs. 1.3%, p = .12). Thirty-day mortality was similarly low in the CS and cardiologist groups (1.76% vs. 0.94%, p = .21). Unmatched data multivariate analysis revealed infection indication (OR 6.12 [1.9-20.3], p < .01), procedure duration (OR 1.01 [1.01-1.02], p < .01) and CS operator (OR 2.67, [1.12-6.37], p = .027) were associated with 30-day mortality. CONCLUSION: TLE by CS was performed with similar safety and higher efficacy compared to cardiologists in high and medium-volume lead extraction centers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Remoción de Dispositivos/métodos , Humanos , Prometazina , Estudios Retrospectivos , Resultado del Tratamiento
10.
Pacing Clin Electrophysiol ; 45(1): 23-34, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34841552

RESUMEN

BACKGROUND: Left atrial appendage (LAA) thrombosis increases the risk of stroke and its management has to be assessed. The aim of the present study is to evaluate short and long-term safety and efficacy of a standardized approach of percutaneous LAA closure (LAAC) routinely using a cerebral protection device (CPD) in patients with LAA thrombosis or sludge (LAAT). METHODS: We prospectively enrolled 14 consecutive patients with atrial fibrillation complicated by LAAT presenting in a high-volume tertiary center. In seven patients (50%) LAAT was found after anticoagulant withdrawal for severe bleedings and in the remaining half LAAT was found despite appropriate anticoagulant therapy. All patients were treated with a standardized interventional approach of LAAC routinely using a CPD and guided by transoesophageal echocardiography. RESULTS: Mean age was 68 ± 14 years and nine patients (64%) were male. Mean CHA2 DS2 -VASc and HAS-BLED scores were 3.3 ± 1.6 and 2.3 ± 1.1, respectively. Six patients (42.8%) presented organized thrombi while eight LAA sludge (57.1%). In 13 patients (92.8%) CPD was positioned through a right radial arterial access. Procedural success was achieved in all patients. In one patient we assisted to embolization of the thrombus during deployment of the device in the absence of neurological consequences. During a mean follow up of 426 ± 307 days, one patient died for non-cardiac cause while no embolic event or major bleeding were reported. CONCLUSION: In an unselected cohort, LAAC with the systematic use of CPD was a feasible, safe and effective therapeutic option for LAAT both acutely and after long-term follow-up.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos , Dispositivos de Protección Embólica , Accidente Cerebrovascular/prevención & control , Trombosis/cirugía , Anciano , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Estudios Prospectivos , Dispositivo Oclusor Septal
11.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36676690

RESUMEN

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Bradicardia/terapia , Fibrilación Atrial/terapia , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 97(3): 511-515, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32808741

RESUMEN

BACKGROUND: Presence of thrombus in the left atrial appendage (LAA) remains a severe contraindication to the percutaneous left atrial appendage closure procedure (LAAC), due to increased embolic risk. Recently, the experience developed in cerebral protection device in transcatheter aortic valve implantation (TAVI) procedure was translated in LAAC to address this issue. AIM: To evaluate efficacy and safety of Sentinel cerebral protection system (CPS) in supporting LAAC in real-world patient with persistent LAA thrombus. METHODS AND RESULTS: The study retrospectively enrolled consecutive patients with non-valvular atrial fibrillation (NVAF) and thrombus in LAA who underwent LAAC supported by Sentinel CPS in seven European high-volume centres. Twenty-seven patients were included with a median age of 69.1 ± 9.7 years old, with median CHA2 DS2 -VASc and HAS-BLEED scores 3 [2-5] and 3 [2.75-4], respectively. Technical and procedural success was achieved in all patients. No periprocedural TIA, stroke, or supra-aortic trunks dissection was recorded. CONCLUSIONS: In this multicenter registry, LAAC supported by Sentinel CPS in patients with LAA persistent thrombus seems to be a safe and efficacious treatment.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Trombosis/diagnóstico por imagen , Trombosis/etiología , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 97(7): E1019-E1024, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33417282

RESUMEN

BACKGROUND: In this analysis of the EWOLUTION registry, we evaluated the incidence, relevance and predictors of device-related thrombus in a large multi-center real-world cohort undergoing LAAc with the WATCHMAN device. METHODS AND RESULTS: We analyzed the 835 patients who underwent percutaneous LAA closure with the WATCHMAN device in the EWOLUTION registry in whom at least one TEE follow up was performed. Patients were 74 ± 9 y/o and were at high risk for stroke and bleeding (CHA2DS2-VASC-Score 4.3 ± 1.7; HAS-BLED-Score 2.3 ± 1.2). Device-related thrombus was detected in 4.1% (34/835) after a median of 54 days (IQR 42-111 days) with 91.2% (31/34) being detected within 3 months after the procedure or at the time of first TEE. Hereby DRT occurred irrespective of postprocedural anticoagulation. Patients with DRT more frequently had long-standing, non-paroxysmal atrial fibrillation (82.4 vs. 64.9%, p < .01), evidence of dense spontaneous echo contrast (26.5 vs. 11.9%, p = .03) and larger LAA diameters at the ostium (22.8 ± 3.5 vs. 21.1 ± 3.5 mm, p < .01) compared to patients without DRT. Left ventricular ejection fraction, device compression ratio and the incidence of renal dysfunction did not differ between the two groups. In a multivariate analysis, only non-paroxysmal atrial fibrillation identified as an independent predictor of developing DRT. Specific treatment of DRT was initiated in 62% (21/34) of patients whereas resolution was confirmed in 86% (18/21) of cases. Overall, no significant differences in annual rates of stroke/TIA or systemic embolism were observed in patients with or without DRT (DRT 1.7 vs. No-DRT 2.2%/year, p = .8). CONCLUSIONS: In real-world patients undergoing LAAc with the WATCHMAN device, DRT is rare. DRT was most frequently detected within the first 3 months after LAAc regardless of post-procedural regimen and was not associated with an increased risk of stroke or SE. While long-standing atrial fibrillation was the only independent factor associated with DRT, medical treatment of DRT resulted in a resolution of thrombi in most cases.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Humanos , Incidencia , Sistema de Registros , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Volumen Sistólico , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Trombosis/etiología , Resultado del Tratamiento , Función Ventricular Izquierda
14.
Europace ; 23(2): 238-246, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33279979

RESUMEN

AIMS: Left atrial appendage occlusion (LAAO) may be considered for patients with non-valvular atrial fibrillation (NVAF) and a relative/formal contraindication to anticoagulation. This study aimed to summarize the impact of aging on LAAO outcomes at short and long-term follow-up. METHODS AND RESULTS: We compared subjects aged <70, ≥70 and <80, and ≥80 years old in the prospective, multicentre Amplatzer™ Amulet™ Occluder Observational Study (Abbott, Plymouth, MN, USA). Serious adverse events (SAEs) were reported from implant through a 2-year post-LAAO visit and adjudicated by an independent clinical events committee. Overall, 1088 subjects were prospectively enrolled. There were 265 subjects (24.4%) <70 years old, 491 subjects (45.1%) ≥70 and <80 years old, and 332 subjects (30.5%) ≥80 years old, with the majority (≥80%) being contraindicated to anticoagulation. As expected, CHA2DS2-VASc and HAS-BLED Scores increased with age. Implant success was high (≥98.5%) across all groups, and the proportion of subjects with a procedure- or device-related SAE was similar between groups. At follow-up, the observed ischaemic stroke rate was not significantly different between groups, and corresponding risk reductions were 62, 56, and 85% when compared with predicted rates for subjects <70, ≥70 and <80, and ≥80 years old, respectively. Major bleeding and mortality rates increased with age, while the incidence of device-related thrombus tended to increase with age. CONCLUSIONS: Despite the increased risk for ischaemic stroke with increasing age in AF patients, LAAO reduced the risk for ischaemic stroke compared with the predicted rate across all age groups without differences in procedural SAEs.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Humanos , Estudios Prospectivos , Dispositivo Oclusor Septal/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
15.
Pacing Clin Electrophysiol ; 44(9): 1540-1548, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34235772

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) therapy contributes to an improvement in morbidity and mortality across all patient demographics. Patient age is a recognized risk factor for unfavorable outcomes in invasive procedures. This is the largest series of non-laser transvenous lead extraction (TLE) evaluating the association between patient age and procedure outcomes. METHODS: Data of 2205 (3849 leads) patients was collected retrospectively from six European TLE centers between January 2005-December 2018 in the PROMET study. Of these, 153 patients with 319 leads were excluded for incomplete data. A comparison of outcomes was performed between the age groups young [< 50 years], young intermediate [50-69 years], older intermediate [70-79 years], and octogenarian [≥80 years]. RESULTS: Infection was most common indication for TLE in the octogenarian cohort, less common in the younger population (60.1% vs. 33.2%, respectively, p < .01). High-voltage leads were extracted most frequently from young patients, less frequently from octogenarians (31.6% vs. 10%, p < .001), while the opposite was evident for pacemaker leads (p < .001). Rotational sheath use was equally prevalent across all patient groups (p = .79). Minor and major complications across all the age groups were statistically similar, as was procedural success; the 30-day mortality was most significant in the octogenarian and least in the young patients (4.9% vs. 0.4%, p = .005). Propensity matching multivariate analysis found systemic infection, lead dwell time, and patient age (p = .013, OR 1.064 [1.013-1.116]) increased risk of 30-day mortality. CONCLUSION: TLE is safe and effective across all age groups. 30-day mortality risk is significantly higher in the older patients.


Asunto(s)
Remoción de Dispositivos/métodos , Electrodos Implantados , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
16.
Europace ; 22(12): 1841-1847, 2020 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-32995866

RESUMEN

AIMS: To chart the effect of the COVID-19 pandemic on the activity of interventional electrophysiology services in affected regions. METHODS AND RESULTS: We reviewed the electrophysiology laboratory records in three affected cities: Wenzhou in China, Milan in Italy, and London in the UK. We inspected catheter lab records and interviewed electrophysiologists in each centre to gather information on the impact of the pandemic on working patterns and on the health of staff members and patients. There was a striking decline in interventional electrophysiology activity in each of the centres. The decline occurred within a week of the recognition of widespread community transmission of the virus in each region and shows a striking correlation with the national figures for new diagnoses of COVID-19 in each case. During the period of restriction, workflow dropped to <5% of normal, consisting of emergency cases only. In two of three centres, electrophysiologists were redeployed to perform emergency work outside electrophysiology. Among the centres studied, only Wenzhou has seen a recovery from the restrictions in activity. Following an intense nationwide programme of public health interventions, local transmission of COVID-19 ceased to be detectable after 18 February allowing the electrophysiology service to resume with a strict testing regime for all patients. CONCLUSION: Interventional electrophysiology is vulnerable to closure in times of great social difficulty including the COVID-19 pandemic. Intense public health intervention can permit suppression of local disease transmission allowing resumption of some normal activity with stringent precautions.


Asunto(s)
COVID-19/epidemiología , Electrofisiología Cardíaca , Servicio de Cardiología en Hospital/organización & administración , Prueba de COVID-19 , China/epidemiología , Humanos , Italia/epidemiología , Londres/epidemiología , Pandemias , SARS-CoV-2 , Flujo de Trabajo
17.
Europace ; 22(4): 613-621, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32087025

RESUMEN

AIMS: A validated risk stratification schema for transvenous lead extraction (TLE) could improve the management of these procedures. We aimed to derive and validate a scoring system to efficiently predict the need for advanced tools to achieve TLE success. METHODS AND RESULTS: Between November 2013 and March 2018, 1960 leads were extracted in 973 consecutive TLE procedures in two national referral sites using a stepwise approach. A procedure was defined as advanced extraction if required the use of powered sheaths and/or snares. The study population was a posteriori 1:1 randomized in derivation and validation cohorts. In the derivation cohort, presence of more than two targeted leads (odds ratio [OR] 1.76, P = 0.049), 3-year-old (OR 3.04, P = 0.001), 5-year-old (OR 3.48, P < 0.001), 10-year-old (OR 3.58, P = 0.008) oldest lead, implantable cardioverter-defibrillator (OR 3.84, P < 0.001), and passive fixation lead (OR 1.91, P = 0.032) were selected by a stepwise procedure and constituted the MB score showing a C-statistics of 0.82. In the validation group, the MB score was significantly associated with the risk of advanced extraction (OR 2.40, 95% confidence interval 2.02-2.86, P < 0.001) and showed an increase in event rate with increasing score. A low value (threshold = 1) ensured 100% sensibility and 100% negative predictive value, while a high value (threshold = 5) allowed a specificity of 92.8% and a positive predictive value of 91.9%. CONCLUSION: In this study, we developed and tested a simple point-based scoring system able to efficiently identify patients at low and high risk of needing advanced tools during TLE procedures.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Niño , Preescolar , Remoción de Dispositivos , Falla de Equipo , Humanos , Estudios Retrospectivos , Medición de Riesgo
18.
Europace ; 22(7): 1036-1043, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32464648

RESUMEN

AIMS: Evidence regarding post-procedural antithrombotic regimen other than used in randomized trials assessing percutaneous left atrial appendage (LAA) closure is limited. The present work aimed to compare different antithrombotic strategies applied in the real-world EWOLUTION study. METHODS AND RESULTS: A total of 998 patients with successful WATCHMAN implantation were available for the present analysis. The composite ischaemic endpoint of stroke, transitory ischaemic attack, systemic embolism and device thrombus, and the bleeding endpoint defined as at least major bleeding were assessed during an initial period (from implant until first medication change) and long-term period (from first change up to 2 years). The antithrombotic medication chosen in the initial phase was dual antiplatelet therapy (DAPT) in 60%, oral anticoagulation (OAC) in 27%, single antiplatelet therapy (SAPT) in 7%, and no medication in 6%. In the second long-term phase, SAPT was used in 65%, DAPT in 23%, no therapy in 8%, and OAC in 4%. No significant differences were found between the groups regarding the ischaemic endpoint both in the initial period (Kaplan-Meier estimated rate 2.9% for DAPT vs. 4.3% for OAC vs. 3.9% for SAPT or no therapy) and in the second period (4.2% for SAPT vs. 1.8% for DAPT vs. 3.5% for no therapy). With respect to bleeding events, the only difference was found in the initial phase with a higher incidence in patients under SAPT or no therapy. CONCLUSIONS: Tailored antithrombotic treatment using even very reduced strategies such as SAPT or no therapy showed no significant differences regarding ischaemic complications after LAA closure.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Fibrinolíticos , Anticoagulantes/uso terapéutico , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrinolíticos/uso terapéutico , Humanos , Resultado del Tratamiento
19.
Europace ; 22(7): 1103-1110, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32447388

RESUMEN

AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
20.
Heart Lung Circ ; 29(9): 1356-1365, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32299760

RESUMEN

BACKGROUND: In many genetic and acquired non-ischaemic cardiomyopathies (NICM) there have been frequent reports of involvement of the interventricular septum (IVS) by late gadolinium enhancement (LGE) at cardiac magnetic resonance (CMR). However, no studies have investigated the relationship between septal LGE and arrhythmias in different NICM subtypes. METHODS: This study enrolled 103 patients with septal LGE at baseline CMR and different NICM: hypertrophic (n=29) or lamin A/C gene (LMNA)-associated (n=23) cardiomyopathy, and acute (n=30) or previous (n=21) myocarditis. During follow-up, the occurrences of malignant ventricular arrhythmias (MVA) and major bradyarrhythmias (BA) were evaluated. RESULTS: At 4.9±0.7 years of follow-up, the occurrence of MVA and major BA in genetic vs acquired NICM were 10 of 52 vs 12 of 51, and 10 of 52 vs 4 of 51, respectively (both p=n.s.). However, MVA occurred more frequently in LMNA-NICM (eight of 23 vs two of 29 hypertrophic, p=0.015) and in previous myocarditis (nine of 21 vs three of 30 acute, p=0.016), while major BAs were particularly common in LMNA-NICM patients only (nine of 23 vs one of 29 hypertrophic, p=0.003). Different patterns of septal LGE were consistently retrospectively identified at baseline CMR: junctional and limited to the base in 79.3% of uneventful hypertrophic NICM; extended and focally transmural in LMNA-NICM with follow-up arrhythmias (both p<0.05); transitory in patients with acute myocarditis, who, differently from the post-myocarditis ones, showed follow-up arrhythmias only in the presence of unmodified LGE at follow-up CMR (five of 13, p=0.009). CONCLUSION: Septal LGE was significantly associated with MVA at the 5-year follow-up in LMNA-NICM or previous myocarditis, and with major BA in LMNA-NICM only. These differences correlated with heterogeneous patterns of IVS LGE in different NICM.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Cardiomiopatías/diagnóstico , Gadolinio/farmacología , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Función Ventricular Izquierda/fisiología , Tabique Interventricular/diagnóstico por imagen , Adulto , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Medios de Contraste/farmacología , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA