1.
J Appl Clin Med Phys ; 24(1): e13755, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35993318

RESUMEN

This study compared the reproducibility of chestwall and heart position using surface-guided versus RPM (real-time position management)-guided deep inspiration breath hold (DIBH) radiotherapy for left sided breast cancer. Forty DIBH patients under either surface-guided radiotherapy (SGRT) or RPM guidance were studied. For patients treated with tangential fields, reproducibility was measured as the displacements in central lung distance (CLD) and heart shadow to field edge distance (HFD) between pretreatment MV (megavoltage) images and planning DRRs (digitally reconstructed radiographs). For patients treated with volumetric modulated arc therapy (VMAT), sternum to isocenter (ISO) distance (StID), spine to rib edge distance (SpRD), and heart shadow to central axis (CAX) distance (HCD) between pretreatment kV images and planning DRRs were measured. These displacements were compared between SGRT and RPM-guided DIBH. In tangential patients, the mean absolute displacements of SGRT versus RPM guidance were 0.19 versus 0.23 cm in CLD, and 0.33 versus 0.62 cm in HFD. With respect to planning DRR, heart appeared closer to the field edge by 0.04 cm with surface imaging versus 0.62 cm with RPM. In VMAT patients, the displacements of surface imaging versus RPM guidance were 0.21 versus 0.15 cm in StID, 0.24 versus 0.19 cm in SpRD, and 0.72 versus 0.41 cm in HCD. Heart appeared 0.41 cm further away from CAX with surface imaging, whereas 0.10 cm closer to field CAX with RPM. None of the differences between surface imaging and RPM guidance was statistically significant. In conclusion, the displacements of chestwall were small and were comparable with SGRT- or RPM-guided DIBH. The position deviations of heart were larger than those of chestwall with SGRT or RPM. Although none of the differences between SGRT and RPM guidance were statistically significant, there was a trend that the position deviations of heart were smaller and more favorable with SGRT than with RPM guidance in tangential patients.


Asunto(s)
Neoplasias de la Mama , Pared Torácica , Neoplasias de Mama Unilaterales , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Reproducibilidad de los Resultados , Contencion de la Respiración , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de Mama Unilaterales/radioterapia , Corazón/diagnóstico por imagen
2.
J Appl Clin Med Phys ; 24(12): e14117, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37535396

RESUMEN

To compare the setup accuracy of optical surface image (OSI) versus orthogonal x-ray images (2DkV) using cone beam computed tomography (CBCT) as ground truth for radiotherapy of left breast cancer in deep-inspiration breath-hold (DIBH). Ten left breast DIBH patients treated with volumetric modulated arc therapy (VMAT) were studied retrospectively. OSI, 2DkV, and CBCT were acquired weekly at treatment setup. OSI, 2DkV, and CBCT were registered to planning CT or planning DRR based on a breast surface region of interest (ROI), bony anatomy (chestwall and sternum), and both bony anatomy and breast surface, respectively. These registrations provided couch shifts for each imaging system. The setup errors, or the difference in couch shifts between OSI and CBCT were compared to those between 2DkV and CBCT. A second OSI was acquired during last beam delivery to evaluate intrafraction motion. The median absolute setup errors were (0.21, 0.27, 0.23 cm, 0.6°, 1.3°, 1.0°) for OSI, and (0.26, 0.24, 0.18 cm, 0.9°, 1.0°, 0.6°) for 2DkV in vertical, longitudinal and lateral translations, and in rotation, roll and pitch, respectively. None of the setup errors was significantly different between OSI and 2DkV. For both systems, the systematic and random setup errors were ≤0.6 cm and ≤1.5° in all directions. Nevertheless, larger setup errors were observed in some sessions in both systems. There was no correlation between OSI and CBCT whereas there was modest correlation between 2DkV and CBCT. The intrafraction motion in DIBH detected by OSI was small with median absolute translations <0.2 cm, and rotations ≤0.4°. Though OSI showed comparable and small setup errors as 2DkV, it showed no correlation with CBCT. We concluded that to achieve accurate setup for both bony anatomy and breast surface, daily 2DkV can't be omitted following OSI for left breast patients treated with DIBH VMAT.


Asunto(s)
Neoplasias de la Mama , Radioterapia de Intensidad Modulada , Humanos , Femenino , Estudios Retrospectivos , Rayos X , Tomografía Computarizada de Haz Cónico/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Contencion de la Respiración
3.
J Appl Clin Med Phys ; 21(4): 51-58, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32196934

RESUMEN

PURPOSE: The plan check tool (PCT) is the result of a multi-institutional collaboration to jointly develop a flexible automated plan checking framework designed with the versatility to be shared across collaborating facilities while supporting the individual differences between practices. We analyze the effect that PCT has had on the efficiency and effectiveness of initial chart checks at our institution. METHODS AND MATERIALS: Data on errors identified during initial chart checks were acquired during two time periods: before the introduction of PCT in the clinic (6/24/2015 to 7/31/2015, 187 checks) and post-clinical release (4/14/2016 to 5/2/2016, 186 checks). During each time period, human plan checkers were asked to record all issues that they either manually detected or that were detected by PCT as well as the amount of time, less breaks, or interruptions, it took to check each plan. RESULTS: After the clinical release of PCT, there was a statistically significant decrease in the number of issues recorded by the human plan checkers both related to checks explicitly performed by PCT (13 vs 50, P < 0.001) and in issues identified overall (127 vs 200, P < 0.001). The mean and medium time for a plan check decreased by 20%. CONCLUSIONS: The use of a multi-institutional, configurable, automated plan checking tool has resulted in both substantial gains in efficiency and moving error detection to earlier points in the planning process, decreasing their likelihood that they reach the patient. The sizeable startup effort needed to create this tool from scratch was mitigated by the sharing, and subsequent co-development, of software code from a peer institution.


Asunto(s)
Errores Médicos/prevención & control , Seguridad del Paciente , Planificación de la Radioterapia Asistida por Computador/normas , Errores de Configuración en Radioterapia , Radioterapia/normas , Algoritmos , Lista de Verificación , Humanos , Cooperación Internacional , Garantía de la Calidad de Atención de Salud , Control de Calidad , Reproducibilidad de los Resultados , Programas Informáticos
4.
J Appl Clin Med Phys ; 17(3): 371-379, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27167294

RESUMEN

The presence of two intact lungs makes it challenging to reach a tumoricidal dose with hemithoracic pleural intensity-modulated radiation therapy (IMRT) in patients with malignant pleural mesothelioma (MPM) who underwent pleurectomy/decortications or have unresectable disease. We developed an anatomy-based model to predict attainable prescription dose before starting optimization. Fifty-six clinically delivered IMRT plans were analyzed regarding correlation of prescription dose and individual and total lung volumes, planning target volume (PTV), ipsilateral normal lung volume and ratios: contralateral/ipsilateral lung (CIVR); contralateral lung/PTV (CPVR); ipsilateral lung /PTV (IPVR); ipsilateral normal lung /total lung (INTLVR); ipsilateral normal lung/PTV (INLPVR). Spearman's rank correlation and Fisher's exact test were used. Correlation between mean ipsilateral lung dose (MILD) and these volume ratios and between prescription dose and single lung mean doses were studied. The prediction models were validated in 23 subsequent MPM patients. CIVR showed the strongest correlation with dose (R=0.603,p<0.001) and accurately predicted prescription dose in the validation cases. INLPVR and MILD as well as MILD and prescription dose were significantly correlated (R=-0.784,p<0.001 and R=0.554,p<0.001, respectively) in the training and validation cases. Parameters obtainable directly from planning scan anatomy predict achievable prescription doses for hemithoracic IMRT treatment of MPM patients with two intact lungs. PACS number(s): 87.55.de, 87.55.dk.


Asunto(s)
Pulmón/efectos de la radiación , Mesotelioma/radioterapia , Neoplasias Pleurales/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Humanos , Dosificación Radioterapéutica
5.
J Appl Clin Med Phys ; 16(3): 5431, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103502

RESUMEN

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States.The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner.Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.The following terms are used in the AAPM practice guidelines:Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline.Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.


Asunto(s)
Lista de Verificación/normas , Física Sanitaria/normas , Seguridad del Paciente/normas , Oncología por Radiación/normas , Administración de la Seguridad/normas , Sociedades/normas , Documentación/normas , Estados Unidos
6.
Pract Radiat Oncol ; 12(2): 163-169, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34670137

RESUMEN

PURPOSE: This study aimed to perform a longitudinal analysis of the performance of our automated plan checking software by retrospectively evaluating the number of errors identified in plans delivered to patients in 3, month-long, data collection periods between 2017 and 2020. METHODS AND MATERIALS: Eleven automated checks were retrospectively run on 1169 external beam radiation therapy treatment plans identified as meeting the following criteria: planning target volume-based multifield photon plans receiving a status of treatment approved in March 2017, March 2018, or March 2020. The number of passes (true positives) and flags were recorded. Flags were subcategorized into false negatives, false negatives due to naming conventions, and true negatives. In addition, 2 × 2 contingency tables using a 2-tailed Fisher's exact test were used to determine whether there were nonrandom associations between the output of the automated plan checking software and whether the check was manual or automated at the original time of treatment approval. RESULTS: A statistically significant decrease in flags between the pre- and postautomation data sets was observed for 4 contour-based checks, namely adjacent structures overlap, empty structures and missing slices, overlap between body and couch, and laterality, as well as a check that determined whether the plan's global maximum dose was within the planning target volume. A review of the origins of false negatives was fed back into the design of the checks to improve the reliability of the system and help avoid warning fatigue. CONCLUSIONS: Periodic and longitudinal review of the performance of automated software was essential for monitoring and understanding its impact on error rates, as well as for optimization of the tool to adapt to regular changes of clinical practice. The automated plan checking software has demonstrated continuous contributions to the safe and effective delivery of external beam radiation therapy to our patient population, an impact that extends beyond its initial implementation and deployment.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Programas Informáticos
7.
Med Phys ; 48(11): e927-e968, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34287961

RESUMEN

While most Radiation Oncology clinics have adopted electronic charting in one form or another, no consensus document exists that provides guidelines for safe and effective use of the Radiation Oncology electronic medical records (RO-EMR). Task Group 262 was formed to provide these guidelines as well as to provide recommendations to vendors for improving electronic charting functionality in future. Guidelines are provided in the following areas: Implementation and training for the RO-EMR, acceptance testing and quality assurance (QA) of the RO-EMR, use of the RO-EMR as an information repository, use of the RO-EMR as a workflow manager, electronic charting for brachytherapy and nonstandard treatments, and information technology (IT) considerations associated with the RO-EMR. The report was based on a literature search by the task group, an extensive survey of task group members on their respective RO-EMR practices, an AAPM membership survey on electronic charting, as well as group consensus.


Asunto(s)
Braquiterapia , Oncología por Radiación , Registros Electrónicos de Salud , Electrónica , Planificación de la Radioterapia Asistida por Computador , Informe de Investigación
8.
Adv Radiat Oncol ; 5(5): 1042-1050, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33083666

RESUMEN

PURPOSE: We report on the clinical performance of a fully automated approach to treatment planning based on a Pareto optimal, constrained hierarchical optimization algorithm, named Expedited Constrained Hierarchical Optimization (ECHO). METHODS AND MATERIALS: From April 2017 to October 2018, ECHO produced 640 treated plans for 523 patients who underwent stereotactic body radiation therapy (RT) for paraspinal and other metastatic tumors. A total of 182 plans were for 24 Gy in a single fraction, 387 plans were for 27 Gy in 3 fractions, and the remainder were for other prescriptions or fractionations. Of the plans, 84.5% were for paraspinal tumors, with 69, 302, and 170 in the cervical, thoracic, and lumbosacral spine, respectively. For each case, after contouring, a template plan using 9 intensity modulated RT fields based on disease site and tumor location was sent to ECHO through an application program interface plug-in from the treatment planning system. ECHO returned a plan that satisfied all critical structure hard constraints with optimal target volume coverage and the lowest achievable normal tissue doses. Upon ECHO completion, the planner received an e-mail indicating the plan was ready for review. The plan was accepted if all clinical criteria were met. Otherwise, a limited number of parameters could be adjusted for another ECHO run. RESULTS: The median planning target volume size was 84.3 cm3 (range, 6.9-633.2). The median time to produce 1 ECHO plan was 63.5 minutes (range, 11-340 minutes) and was largely dependent on the field sizes. Of the cases, 79.7% required 1 run to produce a clinically accepted plan, 13.3% required 1 additional run with minimal parameter adjustments, and 7.0% required ≥2 additional runs with significant parameter modifications. All plans met or bettered the institutional clinical criteria. CONCLUSIONS: We successfully implemented automated stereotactic body RT paraspinal and other metastatic tumors planning. ECHO produced high-quality plans, improved planning efficiency and robustness, and enabled expedited treatment planning at our clinic.

9.
JAMA Dermatol ; 156(9): 963-972, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32756880

RESUMEN

Importance: Persistent radiation-induced alopecia (pRIA) and its management have not been systematically described. Objective: To characterize pRIA in patients with primary central nervous system (CNS) tumors or head and neck sarcoma. Design, Setting, and Participants: A retrospective cohort study of patients from January 1, 2011, to January 30, 2019, was conducted at 2 large tertiary care hospitals and comprehensive cancer centers. Seventy-one children and adults diagnosed with primary CNS tumors or head and neck sarcomas were evaluated for pRIA. Main Outcomes and Measures: The clinical and trichoscopic features, scalp radiation dose-response relationship, and response to topical minoxidil were assessed using standardized clinical photographs of the scalp, trichoscopic images, and radiotherapy treatment plans. Results: Of the 71 patients included (median [range] age, 27 [4-75] years; 51 female [72%]), 64 (90%) had a CNS tumor and 7 (10%) had head and neck sarcoma. Alopecia severity was grade 1 in 40 of 70 patients (56%), with localized (29 of 54 [54%]), diffuse (13 of 54 [24%]), or mixed (12 of 54 [22%]) patterns. The median (range) estimated scalp radiation dose was 39.6 (15.1-50.0) Gy; higher dose (odds ratio [OR], 1.15; 95% CI, 1.04-1.28) and proton irradiation (OR, 5.7; 95% CI, 1.05-30.8) were associated with greater alopecia severity (P < .001), and the dose at which 50% of patients were estimated to have severe (grade 2) alopecia was 36.1 Gy (95% CI, 33.7-39.6 Gy). Predominant trichoscopic features included white patches (16 of 28 [57%]); in 15 patients, hair-shaft caliber negatively correlated with scalp dose (correlation coefficient, -0.624; P = .01). The association between hair density and scalp radiation dose was not statistically significant (-0.381; P = .16). Twenty-eight of 34 patients (82%) responded to topical minoxidil, 5% (median follow-up, 61 [interquartile range, 21-105] weeks); 4 of 25 (16%) topical minoxidil recipients with clinical images improved in severity grade. Two patients responded to hair transplantation and 1 patient responded to plastic surgical reconstruction. Conclusions and Relevance: Persistent radiation-induced alopecia among patients with primary CNS tumors or head and neck sarcomas represents a dose-dependent phenomenon that has distinctive clinical and trichoscopic features. The findings of this study suggest that topical minoxidil and procedural interventions may have benefit in the treatment of pRIA.


Asunto(s)
Alopecia/diagnóstico , Irradiación Craneana/efectos adversos , Minoxidil/administración & dosificación , Traumatismos por Radiación/diagnóstico , Cuero Cabelludo/cirugía , Administración Tópica , Adolescente , Adulto , Anciano , Alopecia/etiología , Alopecia/terapia , Neoplasias del Sistema Nervioso Central/radioterapia , Niño , Preescolar , Relación Dosis-Respuesta en la Radiación , Femenino , Cabello/efectos de la radiación , Cabello/trasplante , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Masculino , Persona de Mediana Edad , Traumatismos por Radiación/etiología , Traumatismos por Radiación/terapia , Estudios Retrospectivos , Cuero Cabelludo/efectos de la radiación , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Adulto Joven
10.
Med Phys ; 47(6): e236-e272, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31967655

RESUMEN

BACKGROUND: While the review of radiotherapy treatment plans and charts by a medical physicist is a key component of safe, high-quality care, very few specific recommendations currently exist for this task. AIMS: The goal of TG-275 is to provide practical, evidence-based recommendations on physics plan and chart review for radiation therapy. While this report is aimed mainly at medical physicists, others may benefit including dosimetrists, radiation therapists, physicians and other professionals interested in quality management. METHODS: The scope of the report includes photon/electron external beam radiotherapy (EBRT), proton radiotherapy, as well as high-dose rate (HDR) brachytherapy for gynecological applications (currently the highest volume brachytherapy service in most practices). The following review time points are considered: initial review prior to treatment, weekly review, and end-of-treatment review. The Task Group takes a risk-informed approach to developing recommendations. A failure mode and effects analysis was performed to determine the highest-risk aspects of each process. In the case of photon/electron EBRT, a survey of all American Association of Physicists in Medicine (AAPM) members was also conducted to determine current practices. A draft of this report was provided to the full AAPM membership for comment through a 3-week open-comment period, and the report was revised in response to these comments. RESULTS: The highest-risk failure modes included 112 failure modes in photon/electron EBRT initial review, 55 in weekly and end-of-treatment review, 24 for initial review specific to proton therapy, and 48 in HDR brachytherapy. A 103-question survey on current practices was released to all AAPM members who self-reported as working in the radiation oncology field. The response rate was 33%. The survey data and risk data were used to inform recommendations. DISCUSSION: Tables of recommended checks are presented and recommendations for best practice are discussed. Suggestions to software vendors are also provided. CONCLUSIONS: TG-275 provides specific recommendations for physics plan and chart review which should enhance the safety and quality of care for patients receiving radiation treatments.


Asunto(s)
Braquiterapia , Oncología por Radiación , Humanos , Fotones , Física , Planificación de la Radioterapia Asistida por Computador , Estados Unidos
11.
Med Phys ; 36(11): 5359-73, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19994544

RESUMEN

AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit = /mean/ + 1.96sigma. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.


Asunto(s)
Radiometría , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada/normas , Dosimetría por Película , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Masculino , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Garantía de la Calidad de Atención de Salud
12.
Med Dosim ; 44(2): 150-154, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29801668

RESUMEN

Locally advanced breast cancer patients with expander or implant reconstructions who require comprehensive postmastectomy radiotherapy (PMRT) can pose unique treatment planning challenges. Traditional 3D conformal radiation techniques often result in large dose inhomogeneity throughout the treatment volumes, inadequate target coverage, or excessive normal tissue doses. We have developed a volumetric modulated arc therapy (VMAT) planning technique without entering through the ipsilateral arm that produced adequate target volume coverage, excellent homogeneity throughout the target volume, and acceptable doses to the normal structures. Twenty left-sided and 10 right-sided patients with either ipsilateral or bilateral permanent implants or tissue expanders who received comprehensive PMRT between October 2014 and February 2016 were included in this study. Ten left-sided cases used deep inspiration breath hold (DIBH) technique, and others used free breathing (FB). Planning target volume (PTV) included chestwall, internal mammary nodes (IMNs), supraclavicular, and axillary lymph nodes. A VMAT plan using 4 or 5 partial arcs with 6 MV photon beam avoiding entering through the ipsilateral arm was generated for each patient. Prescription dose was 50 Gy in 25 fractions. PTV coverage, maximum depth of IMNs, dose homogeneity and dose to the heart, lungs, thyroid, contralateral intact breast or implant, liver, stomach, left anterior descending artery, ipsilateral brachial plexus, esophagus, spinal cord, and total MU were evaluated. PTV D95% (Gy) was 49.6 ± 0.9, 48.7 ± 0.9, and 49.5 ± 1.1; PTV D05% (Gy) was 55.7 ± 0.6, 55.1 ± 1.4, and 55.0 ± 0.7; maximum depth of IMNs (cm) was 4.3 ± 0.9, 4.6 ± 1.1, and 4.9 ± 2.3; ipsilateral lung, V20Gy (%) was 29.0 ± 2.1, 28.8 ± 2.5, and 27.5 ± 3.4; heart mean dose (Gy) was 4.2 ± 0.4, 7.5 ± 1.1, and 6.6 ± 0.8 for right-sided FB, left-sided FB, and left-sided DIBH cases, respectively. D95% of IMNs all received 100% prescription dose. The maximum dose (Gy) to the left anterior descending artery was 33.8 ± 11.7 for left-sided FB and 31.4 ± 7.3 for left-sided DIBH. VMAT technique avoiding ipsilateral arm can produce acceptable clinical plans for locally advanced breast cancer patients with expander or implant reconstructions receiving comprehensive PMRT.


Asunto(s)
Implantes de Mama , Neoplasias de la Mama/radioterapia , Mamoplastia , Mastectomía , Radioterapia de Intensidad Modulada/métodos , Dispositivos de Expansión Tisular , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Dosificación Radioterapéutica , Radioterapia Adyuvante , Estudios Retrospectivos
13.
Med Phys ; 46(7): 2944-2954, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31055858

RESUMEN

PURPOSE: To develop and implement a fully automated approach to intensity modulated radiation therapy (IMRT) treatment planning. METHOD: The optimization algorithm is developed based on a hierarchical constrained optimization technique and is referred internally at our institution as expedited constrained hierarchical optimization (ECHO). Beamlet contributions to regions-of-interest are precomputed and captured in the influence matrix. Planning goals are of two classes: hard constraints that are strictly enforced from the first step (e.g., maximum dose to spinal cord), and desirable goals that are sequentially introduced in three constrained optimization problems (better planning target volume (PTV) coverage, lower organ at risk (OAR) doses, and smoother fluence map). After solving the optimization problems using external commercial optimization engines, the optimal fluence map is imported into an FDA-approved treatment planning system (TPS) for leaf sequencing and accurate full dose calculation. The dose-discrepancy between the optimization and TPS dose calculation is then calculated and incorporated into optimization by a novel dose correction loop technique using Lagrange multipliers. The correction loop incorporates the leaf sequencing and scattering effects into optimization to improve the plan quality and reduce the calculation time. The resultant optimal fluence map is again imported into TPS for leaf sequencing and final dose calculation for plan evaluation and delivery. The workflow is automated using application program interface (API) scripting, requiring user interaction solely to prepare the contours and beam arrangement prior to launching the ECHO plug-in from the TPS. For each site, parameters and objective functions are chosen to represent clinical priorities. The first site chosen for clinical implementation was metastatic paraspinal lesions treated with stereotactic body radiotherapy (SBRT). As a first step, 75 ECHO paraspinal plans were generated retrospectively and compared with clinically treated plans generated by planners using VMAT (volumetric modulated arc therapy) with 4 to 6 partial arcs. Subsequently, clinical deployment began in April, 2017. RESULTS: In retrospective study, ECHO plans were found to be dosimetrically superior with respect to tumor coverage, plan conformity, and OAR sparing. For example, the average PTV D95%, cord and esophagus max doses, and Paddick Conformity Index were improved, respectively, by 1%, 6%, 14%, and 15%, at a negligible 3% cost of the average skin D10cc dose. CONCLUSION: Hierarchical constrained optimization is a powerful and flexible tool for automated IMRT treatment planning. The dosimetric correction step accurately accounts for detailed dosimetric multileaf collimator and scattering effects. The system produces high-quality, Pareto optimal plans and avoids the time-consuming trial-and-error planning process.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada , Automatización , Modelos Teóricos , Factores de Tiempo
14.
Int J Radiat Oncol Biol Phys ; 70(4): 1100-7, 2008 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-17980501

RESUMEN

PURPOSE: Unknown primary head and neck cancers often require comprehensive mucosal and bilateral neck irradiation. With conventional techniques, significant toxicity can develop. Intensity-modulated radiotherapy (IMRT) has the potential to minimize the toxicity. METHODS AND MATERIALS: Between 2000 and 2005, 21 patients underwent IMRT for unknown primary head and neck cancer at our center. Of the 21 patients, 5 received IMRT with definitive intent and 16 as postoperative therapy; 14 received concurrent chemotherapy and 7 IMRT alone. The target volumes included the bilateral neck and mucosal surface. The median dose was 66 Gy. Acute and chronic toxicities, esophageal strictures, and percutaneous endoscopic gastrostomy tube dependence were evaluated. Progression-free survival, regional progression-free survival, distant metastasis-free survival, and overall survival were estimated with Kaplan-Meier curves. RESULTS: With a median follow-up of 24 months, the 2-year regional progression-free survival, distant metastasis-free survival, and overall survival rate was 90%, 90%, and 85%, respectively. Acute grade 1 and 2 xerostomia was seen in 57% and 43% of patients, respectively. Salivary function improved with time. Percutaneous endoscopic gastrostomy tube placement was required in 72% with combined modality treatment and 43% with IMRT alone. Only 1 patient required percutaneous endoscopic gastrostomy support at the last follow-up visit. Two patients treated with combined modality and one treated with IMRT alone developed esophageal strictures, but all had improvement or resolution with dilation. CONCLUSION: The preliminary analysis of IMRT for unknown primary head and neck cancer has shown acceptable toxicity and encouraging efficacy. The analysis of the dosimetric variables showed excellent tumor coverage and acceptable doses to critical normal structures. Esophageal strictures developed but were effectively treated with dilation. Techniques to limit the esophageal dose could help further minimize this complication.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias Primarias Desconocidas/radioterapia , Radioterapia de Intensidad Modulada , Adulto , Anciano , Anciano de 80 o más Años , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Carboplatino/administración & dosificación , Carcinoma de Células Escamosas/tratamiento farmacológico , Carcinoma de Células Escamosas/cirugía , Cisplatino/administración & dosificación , Terapia Combinada/métodos , Supervivencia sin Enfermedad , Femenino , Fluorouracilo/administración & dosificación , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Primarias Desconocidas/tratamiento farmacológico , Traumatismos por Radiación/etiología , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/efectos adversos
15.
Int J Radiat Oncol Biol Phys ; 70(1): 2-13, 2008 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-17869020

RESUMEN

PURPOSE: Hypoxia renders tumor cells radioresistant, limiting locoregional control from radiotherapy (RT). Intensity-modulated RT (IMRT) allows for targeting of the gross tumor volume (GTV) and can potentially deliver a greater dose to hypoxic subvolumes (GTV(h)) while sparing normal tissues. A Monte Carlo model has shown that boosting the GTV(h) increases the tumor control probability. This study examined the feasibility of fluorine-18-labeled fluoromisonidazole positron emission tomography/computed tomography ((18)F-FMISO PET/CT)-guided IMRT with the goal of maximally escalating the dose to radioresistant hypoxic zones in a cohort of head and neck cancer (HNC) patients. METHODS AND MATERIALS: (18)F-FMISO was administered intravenously for PET imaging. The CT simulation, fluorodeoxyglucose PET/CT, and (18)F-FMISO PET/CT scans were co-registered using the same immobilization methods. The tumor boundaries were defined by clinical examination and available imaging studies, including fluorodeoxyglucose PET/CT. Regions of elevated (18)F-FMISO uptake within the fluorodeoxyglucose PET/CT GTV were targeted for an IMRT boost. Additional targets and/or normal structures were contoured or transferred to treatment planning to generate (18)F-FMISO PET/CT-guided IMRT plans. RESULTS: The heterogeneous distribution of (18)F-FMISO within the GTV demonstrated variable levels of hypoxia within the tumor. Plans directed at performing (18)F-FMISO PET/CT-guided IMRT for 10 HNC patients achieved 84 Gy to the GTV(h) and 70 Gy to the GTV, without exceeding the normal tissue tolerance. We also attempted to deliver 105 Gy to the GTV(h) for 2 patients and were successful in 1, with normal tissue sparing. CONCLUSION: It was feasible to dose escalate the GTV(h) to 84 Gy in all 10 patients and in 1 patient to 105 Gy without exceeding the normal tissue tolerance. This information has provided important data for subsequent hypoxia-guided IMRT trials with the goal of further improving locoregional control in HNC patients.


Asunto(s)
Hipoxia de la Célula , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/radioterapia , Misonidazol/análogos & derivados , Radiofármacos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Estudios de Factibilidad , Fluorodesoxiglucosa F18/farmacocinética , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/patología , Humanos , Masculino , Persona de Mediana Edad , Misonidazol/farmacocinética , Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Fármacos Sensibilizantes a Radiaciones/farmacocinética , Radiofármacos/farmacocinética , Dosificación Radioterapéutica
16.
Pract Radiat Oncol ; 8(4): 279-286, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29429922

RESUMEN

INTRODUCTION: An electronic checklist has been designed with the intention of reducing errors while minimizing user effort in completing the checklist. We analyze the clinical use and evolution of the checklist over the past 5 years and review data in an incident learning system (ILS) to investigate whether it has contributed to an improvement in patient safety. METHODS AND MATERIALS: The checklist is written as a standalone HTML application using VBScript. User selection of pertinent demographic details limits the display of checklist items only to those necessary for the particular clinical scenario. Ten common clinical scenarios were used to illustrate the difference between the maximum possible number of checklist items available in the code versus the number displayed to the user at any one time. An ILS database of errors and near misses was reviewed to evaluate whether the checklist influenced the occurrence of reported events. RESULTS: Over 5 years, the number of checklist items available in the code nearly doubled, whereas the number displayed to the user at any one time stayed constant. Events reported in our ILS related to the beam energy used with pacemakers, projection of anatomy on digitally reconstructed radiographs, orthogonality of setup fields, and field extension beyond match lines, did not recur after the items were added to the checklist. Other events related to bolus documentation and breakpoints continued to be reported. CONCLUSION: Our checklist is adaptable to the introduction of new technologies, transitions between planning systems, and to errors and near misses recorded in the ILS. The electronic format allows us to restrict user display to a small, relevant, subset of possible checklist items, limiting the planner effort needed to review and complete the checklist.


Asunto(s)
Lista de Verificación , Garantía de la Calidad de Atención de Salud , Radioterapia/normas , Programas Informáticos , Bases de Datos Factuales , Instituciones de Salud , Humanos , Radioterapia/métodos , Planificación de la Radioterapia Asistida por Computador/normas
17.
Phys Med Biol ; 63(14): 145020, 2018 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-29911659

RESUMEN

We proposed a framework to detect and quantify local tumor morphological changes due to chemo-radiotherapy (CRT) using a Jacobian map and to extract quantitative radiomic features from the Jacobian map to predict the pathologic tumor response in locally advanced esophageal cancer patients. In 20 patients who underwent CRT, a multi-resolution BSpline deformable registration was performed to register the follow-up (post-CRT) CT to the baseline CT image. The Jacobian map (J) was computed as the determinant of the gradient of the deformation vector field. The Jacobian map measured the ratio of local tumor volume change where J < 1 indicated tumor shrinkage and J > 1 denoted expansion. The tumor was manually delineated and corresponding anatomical landmarks were generated on the baseline and follow-up images. Intensity, texture and geometry features were then extracted from the Jacobian map of the tumor to quantify tumor morphological changes. The importance of each Jacobian feature in predicting pathologic tumor response was evaluated by both univariate and multivariate analysis. We constructed a multivariate prediction model by using a support vector machine (SVM) classifier coupled with a least absolute shrinkage and selection operator (LASSO) for feature selection. The SVM-LASSO model was evaluated using ten-times repeated 10-fold cross-validation (10 × 10-fold CV). After registration, the average target registration error was 4.30 ± 1.09 mm (LR:1.63 mm AP:1.59 mm SI:3.05 mm) indicating registration error was within two voxels and close to 4 mm slice thickness. Visually, the Jacobian map showed smoothly-varying local shrinkage and expansion regions in a tumor. Quantitatively, the average median Jacobian was 0.80 ± 0.10 and 1.05 ± 0.15 for responder and non-responder tumors, respectively. These indicated that on average responder tumors had 20% median volume shrinkage while non-responder tumors had 5% median volume expansion. In univariate analysis, the minimum Jacobian (p = 0.009, AUC = 0.98) and median Jacobian (p = 0.004, AUC = 0.95) were the most significant predictors. The SVM-LASSO model achieved the highest accuracy when these two features were selected (sensitivity = 94.4%, specificity = 91.8%, AUC = 0.94). Novel features extracted from the Jacobian map quantified local tumor morphological changes using only baseline tumor contour without post-treatment tumor segmentation. The SVM-LASSO model using the median Jacobian and minimum Jacobian achieved high accuracy in predicting pathologic tumor response. The Jacobian map showed great potential for longitudinal evaluation of tumor response.


Asunto(s)
Quimioradioterapia/métodos , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/patología , Esofagectomía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Terapia Combinada , Neoplasias Esofágicas/terapia , Humanos , Estudios Retrospectivos , Máquina de Vectores de Soporte , Carga Tumoral
18.
Int J Med Phys Clin Eng Radiat Oncol ; 7(3): 330-338, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31131158

RESUMEN

Normal lung CT texture features have been used for the prediction of radiation-induced lung disease (RILD). For these features to be clinically useful, they should be robust to tumor size variations and not correlated with the normal lung volume of interest, i.e., the volume of the peri-tumoral region (PTR). CT images of 14 lung cancer patients were studied. Different sizes of gross tumor volumes (GTVs) were simulated and placed in the lung contralateral to the tumor. 27 texture features [nine from intensity histogram, eight from the gray-level co-occurrence matrix (GLCM) and ten from the gray-level run-length matrix (GLRM)] were extracted from the PTR. The Bland-Altman analysis was applied to measure the normalized range of agreement (nRoA) for each feature when GTV size varied. A feature was considered as robust when its nRoA was less than the threshold (100%). Sixteen texture features were identified as robust. None of the robust features was correlated with the volume of the PTR. No feature showed statistically significant differences (P<0.05) on GTV locations. We identified 16 robust normal lung CT texture features that can be further examined for the prediction of RILD.

19.
Med Phys ; 45(4): 1537-1549, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29457229

RESUMEN

PURPOSE: To develop a radiomics prediction model to improve pulmonary nodule (PN) classification in low-dose CT. To compare the model with the American College of Radiology (ACR) Lung CT Screening Reporting and Data System (Lung-RADS) for early detection of lung cancer. METHODS: We examined a set of 72 PNs (31 benign and 41 malignant) from the Lung Image Database Consortium image collection (LIDC-IDRI). One hundred three CT radiomic features were extracted from each PN. Before the model building process, distinctive features were identified using a hierarchical clustering method. We then constructed a prediction model by using a support vector machine (SVM) classifier coupled with a least absolute shrinkage and selection operator (LASSO). A tenfold cross-validation (CV) was repeated ten times (10 × 10-fold CV) to evaluate the accuracy of the SVM-LASSO model. Finally, the best model from the 10 × 10-fold CV was further evaluated using 20 × 5- and 50 × 2-fold CVs. RESULTS: The best SVM-LASSO model consisted of only two features: the bounding box anterior-posterior dimension (BB_AP) and the standard deviation of inverse difference moment (SD_IDM). The BB_AP measured the extension of a PN in the anterior-posterior direction and was highly correlated (r = 0.94) with the PN size. The SD_IDM was a texture feature that measured the directional variation of the local homogeneity feature IDM. Univariate analysis showed that both features were statistically significant and discriminative (P = 0.00013 and 0.000038, respectively). PNs with larger BB_AP or smaller SD_IDM were more likely malignant. The 10 × 10-fold CV of the best SVM model using the two features achieved an accuracy of 84.6% and 0.89 AUC. By comparison, Lung-RADS achieved an accuracy of 72.2% and 0.77 AUC using four features (size, type, calcification, and spiculation). The prediction improvement of SVM-LASSO comparing to Lung-RADS was statistically significant (McNemar's test P = 0.026). Lung-RADS misclassified 19 cases because it was mainly based on PN size, whereas the SVM-LASSO model correctly classified 10 of these cases by combining a size (BB_AP) feature and a texture (SD_IDM) feature. The performance of the SVM-LASSO model was stable when leaving more patients out with five- and twofold CVs (accuracy 84.1% and 81.6%, respectively). CONCLUSION: We developed an SVM-LASSO model to predict malignancy of PNs with two CT radiomic features. We demonstrated that the model achieved an accuracy of 84.6%, which was 12.4% higher than Lung-RADS.


Asunto(s)
Detección Precoz del Cáncer , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X , Máquina de Vectores de Soporte
20.
Int J Radiat Oncol Biol Phys ; 69(2): 459-68, 2007 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-17493769

RESUMEN

PURPOSE: To perform a retrospective review of laryngeal/hypopharyngeal carcinomas treated with concurrent chemotherapy and intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS: Between January 2002 and June 2005, 20 laryngeal and 11 hypopharyngeal carcinoma patients underwent IMRT with concurrent platinum-based chemotherapy; most patients had Stage IV disease. The prescription of the planning target volume for gross, high-risk, and low-risk subclinical disease was 70, 59.4, and 54 Gy, respectively. Acute/late toxicities were retrospectively scored using the Common Toxicity Criteria scale. The 2-year local progression-free, regional progression-free, laryngectomy-free, distant metastasis-free, and overall survival rates were calculated using the Kaplan-Meier method. RESULTS: The median follow-up of the living patients was 26 months (range, 17-58 months). The 2-year local progression-free, regional progression-free, laryngectomy-free, distant metastasis-free, and overall survival rate was 86%, 94%, 89%, 92%, and 63%, respectively. Grade 2 mucositis or higher occurred in 48% of patients, and all experienced Grade 2 or higher pharyngitis during treatment. Xerostomia continued to decrease over time from the end of RT, with none complaining of Grade 2 toxicity at this analysis. The 2-year post-treatment percutaneous endoscopic gastrostomy-dependency rate for those with hypopharyngeal and laryngeal tumors was 31% and 15%, respectively. The most severe late complications were laryngeal necrosis, necrotizing fascitis, and a carotid rupture resulting in death 3 weeks after salvage laryngectomy. CONCLUSION: These preliminary results have shown that IMRT achieved encouraging locoregional control of locoregionally advanced laryngeal and hypopharyngeal carcinomas. Xerostomia improved over time. Pharyngoesophageal stricture with percutaneous endoscopic gastrostomy dependency remains a problem, particularly for patients with hypopharyngeal carcinoma and, to a lesser extent, those with laryngeal cancer. Strategies using IMRT to limit the dose delivered to the esophagus/inferior constrictor musculature without compromising target coverage might be useful to further minimize this late complication.


Asunto(s)
Neoplasias Hipofaríngeas/tratamiento farmacológico , Neoplasias Hipofaríngeas/radioterapia , Neoplasias Laríngeas/tratamiento farmacológico , Neoplasias Laríngeas/radioterapia , Radioterapia de Intensidad Modulada , Adulto , Anciano , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Carboplatino/administración & dosificación , Terapia Combinada/métodos , Supervivencia sin Enfermedad , Femenino , Fluorouracilo/administración & dosificación , Estudios de Seguimiento , Humanos , Neoplasias Hipofaríngeas/mortalidad , Neoplasias Hipofaríngeas/patología , Neoplasias Laríngeas/mortalidad , Neoplasias Laríngeas/patología , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica , Estudios Retrospectivos , Tasa de Supervivencia