Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Am J Kidney Dis ; 81(2): 156-167.e1, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36029966

RESUMEN

RATIONALE & OBJECTIVE: Early mortality rates of female patients receiving dialysis have been, at times, observed to be higher than rates among male patients. The differences in cause-specific mortality between male and female incident dialysis patients with kidney failure are not well understood and were the focus of this study. STUDY DESIGN: Retrospective cohort study. SETTING & PARTICIPANTS: Incident patients who had initiated dialysis in Australia and New Zealand in 1998-2018. EXPOSURE: Sex. OUTCOMES: Cause-specific and all-cause mortality while receiving dialysis, censored for kidney transplant. ANALYTICAL APPROACH: Adjusted cause-specific proportional hazards models, focusing on the first 5 years following initiation of dialysis. RESULTS: Among 53,414 patients (20,876 [39%] female) followed for a median period of 2.8 (IQR, 1.3-5.2) years, 27,137 (51%) died, with the predominant cause of death attributed to cardiovascular disease (18%), followed by dialysis withdrawal (16%). Compared with male patients, female patients were more likely to die in the first 5 years after dialysis initiation (adjusted hazard ratio [AHR], 1.08 [95% CI, 1.05-1.11]). Even though female patients experienced a lower risk of cardiovascular disease-related mortality (AHR, 0.93 [95% CI, 0.89-0.98]) than male patients, they experienced a greater risk of infection-related (AHR, 1.20 [95% CI, 1.10-1.32]) and dialysis withdrawal-related (AHR, 1.19 [95% CI, 1.13-1.26]) mortality. LIMITATIONS: Possibility of residual and unmeasured confounders. CONCLUSIONS: Compared with male patients, female patients had a higher risk of all-cause mortality in the first 5 years after dialysis initiation, a difference driven by higher rates of mortality from infections and dialysis withdrawals. These findings may inform the study of sex differences in mortality in other geographic settings.


Asunto(s)
Enfermedades Cardiovasculares , Fallo Renal Crónico , Humanos , Masculino , Femenino , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Estudios de Cohortes , Análisis de Supervivencia
2.
Nephrology (Carlton) ; 28(9): 510-514, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37337328

RESUMEN

Flash glucose monitoring (FGM) is increasingly used for blood glucose assessment due to ease of use and is now subsidized in Australia for blood glucose measurement for patients with Type 1 Diabetes Mellitus. Dysglycaemia is common following kidney transplantation and is associated with worse outcomes and there are data to support the use of FGM post-transplant to better detect and manage changes in blood glucose levels. There is, however, no data on patient or staff perceptions of FGM, or resource implications in this setting. We prospectively evaluated patients and nursing staff experiences of FGM compared to traditional capillary glucose measurement in the immediate post-transplant setting, along with resource utilization, cost of testing, staff time taken to test and accuracy. Twenty-one kidney transplant recipients had a FGM sensor applied in the post-operative period and results compared to capillary blood glucose monitoring (CBGM) measured at least four times a day. Six-hundred-fifty-six glucose measurements were obtained, median per patient of 30 readings (IQR 10). Pearson's correlation between FGM and CBGM readings is 0.95 (p < .001). FGM readings were lower than CBGM by an average of 1.2 mmol/L (SD 0.7). Using a 5-point preference questionnaire (with ratings varying from strongly disagree-strongly agree), both patients and nurses were highly satisfied with the usability and convenience of FGM, with all preferring FGM over CBGM. Average time to perform FGM was 3.6 s versus 64 s for CBGM. In average, cost of FGM was $58 less than traditional testing per patient. FGM is an accurate, convenient and cost-effective tool that may support optimal management of glycaemic control in the post-transplant period.


Asunto(s)
Diabetes Mellitus Tipo 1 , Trasplante de Riñón , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Trasplante de Riñón/efectos adversos , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/cirugía , Monitoreo Fisiológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA